Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 12(1): 13509, 2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35931722

RESUMEN

Each year 65% of young athletes and 25% of physically active adults suffer from at least one musculoskeletal injury that prevents them from continuing with physical activity, negatively influencing their physical and mental well-being. The treatment of musculoskeletal injuries with the adhesive elastic kinesiology tape (KT) decreases the recovery time. Patients can thus recommence physical exercise earlier. Here, a novel KT based on auxetic structures is proposed to simplify the application procedure and allow personalization. This novel KT exploits the form-fitting property of auxetics as well as their ability to simultaneously expand in two perpendicular directions when stretched. The auxetic contribution is tuned by optimizing the structure design using analytical equations and experimental measurements. A reentrant honeycomb topology is selected to demonstrate the validity of the proposed approach. Prototypes of auxetic KT to treat general elbow pains and muscle tenseness in the forearm are developed.


Asunto(s)
Atletas , Traumatismos en Atletas/psicología , Traumatismos en Atletas/terapia , Cinta Atlética , Quinesiología Aplicada/métodos , Sistema Musculoesquelético/lesiones , Adulto , Atletas/psicología , Traumatismos en Atletas/fisiopatología , Ejercicio Físico/fisiología , Antebrazo/fisiopatología , Humanos , Quinesiología Aplicada/educación , Heridas y Lesiones/fisiopatología , Heridas y Lesiones/psicología , Heridas y Lesiones/terapia
2.
Sensors (Basel) ; 20(21)2020 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-33158169

RESUMEN

Based on the use of automatic photogrammetry, different researchers made evident that the level of overlap between adjacent photographs directly affects the uncertainty of the 3D dense cloud originated by the Structure from Motion/Image Matching (SfM/IM) process. The purpose of this study was to investigate if, in the case of a convergent shooting typical of close-range photogrammetry, an optimal lateral displacement of the camera for minimizing the 3D data uncertainty could be identified. We examined five different test objects made of rock, differing in terms of stone type and visual appearance. First, an accurate reference data set was generated by acquiring each object with an active range device, based on pattern projection (σz = 18 µm). Then, each object was 3D-captured with photogrammetry, using a set of images taken radially, with the camera pointing to the center of the specimen. The camera-object minimum distance was kept at 200 mm during the shooting, and the angular displacement was as small as π/60. We generated several dense clouds by sampling the original redundant sequence at angular displacements (nπ/60, n = 1, 2, … 8). Each 3D cloud was then compared with the reference, implementing an accurate scaling protocol to minimize systematic errors. The residual standard deviation of error made consistently evident a range of angular displacements among images that appear to be optimal for reducing the measurement uncertainty, independent of each specimen shape, material, and texture. Such a result provides guidance about how best to arrange the cameras' geometry for 3D digitization of a stone cultural heritage artifact with several convergent shots. The photogrammetric tool used in the experiments was Agisoft Metashape.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA