Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-34780012

RESUMEN

To evaluate the accuracy of coronary artery calcium (CAC) scoring at various tube voltages and different monoenergetic image reconstructions on a first-generation dual-source photon-counting detector CT (PCD-CT). A commercially available anthropomorphic chest phantom with calcium inserts was scanned at different tube voltages (90 kV, Sn100kV, 120 kV, and Sn140kV) on a first-generation dual-source PCD-CT system with quantum technology using automatic exposure control with an image quality (IQ) level of 20. The same phantom was also scanned on a conventional energy-integrating detector CT (120 kV; weighted filtered back projection) for reference. Extension rings were used to emulate different patient sizes. Virtual monoenergetic images at 65 keV and 70 keV applying different levels of quantum iterative reconstruction (QIR) were reconstructed from the PCD-CT data sets. CAC scores were determined and compared to the reference. Radiation doses were noted. At an IQ level of 20, radiation doses ranged between 1.18 mGy and 4.64 mGy, depending on the tube voltage and phantom size. Imaging at 90 kV or Sn100kV was associated with a size-dependent radiation dose reduction between 23% and 48% compared to 120 kV. Tube voltage adapted image reconstructions with 65 keV and QIR 3 at 90 kV and with 70 keV and QIR 1 at Sn100kV allowed to calculate CAC scores comparable to conventional EID-CT scans with a percentage deviation of ≤ 5% for all phantom sizes. Our phantom study indicates that CAC scoring with dual-source PCD-CT is accurate at various tube voltages, offering the possibility of substantial radiation dose reduction.

2.
Clin Radiol ; 74(9): 731.e11-731.e19, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31130228

RESUMEN

AIM: To evaluate the feasibility of T1-weighted (T1W) three-dimensional (3D) fat saturated Cartesian volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) sequence for the diagnosis of aortitis in patients with suspected large vessel vasculitis (LVV) applying fully integrated 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) positron-emission tomography (PET)/MRI. MATERIAL AND METHODS: Fourteen patients with aortitis and 14 patients with a negative study for aortitis using 18F-FDG PET as the standard of reference for the evaluation of inflammatory aortic involvement were included retrospectively. All patients were imaged at 3 T using T1W VIBE pre- and post-contrast. Four aortic segments were evaluated for image quality (IQ), diagnostic confidence (DC), and the degree of inflammatory activity (IA) using a Likert scale. Binomial and generalised estimating equation model tests were used to assess the diagnostic performance of T1W VIBE. Cohen's k was applied to test for interobserver reproducibility with respect to IA. Spearman's rank correlation coefficient was calculated to examine correlations between IQ, DC, IA, and PET results. RESULTS: On a patient- and segment-based analysis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 85.7% and 59.8%, 100% and 100%, 100% and 100%, 87.5% and 68%, and 92.9% and 82.1%, respectively. IQ and DC were acceptable to good in all examinations and substantial interobserver agreement was observed for IA (Cohen's k = 0.69). IQ and DC as well as IA and 18F-FDG vessel wall uptake were significantly correlated (r=0.763 and 0.679, respectively; p<0.0001). CONCLUSION: T1W 3D fat saturated VIBE MRI allows diagnosis of aortitis and may aid in the management of patients with suspected LVV.


Asunto(s)
Aortitis/diagnóstico por imagen , Imagen Multimodal , Anciano , Contencion de la Respiración , Estudios de Factibilidad , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiofármacos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Vasculitis/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...