RESUMEN
Dabigatran etexilate (direct thrombin inhibitor) is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc), correlate cc with classic coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT), and evaluate them according to the creatinine clearance (CLCr). Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation) receiving dabigatran at 150 (n = 19) or 110 (n = 21) mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL). PT and APTT (IL) were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL). DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients' cc: median 83 (4-945) ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min) showed significantly higher median cc: 308 (49-945), compared to the average 72 (12-190) and highest tertile, 60 (4-118) ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies.
Asunto(s)
Antitrombinas/sangre , Creatinina/sangre , Dabigatrán/sangre , Adulto , Anciano , Anciano de 80 o más Años , Monitoreo de Drogas , Femenino , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Tiempo de Tromboplastina Parcial , Insuficiencia Renal/sangre , Tiempo de Trombina , Adulto JovenRESUMEN
El dabigatrán etexilato (inhibidor directo de trombina) es eficaz en la prevención tromboembólica en pacientes con fibrilación auricular. No requiere control rutinario de laboratorio, pero dada su eliminación renal, sería importante medirlo ante el deterioro de la función renal. Los objetivos del trabajo fueron verificar la calidad analítica del ensayo tiempo de trombina diluido para medición de la concentración plasmática (cc) de dabigatrán, correlacionar las cc con las pruebas básicas de coagulación tiempo de protrombina (TP) y tiempo de tromboplastina parcial activada (APTT) y evaluarlas de acuerdo al clearance de creatinina (CLCr). Se utilizaron muestras de plasma de 40 pacientes que recibían dabigatrán 150 (n = 19) o 110 (n = 21) mg/12 horas, colectadas 10-14 horas después de la última toma. Los ensayos de trombina diluida HemosIL DTI para la medición de dabigatrán, TP y APTT (IL), fueron realizados en coagulómetros fotoópticos ACL TOP 300 y 500 (IL). El DTI presentó coeficiente de variación intraensayo < 5.4% e interensayo < 6.0%, rango de linealidad 0-493 ng/ml; cc medidas en pacientes: mediana 83 (4-945) ng/ml. Individuos con CLCr en tercil inferior (< 46.1 ml/min) presentaron cc significativamente más elevadas, 308 (49-945), que los de tercilos medio, 72 (12-190), y superior, 60 (4-118) ng/ml. Las correlaciones cc vs. APTT o TP fueron moderadas, r2 = 0.59, -0.66, p < 0.0001, respectivamente. La prueba ensayada permitió cuantificar el nivel de dabigatrán plasmático tanto en pacientes con función renal normal como deteriorada, representando una herramienta útil en situaciones clínicas como deterioro de la función renal, pre cirugía o emergencias.
Dabigatran etexilate (direct thrombin inhibitor) is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc), correlate cc with classic coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT), and evaluate them according to the creatinine clearance (CLCr). Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation) receiving dabigatran at 150 (n = 19) or 110 (n = 21) mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL). PT and APTT (IL) were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL). DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients´ cc: median 83 (4-945) ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min) showed significantly higher median cc: 308 (49-945), compared to the average 72 (12-190) and highest tertile, 60 (4-118) ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies.
Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Antitrombinas/sangre , Creatinina/sangre , Dabigatrán/sangre , Tiempo de Tromboplastina Parcial , Tiempo de Trombina , Monitoreo de Drogas , Insuficiencia Renal/sangre , Pruebas de Función RenalAsunto(s)
Humanos , Anticuerpos/aislamiento & purificación , Heparina/efectos adversos , /inmunología , Trombocitopenia/diagnóstico , Anticuerpos/efectos adversos , Ensayo de Inmunoadsorción Enzimática , Heparina/inmunología , Nefelometría y Turbidimetría/métodos , Trombocitopenia/sangre , Trombocitopenia/inducido químicamenteAsunto(s)
Anticuerpos/aislamiento & purificación , Heparina/efectos adversos , Factor Plaquetario 4/inmunología , Trombocitopenia/diagnóstico , Anticuerpos/efectos adversos , Ensayo de Inmunoadsorción Enzimática , Heparina/inmunología , Humanos , Nefelometría y Turbidimetría/métodos , Trombocitopenia/sangre , Trombocitopenia/inducido químicamenteRESUMEN
La trombocitopenia inducida por heparina (HIT) es un efecto adverso del tratamiento con heparina, mediada por anticuerpos anti complejo factor plaquetario 4 (PF4)-heparina (HPIA). La HIT es frecuentemente moderada pero pueden desarrollarse complicaciones trombóticas. El diagnóstico precoz es importante. La detección de HPIA por ELISA tiene alta sensibilidad pero baja especificidad (títulos bajos sin significación clínica). El índice de las 4T (índice 4T) puede detectar pacientes con alto riesgo de HIT. El propósito del estudio fue correlacionar los niveles de HPIA y el índice 4T de un grupo de pacientes derivados a nuestro centro. Evaluamos 84 pacientes, 34 de ellos desarrollaron trombosis. Cada médico completó un cuestionario clínico que fue remitido con la muestra a nuestro centro. Los cuestionarios fueron analizados por un investigador externo y el índice 4T se calculó previamente al ensayo. Los HPIA se determinaron por un ELISA (Asserachrom HPIA) que detecta los 3 isotipos, IgG, IgM e IgA, único reactivo disponible en Argentina. Los resultados se expresaron como porcentaje de absorbancia (%ABS). La correlación del índice 4T con los HPIA fue 0.472 (rho spearman, p < 0.001). Los pacientes con índice 4T ≥ 6 presentaban %ABS mayores que los ≤ 5 (67 vs. 39, p < 0.001). Aquéllos con trombosis presentaron títulos mayores que los que no la desarrollaron (%ABS 59 vs. 39, p = 0.017). En conclusión: Los títulos altos de HPIA medidos por ELISA, que detecta los 3 isotipos, correlacionaron claramente con el índice 4T ≥ 6 y fueron más frecuentes en los pacientes con trombosis, coincidiendo con lo ya descripto para ensayos de ELISA específicos para isotipo IgG.
Heparin induced thrombocytopenia (HIT) is an immune-mediated disorder due to antibodies anti platelet factor 4-heparin (HPIA). Thrombocytopenia is often moderate but certain patients can develop morbid thrombotic complications. HPIA detection by ELISA has high sensitivity but low specificity, and low titers (without clinical significance) are frequent. A pretest clinical score (4T´s) was developed in order to recognize patients that are at high risk of HIT. The aim of this study was to correlate HPIA levels and the 4T´s score of consecutive patients derived to our center. We evaluated 84 patients (35 of them developed thrombosis); the clinical questionnaire was sent along with the sample and was analyzed by an investigator who did not know the patients´ characteristics, and 4T´s scores were calculated before performing the laboratory tests. HPIA were measured by ELISA (Asserachrom HPIA) that detects IgG, IgM and IgA isotypes, (the only reagent available in our country). 4T´s score correlated with HPIA levels (rho spearman 0.472, p < 0.001). Patients with 4T´s ≥ 6 had higher absorbance percentages than those with ≤ 5 (67 vs. 39%, p < 0.001), and patients with thrombosis also presented higher titers (59 vs. 39%, p = 0.017) than those who did not develop this complication. In conclusion, high titers of HPIA measured by EIA which detects the 3 isotypes, clearly correlate with 4T´s score ≥ 6 and are more frequent in patients who develop thrombosis, just as reported when an IgG specific ELISA is used.
Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anticuerpos/análisis , Anticoagulantes/efectos adversos , Heparina/efectos adversos , /inmunología , Trombocitopenia/inducido químicamente , Anticoagulantes/inmunología , Ensayo de Inmunoadsorción Enzimática , Heparina/inmunología , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Inhibidores de Agregación Plaquetaria/química , Trombocitopenia/diagnóstico , Trombosis/etiologíaRESUMEN
La trombocitopenia inducida por heparina (HIT) es un efecto adverso del tratamiento con heparina, mediada por anticuerpos anti complejo factor plaquetario 4 (PF4)-heparina (HPIA). La HIT es frecuentemente moderada pero pueden desarrollarse complicaciones trombóticas. El diagnóstico precoz es importante. La detección de HPIA por ELISA tiene alta sensibilidad pero baja especificidad (títulos bajos sin significación clínica). El índice de las 4T (índice 4T) puede detectar pacientes con alto riesgo de HIT. El propósito del estudio fue correlacionar los niveles de HPIA y el índice 4T de un grupo de pacientes derivados a nuestro centro. Evaluamos 84 pacientes, 34 de ellos desarrollaron trombosis. Cada médico completó un cuestionario clínico que fue remitido con la muestra a nuestro centro. Los cuestionarios fueron analizados por un investigador externo y el índice 4T se calculó previamente al ensayo. Los HPIA se determinaron por un ELISA (Asserachrom HPIA) que detecta los 3 isotipos, IgG, IgM e IgA, único reactivo disponible en Argentina. Los resultados se expresaron como porcentaje de absorbancia (%ABS). La correlación del índice 4T con los HPIA fue 0.472 (rho spearman, p < 0.001). Los pacientes con índice 4T ≥ 6 presentaban %ABS mayores que los ≤ 5 (67 vs. 39, p < 0.001). Aquéllos con trombosis presentaron títulos mayores que los que no la desarrollaron (%ABS 59 vs. 39, p = 0.017). En conclusión: Los títulos altos de HPIA medidos por ELISA, que detecta los 3 isotipos, correlacionaron claramente con el índice 4T ≥ 6 y fueron más frecuentes en los pacientes con trombosis, coincidiendo con lo ya descripto para ensayos de ELISA específicos para isotipo IgG.(AU)
Heparin induced thrombocytopenia (HIT) is an immune-mediated disorder due to antibodies anti platelet factor 4-heparin (HPIA). Thrombocytopenia is often moderate but certain patients can develop morbid thrombotic complications. HPIA detection by ELISA has high sensitivity but low specificity, and low titers (without clinical significance) are frequent. A pretest clinical score (4T´s) was developed in order to recognize patients that are at high risk of HIT. The aim of this study was to correlate HPIA levels and the 4T´s score of consecutive patients derived to our center. We evaluated 84 patients (35 of them developed thrombosis); the clinical questionnaire was sent along with the sample and was analyzed by an investigator who did not know the patients´ characteristics, and 4T´s scores were calculated before performing the laboratory tests. HPIA were measured by ELISA (Asserachrom HPIA) that detects IgG, IgM and IgA isotypes, (the only reagent available in our country). 4T´s score correlated with HPIA levels (rho spearman 0.472, p < 0.001). Patients with 4T´s ≥ 6 had higher absorbance percentages than those with ≤ 5 (67 vs. 39%, p < 0.001), and patients with thrombosis also presented higher titers (59 vs. 39%, p = 0.017) than those who did not develop this complication. In conclusion, high titers of HPIA measured by EIA which detects the 3 isotypes, clearly correlate with 4T´s score ≥ 6 and are more frequent in patients who develop thrombosis, just as reported when an IgG specific ELISA is used.(AU)
Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anticuerpos/análisis , Anticoagulantes/efectos adversos , Heparina/efectos adversos , Factor Plaquetario 4/inmunología , Trombocitopenia/inducido químicamente , Anticoagulantes/inmunología , Ensayo de Inmunoadsorción Enzimática , Heparina/inmunología , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Inhibidores de Agregación Plaquetaria/química , Trombocitopenia/diagnóstico , Trombosis/etiologíaRESUMEN
La trombocitopenia inducida por heparina (HIT) es un efecto adverso del tratamiento con heparina, mediada por anticuerpos anti complejo factor plaquetario 4 (PF4)-heparina (HPIA). La HIT es frecuentemente moderada pero pueden desarrollarse complicaciones trombóticas. El diagnóstico precoz es importante. La detección de HPIA por ELISA tiene alta sensibilidad pero baja especificidad (títulos bajos sin significación clínica). El índice de las 4T (índice 4T) puede detectar pacientes con alto riesgo de HIT. El propósito del estudio fue correlacionar los niveles de HPIA y el índice 4T de un grupo de pacientes derivados a nuestro centro. Evaluamos 84 pacientes, 34 de ellos desarrollaron trombosis. Cada médico completó un cuestionario clínico que fue remitido con la muestra a nuestro centro. Los cuestionarios fueron analizados por un investigador externo y el índice 4T se calculó previamente al ensayo. Los HPIA se determinaron por un ELISA (Asserachrom HPIA) que detecta los 3 isotipos, IgG, IgM e IgA, único reactivo disponible en Argentina. Los resultados se expresaron como porcentaje de absorbancia (%ABS). La correlación del índice 4T con los HPIA fue 0.472 (rho spearman, p < 0.001). Los pacientes con índice 4T ≥ 6 presentaban %ABS mayores que los ≤ 5 (67 vs. 39, p < 0.001). Aquéllos con trombosis presentaron títulos mayores que los que no la desarrollaron (%ABS 59 vs. 39, p = 0.017). En conclusión: Los títulos altos de HPIA medidos por ELISA, que detecta los 3 isotipos, correlacionaron claramente con el índice 4T ≥ 6 y fueron más frecuentes en los pacientes con trombosis, coincidiendo con lo ya descripto para ensayos de ELISA específicos para isotipo IgG.(AU)
Heparin induced thrombocytopenia (HIT) is an immune-mediated disorder due to antibodies anti platelet factor 4-heparin (HPIA). Thrombocytopenia is often moderate but certain patients can develop morbid thrombotic complications. HPIA detection by ELISA has high sensitivity but low specificity, and low titers (without clinical significance) are frequent. A pretest clinical score (4T´s) was developed in order to recognize patients that are at high risk of HIT. The aim of this study was to correlate HPIA levels and the 4T´s score of consecutive patients derived to our center. We evaluated 84 patients (35 of them developed thrombosis); the clinical questionnaire was sent along with the sample and was analyzed by an investigator who did not know the patients´ characteristics, and 4T´s scores were calculated before performing the laboratory tests. HPIA were measured by ELISA (Asserachrom HPIA) that detects IgG, IgM and IgA isotypes, (the only reagent available in our country). 4T´s score correlated with HPIA levels (rho spearman 0.472, p < 0.001). Patients with 4T´s ≥ 6 had higher absorbance percentages than those with ≤ 5 (67 vs. 39%, p < 0.001), and patients with thrombosis also presented higher titers (59 vs. 39%, p = 0.017) than those who did not develop this complication. In conclusion, high titers of HPIA measured by EIA which detects the 3 isotypes, clearly correlate with 4T´s score ≥ 6 and are more frequent in patients who develop thrombosis, just as reported when an IgG specific ELISA is used.(AU)
Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anticuerpos/análisis , Anticoagulantes/efectos adversos , Heparina/efectos adversos , Factor Plaquetario 4/inmunología , Trombocitopenia/inducido químicamente , Anticoagulantes/inmunología , Ensayo de Inmunoadsorción Enzimática , Heparina/inmunología , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Inhibidores de Agregación Plaquetaria/química , Trombocitopenia/diagnóstico , Trombosis/etiologíaRESUMEN
Heparin induced thrombocytopenia (HIT) is an immune-mediated disorder due to antibodies anti platelet factor 4-heparin (HPIA). Thrombocytopenia is often moderate but certain patients can develop morbid thrombotic complications. HPIA detection by ELISA has high sensitivity but low specificity, and low titers (without clinical significance) are frequent. A pretest clinical score (4T's) was developed in order to recognize patients that are at high risk of HIT. The aim of this study was to correlate HPIA levels and the 4T's score of consecutive patients derived to our center. We evaluated 84 patients (35 of them developed thrombosis); the clinical questionnaire was sent along with the sample and was analyzed by an investigator who did not know the patients' characteristics, and 4T's scores were calculated before performing the laboratory tests. HPIA were measured by ELISA (Asserachrom HPIA) that detects IgG, IgM and IgA isotypes, (the only reagent available in our country). 4T's score correlated with HPIA levels (rho spearman 0.472, p < 0.001). Patients with 4T's = 6 had higher absorbance percentages than those with = 5 (67 vs. 39%, p < 0.001), and patients with thrombosis also presented higher titers (59 vs. 39%, p = 0.017) than those who did not develop this complication. In conclusion, high titers of HPIA measured by EIA which detects the 3 isotypes, clearly correlate with 4T's score = 6 and are more frequent in patients who develop thrombosis, just as reported when an IgG specific ELISA is used.
Asunto(s)
Anticuerpos/análisis , Anticoagulantes/efectos adversos , Heparina/efectos adversos , Factor Plaquetario 4/inmunología , Trombocitopenia/inducido químicamente , Adulto , Anciano , Anticoagulantes/inmunología , Ensayo de Inmunoadsorción Enzimática , Femenino , Heparina/inmunología , Humanos , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/química , Trombocitopenia/diagnóstico , Trombosis/etiologíaRESUMEN
La presencia de polimorfismos protrombóticos y algunas alteraciones fibrinolíticas han sido descriptas en las pacientes con pérdidas de embarazos (PE) recurrentes si bien no hay datos concluyentes al respecto y menos aún en pacientes con falla de implantación. El objetivo del trabajo fue en primer lugar analizar la prevalencia de 3 polimorfismos protrombóticos [Factor V Leiden, Polimorfismo del gen de la Protrombina 20210 (PT 20210) y polimorfismo del promotor del PAI 1 (4G5G)] en 147 pacientes con historia de PE comparados con un grupo control de mujeres sanas con historia de embarazos sin complicaciones. En segundo lugar, analizar la correlación entre 3 pruebas del sistema fibrínolítico: PAI 1 inmunológico, Lisis de euglobulinas (LE) pre y post isquemia y polimorfismo del PAI 1 4G5G en un grupo de 92 mujeres con historia de PE (n=49) o fallas de implantación (FI) post procedimientos de fertilización in vitro ( n=43). La prevalencia de los polimorfismos protrombóticos estudiados en las pacientes no fue significativamente diferente de la hallada en el grupo control normal, excepto para el Factor V Leiden en PE tardías (p=0.03) y sólo una tendencia para el PAI 4G4G en abortos tempranos recurrentes (p=0.08). La respuesta en la LE post isquemia fue mala en el 17.4% y ligeramente alterada en el 19.3%. Considerando a la población total de 92 mujeres con complicaciones obstétricas, no existió relación entre los niveles de PAlIo la respuesta fibrinolitica a la isquemia con el genotipo del promotor del PAI. Los niveles de PAI 1 estuvieron significativamente más elevados en las mujeres que presentaban factores de riesgo clásico de enfermedad cardiovascular (32.46 vs. 20.6 ng/rol, p=0.023), y esto fue especialmente debido al grupo de portadoras del genotipo homocigota 4G4G. Los niveles de PAI 1 y las LE pre y post isquemia presentaron correlación positiva con el índice de masa corporal...
Asunto(s)
Polimorfismo Genético , Complicaciones del EmbarazoRESUMEN
La presencia de polimorfismos protrombóticos y algunas alteraciones fibrinolíticas han sido descriptas en las pacientes con pérdidas de embarazos (PE) recurrentes si bien no hay datos concluyentes al respecto y menos aún en pacientes con falla de implantación. El objetivo del trabajo fue en primer lugar analizar la prevalencia de 3 polimorfismos protrombóticos [Factor V Leiden, Polimorfismo del gen de la Protrombina 20210 (PT 20210) y polimorfismo del promotor del PAI 1 (4G5G)] en 147 pacientes con historia de PE comparados con un grupo control de mujeres sanas con historia de embarazos sin complicaciones. En segundo lugar, analizar la correlación entre 3 pruebas del sistema fibrínolítico: PAI 1 inmunológico, Lisis de euglobulinas (LE) pre y post isquemia y polimorfismo del PAI 1 4G5G en un grupo de 92 mujeres con historia de PE (n=49) o fallas de implantación (FI) post procedimientos de fertilización in vitro ( n=43). La prevalencia de los polimorfismos protrombóticos estudiados en las pacientes no fue significativamente diferente de la hallada en el grupo control normal, excepto para el Factor V Leiden en PE tardías (p=0.03) y sólo una tendencia para el PAI 4G4G en abortos tempranos recurrentes (p=0.08). La respuesta en la LE post isquemia fue mala en el 17.4% y ligeramente alterada en el 19.3%. Considerando a la población total de 92 mujeres con complicaciones obstétricas, no existió relación entre los niveles de PAlIo la respuesta fibrinolitica a la isquemia con el genotipo del promotor del PAI. Los niveles de PAI 1 estuvieron significativamente más elevados en las mujeres que presentaban factores de riesgo clásico de enfermedad cardiovascular (32.46 vs. 20.6 ng/rol, p=0.023), y esto fue especialmente debido al grupo de portadoras del genotipo homocigota 4G4G. Los niveles de PAI 1 y las LE pre y post isquemia presentaron correlación positiva con el índice de masa corporal...(AU)
Asunto(s)
Polimorfismo Genético , Complicaciones del EmbarazoRESUMEN
En la literatura se describió que la prolongación de las pruebas de coagulación a baja concentración de ionescalcio se asociaba a la presencia de a132GPI en un pequeño grupo seleccionado de pacientes con anticoagulante lúpico (AL). Por ello se decidió evaluar la respuesta ala disminución en la concentración de calcio de los plasmas obtenidos de 318 pacientes consecutivos derivados a nuestro laboratorio para la investigación de AL. Se realizó el tiempo de protrombina diluido (dTP) utilizando una dilución 1:50 de tromboplastina recombinante a 2 concentraciones finales de calcio 15 y 5 mM. Se calculó el cociente P:N a ambas concentraciones y luego una relación de esos cocientes (razón 5:15). Setenta y cinco de 318 presentaron AL positivo. De los mismos, aquellos que presentaban a132GPI prolongaban significativamenteel dTP a bajas concentraciones de calcio: media de cocientes P:N 2.43 v s 2.96 a 15 y 5 m M respectivamente,p=0.05. Una prolongación mayor de120 porciento (razón 5:15 >1.2) se presentó en el 47.7 porciento de los pacientes con AL (+) y a132GPI (+) comparado con un 16.2 porciento de los pacientes AL (+) a132GPI (-), p=0.0014. Se observó que la presencia de a132GPI estaba asociada a la prolongación del dTP a bajas concentraciones de iones calcio, no obstante la sensibilidad de la prueba para identificar los AL asociados a a132GPI es baja.(AU)
Asunto(s)
Inhibidor de Coagulación del LupusRESUMEN
En la literatura se describió que la prolongación de las pruebas de coagulación a baja concentración de ionescalcio se asociaba a la presencia de a132GPI en un pequeño grupo seleccionado de pacientes con anticoagulante lúpico (AL). Por ello se decidió evaluar la respuesta ala disminución en la concentración de calcio de los plasmas obtenidos de 318 pacientes consecutivos derivados a nuestro laboratorio para la investigación de AL. Se realizó el tiempo de protrombina diluido (dTP) utilizando una dilución 1:50 de tromboplastina recombinante a 2 concentraciones finales de calcio 15 y 5 mM. Se calculó el cociente P:N a ambas concentraciones y luego una relación de esos cocientes (razón 5:15). Setenta y cinco de 318 presentaron AL positivo. De los mismos, aquellos que presentaban a132GPI prolongaban significativamenteel dTP a bajas concentraciones de calcio: media de cocientes P:N 2.43 v s 2.96 a 15 y 5 m M respectivamente,p=0.05. Una prolongación mayor de120 porciento (razón 5:15 >1.2) se presentó en el 47.7 porciento de los pacientes con AL (+) y a132GPI (+) comparado con un 16.2 porciento de los pacientes AL (+) a132GPI (-), p=0.0014. Se observó que la presencia de a132GPI estaba asociada a la prolongación del dTP a bajas concentraciones de iones calcio, no obstante la sensibilidad de la prueba para identificar los AL asociados a a132GPI es baja.