Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Article En | MEDLINE | ID: mdl-38843820

OBJECTIVE: Rock-back is a reported complication following tibial plateau levelling osteotomy (TPLO), whereby tibial plateau angle (TPA) increases postoperatively. The mechanism of rock-back is not fully understood, although a recent ex vivo investigation demonstrated that osteotomy exit cut angle (ECA) and inclination of the plate in the sagittal plane might be risk factors. The purpose of this study was to explore these relationships in a clinical dog population. We hypothesized that dogs with rock-back would have a higher degree of plate inclination and downward ECA compared with those without rock-back. MATERIALS AND METHODS: Medical records and radiographs of dogs that underwent TPLO between January 2021 and January 2022 were retrospectively reviewed. TPA was recorded preoperatively, postoperatively, and at follow-up. Plate inclination, ECA, and descriptive data were collected. Observers measuring TPA were blinded to other variables. Rock-back was defined as a change in TPA ≥ 2. RESULTS: Ninety-five TPLO procedures met the inclusion criteria (n = 87 dogs). Rock-back was identified in 21% of TPLOs (n = 20/95). The mean increase in TPA in the rock-back group was 3.2 ± 2.6. Plate inclination and ECA were not correlated with the presence of rock-back. Descriptive variables did not have a significant correlation with rock-back. CONCLUSION: Plate inclination and ECA did not have a relationship with rock-back when defined as a postoperative TPA change ≥2 degrees, in this clinical retrospective study.

2.
Am J Vet Res ; 81(9): 755-759, 2020 Sep.
Article En | MEDLINE | ID: mdl-33112165

OBJECTIVE: To compare the bursting strength of the uterine horns (UHs) and cervical-vestibule junction (CVJs) of rabbits following sealing with a vessel-sealing device (VSD) or encircling ligatures. SAMPLE: UHs and CVJs collected from 30 rabbit (Oryctolagus cuniculus) cadavers. PROCEDURES: UHs and CVJs were randomly assigned to sealing with encircling Miller knot ligatures (LIG; n = 10 CVJs and 20 UHs) or a VSD (12 CVJs and 24 UHs). Lumens were infused with saline (0.9% NaCl) solution under pressure until seals burst or to a maximum pressure of 300 mm Hg. RESULTS: For CVJs, median (range) bursting pressure of the LIG and VSD groups was > 300 mm Hg (224 to > 300 mm Hg) and 35 mm Hg (0 to 60 mm Hg), respectively. Five of 12 CVJs in the VSD group failed at pressures < 33 mm Hg. For UHs, median (range) bursting pressure of the LIG and VSD groups was 255 mm Hg (120 to > 300 mm Hg) and 154 mm Hg (range, 44 to 202 mm Hg), respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The evaluated VSD was effective in sealing UHs at bursting pressures well in excess of expected physiologic pressures, indicating that the VSD may be useful for ovariectomy procedures in rabbits. However, CVJ seals created with the VSD were ineffective and could potentially burst at low pressures, which could predispose to urine entering the abdomen. Given these results, we do not recommend sealing of the CVJ with a VSD for ovariohysterectomy in rabbits.


Hysterectomy , Surgical Instruments , Animals , Female , Hysterectomy/veterinary , Ligation/veterinary , Ovariectomy/veterinary , Rabbits
...