Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 140
1.
Article En | MEDLINE | ID: mdl-38833119

The MitraClip G4 device has controlled gripper actuation (CGA) system, which allows the anterior and posterior grippers operate separately in transcatheter edge-to-edge repair (TEER). We investigated the indications and outcomes of the use of CGA system during TEER for significant mitral regurgitation (MR). We reviewed 158 patients undergoing TEER with MitraClip G4 from September 2020 to July 2023. The CGA indications were: (1) for grasping and (2) for leaflet insertion confirmation. Leaflet grasping was completed with CGA in 18 patients (11 and 7 patients for grasping and leaflet insertion confirmation, respectively). Patients with flail leaflets or coaptation gap more frequently required CGA, indicating more complex mitral valve anatomy. The procedural success and adverse event rates (death, leaflet tear and single leaflet device attachment) were not different between the CGA and non-CGA groups. In patients requiring CGA, single leaflet device attachment was observed in 1 patient and leaflet tear in 1 patient during follow-up. In these two cases, CGA was required for grasping, and the clip was moved over a large distance (6.5 and 12.4 mm, respectively). In patients who had undergone CGA for confirmation, no device-related adverse event or MR recurrence was noted. In patients with complex mitral valve anatomy, CGA may be a safe and effective method for confirming leaflet insertion. It should be noted that when using CGA for leaflet grasping, especially when the clip is moved significantly, attention should be paid to leaflet adverse events.

2.
Heart Vessels ; 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38839649

Currently, no consensus has been established on the most effective antithrombotic therapy to prevent thromboembolic and bleeding events in patients undergoing percutaneous left atrial appendage closure (LAAC) with preprocedural thromboembolic or bleeding events under oral anticoagulation (OAC) therapy. We retrospectively investigated the incidence of device-related thrombosis (DRT), thromboembolic events, and bleeding events in patients who underwent LAAC from September 2019 to October 2022. After categorizing patients into three groups based on preprocedural thromboembolic or bleeding events under OAC therapy, we compared the incidence of DRT and prognosis according to the postprocedural antithrombotic therapy. In patients who received the conventional antithrombotic therapy (OAC with and without single antiplatelet therapy for 45 days after LAAC and dual-antiplatelet therapy from 45 days to 6 months followed by single antiplatelet therapy), preprocedural thromboembolic events despite OAC were independently associated with DRT or postprocedural thromboembolic events at the 3 year follow-up (hazard ratio [HR] 4.55; 95% confidence interval [CI] 1.32-15.6; P = 0.016), whereas preprocedural bleeding events were independently associated with postprocedural bleeding events (HR 8.01, 95% CI 1.45-58.3; P = 0.036). Continuation of OAC for 12 months among patients who developed preprocedural thromboembolic events during OAC significantly decreased the incidence of DRT or postoperative thromboembolic events (P = 0.002) with no increase in the bleeding events (P = 0.522). Preprocedural thromboembolic and bleeding events can predict adverse events after LAAC with the conventional antiplatelet-based antithrombotic therapy. Patients who develop thromboembolic events under continuous OAC may benefit from continuous OAC for 1 year after LAAC.

4.
Clin Case Rep ; 12(5): e8906, 2024 May.
Article En | MEDLINE | ID: mdl-38751959

Key Clinical Message: Atrial fibrillation ablation, including pulmonary vein isolation immediately after left atrial appendage closure (LAAC), is a rare and challenging issue. Intracardiac echocardiography guidance can help identify the LAAC device position for safe atrial fibrillation ablation without LAAC device-related adverse events even immediately after LAAC device implantation. Abstract: Early phase atrial fibrillation (AF) ablation after left atrial appendage closure (LAAC) is a rare and challenging issue. Here, we present a case illustrating the feasibility of AF ablation under intracardiac echocardiography guidance immediately after LAAC device implantation without LAAC device-related adverse events.

6.
JACC Case Rep ; 29(2): 102168, 2024 Jan 17.
Article En | MEDLINE | ID: mdl-38264305

An 81-year-old woman who had undergone transcatheter aortic valve implantation 3 months earlier underwent routine follow-up transthoracic echocardiography, which revealed a mobile thrombus adhering to the bioprosthetic valve. This thrombus differed in morphology from transcatheter aortic valve implantation valve thrombi commonly seen in daily practice.

7.
Cardiovasc Interv Ther ; 39(2): 191-199, 2024 Apr.
Article En | MEDLINE | ID: mdl-38064131

Contrast media are generally necessary for transcatheter left atrial appendage closure (LAAC), however, it should be avoided in patients with chronic kidney disease (CKD). The objective of this study was to evaluate the safety and feasibility of contrast-free LAAC with WATCHMAN FLX device for patients with CKD. Among 141 patients undergoing LAAC using the WATCHMAN FLX between May 2021 and March 2023, we performed LAAC without contrast media in 10 patients. Procedural and follow-up results were evaluated. The device size was selected based on the transesophageal echocardiographic (TEE) measurements. The device shape was assessed by fluoroscopy, and the device position was adjusted by TEE images. The mean age was 78 ± 4.9 years, CHADS2 score was 3.2 ± 1.1, and the estimated glomerular filtration rate (eGFR) was 28 ± 12 mL/min/1.73m2. The procedure was completed without contrast media in ten patients. Partial recapture of the device was required in four patients, but the initially selected device was finally implanted in all patients. Mean procedure time was significantly shorter in the contrast-free LAAC than in the contrast-use LAAC (41.6 ± 14.1 min vs 30.3 ± 7.6 min, p = 0.01). Postprocedural eGFR did not change from baseline, and there were no adverse events during the hospital stay. Follow-up TEE or cardiac computed tomography performed within 3 months after the procedure revealed no device-related thrombus or peri-device leak > 3 mm, and oral antithrombotic therapy was discontinued in all patients. Our experience shows that contrast-free LAAC using the WATCHMAN FLX device was safe and feasible. Non-contrast LAAC is one of the therapeutic options for patients with severe CKD.


Atrial Appendage , Atrial Fibrillation , Renal Insufficiency, Chronic , Stroke , Humans , Aged , Aged, 80 and over , Left Atrial Appendage Closure , Feasibility Studies , Contrast Media , Treatment Outcome , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Renal Insufficiency, Chronic/complications , Cardiac Catheterization , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Echocardiography, Transesophageal , Stroke/etiology
8.
J Echocardiogr ; 22(1): 16-24, 2024 Mar.
Article En | MEDLINE | ID: mdl-37644318

BACKGROUND: In left atrial appendage closure using WATCHMAN FLX, accurate device measurement by transesophageal echocardiography (TEE) is important. We aimed to experimentally validate appropriate methods of device measurement with two-dimensional (2D) and three-dimensional (3D) TEE compared with actual size. METHODS: We prepared a full range of device sizes (20, 24, 27, 31, 35 mm), each with five different compression rates. Each device was measured by 2D and 3D TEE at depths of 2, 4, and 6 cm in vitro using inner, outer, and middle line methods. We compared the difference between the actual size by caliper and measurements at each compression rate and depth by the three methods in 2D and 3D TEE. RESULTS: A total of 450 patterns of measurements were analyzed. The differences using the middle line method were much less than those using the inner and outer line methods in 2D and 3D TEE (2D TEE: 0.45 ± 0.36 vs. 2.55 ± 0.99 vs. 2.59 ± 0.72 mm, p < 0.01; 3D TEE: 0.34 ± 0.27 vs. 2.38 ± 0.69 vs. 1.86 ± 0.77 mm, p < 0.01). Moreover, the differences in measurements by 3D TEE were more accurate than those of 2D TEE in the inner (2.47 ± 1.86 vs. 1.86 ± 0.77 mm, p < 0.01) and middle (0.58 ± 0.37 vs. 0.34 ± 0.27 mm, p < 0.01) line methods. CONCLUSIONS: Middle line method by 3D TEE is the most reliable approach for device measurement at left atrial appendage closure using WATCHMAN FLX device.


Atrial Appendage , Atrial Fibrillation , Echocardiography, Three-Dimensional , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Left Atrial Appendage Closure , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Cardiac Catheterization/methods , Treatment Outcome , Echocardiography, Three-Dimensional/methods
10.
J Arrhythm ; 39(5): 816-818, 2023 Oct.
Article En | MEDLINE | ID: mdl-37799796

When we implant leadless pacemaker in patients with contrast agent allergy or poor renal function, the use of sufficient contrast agent is hesitant. Aided by imaging assessment (e.g., intracardiac echocardiography), the procedure may be feasible with a small amount of contrast medium or no contrast medium. In this case, leadless pacemaker implantation was performed at the same time as the transcatheter mitral valve repair, and leadless pacemaker implantation was successful with the use of a very small amount of contrast medium under transesophageal echocardiography guidance.

11.
Circ J ; 88(1): 127-132, 2023 Dec 25.
Article En | MEDLINE | ID: mdl-37899174

BACKGROUND: Evidence is limited regarding long-term clinical outcomes after alcohol septal ablation (ASA) for patients with hypertrophic obstructive cardiomyopathy and its periprocedural predictive factors in Japan.Methods and Results: This retrospective observational study included 44 patients who underwent ASA between 1998 and 2022 in a single center. We evaluated the periprocedural change in variables and long-term clinical outcomes after the procedure. The primary outcome was a composite of cardiovascular death or hospitalization for heart failure. The secondary outcome was all-cause death. Using multivariable Poisson regression with robust error variance, we predicted underlying periprocedural factors related to primary outcome development. ASA decreased the median pressure gradient at the left ventricular outflow tract from 88 to 33 mmHg and reduced moderate or severe mitral regurgitation (MR), present in 53% of patients before ASA, to 16%. Over a median 6-year follow-up, the cumulative incidence of the primary outcome at 5 and 10 years was 16.5% and 25.6%, respectively. After multivariable analysis, moderate or severe MR after ASA was significantly associated with the primary outcome (relative risk 8.78; 95% confidence interval 1.34-57.3; P=0.024). All-cause mortality after ASA was 15.1% and 28.9% at 5 and 10 years, respectively. CONCLUSIONS: This study presents long-term clinical outcomes after ASA in Japan. Moderate or severe MR after ASA was significantly associated with the composite of cardiovascular death or hospitalization for heart failure.


Ablation Techniques , Cardiomyopathy, Hypertrophic , Heart Failure , Humans , Ablation Techniques/adverse effects , Ablation Techniques/methods , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/complications , Ethanol , Heart Failure/surgery , Heart Failure/complications , Japan , Retrospective Studies , Treatment Outcome , Heart Septum
12.
Eur Heart J Case Rep ; 7(9): ytad438, 2023 Sep.
Article En | MEDLINE | ID: mdl-37719004

Background: Leaflet tear and perforation are serious complications of transcatheter edge-to-edge repair (TEER) using the MitraClip system for severe mitral regurgitation (MR). However, no optimal bailout strategy has been established. Case summary: An 80-year-old woman developed heart failure due to acute ischaemic severe MR after primary percutaneous coronary intervention. Given the requirement for inotropic drugs and an intra-aortic balloon pump to stabilize her heart failure, we decided to perform TEER using the MitraClip G4 system. The NTW clip was selected considering the limited posterior leaflet, wide central MR, and delivery to the central A2/P2. The leaflet was successfully grasped, and the MR jet dramatically decreased while the clip was closed. However, the MR jet suddenly appeared after completely closing the clip arm. A new eccentric jet was detected coming from the mid-portion of the posterior leaflet, indicating leaflet perforation. We decided to manage the leaflet perforation by covering the perforated portion with a longer type of clip. An XTW clip was then carefully delivered to the previously grasped portion, after which we confirmed that the tip of the clip arm was positioned more posteriorly to the leaflet perforation. After slowly closing the clip, MR decreased to mild, with transoesophageal echocardiography showing no eccentric MR. After her haemodynamics stabilized, she was discharged 28 days after the procedure. Discussion: This case details a successful bailout clipping of a leaflet perforation using an XTW clip. Leaflet anatomy evaluation is important to ensure that the injured portion is covered by the longer clip arm.

14.
J Cardiol ; 81(2): 154-160, 2023 02.
Article En | MEDLINE | ID: mdl-36195251

BACKGROUND: Data on long-term outcomes of transcatheter aortic valve replacement (TAVR) in Japanese patients beyond 5 years are limited. METHODS: Between June 2010 and December 2014, 55 consecutive inoperable or high surgical risk patients underwent TAVR with SAPIEN XT valves (Edwards Lifesciences, Irvine, CA, USA) for severe aortic stenosis at our institution. Among them, 2 patients were excluded from the analysis because one was converted to open surgery during the TAVR procedure and the other could not undergo TAVR due to device delivery failure. We retrospectively analyzed long-term clinical outcomes of these 53 patients (mean age: 84.1 years; mean STS score: 8.4) who had at least a 7-year follow-up after TAVR. RESULTS: The rates of freedom from all-cause and cardiovascular deaths at 7 years were 35.8 % and 79.3 %, respectively. The moderate or severe structural valve deterioration (SVD) rate at 5 and 7 years was 7.2 % and 11.4 %, respectively. The rate of bioprosthetic valve failure (BVF) at 7 years was 6.2 %. CONCLUSIONS: The 7-year mortality rate of inoperable or high surgical risk patients treated with SAPIEN XT was high, while the cardiovascular mortality rate was acceptable. Although the poor survival rate limited the long-term assessment of SAPIEN XT valve durability, the incidence of SVD and BVF was not rare.


Aortic Valve Stenosis , East Asian People , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Humans , Aortic Valve Stenosis/ethnology , Aortic Valve Stenosis/surgery , Retrospective Studies , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Time Factors
16.
Circ J ; 86(3): 427-437, 2022 02 25.
Article En | MEDLINE | ID: mdl-34275976

BACKGROUND: The clinical significance of concomitant mitral regurgitation (MR) has not been well addressed in patients with severe aortic stenosis (AS).Methods and Results:We analyzed 3,815 patients from a retrospective multicenter registry of severe AS in Japan (CURRENT AS registry). We compared the clinical outcomes between patients with moderate/severe MR and with none/mild MR according to the initial treatment strategy (initial aortic valve replacement [AVR] or conservative strategy). The primary outcome measure was a composite of aortic valve-related death or heart failure hospitalization. At baseline, moderate/severe MR was present in 227/1,197 (19%) patients with initial AVR strategy and in 536/2,618 (20%) patients with a conservative strategy. The crude cumulative 5-year incidence of the primary outcome measure was significantly higher in patients with moderate/severe MR than in those with none/mild MR, regardless of the initial treatment strategy (25.2% vs. 14.4%, P<0.001 in the initial AVR strategy, and 63.3% vs. 40.7%, P<0.001 in the conservative strategy). After adjusting confounders, moderate/severe MR was not independently associated with higher risk for the primary outcome measure in the initial AVR strategy (hazard ratio [HR] 1.11, 95% confidence interval [CI] 0.67-1.83, P=0.69), and in the conservative strategy (HR 1.13, 95% CI 0.93-1.37, P=0.22). CONCLUSIONS: Concomitant moderate/severe MR was not independently associated with higher risk for the primary outcome measure regardless of the initial treatment strategy.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Registries , Retrospective Studies , Severity of Illness Index , Treatment Outcome
17.
EuroIntervention ; 17(17): e1407-e1416, 2022 Apr 01.
Article En | MEDLINE | ID: mdl-34726600

BACKGROUND: The association between renal morphological findings and changes in renal function in patients undergoing transcatheter aortic valve implantation (TAVI) is unexplored. AIMS: We aimed to investigate the association between renal morphological findings and changes in renal function in patients undergoing TAVI. METHODS: Among 283 consecutive patients undergoing TAVI between 2018 and 2021, the study sample included 224 patients. Renal morphological measurements were performed by preoperative multidetector computed tomography. Estimated glomerular filtration rate (eGFR) improvement and deterioration were defined as positive or negative changes in an eGFR of ≥10% one month after TAVI. The renal cortex thickness index was defined as the ratio of total renal cortex thickness to body surface area. RESULTS: The incidences of eGFR improvement and deterioration were 33.9% and 24.1%, respectively. The renal cortex thickness index had a significant correlation with changes in eGFR (r=0.34, p<0.01). The index of the area under the curve of renal cortex thickness for eGFR improvement and deterioration were 0.73 and 0.68, respectively. The cut-off values were 5.82 mm/m2 for eGFR improvement (odds ratio [OR]: 0.10; 95% confidence interval: 0.05-0.20; p<0.01) and 4.89 mm/m2 for eGFR deterioration (OR: 9.07; 95% confidence interval: 4.55-18.6; p<0.01). CONCLUSIONS: The renal cortex thickness index was associated with changes in renal function in patients who underwent TAVI. Its measurements might be useful for predicting the renal function change in patients undergoing TAVI.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Glomerular Filtration Rate , Humans , Kidney/diagnostic imaging , Kidney/physiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
18.
Heart Vessels ; 36(2): 277-284, 2021 Feb.
Article En | MEDLINE | ID: mdl-32902702

Left atrial appendage (LAA) evaluation is important to select the optimal LAA closure device for patients with atrial fibrillation (AF). The LAA characteristics of Japanese patients remain uninvestigated. We compared the LAA size and morphology between 212 Japanese AF patients before catheter ablation and 119 AF patients undergoing LAA closure in the United States (US). We measured the LAA ostial dimension and depth by transesophageal echocardiography in all patients and determined the LAA morphology types of Japanese patients by multidetector cardiac computed tomography and those of US patients by LAA angiography. The maximum LAA ostial dimension was significantly larger in Japanese patients than in US patients (22.6 ± 4.1 mm vs. 21.5 ± 3.5 mm, P = 0.02). Also, Japanese patients had larger maximum dimension and depth corrected by body surface area than US patients in both paroxysmal and nonparoxysmal AF groups. The angle showing the maximum dimension was 0° or 135° in approximately 75% of patients in both groups. The common LAA morphology types were "cauliflower" and "chicken wing" in Japanese patients and "cactus" and "windsock" in US patients. In this study, Japanese patients had a larger LAA size than US patients. Because the maximum LAA dimension was obtained at the same angles, the LAA measurement method for US patients can be applicable to Japanese patients.


Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Echocardiography, Transesophageal/methods , Multidetector Computed Tomography/methods , Risk Assessment , Aged , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Female , Follow-Up Studies , Humans , Incidence , Japan/epidemiology , Male , Retrospective Studies , Risk Factors , United States/epidemiology
19.
Heart Vessels ; 36(3): 297-307, 2021 Mar.
Article En | MEDLINE | ID: mdl-32880682

Little is known about the impact of a high-dose statin on cardiovascular outcomes after ST-elevation acute myocardial infarction (STEMI) in real-world Japanese patients. Between July 2011 and June 2017, 1110 consecutive STEMI patients underwent primary percutaneous coronary intervention at our hospital and were discharged. A high-dose statin was administered in 117 patients (10.5%) and non-high-dose statin was administered in 947 patients (85.3%). The low-density lipoprotein cholesterol level was significantly higher in the high-dose statin group at admission (129.8 ± 44.9 vs. 110.4 ± 32.7, p < 0.0001), but the levels were not significantly different at follow-up (86.7 ± 25.7 vs. 85.0 ± 25.0, p = 0.52). The cumulative 2-year incidence of a composite of cardiac death, myocardial infarction, ischemic stroke, and any unplanned coronary revascularization was significantly lower in the high-dose statin group (6.2% vs. 16.9%, log-rank p = 0.004). Propensity score matched analysis indicated similar results. Among the types of coronary revascularization, a high-dose statin was significantly correlated with a lower rate of de novo lesion revascularization (hazard ratio 0.31; 95% confidence interval 0.08-0.83; p = 0.02). The results of our analyses indicate that administration of a high-dose statin may result in better cardiovascular outcomes after STEMI mainly by reducing the rate of revascularization for de novo lesions regardless of the achieved low-density lipoprotein cholesterol level in real-world patients.


Hydroxymethylglutaryl-CoA Reductase Inhibitors/administration & dosage , Propensity Score , ST Elevation Myocardial Infarction/therapy , Aged , Coronary Angiography , Dose-Response Relationship, Drug , Electrocardiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/methods , Prospective Studies , ST Elevation Myocardial Infarction/diagnosis , Treatment Outcome
...