Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 18(4): e0284699, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37099567

RESUMEN

INTRODUCTION: Coronavirus disease 2019 (COVID-19) pandemic has influenced health-care organization worldwide, including management of non-communicable diseases. The aim of this study was to determine the impact of COVID-19 pandemic on cardiac implantable electronic devices' (CIEDs) implantation rates in Croatia. METHODS: A retrospective, observational, national study was conducted. The data on CIEDs' implantation rates from 20 Croatian implantation centres, between January 2018 and June 2021, were extracted from the national Health Insurance Fund registry. Implantation rates before and after COVID-19 pandemic started, were compared. RESULTS: The overall numbers of CIED implantations in Croatia during COVID-19 pandemic were not different in comparison to 2 years pre-COVID-19 time (2618 vs. 2807, p = .081). The pacemaker implantation rates decreased significantly (by 45%) during April (122 vs. 223, p < .001) and May 2020 (135 vs. 244, p = .001), as well as during November 2020 (177 vs. 264, p = .003), but significantly increased during summer months 2020 comparing to 2018 and 2019 (737 vs. 497, p<0.001). The ICD implantation rates decreased significantly by 59% in April 2020 (26 vs. 64, p = .048). CONCLUSION: To the authors best knowledge this is a first study including complete national data on CIED implantation rates and COVID-19 pandemic impact. A significant reduction in number of both pacemaker and ICD implants during specific months of the COVID-19 pandemic was determined. However, afterwards compensation in implants resulted in similar total number when the complete year was evaluated.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Croacia/epidemiología , Pandemias , Estudios Retrospectivos , COVID-19/epidemiología
2.
Acta Clin Croat ; 57(2): 383-390, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30431735

RESUMEN

Four thousand cardiac implantable electronic devices (CIED) are implanted yearly in Croatia with constant increase. General anesthesia and surgery carry some specific risk for the patients with implanted CIEDs. Since most of the surgical procedures are performed in institutions without reprogramming devices available, or in the periods when they are unavailable, these guidelines aim to standardize the protocol for perioperative management of these patients. With this protocol, most of the procedures can be performed easily and, more importantly, safely in the majority of surgical patients.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Atención Perioperativa , Croacia , Humanos
3.
Acta Clin Croat ; 56(4): 618-624, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29590714

RESUMEN

Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.


Asunto(s)
Terapia de Resincronización Cardíaca , Técnicas Electrofisiológicas Cardíacas , Insuficiencia Cardíaca , Anciano , Ecocardiografía , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...