Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 13 de 13
1.
Chemistry ; 28(17): e202200655, 2022 Mar 22.
Article En | MEDLINE | ID: mdl-35277903

Invited for the cover of this issue is Assaf Friedler, Shlomo Yitzchaik and co-workers at the Hebrew University of Jerusalem and the Academia Sinica. The image depicts a new approach for electrochemical kinase sensing that does not rely on phosphorylation. The kinase binds a peptide layer, which undergoes rearrangement, resulting in the permeation of redox-active species through the layer and electrochemical sensing. Read the full text of the article at 10.1002/chem.202104227.


Peptides , Catalytic Domain , Humans
2.
Biosens Bioelectron ; 207: 114177, 2022 Jul 01.
Article En | MEDLINE | ID: mdl-35305389

Kinases are important cancer biomarkers and are conventionally detected based on their catalytic activity. Kinases regulate cellular activities by phosphorylation of motif-specific multiple substrate proteins, resulting in a lack of selectivity of activity-based kinase biosensors. We present an alternative approach of sensing kinases based on the interactions of their allosteric docking sites with a specific partner protein. The new approach was demonstrated for the ERK2 kinase and its substrate ELK-1. A peptide derived from ELK-1 was bound to a gold electrode and ERK2 sensing was performed by electrochemical impedance spectroscopy. We performed a detailed analysis of the interaction between the ELK-1 peptide and the kinase on gold surfaces. Atomic force microscopy, variable angle spectroscopic ellipsometry, X-ray Photoelectron Spectroscopy, and polarization modulation IR reflection-absorption spectroscopy analysis of the gold surface revealed the adsorbed layer of the ERK2 on the peptide monolayer. The sensors showed a high level of target selectivity for ERK2 compared to the p38γ kinase and BSA. ERK2 was detected in its cellular concentration range, 0.5-2.0 µM, and the limit of detection was calculated to be 0.35 µM. Using the flexibility of peptide design, our method is generic for developing sensitive and substrate-specific biosensors and other disease-related enzymes based on their interactions.


Biosensing Techniques , Amino Acid Sequence , Gold , Peptides/chemistry , Phosphorylation
3.
Chemistry ; 28(17): e202104227, 2022 Mar 22.
Article En | MEDLINE | ID: mdl-35038192

The role kinases play in regulating cellular processes makes them potential biomarkers for detecting the onset and prognosis of various diseases, including many types of cancer. Current kinase biosensors, including electrochemical and radiometric methods, rely on sensing the ATP-dependant enzymatic phosphorylation reaction. Here we introduce a new type of interaction-based electrochemical kinase biosensor that does not require any chemical labelling or modification. The basis for sensing is the interactions between the catalytic site of the kinase and the phosphorylation site of its substrate rather than the phosphorylation reaction. We demonstrated this concept with the ERK2 kinase and its substrate protein HDGF, which is involved in lung cancer. A peptide monolayer derived from the HDGF phosphorylation site was adsorbed onto a gold electrode and was used to sense ERK2 without ATP. The sensitivity of the assay was down to 10 nM of ERK2, corresponding with the range of its cellular concentrations. Surface chemistry analysis confirmed that ERK2 was bound to the HDGF peptide monolayer. This increased the permeability of redox-active species through the monolayer and resulted in ERK2 electrochemical sensing. Since our detection approach is based on protein-protein interactions and not on the enzymatic reaction, it can be further utilized for more selective detection of different types of enzymes.


Biosensing Techniques , Catalytic Domain , Gold , Peptides , Phosphorylation
4.
Chem Commun (Camb) ; 57(51): 6233-6236, 2021 Jun 24.
Article En | MEDLINE | ID: mdl-34095904

Self-assembly of photo-responsive molecules is a robust technology for reversibly tuning the properties of functional materials. Herein, we probed the crucial role of surface-adsorbate interactions on the adsorption geometry of stilbene-functionalized N-heterocyclic carbenes (stilbene-NHCs) monolayers and its impact on surface potential. Stilbene-NHCs on Au film accumulated in a vertical orientation that enabled high photoisomerization efficiency and reversible changes in surface potential. Strong metal-adsorbate interactions led to flat-lying adsorption geometry of stilbene-NHCs on Pt film, which quenched the photo-isomerization influence on surface potential. It is identified that photo-induced response can be optimized by positioning the photo-active group in proximity to weakly-interacting surfaces.

5.
Sci Rep ; 11(1): 7051, 2021 03 29.
Article En | MEDLINE | ID: mdl-33782419

Peptides are commonly used as biosensors for analytes such as metal ions as they have natural binding preferences. In our previous peptide-based impedimetric metal ion biosensors, a monolayer of the peptide was anchored covalently to the electrode. Binding of metal ions resulted in a conformational change of the oxytocin peptide in the monolayer, which was measured using electrochemical impedance spectroscopy. Here, we demonstrate that sensing can be achieved also when the oxytocin is non-covalently integrated into an alkanethiol host monolayer. We show that ion-binding cause morphological changes to the dense host layer, which translates into enhanced impedimetric signals compared to direct covalent assembly strategies. This biosensor proved selective and sensitive for Zn2+ ions in the range of nano- to micro-molar concentrations. This strategy offers an approach to utilize peptide flexibility in monitoring their response to the environment while embedded in a hydrophobic monolayer.


Oxytocin/chemistry , Sulfhydryl Compounds/chemistry , Zinc/analysis , Biosensing Techniques , Dielectric Spectroscopy/methods , Hydrophobic and Hydrophilic Interactions , Limit of Detection , Microscopy, Atomic Force/methods
6.
Biosens Bioelectron ; 172: 112762, 2021 Jan 15.
Article En | MEDLINE | ID: mdl-33142198

Sialylated glycans and glycoproteins are involved in cellular communication and are crucial for distinguishing between signal pathways. Sialylation levels and patterns modulate recognition events and are regulated by the enzymatic activity of sialyltransferases and neuraminidases. Abnormal activity of these enzymes is related to diseases such as cancer and viral infection. Monitoring these enzymatic activities offers valuable diagnostic tools. This work presents an impedimetric biosensing platform for following and detecting sialylation and desialylation processes. This platform is based on a native biantennary N-glycan substrate attached to a glassy carbon electrode. Changes in the molecular layer, as a result of enzymatic reactions, were detected by electrochemical impedance spectroscopy, displaying high sensitivity to the enzymatic surface reactions. Increase in the molecular layer roughness in response to the sialylation was visualized using atomic force microscopy. After enzymatic sialylation, the presence of sialic acid was confirmed using cyclic voltammetry by coupling of the redox active marker aminoferrocene. The sialylation showed selectivity toward the N-glycan compared to another glycan substrate. A time dependent sialylation was followed by electrochemical impedance spectroscopy, proving that the new system can be applied to evaluate the enzymatic kinetics. Our findings suggest that analyzing sialylation processes using this platform can become a useful tool for the detection of pathological states and pathogen invasion.


Biosensing Techniques , Dielectric Spectroscopy , N-Acetylneuraminic Acid , Polysaccharides , Sialyltransferases
7.
J Mater Chem B ; 8(1): 155-160, 2020 01 07.
Article En | MEDLINE | ID: mdl-31782469

Oxytocin is a peptide hormone with high affinity to both Zn2+ and Cu2+ ions compared to other metal ions. This affinity makes oxytocin an attractive recognition layer for monitoring the levels of these essential ions in biofluids. Native oxytocin cannot differentiate between Cu2+ and Zn2+ ions and hence it is not useful for sensing Zn2+ in the presence of Cu2+. We elucidated the effect of the terminal amine group of oxytocin on the affinity toward Cu2+ using theoretical calculations. We designed a new Zn2+ selective oxytocin-based biosensor that utilizes the terminal amine for surface anchoring, also preventing the response to Cu2+. The biosensor shows exceptional selectivity and very high sensitivity to Zn2+ in impedimetric biosensing. This study shows for the first time an oxytocin derived sensor that can be used directly for sensing Zn2+ in the presence of Cu2+.


Biosensing Techniques , Oxytocin/analysis , Zinc/metabolism , Gold/chemistry , Protein Binding , Thioctic Acid/chemistry
8.
Langmuir ; 35(34): 11114-11122, 2019 08 27.
Article En | MEDLINE | ID: mdl-31361147

Peptides are very common recognition entities that are usually attached to surfaces using multistep processes. These processes require modification of the native peptides and of the substrates. Using functional groups in native peptides for their assembly on surfaces without affecting their biological activity can facilitate the preparation of biosensors. Herein, we present a simple single-step formation of native oxytocin monolayer on gold surface. These surfaces were characterized by atomic force spectroscopy, spectroscopic ellipsometry, and X-ray photoelectron spectroscopy. We took advantage of the native disulfide bridge of the oxytocin for anchoring the peptide to the Au surface, while preserving the metal-ion binding properties. Self-assembled oxytocin monolayer was used by electrochemical impedance spectroscopy for metal-ion sensing leading to subnanomolar sensitivities for zinc or copper ions.

9.
Chemistry ; 25(52): 12083-12090, 2019 Sep 18.
Article En | MEDLINE | ID: mdl-31155776

Sulfated saccharides are an essential part of extracellular matrices, and they are involved in a large number of interactions. Sulfated saccharide matrices in organisms accumulate heavy metal ions in addition to other essential metal ions. Accumulation of heavy metal ions alters the function of the organisms and cells, resulting in severe and irreversible damage. The effect of the sulfation pattern of saccharides on heavy metal binding preferences is enigmatic because the accessibility to structurally defined sulfated saccharides is limited and because standard analytical techniques cannot be used to quantify these interactions. We developed a new strategy that combines enzymatic and chemical synthesis with surface chemistry and label-free electrochemical sensing to study the interactions between well-defined sulfated saccharides and heavy metal ions. By using these tools we showed that the sulfation pattern of hyaluronic acid governs their heavy metal ions binding preferences.

10.
Langmuir ; 35(8): 2997-3004, 2019 Feb 26.
Article En | MEDLINE | ID: mdl-30707589

The ability to tune the electronic properties of oxide-bearing semiconductors such as Si/SiO2 or transparent metal oxides such as indium-tin oxide (ITO) is of great importance in both electronic and optoelectronic device applications. In this work, we describe a process that was conducted on n-type Si/SiO2 and ITO to induce changes in the substrate work function (WF). The substrates were modified by a two-step synthesis comprising a covalent attachment of coupling agents' monolayer followed by in situ anchoring reactions of polarizable chromophores. The coupling agents and chromophores were chosen with opposite dipole orientations, which enabled the tunability of the substrates' WF. In the first step, two coupling agents with opposite molecular dipole were assembled. The coupling agent with a negative dipole induced a decrease in WF of modified substrates, while the coupling agent with a positive dipole produced an increase in WFs of both ITO and Si substrates. The second modification step consisted of in situ anchoring reaction of polarizable chromophores with opposite dipoles to the coupling layer. This modification led to an additional change in the WFs of both Si/SiO2 and ITO substrates. The WF was measured by contact potential difference and modeled by density functional theory-based theoretical calculations of the WF for each of the assembly steps. A good fit was obtained between the calculated and experimental trends. This ability to design and tune the WF of ITO substrates was implemented in an organic electronic device with improved I- V characteristics in comparison to a bare ITO-based device.

11.
ACS Appl Mater Interfaces ; 9(51): 44873-44879, 2017 Dec 27.
Article En | MEDLINE | ID: mdl-29206026

In this work, we demonstrate the tunability of electronic properties of Si/SiO2 substrates by molecular and ionic surface modifications. The changes in the electronic properties such as the work function (WF) and electron affinity were experimentally measured by the contact potential difference technique and theoretically supported by density functional theory calculations. We attribute these molecular electronic effects mainly to the variations of molecular and surface dipoles of the ionic and neutral species. We have previously shown that for the alkylhalide monolayers, changing the tail group from Cl to I decreased the WF of the substrate. Here, we report on the opposite trend of WF changes, that is, the increase of the WF, obtained by using the anions of these halides from Cl- to I-. This trend was observed on self-assembled alkylammonium halide (-NH3+ X-, where X- = Cl-, Br-, or I-) monolayer-modified substrates. The monolayer's formation was supported by ellipsometry measurements, X-ray photoelectron spectroscopy, and atomic force microscopy. Comparison of the theoretical and experimental data suggests that the ionic surface dipole depends mainly on the polarizability and the position of the counter halide anion along with the organization and packaging of the layer. The described ionic modification can be easily used for facile tailoring and design of the electronic properties Si/SiO2 substrates for various device applications.

12.
Sci Rep ; 7(1): 9498, 2017 08 25.
Article En | MEDLINE | ID: mdl-28842708

Copper ions play a major role in biological processes. Abnormal Cu2+ ions concentrations are associated with various diseases, hence, can be used as diagnostic target. Monitoring copper ion is currently performed by non-portable, expensive and complicated to use equipment. We present a label free and a highly sensitive electrochemical ion-detecting biosensor based on a Gly-Gly-His tripeptide layer that chelate with Cu2+ ions. The proposed sensing mechanism is that the chelation results in conformational changes in the peptide that forms a denser insulating layer that prevents RedOx species transfer to the surface. This chelation event was monitored using various electrochemical methods and surface chemistry analysis and supported by theoretical calculations. We propose a highly sensitive ion-detection biosensor that can detect Cu2+ ions in the pM range with high SNR parameter.

13.
ACS Omega ; 2(12): 8770-8778, 2017 Dec 31.
Article En | MEDLINE | ID: mdl-29302631

Zinc and copper are essential metal ions for numerous biological processes. Their levels are tightly maintained in all body organs. Impairment of the Zn2+ to Cu2+ ratio in serum was found to correlate with many disease states, including immunological and inflammatory disorders. Oxytocin (OT) is a neuropeptide, and its activity is modulated by zinc and copper ion binding. Harnessing the intrinsic properties of OT is one of the attractive ways to develop valuable metal ion sensors. Here, we report for the first time an OT-based metal ion sensor prepared by immobilizing the neuropeptide onto a glassy carbon electrode. The developed impedimetric biosensor was ultrasensitive to Zn2+ and Cu2+ ions at physiological pH and not to other biologically relevant ions. Interestingly, the electrochemical impedance signal of two hemicircle systems was recorded after the attachment of OT to the surface. These two semicircles suggest two capacitive regions that result from two different domains in the OT monolayer. Moreover, the change in the charge-transfer resistance of either Zn2+ or Cu2+ was not similar in response to binding. This suggests that the metal-dependent conformational changes of OT can be translated to distinct impedimetric data. Selective masking of Zn2+ and Cu2+ was used to allow for the simultaneous determination of zinc to copper ions ratio by the OT sensor. The OT sensor was able to distinguish between healthy control and multiple sclerosis patients diluted sera samples by determining the Zn/Cu ratio similar to the state-of-the-art techniques. The OT sensor presented herein is likely to have numerous applications in biomedical research and pave the way to other types of neuropeptide-derived sensors.

...