Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 334
Filtrar
1.
World J Pediatr Congenit Heart Surg ; : 21501351241263752, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39166263

RESUMEN

Objectives: It is well-known that right ventricle-to-pulmonary artery homograft conduit durability is worse for smaller conduits and smaller/younger patients. However, there is limited literature on age and conduit-size specific outcomes, or on the role of conduit oversizing. Methods: Patients diagnosed with tetralogy of Fallot and major aortopulmonary collateral arteries undergoing right ventricular outflow tract (RVOT) reconstruction with a valved aortic homograft conduit from November 2001 through March 2023, at our institution were included. Conduits were grouped and evaluated by diameter, diameter Z-score, and patient age at implant. The primary time-related outcome was freedom from RVOT reintervention. Factors associated with freedom from time-related outcomes were assessed with univariable Cox regression analysis. Results: A total of 863 RVOT conduits were implanted in 722 patients. On multivariable analysis, younger age, male sex, Alagille syndrome, smaller diameter of the conduit, and smaller Z-score were associated with shorter freedom from reintervention. Among patients with smaller diameter conduits, larger Z-scores were associated with longer freedom from conduit reintervention (P < .001). Transcatheter interventions were commonly used to extend conduit lifespan across ages and conduit sizes. Conclusions: Larger conduit diameter, older age, and higher conduit Z-score were associated with longer freedom from reintervention in patients undergoing RVOT reconstruction in this cohort. Oversizing of conduits, even beyond a Z-score of 4, is generally appropriate.

2.
Front Immunol ; 15: 1343109, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39144147

RESUMEN

Introduction: Primary central nervous system lymphoma (PCNSL) is a rare type of non-Hodgkin's lymphoma that affects brain parenchyma, eyes, cerebrospinal fluid, and spinal cord. Diagnosing PCNSL can be challenging because imaging studies often show similar patterns as other brain tumors, and stereotactic brain lesion biopsy conformation is invasive and not always possible. This study aimed to validate a previous proteomic profiling (PMID: 32610669) of cerebrospinal fluid (CSF) and develop a CSF-based proteomic panel for accurate PCNSL diagnosis and differentiation. Methods: CSF samples were collected from patients of 30 PCNSL, 30 other brain tumors, and 31 tumor-free/benign controls. Liquid chromatography tandem-mass spectrometry targeted proteomics analysis was used to establish CSF-based proteomic panels. Results: Final proteomic panels were selected and optimized to diagnose PCNSL from tumor-free controls or other brain tumor lesions with an area under the curve (AUC) of 0.873 (95%CI: 0.723-0.948) and 0.937 (95%CI: 0.807- 0.985), respectively. Pathways analysis showed diagnosis panel features were significantly enriched in pathways related to extracellular matrices-receptor interaction, focal adhesion, and PI3K-Akt signaling, while prion disease, mineral absorption and HIF-1 signaling were significantly enriched with differentiation panel features. Discussion: This study suggests an accurate clinical test panel for PCNSL diagnosis and differentiation with CSF-based proteomic signatures, which may help overcome the challenges of current diagnostic methods and improve patient outcomes.


Asunto(s)
Biomarcadores de Tumor , Neoplasias Encefálicas , Proteómica , Humanos , Proteómica/métodos , Biomarcadores de Tumor/líquido cefalorraquídeo , Neoplasias Encefálicas/líquido cefalorraquídeo , Neoplasias Encefálicas/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Anciano , Diagnóstico Diferencial , Adulto , Linfoma no Hodgkin/líquido cefalorraquídeo , Linfoma no Hodgkin/diagnóstico
3.
Artículo en Inglés | MEDLINE | ID: mdl-39033329

RESUMEN

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

4.
Catheter Cardiovasc Interv ; 104(2): 256-263, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38967206

RESUMEN

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Valor Predictivo de las Pruebas , Diseño de Prótesis , Humanos , Masculino , Femenino , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Adulto , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Adulto Joven , Angiografía por Tomografía Computarizada , Adolescente , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Tomografía Computarizada por Rayos X
5.
medRxiv ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39040184

RESUMEN

Background: Though Aspirin and intravenous immunoglobulin (IVIG) remain the standard treatments for Kawasaki Disease (KD) to minimize coronary artery damage, the duration and dosage of aspirin are inconsistent across hospitals. However, the lack of multi-center randomized trials prevents definitive answers to the impact of high-dose aspirin. Methods: This clinical trial was structured as a prospective, evaluator-blinded, multi-center randomized controlled trial with two parallel arms, aiming to assess the effectiveness of IVIG as a standalone primary therapy of KD in comparison to the combination of IVIG with high-dose aspirin therapy. KD patients were enrolled between September, 2016 and August, 2019. A final cohort of 134 patients were randomly assigned to the standard and test groups with 69 and 65 patients, respectively. The Standard group received IVIG (2 g/kg) along with aspirin (80-100 mg/kg/day) until fever subsided for 48 hours. The test group received IVIG (2 g/kg) alone. Following the initial treatment, both groups received a daily aspirin dose (3-5 mg/kg) for six weeks. The primary outcome measure was the occurrence of coronary artery lesions (CAL) at the 6-8 weeks mark. The secondary outcome is IVIG resistance. Results: The overall rate of CAL in test group decreased from 10.8% at diagnosis to 1.5% and 3.1% at 6 weeks and 6 months, respectively. The CAL rate of standard group declined from 13.0% to 2.9% and 1.4%, with no statistically significant difference (P>0.1) in the frequency of CAL between the two groups. Furthermore, no statistically significant differences were found for treatment (P>0.1) and prevention (P>0.1) effect between the two groups. Conclusions: This marks the first prospective multi-center randomized controlled trial comparing the standard treatment of KD using IVIG plus high-dose aspirin against IVIG alone. Our analysis indicates that addition of high-dose aspirin during initial IVIG treatment is neither statistically significant nor clinically meaningful for CAL reduction. Registration: URL: http://www.clinicaltrials.gov ; identifier: NCT02951234. What is New?: This study represents the first multi-center randomized controlled trial investigating the efficacy of high-dose aspirin or intravenous immunoglobulin (IVIG) during the acute stage of KD. This study assessed the impact of discontinuing high-dose aspirin (80-100 mg/kg/day) on the occurrence of CAL during the acute phase treatment of Kawasaki Disease.No significant differences were observed between high-dose aspirin plus IVIG treatment and IVIG alone treatment in terms of the frequency of abnormal coronary artery abnormalities. Additionally, our analysis revealed no statistically significant differences in either the treatment effect (the number of cases successfully treated) or prevention effect (the prevention of new cases) between these two treatments. What Are the Clinical Implications?: Comparison analysis indicated the non-inferiority between two groups with or without high-dose aspirin.Administering the standard 2 g/kg/day IVIG without high-dose aspirin (80-100 mg/kg/day) during the acute phase therapy for KD does not increase the risk of coronary artery lesions, which are a primary cause of morbidity and mortality in KD patients.Addition of high-dose aspirin during initial IVIG treatment is not statistically significant or clinically meaningful.

6.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38569760

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adulto , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Sistema de Registros , Diseño de Prótesis , Estudios Retrospectivos
7.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38606564

RESUMEN

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Masculino , Femenino , Adolescente , Adulto Joven , Niño , Adulto , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Selección de Paciente , Toma de Decisiones Clínicas , Recuperación de la Función , Hemodinámica
9.
Theranostics ; 14(4): 1602-1614, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38389840

RESUMEN

Background: Markers of aging hold promise in the context of colorectal cancer (CRC) care. Utilizing high-resolution metabolomic profiling, we can unveil distinctive age-related patterns that have the potential to predict early CRC development. Our study aims to unearth a panel of aging markers and delve into the metabolomic alterations associated with aging and CRC. Methods: We assembled a serum cohort comprising 5,649 individuals, consisting of 3,002 healthy volunteers, 715 patients diagnosed with colorectal advanced precancerous lesions (APL), and 1,932 CRC patients, to perform a comprehensive metabolomic analysis. Results: We successfully identified unique age-associated patterns across 42 metabolic pathways. Moreover, we established a metabolic aging clock, comprising 9 key metabolites, using an elastic net regularized regression model that accurately estimates chronological age. Notably, we observed significant chronological disparities among the healthy population, APL patients, and CRC patients. By combining the analysis of circulative carcinoembryonic antigen levels with the categorization of individuals into the "hypo" metabolic aging subgroup, our blood test demonstrates the ability to detect APL and CRC with positive predictive values of 68.4% (64.3%, 72.2%) and 21.4% (17.8%, 25.9%), respectively. Conclusions: This innovative approach utilizing our metabolic aging clock holds significant promise for accurately assessing biological age and enhancing our capacity to detect APL and CRC.


Asunto(s)
Neoplasias Colorrectales , Lesiones Precancerosas , Humanos , Metabolómica , Envejecimiento , Voluntarios Sanos
10.
Pediatr Cardiol ; 45(4): 795-803, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38360921

RESUMEN

This study describes right ventricle (RV) characteristics and right ventricle to pulmonary artery (RV-PA) conduit function pre- and post-repair in patients with tetraology of Fallot with major aortopulmonary collaterals (TOF/MAPCAs). We reviewed patients who underwent single-stage, complete unifocalization, and repair of TOF/MAPCAs between 2006 and 2019 with available pre- and early postoperative echocardiograms. For a subset of patients, 6-12 month follow-up echocardiogram was available. RV and left ventricle (LV) characteristics and RV-PA conduit function were reviewed. Wilcoxon signed rank test and McNemar's test were used. 170 patients were reviewed, 46 had follow-up echocardiograms. Tricuspid valve annular plane systolic excursion (TAPSE) Z-scores were reduced from pre- (Z-score 0.01) to post-repair (Z-score -4.5, p < 0.001), improved but remained abnormal at follow-up (Z-score -4.0, p < 0.001). RV fractional area change (FAC) and LV ejection fraction were not significantly different before and after surgery. Conduit regurgitation was moderate or greater in 11% at discharge, increased to 65% at follow-up. RV-PA conduit failure (severe pulmonary stenosis or severe pulmonary regurgitation) was noted in 61, and 63% had dilated RV (diastolic RV area Z-score > 2) at follow-up. RV dilation correlated with the severe conduit regurgitation (p = 0.018). Longitudinal RV function was reduced after complete repair of TOF/MAPCAs, with decreased TAPSE and preserved FAC and LV ejection fraction. TAPSE improved but did not normalize at follow-up. Severe RV-PA conduit dysfunction was observed prior to discharge in 11% of patients and in 61% at follow-up. RV dilation was common at follow-up, especially in the presence of severe conduit regurgitation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Estenosis de la Válvula Pulmonar , Tetralogía de Fallot , Humanos , Ventrículos Cardíacos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Estudios Retrospectivos , Estenosis de la Válvula Pulmonar/cirugía , Función Ventricular Derecha
11.
Ann Biomed Eng ; 52(5): 1335-1346, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38341399

RESUMEN

Blood pressure gradient ( Δ P ) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient ( ∼ 15 s computation time) compared to 3D simulations ( ∼ 30 h computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.


Asunto(s)
Coartación Aórtica , Humanos , Coartación Aórtica/diagnóstico por imagen , Presión Sanguínea , Angiografía por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo , Simulación por Computador
12.
JACC Clin Electrophysiol ; 10(3): 539-550, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38206260

RESUMEN

BACKGROUND: Evidence for the efficacy of cardiac resynchronization therapy (CRT) in pediatric and congenital heart disease (CHD) has been limited to surrogate outcomes. OBJECTIVES: This study aimed to assess the impact of CRT upon the risk of transplantation or death in a retrospective, high-risk, controlled cohort at 5 quaternary referral centers. METHODS: Both CRT patients and control patients were <21 years of age or had CHD; had systemic ventricular ejection fraction <45%; symptomatic heart failure; and significant electrical dyssynchrony (QRS duration z score >3 or single-site ventricular pacing >40%) at enrollment. Patients with CRT were matched with control patients via 1:1 propensity score matching. CRT patients were enrolled at CRT implantation; control patients were enrolled at the outpatient clinical encounter where inclusion criteria were first met. The primary endpoint was transplantation or death. RESULTS: In total, 324 control patients and 167 CRT recipients were identified. Mean follow-up was 4.2 ± 3.7 years. Upon propensity score matching, 139 closely matched pairs were identified (20 baseline indices). Of the 139 matched pairs, 52 (37.0%) control patients and 31 (22.0%) CRT recipients reached the primary endpoint. On both unadjusted and multivariable Cox regression analysis, the risk reduction associated with CRT for the primary endpoint was significant (HR: 0.40; 95% CI: 0.25-0.64; P < 0.001; and HR: 0.44; 95% CI: 0.28-0.71; P = 0.001, respectively). On longitudinal assessment, the CRT group had significantly improved systemic ventricular ejection fraction (P < 0.001) and shorter QRS duration (P = 0.015), sustained to 5 years. CONCLUSIONS: In pediatric and CHD patients with symptomatic systolic heart failure and electrical dyssynchrony, CRT was associated with improved heart transplantation-free survival.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiopatías Congénitas , Insuficiencia Cardíaca Sistólica , Trasplante de Corazón , Humanos , Niño , Estudios Retrospectivos , Cardiopatías Congénitas/terapia , Insuficiencia Cardíaca Sistólica/terapia
13.
JACC Cardiovasc Interv ; 17(2): 231-244, 2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38267137

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from ∼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvula Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Humanos , Niño , Adulto Joven , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Sistema de Registros
14.
JACC Case Rep ; 26: 102058, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38094173

RESUMEN

The removal of balloon fragments from the pulmonary artery without damaging the pulmonary and tricuspid valves can be difficult. Four cases during transcatheter pulmonary valve replacement are described in which a novel retrieval system was used to facilitate safe removal. (Level of Difficulty: Advanced.).

15.
Biomark Res ; 11(1): 97, 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37957758

RESUMEN

Congenital heart disease (CHD) represents a significant contributor to both morbidity and mortality in neonates and children. There's currently no analogous dried blood spot (DBS) screening for CHD immediately after birth. This study was set to assess the feasibility of using DBS to identify reliable metabolite biomarkers with clinical relevance, with the aim to screen and classify CHD utilizing the DBS. We assembled a cohort of DBS datasets from the California Department of Public Health (CDPH) Biobank, encompassing both normal controls and three pre-defined CHD categories. A DBS-based quantitative metabolomics method was developed using liquid chromatography with tandem mass spectrometry (LC-MS/MS). We conducted a correlation analysis comparing the absolute quantitated metabolite concentration in DBS against the CDPH NBS records to verify the reliability of metabolic profiling. For hydrophilic and hydrophobic metabolites, we executed significant pathway and metabolite analyses respectively. Logistic and LightGBM models were established to aid in CHD discrimination and classification. Consistent and reliable quantification of metabolites were demonstrated in DBS samples stored for up to 15 years. We discerned dysregulated metabolic pathways in CHD patients, including deviations in lipid and energy metabolism, as well as oxidative stress pathways. Furthermore, we identified three metabolites and twelve metabolites as potential biomarkers for CHD assessment and subtypes classifying. This study is the first to confirm the feasibility of validating metabolite profiling results using long-term stored DBS samples. Our findings highlight the potential clinical applications of our DBS-based methods for CHD screening and subtype classification.

17.
Front Mol Biosci ; 10: 1257079, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38028545

RESUMEN

Background: Due to the poor prognosis and rising occurrence, there is a crucial need to improve the diagnosis of Primary Central Nervous System Lymphoma (PCNSL), which is a rare type of non-Hodgkin's lymphoma. This study utilized targeted metabolomics of cerebrospinal fluid (CSF) to identify biomarker panels for the improved diagnosis or differential diagnosis of primary central nervous system lymphoma (PCNSL). Methods: In this study, a cohort of 68 individuals, including patients with primary central nervous system lymphoma (PCNSL), non-malignant disease controls, and patients with other brain tumors, was recruited. Their cerebrospinal fluid samples were analyzed using the Ultra-high performance liquid chromatography - tandem mass spectrometer (UHPLC-MS/MS) technique for targeted metabolomics analysis. Multivariate statistical analysis and logistic regression modeling were employed to identify biomarkers for both diagnosis (Dx) and differential diagnosis (Diff) purposes. The Dx and Diff models were further validated using a separate cohort of 34 subjects through logistic regression modeling. Results: A targeted analysis of 45 metabolites was conducted using UHPLC-MS/MS on cerebrospinal fluid (CSF) samples from a cohort of 68 individuals, including PCNSL patients, non-malignant disease controls, and patients with other brain tumors. Five metabolic features were identified as biomarkers for PCNSL diagnosis, while nine metabolic features were found to be biomarkers for differential diagnosis. Logistic regression modeling was employed to validate the Dx and Diff models using an independent cohort of 34 subjects. The logistic model demonstrated excellent performance, with an AUC of 0.83 for PCNSL vs. non-malignant disease controls and 0.86 for PCNSL vs. other brain tumor patients. Conclusion: Our study has successfully developed two logistic regression models utilizing metabolic markers in cerebrospinal fluid (CSF) for the diagnosis and differential diagnosis of PCNSL. These models provide valuable insights and hold promise for the future development of a non-invasive and reliable diagnostic tool for PCNSL.

18.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37925624

RESUMEN

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo de Salida Ventricular Derecho , Obstrucción del Flujo Ventricular Externo , Humanos , Porcinos , Animales , Prótesis Valvulares Cardíacas/efectos adversos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Diseño de Prótesis
19.
Ann Thorac Surg ; 116(5): 871-907, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37777933

RESUMEN

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Adulto , Humanos , Niño , Estados Unidos , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/etiología , Procedimientos Quirúrgicos Cardíacos/métodos , Atención a la Salud
20.
J Thorac Cardiovasc Surg ; 166(6): 1782-1820, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37777958

RESUMEN

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Adulto , Humanos , Niño , Estados Unidos , Cardiopatías Congénitas/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Atención a la Salud , Consenso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA