Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 31(2): 1943-1957, 2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36785218

RESUMEN

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs with large detection area have recently become commercially available, enabling applications where the photon flux is low both temporarily and spatially. On the other hand, several drawbacks exist in the usage of SiPMs such as a higher dark count rate, many readout channels, slow response time, and optical crosstalk; therefore, users need to carefully consider the trade-offs. This work presents a SiPM-embedded compact large-area photon detection module. Various techniques are adopted to overcome the disadvantages of SiPMs so that it can be generally utilized as an upgrade from a PMT. A simple cooling component and recently developed optical crosstalk suppression method are adopted to reduce the noise which is more serious for larger-area SiPMs. A dedicated readout circuit increases the response frequency and reduces the number of readout channels. We favorably compare this design with a conventional PMT and obtain both higher photon detection efficiency and larger-area acceptance.

2.
Opt Express ; 29(11): 16914-16926, 2021 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-34154244

RESUMEN

We propose and study a method of optical crosstalk suppression for silicon photomultipliers (SiPMs) using optical filters. We demonstrate that attaching absorptive visible bandpass filters to the SiPM can substantially reduce the optical crosstalk. Measurements suggest that the absorption of near infrared light is important to achieve this suppression. The proposed technique can be easily applied to suppress the optical crosstalk in SiPMs in cases where filtering near infrared light is compatible with the application.

3.
Open Forum Infect Dis ; 8(2): ofaa610, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33575418

RESUMEN

BACKGROUND: Due to unprecedented shortages in N95 filtering facepiece respirators, healthcare systems have explored N95 reprocessing. No single, full-scale reprocessing publication has reported an evaluation including multiple viruses, bacteria, and fungi along with respirator filtration and fit. METHODS: We explored reprocessing methods using new 3M 1860 N95 respirators, including moist (50%-75% relative humidity [RH]) heat (80-82°C for 30 minutes), ethylene oxide (EtO), pulsed xenon UV-C (UV-PX), hydrogen peroxide gas plasma (HPGP), and hydrogen peroxide vapor (HPV). Respirator samples were analyzed using 4 viruses (MS2, phi6, influenza A virus [IAV], murine hepatitis virus [MHV)]), 3 bacteria (Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus spores, and vegetative bacteria), and Aspergillus niger. Different application media were tested. Decontaminated respirators were evaluated for filtration integrity and fit. RESULTS: Heat with moderate RH most effectively inactivated virus, resulting in reductions of >6.6-log10 MS2, >6.7-log10 Phi6, >2.7-log10 MHV, and >3.9-log10 IAV and prokaryotes, except for G stearothermohphilus. Hydrogen peroxide vapor was moderately effective at inactivating tested viruses, resulting in 1.5- to >4-log10 observable inactivation. Staphylococcus aureus inactivation by HPV was limited. Filtration efficiency and proper fit were maintained after 5 cycles of heat with moderate RH and HPV. Although it was effective at decontamination, HPGP resulted in decreased filtration efficiency, and EtO treatment raised toxicity concerns. Observed virus inactivation varied depending upon the application media used. CONCLUSIONS: Both moist heat and HPV are scalable N95 reprocessing options because they achieve high levels of biological indicator inactivation while maintaining respirator fit and integrity.

4.
Appl Biosaf ; 26(2): 80-89, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36034691

RESUMEN

Introduction: The coronavirus disease 2019 (COVID-19) pandemic has caused a global shortage of single-use N95 filtering facepiece respirators (FFRs). A combination of heat and humidity is a promising method for N95 FFR decontamination in crisis-capacity conditions; however, an understanding of its effect on viral inactivation and N95 respirator function is crucial to achieving effective decontamination. Objective: We reviewed the scientific literature on heat-based methods for decontamination of N95 FFRs contaminated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and viral analogues. We identified key parameters for SARS-CoV-2 bioburden reduction while preserving N95 fit and filtration, as well as methods that are likely ineffective. Key Findings: Viral inactivation by humid heat is highly sensitive to temperature, humidity, duration of exposure, and the local microenvironment (e.g., dried saliva). A process that achieves temperatures of 70-85°C and relative humidity >50% for at least 30 min is likely to inactivate SARS-CoV-2 (>3-log reduction) on N95 respirators while maintaining fit and filtration efficiency for three to five cycles. Dry heat is significantly less effective. Microwave-generated steam is another promising approach, although less studied, whereas 121°C autoclave treatments may damage some N95 FFRs. Humid heat will not inactivate all microorganisms, so reprocessed N95 respirators should be reused only by the original user. Conclusions: Effective bioburden reduction on N95 FFRs during the COVID-19 pandemic requires inactivation of SARS-CoV-2 and preservation of N95 fit and filtration. The literature suggests that humid heat protocols can achieve effective bioburden reduction. Proper industrial hygiene, biosafety controls, and clear protocols are required to reduce the risks of N95 reprocessing and reuse.

5.
PLoS One ; 15(7): e0234851, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32609741

RESUMEN

A lack of N95 Filtering Facepiece Respirators (FFRs) during the COVID-19 crisis has placed healthcare workers at risk. It is important for any N95 reuse strategy to determine the effects that proposed protocols would have on the physical functioning of the mask, as well as the practical aspects of implementation. Here we propose and implement a method of heating N95 respirators with moisture (85°C, 60-85% humidity). We test both mask filtration efficiency and fit to validate this process. Our tests focus on the 3M 1860, 3M 1870, and 3M 8210 Plus N95 models. After five cycles of the heating procedure, all three respirators pass both quantitative fit testing (score of >100) and show no degradation of mask filtration efficiency. We also test the Chen Heng V9501 KN95 and HKYQ N95 finding no degradation of mask filtration efficiency, however even for unheated masks these scored <50 for every fit test. The heating method presented here is scalable from individual masks to over a thousand a day with a single industrial convection oven, making this method practical for local application inside health-care facilities.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/epidemiología , Descontaminación/métodos , Equipo Reutilizado , Calefacción/métodos , Humedad , Máscaras/virología , Neumonía Viral/epidemiología , Dispositivos de Protección Respiratoria/virología , COVID-19 , Infecciones por Coronavirus/virología , Filtración/instrumentación , Humanos , Ensayo de Materiales/métodos , Exposición Profesional/prevención & control , Pandemias , Neumonía Viral/virología , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...