Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Orthop Traumatol Surg Res ; 109(3): 103546, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36627050

RESUMEN

INTRODUCTION: Total wrist arthrodesis is effective in reducing pain in osteoarthritic wrist, but at the cost of range of motion. The aim of the present study was to assess patient satisfaction after post-traumatic total wrist arthrodesis, complications and risk factors. HYPOTHESIS: Post-traumatic total wrist arthrodesis provides a high rate of satisfaction. PATIENTS AND METHODS: A single-center retrospective observational satisfaction survey was carried out for the period 2005-2020 by telephone interview. RESULTS: Forty-two post-traumatic dorsal plate total wrist arthrodeses were included. Mean follow-up was 97 months. Total arthrodesis achieved a mean 75% reduction in pain, with good functional results (QuickDASH: 23±9.1 [11-42]) and satisfaction (83% of patients very satisfied or satisfied). Seventy-two percent of patients continued in their previous work. The complications rate was 48%. Twenty patients had complications, including 14 (33%) requiring surgical revision. Thirteen patients (31%) had hardware removed due to plaque discomfort and 1 due to bone and joint infection. Seven patients showed CRPS. CONCLUSION: Total wrist arthrodesis provided good results in terms of pain relief and satisfaction, at the cost of loss of motion. It is a reliable surgical technique, with an essential place in the therapeutic algorithm for post-traumatic osteoarthritic wrist, particularly in manual workers. LEVEL OF EVIDENCE: IV, single-center retrospective observational study.


Asunto(s)
Artrodesis , Articulación de la Muñeca , Muñeca , Humanos , Artrodesis/métodos , Estudios de Seguimiento , Dolor , Satisfacción del Paciente , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación de la Muñeca/cirugía
2.
Arthrosc Sports Med Rehabil ; 2(5): e615-e622, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33135002

RESUMEN

PURPOSE: To assess intra-articular tunnel aperture positioning after primary anterior cruciate ligament (ACL) reconstruction with either the reference standard method or the intercondylar area method in a single center using 3-dimensional (3D) computed tomography (CT) scans and to evaluate the intra-articular position of the tibial tunnel relative to the ACL footprint. METHODS: 3D CT scans were performed after 120 single-bundle primary ACL reconstruction cases. The center of the tibial tunnel aperture and the center of the ACL footprint were referenced on axial views of the tibial plateau in the anteroposterior (AP) and mediolateral (ML) planes according to a centimetric grid system including the whole plateau (reference standard). This was compared with a grid system based on intercondylar area bony anatomy. The posterior aspect of intertubercular fossa, anterior aspect of the tibial plateau, medial intercondylar ridge, and crossing point between lateral intercondylar ridge and posterior margin were used as landmarks to define the grid. RESULTS: According to the reference standard method, the center of the tibial tunnel aperture was positioned 0.57 ± 2.62 mm more posterior and 0.67 ± 1.55 mm more medial than the center of the footprint. According to the intercondylar area method, the center of the tibial tunnel aperture was positioned 1.32 ± 2.74 mm more posterior and 0.66 ± 1.56 mm more medial than the center of the footprint. The position difference between the center of the tunnel aperture and the center of the footprint were statistically correlated for both grids, with r = -0.887, P < .001 for AP positioning and r = 0.615, P < .001 for ML positioning. CONCLUSION: This intercondylar area method using arthroscopic landmarks can be used to assess tunnel placement on 3D CT scans after ACL reconstruction. LEVEL OF EVIDENCE: III, retrospective comparative study.

3.
Arthroscopy ; 31(4): 691-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25660007

RESUMEN

PURPOSE: This study aimed to assess the benefit of using an arthroscopic intercondylar view and a posterior medial viewing portal during anterior cruciate ligament (ACL) reconstruction in the diagnosis of posterior horn of the medial meniscus (PHMM) tears. A secondary objective was to determine clinical and radiological risk factors for the PHMM. METHODS: Forty-one patients undergoing isolated ACL reconstruction were prospectively evaluated. At ACL reconstruction, the PHMM was assessed using a standard 30° arthroscope in 3 sequential stages: a "classic" anterolateral portal view, an intercondylar view, and a view through a posteromedial portal. RESULTS: Thirty-nine patients were included (12 female patients and 27 male patients). A posteromedial tear of the medial meniscus was found in 17 patients using the anterolateral portal view. The intercondylar view identified 4 new additional lesions and extensions of 3 previously identified lesions. The posteromedial portal view identified 6 new lesions and 5 extensions of known lesions compared with the anterolateral portal view. Two lesions seen through the posteromedial portal were not identified by either the anterolateral portal view or the intercondylar view. CONCLUSIONS: Tears of the PHMM may be underdiagnosed by intraoperative assessment using only an anterolateral portal view during ACL reconstruction. The intercondylar view combined with a posteromedial portal aids in the diagnosis of PHMM tears and should be considered in routine ACL reconstruction to assess meniscal status, particularly when the interval from injury to surgery is prolonged. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Errores Diagnósticos/prevención & control , Traumatismos de la Rodilla/diagnóstico , Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Adolescente , Adulto , Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Artroscopios , Artroscopía , Femenino , Humanos , Laceraciones , Masculino , Persona de Mediana Edad , Rotura , Lesiones de Menisco Tibial , Adulto Joven
4.
Hip Int ; 24(2): 200-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24619872

RESUMEN

PURPOSE: This study is aimed to determine whether the Traumax dynamic hip screw reduces perioperative blood loss and transfusion rate compared to the Gamma nail in the treatment of pertrochanteric fractures. MATERIALS AND METHODS: A series of 331 patients were followed prospectively in a cohort study between February 2008 and October 2011 after a pertrochanteric fracture. Two types of fixation were used, 163 patients were treated with a Gamma nail and 168 patients with a minimally invasive screw plate Traumax. Perioperative blood loss, evaluated by the Mercuriali formula based on pre- and postoperative haemoglobin and transfusion rates were compared in order to assess risk factors. RESULTS: Increased perioperative blood loss was significantly linked with patient-related parameters (age, anticoagulant and platelet aggregation inhibitor treatment). Type of osteosynthesis and type of fracture were also risk factors for blood loss and transfusion. The Traumax group had significantly lower blood loss (347 ml vs. 577 ml) and transfusion rate (33.9% vs. 63.8%) than the Gamma group. Involvement of the greater trochanter increased the risk of blood loss only in the Gamma group. Functional results and bone healing were comparable at six months follow-up. CONCLUSION: Screw plate Traumax significantly reduces perioperative bleeding after pertrochanteric fractures. It avoids fracture gaps that tend to maintain bleeding. Given the morbidity and complications related to acute anaemia and blood transfusion, the surgical management of these elderly patients is aided by this choice of fixation.


Asunto(s)
Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Clavos Ortopédicos , Tornillos Óseos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Anciano , Anciano de 80 o más Años , Pérdida de Sangre Quirúrgica/prevención & control , Femenino , Fijación Interna de Fracturas/instrumentación , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento
5.
Eur J Orthop Surg Traumatol ; 24(4): 519-23, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23558663

RESUMEN

To determine whether femoral implant position can be reproducibly measured on plain digital radiographs, we prospectively studied 40 patients after hip resurfacing arthroplasty. Three observers performed double blinded randomized analysis of calibrated digital radiographs meeting strict quality criteria. The implant stem-shaft angle and femoral anteversion angle were measured by the trapezoid method of axis determination using OsiriX software. The upper and lower offset and the anterior and posterior offset were measured. The statistical analysis was performed using Pearson correlation tests (intra-observer reproducibility) and Fisher F tests (inter-observer reproducibility). Intra-observer reproducibility was very good for all parameters and all observers. Inter-observer reproducibility was excellent except for superior offset measurement. Thus, this study validates a radiographic method for assessing the femoral implant position in hip resurfacing. We believe this could be useful for future studies on hip resurfacing devices.


Asunto(s)
Artrografía/estadística & datos numéricos , Artrografía/normas , Artroplastia de Reemplazo de Cadera/métodos , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/cirugía , Artrografía/métodos , Método Doble Ciego , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Imagen Asistido por Computador/normas , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados
6.
J Pediatr Orthop ; 34(1): 70-7, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23872797

RESUMEN

BACKGROUND: The management of anterior cruciate ligament (ACL) tears in growing patients must balance activity modification with the risk of secondary (meniscal and cartilaginous) lesions, and surgical intervention, which could adversely affect skeletal growth. Many ACL reconstruction techniques have been developed or modified to decrease the risk of growth disturbance. We have not found any description of ACL reconstruction using a single hamstring, short graft implanted into intraepiphyseal, retroreamed sockets. Our hypothesis was that the technique that we used restored the knee stability and did not cause any growth disturbances. METHODS: We retrospectively studied 28 patients (20 boys, 8 girls) who presented with a unilateral ACL tear and open growth plates. We performed short graft ligament reconstruction with the semitendinosus folded into 4 strands around 2 polyethylene terephthalate tapes. The graft was implanted into sockets that were retroreamed in the femoral and tibial epiphysis and the tapes were fixed remotely by interference screws. After a minimum period of 2 years, we evaluated the comparative knee laxity, the radiographic limb morphology, the appearance of secondary lesions, and the functional outcomes using the Lysholm and Tegner scores. Comparative analyses were performed using the Student t test with subgroups depending on the type of fixation used. RESULTS: The mean age of the patients was 13 years (range, 9 to 15 y). The mean follow-up was 2.8 years (range, 2 to 5 y). The mean difference in laxity at 134 N was 0.3 mm, as determined using a GNRB arthrometer. No patients reported meniscal symptoms or degenerative changes. We found no angular deformity or leg length inequality. Two patients suffered a recurrent ACL tear. CONCLUSIONS: The preliminary results from this series are consistent with prior studies demonstrating that intraepiphyseal ACL reconstruction is a safe reliable alternative for the pediatric population. STUDY DESIGN: Case series; level of evidence 4.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Traumatismos de la Rodilla/cirugía , Rango del Movimiento Articular/fisiología , Tendones/trasplante , Adolescente , Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Niño , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Supervivencia de Injerto , Humanos , Inestabilidad de la Articulación/prevención & control , Traumatismos de la Rodilla/diagnóstico por imagen , Masculino , Dolor Postoperatorio/fisiopatología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Radiografía , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Int Orthop ; 37(3): 361-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23359098

RESUMEN

PURPOSE: The positioning of the femoral cup in hip resurfacing is essential for the survival of the implant. We described a technique in 2005 to position the femoral cup guided by fluoroscopy independent of the approach performed. The main objectives were to study the positioning of the femoral components of the implant and the accuracy of the technique. METHODS: Between 2003 and 2011 we conducted a prospective study of 160 consecutive hip resurfacings all operated with this fluoroscopic-guided technique. Three independent observers performed a radiographic analysis at the pre-operative planning stage and on postoperative radiographs using OsiriX software. The statistical analysis was based on comparison of two groups by Student's t test. RESULTS: The entire implant was positioned in valgus, with an average of 7.816° valgus (p <0.001). All implants were positioned in neutral or anteverted with a mean of 1.98° (p <0.001). The risk of malpositioning on the antero-posterior plane was less than 1.41° with p <0.019. The risk of profile positioning error was lower than 0.80° with p <0.047. CONCLUSION: This study validates a technique of femoral implant positioning for resurfacing. It is simple, precise and independent of the approach performed.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Adulto , Femenino , Fluoroscopía , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS