Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
J Am Acad Orthop Surg ; 32(3): e134-e145, 2024 Feb 01.
Article En | MEDLINE | ID: mdl-37824083

BACKGROUND: Intramedullary nail fixation is commonly used for prophylactic stabilization of impending and fixation of complete pathological fractures of the long bones. However, metallic artifacts complicate imaging evaluation for bone healing or tumor progression and postoperative radiation planning. Carbon-fiber implants have gained popularity as an alternative, given their radiolucency and superior axial bending. This study evaluates incidences of mechanical and nonmechanical complications. METHODS: Adult patients (age 18 years and older) treated with carbon-fiber nails for impending/complete pathological long bone fractures secondary to metastases from 2013 to 2020 were analyzed for incidences and risk factors of mechanical and nonmechanical complications. Mechanical complications included aseptic screw loosening and structural failures of host bone and carbon-fiber implants. Deep infection and tumor progression were considered nonmechanical. Other complications/adverse events were also reported. RESULTS: A total of 239 patients were included; 47% were male, and 53% were female, with a median age of 68 (IQR, 59 to 75) years. Most common secondary metastases were related to breast cancer (19%), lung cancer (19%), multiple myeloma (18%), and sarcoma (13%). In total, 17 of 30 patients with metastatic sarcoma received palliative intramedullary nail fixation for impending/complete pathological fractures, and 13 of 30 received prophylactic nail stabilization of bone radiated preoperatively to manage juxta-osseous soft-tissue sarcomas, where partial resection of the periosteum or bone was necessary for negative margin resection. 33 (14%) patients had complications. Mechanical failures included 4 (1.7%) structural host bone failures, 7 (2.9%) implant structural failures, and 1 (0.4%) aseptic loosening of distal locking screws. Nonmechanical failures included 8 (3.3%) peri-implant infections and 15 (6.3%) tumor progressions with implant contamination. The 90-day and 1-year mortalities were 28% (61/239) and 53% (53/102), respectively. The literature reported comparable failure and mortality rates with conventional titanium treatment. CONCLUSIONS: Carbon-fiber implants might be an alternative for treating impending and sustained pathological fractures secondary to metastatic bone disease. The seemingly comparable complication profile warrants further cohort studies comparing carbon-fiber and titanium nail complications.


Fracture Fixation, Intramedullary , Fractures, Spontaneous , Sarcoma , Aged , Female , Humans , Male , Middle Aged , Bone Nails , Carbon Fiber , Fracture Fixation, Intramedullary/methods , Fractures, Spontaneous/etiology , Titanium , Treatment Outcome
2.
Front Bioeng Biotechnol ; 11: 1114711, 2023.
Article En | MEDLINE | ID: mdl-36937770

Introduction: Spinal stability plays a crucial role in the success of the surgical treatment of lumbar vertebral metastasis and, in current practice, less invasive approaches such as short constructs have been considered. Concurrently, carbon fiber-reinforced (CFR) poly-ether-ether-ketone (PEEK) fixation devices are expanding in oncologic spinal surgery thanks to their radiotransparency and valid mechanical properties. This study attempts to provide an exhaustive biomechanical comparison of different CFR-PEEK surgical stabilizations through a highly reproducible experimental setup. Methods: A Sawbones biomimetic phantom (T12-S1) was tested in flexion, extension, lateral bending, and axial rotation. An hemisome lesion on L3 vertebral body was mimicked and different pedicle screw posterior fixations were realized with implants from CarboFix Orthopedics Ltd: a long construct involving two spinal levels above and below the lesion, and a short construct involving only the levels adjacent to L3, with and without the addition of a transverse rod-rod cross-link; to provide additional insights on its long-term applicability, the event of a pedicle screw loosening was also accounted. Results: Short construct reduced the overloading onset caused by long stabilization. Particularly, the segmental motion contribution less deviated from the physiologic pattern and also the long-chain stiffness was reduced with respect to the prevalent long construct. The use of the cross-link enhanced the short stabilization by making it significantly stiffer in lateral bending and axial rotation, and by limiting mobiliza-tion in case of pedicle screw loosening. Discussion: The present study proved in vitro the biomechanical benefits of cross-link augmentation in short CFR-PEEK fixation, demonstrating it to be a potential alternative to standard long fixation in the surgical management of lumbar metastasis.

...