Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Vaccine ; 36(37): 5600-5608, 2018 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-30087048

RESUMEN

Because vaccine co-administration can affect elicited immune responses, it is important to evaluate new vaccines in the context of pre-existing vaccination schedules. This is particularly necessary for new pediatric vaccines, as the World Health Organization's infant immunization program already schedules several vaccines to be administered during the first months of life. To facilitate the assessment of inter-vaccine interference, we developed a pediatric vaccine multiplex assay (PVMA) to simultaneously measure antibodies against vaccines commonly administered to infants, including hepatitis B, Haemophilus influenzae type B, diphtheria, tetanus, pertussis, rubella, and respiratory syncytial virus (RSV). Comparison of antibody concentrations determined by enzyme-linked immunosorbent assays (ELISAs) and the PVMA demonstrated that the PVMA is highly sensitive, specific, reproducible, and accurate. Moreover, the PVMA requires half the time to assess a cohort compared to ELISAs, and only costs marginally more. Demonstrating the utility of the assay, we employed the PVMA to assess vaccine interference in the setting of a candidate vaccine, using the infant HIV vaccines from the completed Pediatric AIDS Clinical Trials Group (PACTG) protocols 230 and 326 as examples. There was no substantial difference in antibody concentrations between vaccine and placebo recipients, which suggests that HIV vaccination did not disrupt antibody responses elicited by routine pediatric vaccines. Thus, the PVMA is a reliable, high-throughput technique that requires minimal sample volume to measure multiple antibody concentrations concurrently, and is an efficient alternative to ELISAs for the measurement of vaccine-elicited antibody responses in large cohorts.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Formación de Anticuerpos , Ensayos Analíticos de Alto Rendimiento/métodos , Vacunas/uso terapéutico , Vacunas contra el SIDA/uso terapéutico , Niño , Preescolar , Vacuna contra Difteria, Tétanos y Tos Ferina/uso terapéutico , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Vacunas contra Haemophilus/uso terapéutico , Vacunas contra Hepatitis B/uso terapéutico , Humanos , Esquemas de Inmunización , Lactante , Masculino , Vacuna Antipolio de Virus Inactivados/uso terapéutico , Vacunas Combinadas/uso terapéutico
2.
J Virol ; 92(1)2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29021402

RESUMEN

In the RV144 vaccine trial, IgG responses against the HIV envelope variable loops 1 and 2 (V1V2) were associated with decreased HIV acquisition risk. We previously reported that infants immunized with an MF59-adjuvanted rgp120 vaccine developed higher-magnitude anti-V1V2 IgG responses than adult RV144 vaccinees. To determine whether the robust antibody response in infants is due to differences in vaccine regimens or to inherent differences between the adult and infant immune systems, we compared Env-specific IgG responses in adults and infants immunized with the same MF59- and alum-adjuvanted HIV envelope vaccines. At peak immunogenicity, the magnitudes of the gp120- and V1V2-specific IgG responses were comparable between adults and infants immunized with the alum/MNrgp120 vaccine (gp120 median fluorescence intensities [FIs] in infants = 7,118 and in adults = 11,510, P = 0.070; V1V2 median MFIs of 512 [infants] and 804 [adults], P = 0.50), whereas infants immunized with the MF59/SF-2 rgp120 vaccine had higher-magnitude antibody levels than adults (gp120 median FIs of 15,509 [infants] and 2,290 [adults], P < 0.001; V1V2 median FIs of 23,926 [infants] and 1,538 [adults]; P < 0.001). Six months after peak immunogenicity, infants maintained higher levels Env-specific IgG than adults. Anti-V1V2 IgG3 antibodies that were associated with decreased HIV-1 risk in RV144 vaccinees were present in 43% of MF59/rgp120-vaccinated infants but only in 12% of the vaccinated adults (P = 0.0018). Finally, in contrast to the rare vaccine-elicited Env-specific IgA in infants, rgp120 vaccine-elicited Env-specific IgA was frequently detected in adults. Our results suggest that vaccine adjuvants differently modulate gp120-specific antibody responses in adults and infants and that infants can robustly respond to HIV Env immunization.IMPORTANCE More than 150,000 pediatric HIV infections occur yearly, despite the availability of antiretroviral prophylaxis. A pediatric HIV vaccine could reduce the number of these ongoing infant infections and also prime for long-term immunity prior to sexual debut. We previously reported that immunization of infants with an MF59-adjuvanted recombinant gp120 vaccine induced higher-magnitude, potentially protective anti-V1V2 IgG responses than in adult vaccinees receiving the moderately effective RV144 vaccine. In the present study, we demonstrate that the robust response observed in infants is not due to differences in vaccine regimen or vaccine dose between adults and infants. Our results suggest that HIV vaccine adjuvants may differentially modulate immune responses in adults and infants, highlighting the need to conduct vaccine trials in pediatric populations.


Asunto(s)
Vacunas contra el SIDA/inmunología , Anticuerpos Anti-VIH/sangre , Proteína gp120 de Envoltorio del VIH/inmunología , Inmunogenicidad Vacunal , Inmunoglobulina G/sangre , Escualeno/inmunología , Productos del Gen env del Virus de la Inmunodeficiencia Humana/inmunología , Vacunas contra el SIDA/administración & dosificación , Adyuvantes Inmunológicos , Adulto , Factores de Edad , Anticuerpos Anti-VIH/inmunología , Proteína gp120 de Envoltorio del VIH/administración & dosificación , Infecciones por VIH/inmunología , Infecciones por VIH/prevención & control , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina A/inmunología , Lactante , Polisorbatos/administración & dosificación , Escualeno/administración & dosificación , Vacunación
3.
Clin Vaccine Immunol ; 24(8)2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28566336

RESUMEN

Despite the widespread use of antiretrovirals (ARV), more than 150,000 pediatric HIV-1 infections continue to occur annually. Supplemental strategies are necessary to eliminate pediatric HIV infections. We previously reported that maternal HIV envelope-specific anti-V3 IgG and CD4 binding site-directed antibodies, as well as tier 1 virus neutralization, predicted a reduced risk of mother-to-child transmission (MTCT) of HIV-1 in the pre-ARV era U.S.-based Women and Infants Transmission Study (WITS) cohort. As the majority of ongoing pediatric HIV infections occur in sub-Saharan Africa, we sought to determine if the same maternal humoral immune correlates predicted MTCT in a subset of the Malawian Breastfeeding, Antiretrovirals, and Nutrition (BAN) cohort of HIV-infected mothers (n = 88, with 45 transmitting and 43 nontransmitting). Women and infants received ARV at delivery; thus, the majority of MTCT was in utero (91%). In a multivariable logistic regression model, neither maternal anti-V3 IgG nor clade C tier 1 virus neutralization was associated with MTCT. Unexpectedly, maternal CD4 binding-site antibodies and anti-variable loop 1 and 2 (V1V2) IgG were associated with increased MTCT, independent of maternal viral load. Neither infant envelope (Env)-specific IgG levels nor maternal IgG transplacental transfer efficiency was associated with transmission. Distinct humoral immune correlates of MTCT in the BAN and WITS cohorts could be due to differences between transmission modes, virus clades, or maternal antiretroviral use. The association between specific maternal antibody responses and in utero transmission, which is distinct from potentially protective maternal antibodies in the WITS cohort, underlines the importance of investigating additional cohorts with well-defined transmission modes to understand the role of antibodies during HIV-1 MTCT.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/inmunología , Infecciones por VIH/transmisión , VIH-1/inmunología , Inmunidad Humoral , Transmisión Vertical de Enfermedad Infecciosa , Complicaciones Infecciosas del Embarazo/inmunología , Adulto , Fármacos Anti-VIH/uso terapéutico , Anticuerpos Neutralizantes/inmunología , Lactancia Materna , Estudios de Cohortes , Femenino , Anticuerpos Anti-VIH/biosíntesis , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/virología , Humanos , Inmunoglobulina G/sangre , Lactante , Periodo Periparto , Embarazo , Carga Viral
4.
PLoS One ; 10(2): e0118322, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25714374

RESUMEN

Current use of microbes for metabolic engineering suffers from loss of metabolic output due to natural selection. Rather than combat the evolution of bacterial populations, we chose to embrace what makes biological engineering unique among engineering fields - evolving materials. We harnessed bacteria to compute solutions to the biological problem of metabolic pathway optimization. Our approach is called Programmed Evolution to capture two concepts. First, a population of cells is programmed with DNA code to enable it to compute solutions to a chosen optimization problem. As analog computers, bacteria process known and unknown inputs and direct the output of their biochemical hardware. Second, the system employs the evolution of bacteria toward an optimal metabolic solution by imposing fitness defined by metabolic output. The current study is a proof-of-concept for Programmed Evolution applied to the optimization of a metabolic pathway for the conversion of caffeine to theophylline in E. coli. Introduced genotype variations included strength of the promoter and ribosome binding site, plasmid copy number, and chaperone proteins. We constructed 24 strains using all combinations of the genetic variables. We used a theophylline riboswitch and a tetracycline resistance gene to link theophylline production to fitness. After subjecting the mixed population to selection, we measured a change in the distribution of genotypes in the population and an increased conversion of caffeine to theophylline among the most fit strains, demonstrating Programmed Evolution. Programmed Evolution inverts the standard paradigm in metabolic engineering by harnessing evolution instead of fighting it. Our modular system enables researchers to program bacteria and use evolution to determine the combination of genetic control elements that optimizes catabolic or anabolic output and to maintain it in a population of cells. Programmed Evolution could be used for applications in energy, pharmaceuticals, chemical commodities, biomining, and bioremediation.


Asunto(s)
Bacterias/metabolismo , Ingeniería Metabólica , Redes y Vías Metabólicas , Bacterias/genética , Evolución Biológica , Técnicas Biosensibles , Dosificación de Gen , Ingeniería Genética , Aptitud Genética , Variación Genética , Modelos Biológicos , Plásmidos/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...