Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Foot Ankle Int ; 38(11): 1229-1235, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28758439

RESUMEN

BACKGROUND: We present a classification system that progresses in severity, indicates the pathomechanics that cause the fracture and therefore guides the surgeon to what fixation will be necessary by which approach. METHODS: The primary posterior malleolar fracture fragments were characterized into 3 groups. A type 1 fracture was described as a small extra-articular posterior malleolar primary fragment. Type 2 fractures consisted of a primary fragment of the posterolateral triangle of the tibia (Volkmann area). A type 3 primary fragment was characterized by a coronal plane fracture line involving the whole posterior plafond. RESULTS: In type 1 fractures, the syndesmosis was disrupted in 100% of cases, although a proportion only involved the posterior syndesmosis. In type 2 posterior malleolar fractures, there was a variable medial injury with mixed avulsion/impaction etiology. In type 3 posterior malleolar fractures, most fibular fractures were either a high fracture or a long oblique fracture in the same fracture alignment as the posterior shear tibia fragment. Most medial injuries were Y-type or posterior oblique fractures. This fracture pattern had a low incidence of syndesmotic injury. CONCLUSION: The value of this approach was that by following the pathomechanism through the ankle, it demonstrated which other structures were likely to be damaged by the path of the kinetic energy. With an understanding of the pattern of associated injuries for each category, a surgeon may be able to avoid some pitfalls in treatment of these injuries. LEVEL OF EVIDENCE: Level III, retrospective comparative series.


Asunto(s)
Fracturas de Tobillo/clasificación , Fracturas de Tobillo/patología , Fijación Interna de Fracturas/métodos , Imagenología Tridimensional , Adulto , Fracturas de Tobillo/cirugía , Traumatismos del Tobillo/clasificación , Traumatismos del Tobillo/patología , Traumatismos del Tobillo/cirugía , Fenómenos Biomecánicos , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Reino Unido
2.
J Orthop Surg (Hong Kong) ; 20(3): 365-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23255648

RESUMEN

PURPOSE: To report outcomes of 21 total wrist arthroplasties (TWA) using the Universal 2 prosthesis. METHODS: Five men and 14 women aged 44 to 82 (mean, 62) years underwent 21 total wrist arthroplasties for rheumatoid arthritis (n=19) and post-traumatic arthritis (n=2) by a single surgeon using the Universal 2 prosthesis. Pre- and post-operative pain and function were assessed by a single surgeon using the Disabilities of the Arm, Shoulder and Hand (DASH) score and the patient-rated wrist evaluation (PRWE) score. Range of motion, stability, dislocation rate, and neurovascular status were also assessed. Radiographs were evaluated for implant alignment and fit, screw positioning, and implant loosening. RESULTS: The mean time to assessment of the range of motion was 3.1 (range, 1.8-3.9) years, and the mean time to assessment of the PRWE score was 4.8 (range, 2.1-7.3) years. The range of motion in each direction and the mean DASH and PRWE scores improved significantly following TWA. Two patients had restricted range of motion, which was treated by manipulation under anaesthetic (after 6 months in one and 8 weeks in the other). One patient underwent excision of a palmar bony bridge. One patient endured extensor pollicis longus rupture and underwent tendon transfer after 5 months. Radiographs revealed no evidence of implant loosening, migration, or malalignment. There was no sign of osteonecrosis in the remaining carpals or metacarpals. CONCLUSION: The Universal 2 TWA achieved significant improvement in range of motion and functional outcome of the wrist, with reduced rates of early joint instability, dislocation, and implant loosening, compared to previous implants. The small implant size and cementless design reduce bone loss and osteonecrosis.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo , Prótesis Articulares , Articulación de la Muñeca , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Rango del Movimiento Articular
3.
Open Orthop J ; 6: 482-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23173024

RESUMEN

AIM: This study reports the safety, efficacy and functional and patient centred outcomes of the largest published series of patients treated with the Rockwood clavicle pin (intramedullary device) to date. PATIENTS AND METHODS: A retrospective review of case notes, radiographs and follow-up by questionnaire was conducted. 86 patients were operated upon, 70 for acute fractures (group A) and 16 for non-union (group B). RESULTS: Rate of non-union was 2 (2.9%) in group A and 0 in group B. Mean Disability of the Arm, Shoulder and Hand (DASH) scores were 5.9 for group A and 8.7 for group B. Satisfaction was rated as good or excellent in 61 (96.8%) of responders and all patients would have the procedure again. Pin prominence was the predominant complication in both groups and all patients underwent a second procedure for metalwork removal. DISCUSSION: Rockwood clavicle pins are as effective as plates in achieving union and maintaining length, however the advantages of this less invasive technique should be weighed against the common complication of pin prominence and the inconvenience of removal of metalwork in all cases.

4.
Acta Orthop Belg ; 78(3): 309-16, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22822569

RESUMEN

This retrospective study compared clinical, radiological and subjective outcomes between patients with a distal radius fracture fixed with a variable angle or fixed angle volar locking plate. Radiological parameters were assessed between initial and final post-operative films. Post-operative clinical range of motion as a proportion of that in the opposite wrist was assessed clinically, and satisfaction and subjective outcomes were assessed by questionnaire. One hundred and seven patients were included in the study; 65 underwent fixation with a variable angle and 42 with a fixed angle locking plate. There were five complications and secondary operations in each group. There was no significant difference between the groups in radiological parameters measured or the proportional range of motion. Visual analogue scale, Mayo Wrist and Quick DASH scores were not significantly different between the groups. Neither the subjective nor clinical outcomes of this study demonstrated clinical superiority of either plate system.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fijación Interna de Fracturas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Fracturas del Radio/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...