Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39303733

RESUMEN

BACKGROUND: The resect-and-discard strategy allows endoscopists to replace post-polypectomy pathology with real-time prediction of polyp histology during colonoscopy (optical diagnosis). We aimed to investigate the benefits and harms of implementing computer-aided diagnosis (CADx) for polyp pathology into the resect-and-discard strategy. METHODS: In this systematic review and meta-analysis, we searched MEDLINE, Embase, and Scopus from database inception to June 5, 2024, without language restrictions, for diagnostic accuracy studies that assessed the performance of real-time CADx systems, compared with histology, for the optical diagnosis of diminutive polyps (≤5 mm) in the entire colon. We synthesised data for three strategies: CADx-alone, CADx-unassisted, and CADx-assisted; when the endoscopist was involved in the optical diagnosis, we synthesised data exclusively from diagnoses for which confidence in the prediction was reported as high. The primary outcomes were the proportion of polyps that would have avoided pathological assessment (ie, the proportion optically diagnosed with high confidence; main benefit) and the proportion of polyps incorrectly predicted due to false positives and false negatives (main harm), directly compared between CADx-assisted and CADx-unassisted strategies. We used DerSimonian and Laird's random-effects model to calculate all outcomes. We used Higgins I2 to assess heterogeneity, the Grading of Recommendations, Assessment, Development, and Evaluation approach to rate certainty, and funnel plots and Egger's test to examine publication bias. This study is registered with PROSPERO, CRD42024508440. FINDINGS: We found 1019 studies, of which 11 (7400 diminutive polyps, 3769 patients, and 185 endoscopists) were included in the final meta-analysis. Three studies (1817 patients and 4086 polyps [2148 neoplastic and 1938 non-neoplastic]) provided data to directly compare the primary outcome measures between the CADx-unassisted and CADx-assisted strategies. We found no significant difference between the CADx-assisted and CADx-unassisted strategies for the proportion of polyps that would have avoided pathological assessment (90% [88-93], 3653 [89·4%] of 4086 polyps diagnosed with high confidence vs 90% [95% CI 85-94], 3588 [87·8%] of 4086 polyps diagnosed with high confidence; risk ratio 1·01 [95% CI 0·99-1·04; I2=53·49%; low-certainty evidence; Egger's test p=0·18). The proportion of incorrectly predicted polyps was lower with the CADx-assisted strategy than with the CADx-unassisted strategy (12% [95% CI 7-17], 523 [14·3%] of 3653 polyps incorrectly predicted with a CADx-assisted strategy vs 13% [6-20], 582 [16·2%] of 3588 polyps incorrectly diagnosed with a CADx-unassisted strategy; risk ratio 0·88 [95% CI 0·79-0·98]; I2=0·00%; low-certainty evidence; Egger's test p=0·18). INTERPRETATION: CADx did not produce benefit nor harm for the resect-and-discard strategy, questioning its value in clinical practice. Improving the accuracy and explainability of CADx is desired. FUNDING: European Commission (Horizon Europe), the Japan Society of Promotion of Science, and Associazione Italiana per la Ricerca sul Cancro.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39209199

RESUMEN

BACKGROUND & AIMS: Computer-Aided Diagnosis (CADx) assists endoscopists in differentiating between neoplastic and non-neoplastic polyps during colonoscopy. This study aimed to evaluate the impact of polyp location (proximal vs. distal colon) on the diagnostic performance of CADx for ≤5mm polyps. METHODS: We searched for studies evaluating the performance of real-time CADx alone (i.e., independently of endoscopist judgement) for predicting the histology of colorectal polyps ≤5mm. The primary endpoints were CADx sensitivity and specificity in the proximal and distal colon. Secondary outcomes were the negative predictive value (NPV), positive predictive value (PPV), and the accuracy of the CADx alone. Distal colon was limited to the rectum and sigmoid. RESULTS: We included 11 studies for analysis with a total of 7,782 <5mm polyps. CADx specificity was significantly lower in the proximal colon compared to the distal colon (62% versus 85%; Risk ratio (RR): 0.74 [95% CI: 0.72-0.84]). Conversely, sensitivity was similar (89% vs 87% (EC-1); RR: 1.00 [95% CI: 0.97-1.03]. The NPV (64% versus 93%; RR: 0.71 [95% CI: 0.64-0.79]) and accuracy (81% vs 86%; RR: 0.95 [95% CI: 0.91-0.99]) were significantly lower in the proximal than distal colon, while PPV was higher in the proximal colon (87% vs 76%; RR: 1.11 [95% CI: 1.06-1.17]). CONCLUSION: The diagnostic performance of CADx for polyps in the proximal colon is inadequate, exhibiting significantly lower specificity compared to its performance for distal polyps. While current CADx systems are suitable for use in the distal colon, they should not be employed for proximal polyps until more performant systems are developed specifically for these lesions.

3.
Ann Surg ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39077765

RESUMEN

OBJECTIVE: To develop and externally validate an updated artificial intelligence (AI) prediction system for stratifying the risk of lymph node metastasis (LNM) in T2 colorectal cancer (CRC). SUMMARY BACKGROUND DATA: Recent technical advances allow complete local excision of T2 CRC, traditionally treated with surgical resection. Yet, the widespread adoption of this approach is hampered by the inability to stratify the risk of LNM. METHODS: Data from pT2 CRC patients undergoing surgical resection between April 2000 and May 2022 at one Japanese and one Italian center were analyzed. Primary goal was AI system development for accurate LNM prediction. Predictors encompassed seven variables: age, sex, tumor size and location, lympho-vascular invasion, histological differentiation, and carcinoembryonic antigen level. The tool's discriminating power was assessed via Area Under the Curve (AUC), sensitivity, and specificity. RESULTS: Out of 735 initial patients, 692 were eligible. Training and validation cohorts comprised of 492 and 200 patients, respectively. The AI model displayed an AUC of 0.75 in the combined validation dataset. Sensitivity for LNM prediction was 97.8% and specificity was 15.6%. The Positive and the Negative Predictive Value were 25.7% and 96% respectively. The False Negative (FN) rate was 2.2%, the False Positive was 84.4%. CONCLUSIONS: Our AI model, based on easily accessible clinical and pathological variables, moderately predicts LNM in T2 CRC. However, the risk of FN needs to be considered. The training of the model including more patients across Western and Eastern centers -differentiating between colon and rectal cancers- may improve its performance and accuracy.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39059545

RESUMEN

BACKGROUND: In the management of ulcerative colitis (UC), histological remission is increasingly recognized as the ultimate goal. The absence of neutrophil infiltration is crucial for assessing remission. This study aimed to develop an artificial intelligence (AI) system capable of accurately quantifying and localizing neutrophils in UC biopsy specimens to facilitate histological assessment. METHODS: Our AI system, which incorporates semantic segmentation and object detection models, was developed to identify neutrophils in hematoxylin and eosin-stained whole slide images. The system assessed the presence and location of neutrophils within either the epithelium or lamina propria and predicted components of the Nancy Histological Index and the PICaSSO Histologic Remission Index. We evaluated the system's performance against that of experienced pathologists and validated its ability to predict future clinical relapse risk in patients with clinically remitted UC. The primary outcome measure was the clinical relapse rate, defined as a partial Mayo score of ≥3. RESULTS: The model accurately identified neutrophils, achieving a performance of 0.77, 0.81, and 0.79 for precision, recall, and F-score, respectively. The system's histological score predictions showed a positive correlation with the pathologists' diagnoses (Spearman's ρ = 0.68-0.80; P < .05). Among patients who relapsed, the mean number of neutrophils in the rectum was higher than in those who did not relapse. Furthermore, the study highlighted that higher AI-based PICaSSO Histologic Remission Index and Nancy Histological Index scores were associated with hazard ratios increasing from 3.2 to 5.0 for evaluating the risk of UC relapse. CONCLUSIONS: The AI system's precise localization and quantification of neutrophils proved valuable for histological assessment and clinical prognosis stratification.

5.
Gut Liver ; 18(5): 803-806, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39049721

RESUMEN

Submucosal invasive (T1) colorectal cancer is a significant clinical management challenge, with an estimated 10% of patients developing extraintestinal lymph node metastasis. This condition necessitates surgical resection along with lymph node dissection to achieve a curative outcome. Thus, the precise preoperative assessment of lymph node metastasis risk is crucial to guide treatment decisions after endoscopic resection. Contemporary clinical guidelines strive to identify a low-risk cohort for whom endoscopic resection will suffice, applying stringent criteria to maximize patient safety. Those failing to meet these criteria are often recommended for surgical resection, with its associated mortality risks although it may still include patients with a low risk of metastasis. In the quest to enhance the precision of preoperative lymph node metastasis risk prediction, innovative models leveraging artificial intelligence or nomograms are being developed. Nevertheless, the debate over the ideal sensitivity and specificity for such models persists, with no consensus on target metrics. This review puts forth postoperative mortality rates as a practical benchmark for the sensitivity of predictive models. We underscore the importance of this method and advocate for research to amass data on surgical mortality in T1 colorectal cancer. Establishing specific benchmarks for predictive accuracy in lymph node metastasis risk assessment will hopefully optimize the treatment of T1 colorectal cancer.


Asunto(s)
Neoplasias Colorrectales , Metástasis Linfática , Humanos , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/mortalidad , Medición de Riesgo/métodos , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Escisión del Ganglio Linfático/métodos , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Nomogramas , Periodo Preoperatorio
6.
J Crohns Colitis ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38828734

RESUMEN

BACKGROUNDS AND AIMS: The Mayo endoscopic subscore (MES) is the most popular endoscopic disease activity measure of ulcerative colitis (UC). Artificial intelligence (AI)-assisted colonoscopy is expected to reduce diagnostic variability among endoscopists. However, no study has been conducted to ascertain whether AI-based MES assignments can help predict clinical relapse, nor has AI been verified to improve the diagnostic performance of non-specialists. METHODS: This open-label, prospective cohort study enrolled 110 patients with UC in clinical remission. The AI algorithm was developed using 74713 images from 898 patients who underwent colonoscopy at three centers. Patients were followed up after colonoscopy for 12 months, and clinical relapse was defined as a partial Mayo score >2. A multi-video, multi-reader analysis involving 124 videos was conducted to determine whether the AI system reduced the diagnostic variability among six non-specialists. RESULTS: The clinical relapse rate for patients with AI-based MES = 1 (24.5% [12/49]) was significantly higher (log-rank test, P = 0.01) than that for patients with AI-based MES = 0 (3.2% [1/31]). Relapse occurred during the 12-month follow-up period in 16.2% (13/80) of patients with AI-based MES = 0 or 1 and 50.0% (10/20) of those with AI-based MES = 2 or 3 (log-rank test, P = 0.03). Using AI resulted in better inter- and intra-observer reproducibility than endoscopists alone. CONCLUSIONS: Colonoscopy using the AI-based MES system can stratify the risk of clinical relapse in patients with UC and improve the diagnostic performance of non-specialists.

7.
Ann Intern Med ; 177(7): 919-928, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38768453

RESUMEN

BACKGROUND: Computer-aided diagnosis (CADx) allows prediction of polyp histology during colonoscopy, which may reduce unnecessary removal of nonneoplastic polyps. However, the potential benefits and harms of CADx are still unclear. PURPOSE: To quantify the benefit and harm of using CADx in colonoscopy for the optical diagnosis of small (≤5-mm) rectosigmoid polyps. DATA SOURCES: Medline, Embase, and Scopus were searched for articles published before 22 December 2023. STUDY SELECTION: Histologically verified diagnostic accuracy studies that evaluated the real-time performance of physicians in predicting neoplastic change of small rectosigmoid polyps without or with CADx assistance during colonoscopy. DATA EXTRACTION: The clinical benefit and harm were estimated on the basis of accuracy values of the endoscopist before and after CADx assistance. The certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. The outcome measure for benefit was the proportion of polyps predicted to be nonneoplastic that would avoid removal with the use of CADx. The outcome measure for harm was the proportion of neoplastic polyps that would be not resected and left in situ due to an incorrect diagnosis with the use of CADx. Histology served as the reference standard for both outcomes. DATA SYNTHESIS: Ten studies, including 3620 patients with 4103 small rectosigmoid polyps, were analyzed. The studies that assessed the performance of CADx alone (9 studies; 3237 polyps) showed a sensitivity of 87.3% (95% CI, 79.2% to 92.5%) and specificity of 88.9% (CI, 81.7% to 93.5%) in predicting neoplastic change. In the studies that compared histology prediction performance before versus after CADx assistance (4 studies; 2503 polyps), there was no difference in the proportion of polyps predicted to be nonneoplastic that would avoid removal (55.4% vs. 58.4%; risk ratio [RR], 1.06 [CI, 0.96 to 1.17]; moderate-certainty evidence) or in the proportion of neoplastic polyps that would be erroneously left in situ (8.2% vs. 7.5%; RR, 0.95 [CI, 0.69 to 1.33]; moderate-certainty evidence). LIMITATION: The application of optical diagnosis was only simulated, potentially altering the decision-making process of the operator. CONCLUSION: Computer-aided diagnosis provided no incremental benefit or harm in the management of small rectosigmoid polyps during colonoscopy. PRIMARY FUNDING SOURCE: European Commission. (PROSPERO: CRD42023402197).


Asunto(s)
Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Humanos , Pólipos del Colon/patología , Pólipos del Colon/diagnóstico por imagen , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/diagnóstico
8.
Jpn J Clin Oncol ; 54(9): 1052-1056, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-38762330

RESUMEN

Colonoscopy is the gold standard for detecting and resecting adenomas or early stage cancers to reduce the incidence and mortality rates of colorectal cancer. In a recent observational study, texture and color enhancement imaging (TXI) was reported to improve polyp detection during colonoscopy. This randomized controlled trial involving six Japanese institutions aims to confirm the superiority of TXI over standard white-light imaging (WLI) in detecting colorectal lesions during colonoscopy. During the 1-year study period, 960 patients will be enrolled, with 480 patients in the TXI and WLI groups. The primary endpoint is the mean number of adenomas detected per procedure. The secondary endpoints include adenoma detection rate, advanced adenoma detection rate, polyp detection rate, flat polyp detection rate, depressed lesion detection rate, mean polyps detected per procedure, sessile serrated lesion (SSL) detection rate, mean SSLs detected per procedure and adverse events.


Asunto(s)
Colonoscopía , Neoplasias Colorrectales , Humanos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Colonoscopía/métodos , Estudios Prospectivos , Femenino , Masculino , Adenoma/diagnóstico por imagen , Adenoma/patología , Adenoma/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Pólipos del Colon/diagnóstico , Persona de Mediana Edad , Anciano , Aumento de la Imagen/métodos , Adulto , Color
9.
Dig Liver Dis ; 56(7): 1119-1125, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38643020

RESUMEN

This systematic review evaluated the current status of AI-assisted colonoscopy to identify histologic remission and predict the clinical outcomes of patients with ulcerative colitis. The use of artificial intelligence (AI) has increased substantially across several medical fields, including gastrointestinal endoscopy. Evidence suggests that it may be helpful to predict histologic remission and relapse, which would be beneficial because current histological diagnosis is limited by the inconvenience of obtaining biopsies and the high cost and time-intensiveness of pathological diagnosis. MEDLINE and the Cochrane Central Register of Controlled Trials were searched for studies published between January 1, 2000, and October 31, 2023. Nine studies fulfilled the selection criteria and were included; five evaluated the prediction of histologic remission, two assessed the prediction of clinical outcomes, and two evaluated both. Seven were prospective observational or cohort studies, while two were retrospective observational studies. No randomized controlled trials were identified. AI-assisted colonoscopy demonstrated sensitivity between 65 %-98 % and specificity values of 80 %-97 % for identifying histologic remission. Furthermore, it was able to predict future relapse in patients with ulcerative colitis. However, several challenges and barriers still exist to its routine clinical application, which should be overcome before the true potential of AI-assisted colonoscopy can be fully realized.


Asunto(s)
Inteligencia Artificial , Colitis Ulcerosa , Colonoscopía , Colitis Ulcerosa/patología , Colitis Ulcerosa/diagnóstico , Humanos , Colonoscopía/métodos , Inducción de Remisión , Recurrencia , Estudios Observacionales como Asunto
10.
Dig Liver Dis ; 56(7): 1144-1147, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38311532

RESUMEN

Approximately 10% of submucosal invasive (T1) colorectal cancers demonstrate extraintestinal lymph node metastasis, necessitating surgical intervention with lymph node dissection. The ability to identify T1b (submucosal invasion depth ≥ 1000 µm) as a risk factor for lymph node metastasis via pre-treatment endoscopy is crucial in guiding treatment strategies. Accurately distinguishing T1b from T1a (submucosal invasion depth < 1000 µm) or dysplasia remains a significant challenge for artificial intelligence (AI) systems, which require high and consistent diagnostic capabilities. Moreover, as endoscopic therapies like endoscopic full-thickness resection and endoscopic intermuscular dissection evolve, and the focus on reducing unnecessary surgeries intensifies, the initial management of T1 colorectal cancers via endoscopic treatment is anticipated to increase. Consequently, the development of highly accurate and reliable AI systems is essential, not only for pre-treatment depth assessment but also for post-treatment risk stratification of lymph node metastasis. While such AI diagnostic systems are still under development, significant advancements are expected in the near future to improve decision-making in T1 colorectal cancer management.


Asunto(s)
Inteligencia Artificial , Neoplasias Colorrectales , Metástasis Linfática , Humanos , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/terapia , Neoplasias Colorrectales/diagnóstico , Estadificación de Neoplasias , Invasividad Neoplásica , Colonoscopía/métodos , Escisión del Ganglio Linfático
11.
J Gastroenterol Hepatol ; 39(5): 927-934, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38273460

RESUMEN

BACKGROUND AND AIM: Computer-aided detection (CADe) systems can efficiently detect polyps during colonoscopy. However, false-positive (FP) activation is a major limitation of CADe. We aimed to compare the rate and causes of FP using CADe before and after an update designed to reduce FP. METHODS: We analyzed CADe-assisted colonoscopy videos recorded between July 2022 and October 2022. The number and causes of FPs and excessive time spent by the endoscopist on FP (ET) were compared pre- and post-update using 1:1 propensity score matching. RESULTS: During the study period, 191 colonoscopy videos (94 and 97 in the pre- and post-update groups, respectively) were recorded. Propensity score matching resulted in 146 videos (73 in each group). The mean number of FPs and median ET per colonoscopy were significantly lower in the post-update group than those in the pre-update group (4.2 ± 3.7 vs 18.1 ± 11.1; P < 0.001 and 0 vs 16 s; P < 0.001, respectively). Mucosal tags, bubbles, and folds had the strongest association with decreased FP post-update (pre-update vs post-update: 4.3 ± 3.6 vs 0.4 ± 0.8, 0.32 ± 0.70 vs 0.04 ± 0.20, and 8.6 ± 6.7 vs 1.6 ± 1.7, respectively). There was no significant decrease in the true positive rate (post-update vs pre-update: 95.0% vs 99.2%; P = 0.09) or the adenoma detection rate (post-update vs pre-update: 52.1% vs 49.3%; P = 0.87). CONCLUSIONS: The updated CADe can reduce FP without impairing polyp detection. A reduction in FP may help relieve the burden on endoscopists.


Asunto(s)
Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Humanos , Colonoscopía/métodos , Diagnóstico por Computador/métodos , Reacciones Falso Positivas , Masculino , Femenino , Persona de Mediana Edad , Pólipos del Colon/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Anciano , Grabación en Video , Puntaje de Propensión , Factores de Tiempo
12.
Gastrointest Endosc ; 100(1): 97-108, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38215859

RESUMEN

BACKGROUND AND AIMS: Image-enhanced endoscopy has attracted attention as a method for detecting inflammation and predicting outcomes in patients with ulcerative colitis (UC); however, the procedure requires specialist endoscopists. Artificial intelligence (AI)-assisted image-enhanced endoscopy may help nonexperts provide objective accurate predictions with the use of optical imaging. We aimed to develop a novel AI-based system using 8853 images from 167 patients with UC to diagnose "vascular-healing" and establish the role of AI-based vascular-healing for predicting the outcomes of patients with UC. METHODS: This open-label prospective cohort study analyzed data for 104 patients with UC in clinical remission. Endoscopists performed colonoscopy using the AI system, which identified the target mucosa as AI-based vascular-active or vascular-healing. Mayo endoscopic subscore (MES), AI outputs, and histologic assessment were recorded for 6 colorectal segments from each patient. Patients were followed up for 12 months. Clinical relapse was defined as a partial Mayo score >2 RESULTS: The clinical relapse rate was significantly higher in the AI-based vascular-active group (23.9% [16/67]) compared with the AI-based vascular-healing group (3.0% [1/33)]; P = .01). In a subanalysis predicting clinical relapse in patients with MES ≤1, the area under the receiver operating characteristic curve for the combination of complete endoscopic remission and vascular healing (0.70) was increased compared with that for complete endoscopic remission alone (0.65). CONCLUSIONS: AI-based vascular-healing diagnosis system may potentially be used to provide more confidence to physicians to accurately identify patients in remission of UC who would likely relapse rather than remain stable.


Asunto(s)
Inteligencia Artificial , Colitis Ulcerosa , Colonoscopía , Recurrencia , Humanos , Colitis Ulcerosa/diagnóstico , Colitis Ulcerosa/patología , Estudios Prospectivos , Femenino , Masculino , Colonoscopía/métodos , Adulto , Persona de Mediana Edad , Mucosa Intestinal/patología , Mucosa Intestinal/diagnóstico por imagen , Colon/patología , Colon/diagnóstico por imagen , Colon/irrigación sanguínea , Estudios de Cohortes , Curva ROC , Adulto Joven , Cicatrización de Heridas , Anciano
13.
Dig Endosc ; 36(3): 341-350, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37937532

RESUMEN

OBJECTIVES: Computer-aided characterization (CADx) may be used to implement optical biopsy strategies into colonoscopy practice; however, its impact on endoscopic diagnosis remains unknown. We aimed to evaluate the additional diagnostic value of CADx when used by endoscopists for assessing colorectal polyps. METHODS: This was a single-center, multicase, multireader, image-reading study using randomly extracted images of pathologically confirmed polyps resected between July 2021 and January 2022. Approved CADx that could predict two-tier classification (neoplastic or nonneoplastic) by analyzing narrow-band images of the polyps was used to obtain a CADx diagnosis. Participating endoscopists determined if the polyps were neoplastic or not and noted their confidence level using a computer-based, image-reading test. The test was conducted twice with a 4-week interval: the first test was conducted without CADx prediction and the second test with CADx prediction. Diagnostic performances for neoplasms were calculated using the pathological diagnosis as reference and performances with and without CADx prediction were compared. RESULTS: Five hundred polyps were randomly extracted from 385 patients and diagnosed by 14 endoscopists (including seven experts). The sensitivity for neoplasia was significantly improved by referring to CADx (89.4% vs. 95.6%). CADx also had incremental effects on the negative predictive value (69.3% vs. 84.3%), overall accuracy (87.2% vs. 91.8%), and high-confidence diagnosis rate (77.4% vs. 85.8%). However, there was no significant difference in specificity (80.1% vs. 78.9%). CONCLUSIONS: Computer-aided characterization has added diagnostic value for differentiating colorectal neoplasms and may improve the high-confidence diagnosis rate.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico , Pólipos del Colon/patología , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Valor Predictivo de las Pruebas , Computadores , Imagen de Banda Estrecha/métodos
14.
DEN Open ; 4(1): e324, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38155928

RESUMEN

Objectives: Japanese guidelines include high-grade (poorly differentiated) tumors as a risk factor for lymph node metastasis (LNM) in T1 colorectal cancer (CRC). However, whether the grading is based on the least or most predominant component when the lesion consists of two or more levels of differentiation varies among institutions. This study aimed to investigate which method is optimal for assessing the risk of LNM in T1 CRC. Methods: We retrospectively evaluated 971 consecutive patients with T1 CRC who underwent initial or additional surgical resection from 2001 to 2021 at our institution. Tumor grading was divided into low-grade (well- to moderately differentiated) and high-grade based on the least or predominant differentiation analyses. We investigated the correlations between LNM and these two grading analyses. Results: LNM was present in 9.8% of patients. High-grade tumors, as determined by least differentiation analysis, accounted for 17.0%, compared to 0.8% identified by predominant differentiation analysis. A significant association with LNM was noted for the least differentiation method (p < 0.05), while no such association was found for predominant differentiation (p = 0.18). In multivariate logistic regression, grading based on least differentiation was an independent predictor of LNM (p = 0.04, odds ratio 1.68, 95% confidence interval 1.00-2.83). Sensitivity and specificity for detecting LNM were 27.4% and 84.1% for least differentiation, and 2.1% and 99.3% for predominant differentiation, respectively. Conclusions: Tumor grading via least differentiation analysis proved to be a more reliable measure for assessing LNM risk in T1 CRC compared to grading by predominant differentiation.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38056803

RESUMEN

BACKGROUND AND AIMS: Benefits of computer-aided detection (CADe) in detecting colorectal neoplasia were shown in many randomized trials in which endoscopists' behavior was strictly controlled. However, the effect of CADe on endoscopists' performance in less-controlled setting is unclear. This systematic review and meta-analyses were aimed at clarifying benefits and harms of using CADe in real-world colonoscopy. METHODS: We searched MEDLINE, EMBASE, Cochrane, and Google Scholar from inception to August 20, 2023. We included nonrandomized studies that compared the effectiveness between CADe-assisted and standard colonoscopy. Two investigators independently extracted study data and quality. Pairwise meta-analysis was performed utilizing risk ratio for dichotomous variables and mean difference (MD) for continuous variables with a 95% confidence interval (CI). RESULTS: Eight studies were included, comprising 9782 patients (4569 with CADe and 5213 without CADe). Regarding benefits, there was a difference in neither adenoma detection rate (44% vs 38%; risk ratio, 1.11; 95% CI, 0.97 to 1.28) nor mean adenomas per colonoscopy (0.93 vs 0.79; MD, 0.14; 95% CI, -0.04 to 0.32) between CADe-assisted and standard colonoscopy, respectively. Regarding harms, there was no difference in the mean non-neoplastic lesions per colonoscopy (8 studies included for analysis; 0.52 vs 0.47; MD, 0.14; 95% CI, -0.07 to 0.34) and withdrawal time (6 studies included for analysis; 14.3 vs 13.4 minutes; MD, 0.8 minutes; 95% CI, -0.18 to 1.90). There was a substantial heterogeneity, and all outcomes were graded with a very low certainty of evidence. CONCLUSION: CADe in colonoscopies neither improves the detection of colorectal neoplasia nor increases burden of colonoscopy in real-world, nonrandomized studies, questioning the generalizability of the results of randomized trials.

18.
Dig Endosc ; 35(7): 902-908, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36905308

RESUMEN

OBJECTIVES: Lymph node metastasis (LNM) prediction for T1 colorectal cancer (CRC) is critical for determining the need for surgery after endoscopic resection because LNM occurs in 10%. We aimed to develop a novel artificial intelligence (AI) system using whole slide images (WSIs) to predict LNM. METHODS: We conducted a retrospective single center study. To train and test the AI model, we included LNM status-confirmed T1 and T2 CRC between April 2001 and October 2021. These lesions were divided into two cohorts: training (T1 and T2) and testing (T1). WSIs were cropped into small patches and clustered by unsupervised K-means. The percentage of patches belonging to each cluster was calculated from each WSI. Each cluster's percentage, sex, and tumor location were extracted and learned using the random forest algorithm. We calculated the areas under the receiver operating characteristic curves (AUCs) to identify the LNM and the rate of over-surgery of the AI model and the guidelines. RESULTS: The training cohort contained 217 T1 and 268 T2 CRCs, while 100 T1 cases (LNM-positivity 15%) were the test cohort. The AUC of the AI system for the test cohort was 0.74 (95% confidence interval [CI] 0.58-0.86), and 0.52 (95% CI 0.50-0.55) using the guidelines criteria (P = 0.0028). This AI model could reduce the 21% of over-surgery compared to the guidelines. CONCLUSION: We developed a pathologist-independent predictive model for LNM in T1 CRC using WSI for determination of the need for surgery after endoscopic resection. TRIAL REGISTRATION: UMIN Clinical Trials Registry (UMIN000046992, https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000053590).


Asunto(s)
Inteligencia Artificial , Neoplasias Colorrectales , Humanos , Metástasis Linfática/patología , Estudios Retrospectivos , Endoscopía , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Ganglios Linfáticos/patología
19.
Int J Comput Assist Radiol Surg ; 18(5): 795-805, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36913126

RESUMEN

PURPOSE: Endoscopic submucosal dissection (ESD) is a minimally invasive treatment for early gastric cancer. However, perforations may happen and cause peritonitis during ESD. Thus, there is a potential demand for a computer-aided diagnosis system to support physicians in ESD. This paper presents a method to detect and localize perforations from colonoscopy videos to avoid perforation ignoring or enlarging by ESD physicians. METHOD: We proposed a training method for YOLOv3 by using GIoU and Gaussian affinity losses for perforation detection and localization in colonoscopic images. In this method, the object functional contains the generalized intersection over Union loss and Gaussian affinity loss. We propose a training method for the architecture of YOLOv3 with the presented loss functional to detect and localize perforations precisely. RESULTS: To qualitatively and quantitatively evaluate the presented method, we created a dataset from 49 ESD videos. The results of the presented method on our dataset revealed a state-of-the-art performance of perforation detection and localization, which achieved 0.881 accuracy, 0.869 AUC, and 0.879 mean average precision. Furthermore, the presented method is able to detect a newly appeared perforation in 0.1 s. CONCLUSIONS: The experimental results demonstrated that YOLOv3 trained by the presented loss functional were very effective in perforation detection and localization. The presented method can quickly and precisely remind physicians of perforation happening in ESD. We believe a future CAD system can be constructed for clinical applications with the proposed method.


Asunto(s)
Colonoscopía , Neoplasias Gástricas , Humanos , Colonoscopía/métodos , Neoplasias Gástricas/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
20.
Dig Endosc ; 35(4): 422-429, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749036

RESUMEN

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost-effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer-aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health-care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe-related cancer prevention; Statement 1.4: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer-aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health-care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high-quality cost-effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health-care systems.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Inteligencia Artificial , Colonoscopía , Endoscopía Gastrointestinal , Diagnóstico por Computador , Pólipos del Colon/diagnóstico , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA