Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
JACC Clin Electrophysiol ; 10(6): 1161-1174, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38661603

RESUMEN

BACKGROUND: Management of acute myocarditis (AM) patients experiencing ventricular arrhythmia (VA) during acute illness is controversial, especially regarding early implantable cardioverter-defibrillator (ICD) implantation. OBJECTIVES: The purpose of this study was to evaluate the prevalence of and find predictors for long-term sustained VA recurrence and overall mortality among AM patients with VA. METHODS: This was a multicenter retrospective analysis of AM patients (verified by cardiac magnetic resonance imaging or myocardial biopsy) with documented VA during the acute illness ("initial VA"). Patients with history of myocardial infarction, heart failure, or VA were excluded. The study endpoint was a composite of sustained VA and overall mortality during follow-up. RESULTS: The study included 69 AM patients with initial VA: sustained monomorphic ventricular tachycardia (MMVT) (n = 25), sustained polymorphic ventricular tachycardia (VT)/ventricular fibrillation (n = 13), and nonsustained VT (n = 31). Age was 44 ± 13 years, and 23 of 69 (33.3%) were women. During median follow-up of 5.5 years, 27 of 69 (39%) patients reached the composite endpoint including sustained VA (n = 24) and death (n = 11). Initial MMVT, predischarge left ventricular dysfunction (left ventricular ejection fraction <50%), and anteroseptal delayed enhancement on cardiac magnetic resonance imaging were significantly associated with the composite endpoint. On multivariable analysis, initial MMVT (HR: 5.17; 95% CI: 1.81-14.6; P = 0.001) and predischarge LV dysfunction (HR: 4.57; 95% CI: 1.83-11.5; P = 0.005) were independently associated with the composite endpoint. Using these 2 predictors, we could delineate subgroups with low (∼4%), medium (∼42%), and high (∼82%) 10-year incidence of composite endpoint. CONCLUSIONS: AM patients presenting with VA have high incidence of sustained VA recurrence and mortality posthospitalization. Initial MMVT and predischarge LV dysfunction are independently associated with VA recurrence and mortality. Implantable cardioverter-defibrillator implantation may be considered in such high-risk patients.


Asunto(s)
Miocarditis , Recurrencia , Taquicardia Ventricular , Humanos , Femenino , Masculino , Miocarditis/epidemiología , Miocarditis/complicaciones , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/terapia , Incidencia , Desfibriladores Implantables , Enfermedad Aguda , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/terapia
3.
Am J Cardiol ; 211: 17-28, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37879381

RESUMEN

The current guidelines advocate prophylactic implantable cardioverter-defibrillator (ICD) for all patients with symptomatic heart failure (HF) with low left ventricular ejection fraction. Because many patients will never use their device, a score delineating subgroups with differential ICD benefit is crucial. We aimed to evaluate the MADIT-II-based Risk Stratification Score (MRSS) feasibility to delineate the ICD survival benefit in a nationwide registry of patients with HF with prophylactic ICDs. Accordingly, all Israeli patients with HF with prophylactic ICD/cardiac resynchronization therapy defibrillators were categorized into MRSS-based risk subgroups. The study end points included overall mortality, sustained ventricular arrhythmia (VA), and a competing risk of VA (potential preventable arrhythmic death, where ICD could benefit survival) versus nonarrhythmic death. Potential ICD survival benefit was estimated by the area between these cumulative incidence curves. In 2,177 patients with HF implanted prophylactic device, 189 patients (8.7%) had VA and 316 (14.5%) died during a median follow-up of 2.9 years. The MRSS risk subgroups were significantly associated with overall mortality (p <0.001) and weakly with VA (p = 0.3). The competing risk analysis of VA versus nonarrhythmic death revealed a significantly shorter duration (p <0.001) and smaller magnitude of ICD survival benefit with increased risk subgroups, yielding an estimated 76, 60, 38, and 0 life days gained from prophylactic ICD implant during a 5-year follow-up for the MRSS low-, intermediate-, high-, and very high-risk subgroups, respectively (p for trend <0.05). In conclusion, MRSS use in a nationwide registry of patients with ischemic and nonischemic cardiomyopathy, revealed subgroups with differing ICD survival benefit, suggesting it could help evaluate prophylactic ICD survival benefit.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Factores de Riesgo , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Medición de Riesgo , Sistema de Registros , Prevención Primaria , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37622591

RESUMEN

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Asunto(s)
Fármacos Cardiovasculares , Humanos , Electrónica , Corazón , Tecnología , Manejo de la Enfermedad
5.
J Clin Med ; 12(6)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36983442

RESUMEN

BACKGROUND: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. AIM: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. METHODS AND RESULTS: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). CONCLUSION: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.

6.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36635857

RESUMEN

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Humanos , Bloqueo de Rama , Taquicardia Ventricular/etiología , Taquicardia Ventricular/complicaciones , Ventrículos Cardíacos , Electrocardiografía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico
8.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38225168

RESUMEN

AIMS: Conduction abnormalities post-transcatheter aortic valve implantation (TAVI) are common. Post-TAVI PR prolongation was mainly studied as an adjunct to new-onset bundle branch block. The net effect of isolated PR prolongation (IPRP) without post-TAVI QRS changes is not well known. The aim of this study was to define the incidence and clinical significance of post-TAVI IPRP. METHODS AND RESULTS: A total of 1108 consecutive TAVI patients were reviewed. Patients with IPRP were compared with patients without post-TAVI electrocardiogram (ECG) changes. Clinical outcomes included permanent pacemaker implantation (PPI) and overall mortality. A total of 146 patients with IPRP were compared with 290 patients without post-TAVI ECG changes. At 1 year follow-up, 4 (2.7%) and 7 (2.4%) patients underwent PPI (P = 0.838) and 10 (6.8%) and 25 (8.6%) died (P = 0.521), from the study and control groups, respectively. No patient with IPRP and narrow QRS underwent PPI during 1 year post-TAVI, and all death events were non-cardiac except one unknown cause. Permanent pacemaker implantation rates among patients with IPRP and wide QRS were higher (n = 4, 12.1%), compared with patients with wide QRS without post-TAVI ECG change (n = 3, 4%) however not reaching statistical significance (P = 0.126). Multivariate Cox proportional hazards model demonstrated that in patients with narrow QRS, neither PR prolongation nor baseline or maximal PR intervals was associated with the combined endpoint of PPI and mortality. However, in patients with wide QRS, baseline PR intervals and QRS width, but not PR prolongation were associated with the combined outcome. CONCLUSION: Post-TAVI IPRP in patients with narrow QRS is not associated with adverse outcome. This finding may translate clinically into a more permissive approach to these patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Marcapaso Artificial/efectos adversos , Incidencia , Relevancia Clínica , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Electrocardiografía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos
9.
Harefuah ; 161(7): 454-457, 2022 Jul.
Artículo en Hebreo | MEDLINE | ID: mdl-35833433

RESUMEN

INTRODUCTION: For many years routine screening of athletes in Israel includes frequently performed ECGs and exercise tests that overload the system with questionable benefits. The purpose of the current document is to reevaluate the need for pre-participation testing and establish new evidence-based guidelines. It should be noted that our proposal for a change of approach relates only to subjects whose health questionnaire is normal, who do not have a family history of sudden and unexpected death at an early age, or a family history of hereditary heart disease and whose physical examination from a cardiovascular point of view is normal.


Asunto(s)
Enfermedades Cardiovasculares , Deportes , Atletas , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/prevención & control , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Humanos , Israel , Tamizaje Masivo , Examen Físico , Organización Mundial de la Salud
14.
J Cardiovasc Electrophysiol ; 33(4): 618-625, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35118762

RESUMEN

BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Computadores , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Imagenología Tridimensional/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Tomografía Computarizada por Rayos X
16.
Europace ; 24(5): 817-827, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34652415

RESUMEN

AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads. METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success. CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Humanos , Marcapaso Artificial/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
18.
Europace ; 24(1): 165-172, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34455442

RESUMEN

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Marcapaso Artificial , Adulto , Comités Consultivos , Terapia de Resincronización Cardíaca/efectos adversos , Humanos , Indicadores de Calidad de la Atención de Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...