Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pain Pract ; 24(1): 91-100, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37626446

RESUMEN

BACKGROUND: Neurologic deficit is known as a rare complication of thoracic spinal cord stimulator (SCS) paddle lead implantation, but many believe its incidence after SCS paddle lead placement is under-reported. It is possible that imaging characteristics may be used to help predict safe paddle lead placement. OBJECTIVE: This imaging study was undertaken to determine the minimum canal diameter required for safe paddle lead placement. METHODS: Patients who underwent thoracic laminotomy for new SCS paddle lead placement from January 2018 to March 2023 were identified retrospectively. Preoperative thoracic canal diameter was measured in the sagittal plane perpendicular to the disc space from T5/6 to T11/12. These thoracic levels were chosen because they span the most common levels targeted for SCS placement. Patients with and without new neurologic deficits were compared using a Mann-Whitney U-test. RESULTS: Of 185 patients initially identified, 180 had thoracic imaging available for review. One (0.5%) and 2 (1.1%) of 185 patients complained of permanent and transient neurologic deficit after thoracic SCS placement, respectively. Patients with neurologic deficits had average canal diameters of <11 mm. The average canal diameter of patients with and without neurologic deficits was 10.2 mm (range 6.1-12.9 mm) and 13.0 mm (range 5.9-20.2), respectively (p < 0.0001). CONCLUSION: Postoperative neurologic deficit is an uncommon complication after thoracic laminotomy for SCS paddle lead placement. The authors recommend ensuring a starting thoracic canal diameter of at least 12 mm to accommodate a SCS paddle lead measuring 2 mm thick to ensure a final diameter of >10 mm. If canal diameter is <12 mm, aggressive undercutting of the lamina, a second laminotomy, or placement of smaller SCS wire leads should be considered.


Asunto(s)
Terapia por Estimulación Eléctrica , Estimulación de la Médula Espinal , Humanos , Estudios Retrospectivos , Electrodos Implantados/efectos adversos , Médula Espinal , Terapia por Estimulación Eléctrica/métodos , Canal Medular/diagnóstico por imagen , Canal Medular/cirugía , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...