Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Surg Res ; 302: 495-500, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39173526

RESUMEN

INTRODUCTION: Aneurysmal sac regression is a predictor of long-term outcomes after endovascular aneurysm repair (EVAR). This study aimed to compare a large cohort of TREO and non-TREO endografts over a mid-term follow-up and compare abdominal aortic aneurysm sac regression. The hypothesis was that TREO endografts have an increased sac regression by 24 mo. METHODS: This is a retrospective analysis of all EVARs completed at a single institution between 2015 and 2024. Clinical and imaging data were collected from an institutional database and patients' records. The analysis included all TREO and age, sex, anticoagulation use and current smoking-matched non-TREO endografts that satisfied anatomic indications for use of the TREO graft. The primary outcomes were sac regression at 12 and 24 mo, and secondary outcomes were rates of mortality, endoleak, and reintervention. RESULTS: Twenty-one TREO grafts were matched to 68 non-TREO grafts. The groups were similar in demographics, comorbidities, and preoperative anatomy. Preoperative abdominal aortic aneurysm sac size was larger in the TREO cohort. The mean reduction in sac size in mm was greater in the TREO cohort compared to the non-TREO cohort (-12.6 ± 8.95 versus -7.83 ± 7.74 mm, P = 0.039) over the study period. Cox regression analysis identified the TREO stent graft to be associated with 1-y sac regression (hazard ratio = 2.42, P = 0.019). The incidence of all-cause endoleaks, reintervention, and mortality were similar between cohorts. CONCLUSIONS: These findings suggest that the TREO endograft offers better mid-term outcomes with respect to sac regression with no differences in the incidence of endoleak, mortality, or reintervention.

2.
Blood ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38900973

RESUMEN

A common feature in patients with abdominal aortic aneurysms (AAA) is the formation of a nonocclusive intraluminal thrombus (ILT) in regions of aortic dilation. Platelets are known to maintain hemostasis and propagate thrombosis through several redundant activation mechanisms, yet the role of platelet activation in the pathogenesis of AAA associated ILT is still poorly understood. Thus, we sought to investigate how platelet activation impacts the pathogenesis of AAA. Using RNA-sequencing, we identify that the platelet-associated transcripts are significantly enriched in the ILT compared to the adjacent aneurysm wall and healthy control aortas. We found that the platelet specific receptor glycoprotein VI (GPVI) is among the top enriched genes in AAA ILT and is increased on the platelet surface of AAA patients. Examination of a specific indicator of platelet activity, soluble GPVI (sGPVI), in two independent AAA patient cohorts is highly predictive of a AAA diagnosis and associates more strongly with aneurysm growth rate when compared to D-dimer in humans. Finally, intervention with the anti-GPVI antibody (JAQ1) in mice with established aneurysms blunted the progression of AAA in two independent mouse models. In conclusion, we show that levels of sGPVI in humans can predict a diagnosis of AAA and AAA growth rate, which may be critical in the identification of high-risk patients. We also identify GPVI as a novel platelet-specific AAA therapeutic target, with minimal risk of adverse bleeding complications, where none currently exist.

3.
JVS Vasc Sci ; 5: 100198, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38846626

RESUMEN

Objective: Strain has become a viable index for evaluating abdominal aortic aneurysm stability after endovascular aneurysm repair (EVAR). In addition, literature has shown that healthy aortic tissue requires a degree of strain to maintain homeostasis. This has led to the hypothesis that too much strain reduction conferred by a high degree of graft oversizing is detrimental to the aneurysm neck in the seal zone of abdominal aortic aneurysms after EVAR. We investigated this in a laboratory experiment by examining the effects that graft oversizing has on the pressure-normalized strain ( ε ρ + ¯ /pulse pressure [PP]) reduction using four different infrarenal EVAR endografts and our ultrasound elastography technique. Approximate graft oversizing percentages were 20% (30 mm phantom-graft combinations), 30% (28 mm phantom-graft combinations), and 50% (24 mm phantom-graft combinations). Methods: Axisymmetric, 10% by mass polyvinyl alcohol phantoms were connected to a flow simulator. Ultrasound elastography was performed before and after implantation with the four different endografts: (1) 36 mm polyester/stainless steel, (2) 36 mm polyester/electropolished nitinol, (3) 35 mm polytetrafluoroethylene (PTFE)/nitinol, and (4) 36 mm nitinol/polyester/platinum-iridium. Five ultrasound cine loops were taken of each phantom-graft combination. They were analyzed over two different cardiac cycles (end-diastole to end-diastole), yielding a total of 10 maximum mean principal strain ( ε ρ + ¯ ) values. ε ρ + ¯ was divided by pulse pressure to yield pressure-normalized strain ( ε ρ + ¯ /PP). An analysis of variance was performed for graft comparisons. We calculated the average percent ε ρ + ¯ /PP reduction by manufacturer and percent oversizing. These values were used for linear regression analysis. Results: Results from one-way analysis of variance showed a significant difference in ε ρ + ¯ /PP between the empty phantom condition and all oversizing conditions for all graft manufacturers (F(3, 56) = 106.7 [graft A], 132.7 [graft B], 106.5 [graft C], 105.7 [graft D], P < .0001 for grafts A-D). There was a significant difference when comparing the 50% condition with the 30% and 20% conditions across all manufacturers by post hoc analysis (P < .0001). No significant difference was found when comparing the 20% and 30% oversizing conditions for any of the manufacturers or when comparing ε ρ + ¯ /PP values across the manufacturers according to percent oversize. Linear regression demonstrated a significant positive correlation between the percent graft oversize and the all-graft average percent ε ρ + ¯ /PP reduction ( R 2  = 0.84, P < .0001). Conclusions: This brief report suggests that a 10% increase in graft oversizing leads to an approximate 5.9% reduction in ε ρ + ¯ /PP on average. Applied clinically, this increase may result in increased stiffness in axisymmetric vessels after EVAR. Further research is needed to determine if this is clinically significant.

4.
J Surg Res ; 299: 17-25, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38688237

RESUMEN

INTRODUCTION: Physician-modified endografts (PMEGs) have been used for repair of thoracoabdominal aortic aneurysms (TAAAs) for 2 decades with good outcomes but limited financial data. This study compared the financial and clinical outcomes of PMEGs to the Cook Zenith-Fenestrated (ZFEN) graft and open surgical repair (OSR). METHODS: A retrospective review of financial and clinical data was performed for all patients who underwent endovascular or OSR of juxtarenal aortic aneurysms and TAAAs from January 2018 to December 2022 at an academic medical center. Clinical presentation, demographics, operative details, and outcomes were reviewed. Financial data was obtained through the institution's finance department. The primary end point was contribution margin (CM). RESULTS: Thirty patients met inclusion criteria, consisting of twelve PMEG, seven ZFEN, and eleven open repairs. PMEG repairs had a total CM of -$110,000 compared to $18,000 for ZFEN and $290,000 for OSR. Aortic and branch artery implants were major cost-drivers for endovascular procedures. Extent II TAAA repairs were the costliest PMEG procedure, with a total device cost of $59,000 per case. PMEG repairs had 30-d and 1-y mortality rates of 8.3% which was not significantly different from ZFEN (0.0%, P = 0.46; 0.0%, P = 0.46) or OSR (9.1%, P = 0.95; 18%, P = 0.51). Average intensive care unit and hospital stay after PMEG repairs were comparable to ZFEN and shorter than OSR. CONCLUSIONS: Our study suggests that PMEG repairs yield a negative CM. To make these cases financially viable for hospital systems, device costs will need to be reduced or reimbursement rates increased by approximately $8800.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Estudios Retrospectivos , Masculino , Femenino , Procedimientos Endovasculares/economía , Procedimientos Endovasculares/instrumentación , Anciano , Prótesis Vascular/economía , Implantación de Prótesis Vascular/economía , Implantación de Prótesis Vascular/instrumentación , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/economía , Persona de Mediana Edad , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/economía , Anciano de 80 o más Años
5.
J Vasc Surg Cases Innov Tech ; 10(3): 101471, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38591020

RESUMEN

Hepatic artery (HA) pseudoaneurysm rupture is a rare and potentially lethal pathology. We present the case of a celiac artery dissection complicated by an HA pseudoaneurysm rupture that was treated successfully with endovascular stenting. The patient's postoperative course was uncomplicated, and he was further evaluated for an underlying connective tissue disorder. There is no standard treatment for a ruptured HA pseudoaneurysm, although transarterial embolization is most frequently reported. This report demonstrates that self-expanding stent grafts are effective in the emergent repair of HA pseudoaneurysm rupture.

6.
J Surg Res ; 295: 827-836, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38168643

RESUMEN

BACKGROUND: Elective endovascular aneurysm repair (EVAR) can be performed via local anesthetics and/or regional (epidural or spinal) anesthesia (locoregional [LR]), versus general anesthesia (GA), conferring reduced intensive care unit (ICU) and hospital stays. Current analyses fail to account for temporal changes in vascular practice. Therefore, this study aimed to confirm reductions in ICU and hospital stays among LR patients while accounting for changes in practice patterns. MATERIALS AND METHODS: Using the Society for Vascular Surgery's Vascular Quality Initiative, elective EVARs from August 2003 to June 2021 were grouped into LR or GA. Outcomes included ICU admission and prolonged hospital stay (>2 d). Procedures were stratified into groups of 2 y periods, and outcomes were analyzed within each time period. Univariable and multivariate analyses were used to assess outcomes. RESULTS: LR was associated with reduced ICU admissions (22.3% versus 32.1%, P < 0.001) and prolonged hospital stays (14.3% versus 7.9%, P < 0.001) overall. When stratified by year, LR maintained its association with reduced ICU admissions in 2014-2015 (21.8% versus 34.0%, P < 0.001), 2016-2017 (23.6% versus 31.6%, P < 0.001), 2018-2019 (18.5% versus 30.2%, P < 0.001), and 2020-2021 (15.8% versus 28.8%, P < 0.001), although this was highly facility dependent. LR was associated with fewer prolonged hospital stays in 2014-2015 (15.6% versus 20.4%, P = 0.001) and 2016-2017 (13.3% versus 16.6%, P = 0.006) but not after 2017. CONCLUSIONS: GA and LR have similar rates of prolonged hospital stays after 2017, while LR anesthesia was associated with reduced rates of ICU admissions, although this is facility-dependent, providing a potential avenue for resource preservation in patients suitable for LR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Anestesia General , Tiempo de Internación , Unidades de Cuidados Intensivos , Estudios Retrospectivos , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control
7.
Ann Vasc Surg ; 97: 203-210, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37659648

RESUMEN

BACKGROUND: There are limited analyses of survival and postoperative outcomes in chronic mesenteric ischemia (CMI) using data from large cohorts. Current guidelines recommend open repair (OR) for younger, healthier patients when long-term benefits outweigh increased perioperative risks or for poor endovascular repair (ER) candidates. This study investigates whether long-term survival, reintervention, and value differ between these treatment modalities. METHODS: A retrospective cohort analysis was performed on data extracted from the Statewide Planning and Research Cooperative System, the New York statewide all-payer database containing demographics, diagnoses, treatments, and charges. Patients were selected for CMI and subsequent ER or OR using International Classification of Diseases, Ninth Revision codes. Patients with peripheral arterial disease were excluded to account for ambiguity in the International Classification of Diseases, Ninth Revision procedure code for angioplasty of noncoronary vessels, which includes angioplasty of upper and lower extremity vessels. Kaplan-Meier analysis was used to compare 1-year and 5-year survival and reintervention between treatment modalities using a propensity-matched cohort. Cox proportional hazards testing was performed to find factors associated with 1-year and 5-year survival and reintervention. Analysis of procedural value was performed using linear regression. RESULTS: From 2000 to 2014, 744 patients met inclusion criteria. Of these, 209 (28.1%) underwent OR and 535 (71.9%) ER. No difference between propensity-matched groups was found in 1-year (P = 0.46) or 5-year (P = 0.91) survival. Congestive heart failure (hazard ratio [HR]: 2.8, 95% confidence interval [CI]: 1.7-4.4; P < 0.01), cancer (HR: 2.8, 95% CI: 1.3-5.8; P < 0.01), and dysrhythmia (HR: 1.8, 95% CI: 1.1-2.8; P = 0.02) correlated with 1-year mortality. Cancer (HR: 2.9, 95% CI: 1.6-5.5; P < 0.01), congestive heart failure (HR: 2.2, 95% CI: 1.5-3.2; P < 0.01), chronic pulmonary disease (HR: 1.4, 95% CI: 1.0-2.0; P = 0.04), and age (HR: 1.03, 95% CI: 1.01-1.05; P < 0.01) correlated with 5-year mortality. Treatment modality was not associated with reintervention at 1 year on Kaplan-Meier analysis (P = 0.29). However, ER showed increased instances of reintervention at 5 years (P < 0.01). Additionally, ER was associated with an increased 5-year value (0.7 ± 0.9 vs. 0.5 ± 0.5 life years/charges at index admission [$10k], P < 0.01; b coefficient: 0.2, 95% CI: 0.1-0.4, P < 0.01). CONCLUSIONS: This is the largest retrospective propensity-matched single-study cohort to analyze long-term survival outcomes after intervention for CMI. Long-term mortality was independent of treatment modality and rather was associated with patient comorbidities. Therefore, treatment selection should depend on anatomic considerations and long-term value. ER should be considered over OR in patients with amenable anatomy based on the superior procedural value.


Asunto(s)
Procedimientos Endovasculares , Insuficiencia Cardíaca , Isquemia Mesentérica , Neoplasias , Humanos , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/cirugía , Estudios Retrospectivos , Enfermedad Crónica , Insuficiencia Cardíaca/etiología , Estimación de Kaplan-Meier , Medición de Riesgo
8.
Front Cardiovasc Med ; 10: 1232844, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37719977

RESUMEN

Introduction: Current abdominal aortic aneurysm (AAA) assessment relies on analysis of AAA diameter and growth rate. However, evidence demonstrates that AAA pathology varies among patients and morphometric analysis alone is insufficient to precisely predict individual rupture risk. Biomechanical parameters, such as pressure-normalized AAA principal wall strain (ερ+¯/PP, %/mmHg), can provide useful information for AAA assessment. Therefore, this study utilized a previously validated ultrasound elastography (USE) technique to correlate ερ+¯/PP with the current AAA assessment methods of maximal diameter and growth rate. Methods: Our USE algorithm utilizes a finite element mesh, overlaid a 2D cross-sectional view of the user-defined AAA wall, at the location of maximum diameter, to track two-dimensional, frame-to-frame displacements over a full cardiac cycle, using a custom image registration algorithm to produce ερ+¯/PP. This metric was compared between patients with healthy aortas and AAAs (≥3 cm) and compared between small and large AAAs (≥5 cm). AAAs were then separated into terciles based on ερ+¯/PP values to further assess differences in our metric across maximal diameter and prospective growth rate. Non-parametric tests of hypotheses were used to assess statistical significance as appropriate. Results: USE analysis was conducted on 129 patients, 16 healthy aortas and 113 AAAs, of which 86 were classified as small AAAs and 27 as large. Non-aneurysmal aortas showed higher ερ+¯/PP compared to AAAs (0.044 ± 0.015 vs. 0.034 ± 0.017%/mmHg, p = 0.01) indicating AAA walls to be stiffer. Small and large AAAs showed no difference in ερ+¯/PP. When divided into terciles based on ερ+¯/PP cutoffs of 0.0251 and 0.038%/mmHg, there was no difference in AAA diameter. There was a statistically significant difference in prospective growth rate between the intermediate tercile and the outer two terciles (1.46 ± 2.48 vs. 3.59 ± 3.83 vs. 1.78 ± 1.64 mm/yr, p = 0.014). Discussion: There was no correlation between AAA diameter and ερ+¯/PP, indicating biomechanical markers of AAA pathology are likely independent of diameter. AAAs in the intermediate tercile of ερ+¯/PP values were found to have nearly double the growth rates than the highest or lowest tercile, indicating an intermediate range of ερ+¯/PP values for which patients are at risk for increased AAA expansion, likely necessitating more frequent imaging follow-up.

9.
bioRxiv ; 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37461445

RESUMEN

A common feature in patients with abdominal aortic aneurysms (AAA) is the formation of a nonocclusive intraluminal thrombus (ILT) in regions of aortic dilation. Platelets are known to maintain hemostasis and propagate thrombosis through several redundant activation mechanisms, yet the role of platelet activation in the pathogenesis of AAA associated ILT is still poorly understood. Thus, we sought to investigate how platelet activation impacts the pathogenesis of AAA. Using RNA-sequencing, we identify that the platelet-associated transcripts are significantly enriched in the ILT compared to the adjacent aneurysm wall and healthy control aortas. We found that the platelet specific receptor glycoprotein VI (GPVI) is among the top enriched genes in AAA ILT and is increased on the platelet surface of AAA patients. Examination of a specific indicator of platelet activity, soluble GPVI (sGPVI), in two independent AAA patient cohorts is highly predictive of a AAA diagnosis and associates more strongly with aneurysm growth rate when compared to D-dimer in humans. Finally, intervention with the anti-GPVI antibody (J) in mice with established aneurysms blunted the progression of AAA in two independent mouse models. In conclusion, we show that levels of sGPVI in humans can predict a diagnosis of AAA and AAA growth rate, which may be critical in the identification of high-risk patients. We also identify GPVI as a novel platelet-specific AAA therapeutic target, with minimal risk of adverse bleeding complications, where none currently exist. KEY POINTS: Soluble glycoprotein VI, which is a platelet-derived blood biomarker, predicts a diagnosis of AAA, with high sensitivity and specificity in distinguishing patients with fast from slow-growing AAA.Blockade of glycoprotein VI in mice with established aneurysms reduces AAA progression and mortality, indicating therapeutic potential.

10.
J Vasc Surg Cases Innov Tech ; 9(2): 101193, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37274439

RESUMEN

An 80-year-old man presented with a subacute zone 3-5 type B aortic dissection complicated by rupture and visceral and lower extremity malperfusion. He underwent emergent zone 2 repair with a Gore TAG thoracic branch endograft with inclusion of the left subclavian artery for a dominant left vertebral artery. The patient's postoperative course was uncomplicated. Type B aortic dissections can be anatomically complex, and rupture is a rare complication in the subacute phase. We report the novel use of a Gore TAG thoracic branch endograft for the management of type B aortic dissection complicated by rupture and demonstrate its feasibility for patients with type B aortic dissection complicated by rupture.

11.
J Vasc Surg ; 78(1): 150-157, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36918106

RESUMEN

OBJECTIVE: We sought to quantify the percent calcification within carotid artery plaques and assess its impact on percent residual stenosis and rate of restenosis in patients undergoing transcarotid artery revascularization for symptomatic and asymptomatic carotid artery stenosis. METHODS: A retrospective review of prospectively collected institutional Vascular Quality Initiative data was performed to identify all patients undergoing transcarotid artery revascularization from December 2015 to June 2021 (n = 210). Patient and lesion characteristics were extracted. Using a semiautomated workflow, preoperative computed tomography head and neck angiograms were analyzed to determine the calcified plaque volume in distal common carotid artery and internal carotid artery plaques. Intraoperative digital subtraction angiograms were reviewed to calculate the percent residual stenosis post-intervention according to North American Symptomatic Carotid Endarterectomy Trial criteria. Peak systolic velocity and end-diastolic velocity were extracted from outpatient carotid duplex ultrasound examinations. Univariate logistic regression was performed to analyze the relationship of calcium volume percent and Vascular Quality Initiative lesion calcification to percent residual stenosis in completion angiograms. Kaplan-Meier analysis examined the relationship between calcium volume percent and in-stent stenosis over 36 months. RESULTS: One hundred ninety-seven carotid arteries were preliminarily examined. Predilation was performed in 87.4% of cases with a mean balloon diameter of 5.1 ± 0.7 mm and a mean stent diameter was 8.8 ± 1.1 mm. The mean calcium volume percent was 11.9 ± 12.4% and the mean percent residual stenosis was 16.1 ± 15.6%. Univariate logistic regression demonstrated a statistically significant difference between calcium volume percent and percent residual stenosis (odds ratio [OR], 1.324; 95% confidence interval [CI], 1.005-1.746; P = .046). Stratified by quartile, only the top 25% of calcified plaques (>18.7% calcification) demonstrated a statistically significant association with higher percent residual stenosis (OR, 2.532; 95% CI, 1.049-6.115; P =.039). There was no statistical significance with lesion calcification (OR, 1.298; 95% C,: 0.980-1.718; P = .069). A Kaplan-Meier analysis demonstrated a statistically significant increase in the rate of in-stent stenosis during a 36-month follow-up for lesions containing >8.2% calcium volume (P = .0069). CONCLUSIONS: A calcium volume percent of >18.7% was associated with a higher percent residual stenosis, and a calcium volume percent of >8.2% was associated with higher in-stent stenosis at 36 months. There was one clinically diagnosed stroke during the follow-up period, demonstrating the overall safety of the procedure.


Asunto(s)
Estenosis Carotídea , Endarterectomía Carotidea , Procedimientos Endovasculares , Placa Aterosclerótica , Accidente Cerebrovascular , Humanos , Constricción Patológica/complicaciones , Calcio , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/cirugía , Procedimientos Quirúrgicos Vasculares , Arterias Carótidas , Placa Aterosclerótica/complicaciones , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Factores de Riesgo , Endarterectomía Carotidea/efectos adversos
12.
J Vasc Surg Cases Innov Tech ; 9(1): 101102, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36814540

RESUMEN

Objective: Transcarotid artery revascularization (TCAR) has been used with increasing prevalence for treatment of carotid artery stenosis. TCAR holds potential benefits over traditional carotid endarterectomy (CEA) or transfemoral carotid artery stenting by its nature of being less invasive than CEA but more neuroprotective than transfemoral carotid artery stenting. The purpose of this pilot study is to evaluate the effectiveness of the neuroprotection system of TCAR with flow reversal by quantifying the incidence and degree of new intracerebral lesions using diffusion-weighted magnetic resonance imaging (DW-MRI). This study is the first to evaluate these findings in a real-world, high-risk cohort, who would have been excluded from the ROADSTER and ENROUTE transcarotid neuroprotection system DW-MRI studies. Methods: Patients undergoing unilateral TCAR for symptomatic or asymptomatic severe internal carotid artery disease were eligible and prospectively enrolled in the study. All patients had high risk features, including comorbidities or medications, which excluded them from industry-sponsored DW-MRI trials. Patients underwent a preoperative DW-MRI to obtain a baseline intracerebral evaluation within 1 week of the scheduled surgery. The follow-up DW-MRI occurred within 48 hours postoperatively. The primary outcome was new, acute postoperative lesion(s) identified on DW-MRI. Secondary outcomes include any major stroke, myocardial infarction, or death during hospitalization. Results: Five consecutive patients underwent TCAR with preoperative and postoperative imaging. All five patients were on dual antiplatelet therapy before their procedure and verified to be therapeutic on these agents. All patients underwent a right-sided TCAR and three were symptomatic as the indication for their procedure. All five patients demonstrated chronic lesions on the preoperative DW-MRI. Technical success was achieved in all five patients, with one operative complication involving a dissection of the common carotid at the access site, which was stented using the TCAR system. Postoperative DW-MRI did not identify any new intracerebral lesions in any patient following the procedure. No patient had a stroke, myocardial infarction, or death during hospitalization. Conclusions: In this real-world, high-risk cohort, TCAR was completed with no evidence of new, postoperative DW-MRI lesions. These data further demonstrate that TCAR with flow reversal is an effective neuroprotective strategy for carotid revascularization. Further study is warranted to evaluate DW-MRI differences between TCAR and CEA.

13.
J Vasc Surg ; 77(4): 1061-1069, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36400363

RESUMEN

OBJECTIVE: It has been shown local or regional anesthetic techniques are a feasible alternative to general anesthesia for endovascular aortic aneurysm repair (EVAR). However, studies to date have shown controversial findings with respect to the benefit of locoregional anesthesia (LR) in the elective setting. The objective of this study is to compare postoperative outcomes between LR and general anesthesia (GA) in the setting of elective EVAR, using a large, multicenter database. METHODS: Using the Society for Vascular Surgery Vascular Quality Initiative database, we retrospectively analyzed all patients who underwent elective EVAR from August 2003 to June 2021. Patients were grouped by anesthetic type based on the level of consciousness afforded by the anesthetic: local or regional anesthesia (LR) vs GA. Primary outcomes were total postoperative hospital length-of-stay (LOS) and intensive care unit (ICU) LOS. Propensity score matching was used for risk adjustment and to analyze the primary outcomes with confirmatory analysis using logistic or linear regression, as appropriate, in single and multilevel models. Secondary outcomes were 30-day mortality, 1-year mortality, postoperative outcomes, operative time, fluoroscopy time, and reoperation rate. These were analyzed following propensity score matching as well as using logistic regression and Cox proportional hazard regression in single and multilevel models, as appropriate. RESULTS: A total of 50,809 patients underwent elective EVAR from 2003 to 2021. Of these, 4302 repairs used LR (8.5%) and 46,507 (91.5%) were performed under GA. After employing propensity score matching, two groups of 3027 patients were produced. These showed no significant difference in 30-day mortality (odds ratio, 1.22; P = .53), 1-year mortality (hazard ratio, 1.06; P = .62), or any postoperative outcomes. LR was found to be significantly associated with shorter hospital stays (≤2 days) (12.5% vs 14.8%; P = .01), decreased ICU utilization (19.3% vs 30.6%; P < .001), decreased operative time (110.8 vs 117.3 minutes; P < .001), decreased fluoroscopy time (21.0 vs 22.7 minutes; P < .001), and a slight reduction in reoperation rate (1.2% vs 1.9%; P = .02), which all remained significant following single-level and multilevel multivariate analyses accounting for hospital and physician random effects. CONCLUSIONS: These data suggest that LR anesthesia is safe and may offer advantages in reducing resource utilization for patients undergoing elective EVAR, primarily based on associations with reduced ICU care and reduced hospital stay. Given these findings, LR may prove an advantageous technique in appropriately selected patient populations.


Asunto(s)
Anestesia de Conducción , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Tiempo de Internación , Reparación Endovascular de Aneurismas , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Anestesia de Conducción/efectos adversos , Unidades de Cuidados Intensivos , Complicaciones Posoperatorias
14.
J Vasc Surg Cases Innov Tech ; 8(4): 762-769, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36438670

RESUMEN

Objective: Predicting success after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) relies on measurements of aneurysm sac regression. However, in the absence of regression, morphometric analysis alone is insufficient to reliably predict the successful remodeling of AAAs after EVAR. Biomechanical parameters, such as pressure-normalized principal strain, might provide useful information in the post-EVAR AAA assessment. Our objective was to assess the feasibility of our novel ultrasound elastography (USE) technique to detect changes in the aortic wall principal strain in patients who had undergone EVAR and determine the temporal nature of the biomechanical changes in the aorta. Methods: USE images were obtained from patients undergoing elective EVAR intraoperatively, immediately before and after endograft implantation, and at their 30-day follow-up. The maximal mean principal strain ( ε ρ + ¯ ) for each scan was assessed using our novel technique, which uses a finite element mesh to track the frame-to-frame displacements of the aortic wall over one cardiac cycle. The ε ρ + ¯ in the user-defined aortic wall was then divided by the pulse pressure at the time of the scan to produce a pressure-normalized strain measurement ( ε ρ + ¯ /PP), a surrogate for tissue stiffness. Paired t tests were used to compare the pre- and postoperative ε ρ + ¯ /PP and the postoperative and 30-day ε ρ + ¯ /PP. Patient 30-day sac regression and endoleak data were collected by a review of 30-day follow-up computed tomography scans. Results: USE analysis of the data from 12 patients demonstrated a significant reduction in aortic wall ε ρ + ¯ /PP (average, 0.191% ± 0.09%/kPa vs 0.087% ± 0.04%/kPa; P = .002) immediately after graft implantation, with a nonsignificant change in the ε ρ + ¯ /PP (0.091% ± 0.04%/kPa vs 0.102% ± 0.05%/kPa; P = .47) from postoperatively to 30-day follow-up. This represents an average 46.5% reduction after stent placement, with a nonsignificant 18.1% increase at 30-day follow-up. All the patients showed sac stability, except for two patients who had demonstrated 7.3-mm and 6.8-mm sac regressions. Conclusions: Our analysis has demonstrated that the presented USE technique is a feasible method for detecting significant reductions in aortic ε ρ + ¯ /PP intraoperatively after EVAR. We found that patients undergoing EVAR will experience large reductions in the ε ρ + ¯ /PP intraoperatively after graft implantation, with stabilization found at their 30-day follow-up. These preliminary data have shown that an intraoperative ε ρ + ¯ /PP reduction could be a promising correlate of post-EVAR aneurysm remodeling. Our results have also suggested that endograft design likely plays a large role in determining the aneurysm biomechanical changes immediately after implantation.

15.
J Vasc Surg Cases Innov Tech ; 6(4): 505-508, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33134631

RESUMEN

The rate of heart failure and subsequent placement of left ventricular assistive devices (LVADs) has been increasing. The extra-anatomic placement of the LVAD and outflow graft presents a challenging problem for repair when complications arise. The present report describes a case of a 63-year-old man who had presented with acute pseudoaneurysm of the outflow graft of his recently placed LVAD. Percutaneous access of the left subclavian artery and percutaneous, transthoracic access of the outflow graft was obtained to allow for sheath placement and stent deployment within the outflow graft. The patient underwent successful endovascular repair of the defect without complications.

16.
Proc Natl Acad Sci U S A ; 116(26): 13006-13015, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31189595

RESUMEN

Abdominal aortic aneurysm (AAA) remains the second most frequent vascular disease with high mortality but has no approved medical therapy. We investigated the direct role of apelin (APLN) in AAA and identified a unique approach to enhance APLN action as a therapeutic intervention for this disease. Loss of APLN potentiated angiotensin II (Ang II)-induced AAA formation, aortic rupture, and reduced survival. Formation of AAA was driven by increased smooth muscle cell (SMC) apoptosis and oxidative stress in Apln-/y aorta and in APLN-deficient cultured murine and human aortic SMCs. Ang II-induced myogenic response and hypertension were greater in Apln-/y mice, however, an equivalent hypertension induced by phenylephrine, an α-adrenergic agonist, did not cause AAA or rupture in Apln-/y mice. We further identified Ang converting enzyme 2 (ACE2), the major negative regulator of the renin-Ang system (RAS), as an important target of APLN action in the vasculature. Using a combination of genetic, pharmacological, and modeling approaches, we identified neutral endopeptidase (NEP) that is up-regulated in human AAA tissue as a major enzyme that metabolizes and inactivates APLN-17 peptide. We designed and synthesized a potent APLN-17 analog, APLN-NMeLeu9-A2, that is resistant to NEP cleavage. This stable APLN analog ameliorated Ang II-mediated adverse aortic remodeling and AAA formation in an established model of AAA, high-fat diet (HFD) in Ldlr-/- mice. Our findings define a critical role of APLN in AAA formation through induction of ACE2 and protection of vascular SMCs, whereas stable APLN analogs provide an effective therapy for vascular diseases.


Asunto(s)
Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/patología , Apelina/metabolismo , Neprilisina/metabolismo , Anciano , Anciano de 80 o más Años , Angiotensina II/administración & dosificación , Enzima Convertidora de Angiotensina 2 , Animales , Aorta Abdominal/citología , Aneurisma de la Aorta Abdominal/tratamiento farmacológico , Aneurisma de la Aorta Abdominal/etiología , Apelina/genética , Apoptosis/efectos de los fármacos , Apoptosis/genética , Fármacos Cardiovasculares/química , Fármacos Cardiovasculares/farmacología , Fármacos Cardiovasculares/uso terapéutico , Dieta Alta en Grasa/efectos adversos , Modelos Animales de Enfermedad , Femenino , Técnicas de Silenciamiento del Gen , Humanos , Masculino , Ratones Transgénicos , Persona de Mediana Edad , Miocitos del Músculo Liso , Neprilisina/genética , Estrés Oxidativo/efectos de los fármacos , Estrés Oxidativo/genética , Peptidil-Dipeptidasa A/metabolismo , Fenilefrina/administración & dosificación , Cultivo Primario de Células , Proteolisis/efectos de los fármacos , ARN Interferente Pequeño/metabolismo , Receptores de LDL/genética , Receptores de LDL/metabolismo , Remodelación Vascular/efectos de los fármacos , Remodelación Vascular/genética
17.
J Vis Exp ; (139)2018 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-30295670

RESUMEN

Ultrasound (US) elastography, or elasticity imaging, is an adjunct imaging technique that utilizes sequential US images of soft tissues to measure the tissue motion and infer or quantify the underlying biomechanical characteristics. For abdominal aortic aneurysms (AAA), biomechanical properties such as changes in the tissue's elastic modulus and estimates of the tissue stress may be essential for assessing the need for the surgical intervention. Abdominal aortic aneurysms US elastography could be a useful tool to monitor AAA progression and identify changes in biomechanical properties characteristic of high-risk patients. A preliminary goal in the development of an AAA US elastography technique is the validation of the method using a physically relevant model with known material properties. Here we present a process for the production of AAA tissue-mimicking phantoms with physically relevant geometries and spatially modulated material properties. These tissue phantoms aim to mimic the US properties, material modulus, and geometry of the abdominal aortic aneurysms. Tissue phantoms are made using a polyvinyl alcohol cryogel (PVA-c) and molded using 3D printed parts created using computer aided design (CAD) software. The modulus of the phantoms is controlled by altering the concentration of PVA-c and by changing the number of freeze-thaw cycles used to polymerize the cryogel. The AAA phantoms are connected to a hemodynamic pump, designed to deform the phantoms with the physiologic cyclic pressure and flows. Ultra sound image sequences of the deforming phantoms allowed for the spatial calculation of the pressure normalized strain and the identification of mechanical properties of the vessel wall. Representative results of the pressure normalized strain are presented.


Asunto(s)
Aorta Abdominal , Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Materiales Biomiméticos , Humanos
18.
Arterioscler Thromb Vasc Biol ; 38(7): 1594-1606, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29724818

RESUMEN

OBJECTIVE: Reduced blood flow and tissue oxygen tension conditions result from thrombotic and vascular diseases such as myocardial infarction, stroke, and peripheral vascular disease. It is largely assumed that while platelet activation is increased by an acute vascular event, chronic vascular inflammation, and ischemia, the platelet activation pathways and responses are not themselves changed by the disease process. We, therefore, sought to determine whether the platelet phenotype is altered by hypoxic and ischemic conditions. APPROACH AND RESULTS: In a cohort of patients with metabolic and peripheral artery disease, platelet activity was enhanced, and inhibition with oral antiplatelet agents was impaired compared with platelets from control subjects, suggesting a difference in platelet phenotype caused by the disease. Isolated murine and human platelets exposed to reduced oxygen (hypoxia chamber, 5% O2) had increased expression of some proteins that augment platelet activation compared with platelets in normoxic conditions (21% O2). Using a murine model of critical limb ischemia, platelet activity was increased even 2 weeks postsurgery compared with sham surgery mice. This effect was partly inhibited in platelet-specific ERK5 (extracellular regulated protein kinase 5) knockout mice. CONCLUSIONS: These findings suggest that ischemic disease changes the platelet phenotype and alters platelet agonist responses because of changes in the expression of signal transduction pathway proteins. Platelet phenotype and function should, therefore, be better characterized in ischemic and hypoxic diseases to understand the benefits and limitations of antiplatelet therapy.


Asunto(s)
Plaquetas/metabolismo , Hipoxia/sangre , Isquemia/sangre , Oxígeno/sangre , Enfermedad Arterial Periférica/sangre , Activación Plaquetaria , Animales , Plaquetas/efectos de los fármacos , Estudios de Casos y Controles , Enfermedad Crítica , Modelos Animales de Enfermedad , Humanos , Hipoxia/fisiopatología , Isquemia/tratamiento farmacológico , Isquemia/fisiopatología , Masculino , Ratones Endogámicos C57BL , Ratones Noqueados , Proteína Quinasa 7 Activada por Mitógenos/sangre , Proteína Quinasa 7 Activada por Mitógenos/genética , Enfermedad Arterial Periférica/tratamiento farmacológico , Enfermedad Arterial Periférica/fisiopatología , Fenotipo , Activación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Neumonectomía , Transducción de Señal
19.
Artículo en Inglés | MEDLINE | ID: mdl-31213733

RESUMEN

The overall geometry and different biomechanical parameters of an abdominal aortic aneurysm (AAA), contribute to its severity and risk of rupture, therefore they could be used to track its progression. Previous and ongoing research efforts have resorted to using uniform material properties to model the behavior of AAA. However, it has been recently illustrated that different regions of the AAA wall exhibit different behavior due to the effect of the biological activities in the metalloproteinase matrix that makes up the wall at the aneurysm site. In this work, we introduce a non-invasive patient-specific regional material property model to help us better understand and investigate the AAA wall stress distribution, peak wall stress (PWS) severity, and potential rupture risk. Our results indicate that the PWS and the overall wall stress distribution predicted using the proposed regional material property model, are higher than those predicted using the traditional homogeneous, hyper-elastic model (p <1.43E-07). Our results also show that to investigate AAA, the overall geometry, presence of intra-luminal thrombus (ILT), and loading condition in a patient specific manner may be critical for capturing the biomechanical complexity of AAAs.

20.
Artículo en Inglés | MEDLINE | ID: mdl-31342015

RESUMEN

Abdominal aortic aneurysms, which consist of dilatations of the infra-renal aorta by at least 1.5 times of its normal diameter, are becoming a leading cause of death worldwide. Rupture often occurs unexpectedly, before a repair procedure is conducted. The AAA maximum diameter has been used as a clinical criterion to monitor AAA severity. However, assessment of AAA rupture risk requires knowledge of wall stress and wall strength at the potential rupture location. We conducted a study on 37 patient specific CT datasets to investigate the benefits of using peak wall stress instead of Dmax for AAA rupture severity. Correlation between PWS and 24 geometric indices and biomechanical factors was studied where eleven of them showed a statistically significant correlation with PWS. A Finite Element Analysis Rupture Index was used to conclude that the use of D max as a single predictor of AAA behavior and severity may be insufficient based on our patient population with a Dmax smaller than the 5.5 cm, clinically recommended repair threshold.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA