Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Curr Probl Cardiol ; 47(12): 101392, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36100093

RESUMEN

Mycobacterium chimaera is an opportunistic and emerging pathogen, which has been recognized to cause prosthetic valve infective endocarditis and disseminated infection following open-chest cardiac surgery with certain contaminated heater-cooler systems. Diagnostic evaluation of suspected prosthetic valve infective endocarditis due to M chimaera is challenging and requires a very high index of suspicion. This systematic review aims to evaluate prosthetic valve infective endocarditis due to M chimaera. Based on the current literature review, transesophageal echocardiography and 18F-fluorodeoxyglucose positron emission tomography/computed tomography are the most common imaging modalities used to establish the diagnosis. Based on 22 published cases, the reported cases of M chimaera endocarditis have occurred almost entirely in males. Within this cohort, the patients developed endocarditis on average 2.7 years after exposure to contaminated heater-cooler systems during cardiac surgery. M chimaera infection is associated with significant morbidity and mortality.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis , Prótesis Valvulares Cardíacas , Mycobacterium , Masculino , Humanos , Endocarditis/diagnóstico por imagen , Endocarditis/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/microbiología
2.
J Infect Dev Ctries ; 15(3): 404-414, 2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33839716

RESUMEN

INTRODUCTION: Infections caused by extensively-drug resistant (XDR) and pan-drug resistant (PDR) Klebsiella pneumoniae represent an emerging threat due to the high associated mortality. This study aimed to characterize two carbapenem resistant K. pneumoniae strains from the same patient, the first being PDR (referred to as IMP 1078b) and the second being XDR (referred to IMP 1078s) isolated from the same patient. METHODOLOGY: Antimicrobial susceptibility testing was done for the 2 K. pneumoniae isolates, followed by carbapenem/ß-lactamase inhibitor combination assay, and fitness cost against cefepime and meropenem. Then, whole-genome sequence analysis was performed to decipher the molecular mechanisms behind the high level of resistance recorded in both isolates. Finally, qRT-PCR was done for ß-lactam resistant genes. RESULTS: This is the first report about a K. pneumoniae isolate harboring 47 antimicrobial resistance genes and having type IV pilli (Yersinia) and the fimbrial adherence determinant Stb (Salmonella) as virulence factors. Further analysis on both isolates are discussed within the article. CONCLUSION: The co-existence of a high number of antimicrobial resistant (AMR) genes and virulence factor genes may lead to a life threatening invasive and untreatable infection.


Asunto(s)
Antibacterianos/farmacología , Farmacorresistencia Bacteriana Múltiple/genética , Klebsiella pneumoniae/efectos de los fármacos , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Catéteres/etiología , Salud Global , Humanos , Infecciones por Klebsiella/epidemiología , Klebsiella pneumoniae/genética , Masculino , Factores de Virulencia , Adulto Joven
3.
J Infect Public Health ; 12(3): 434-437, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30049610

RESUMEN

We report a case of Pseudomonas stutzeri endocarditis in Lebanon. The patient had a recent history of prosthetic aortic valve replacement and presented to the emergency department with fever and chills. Transesophageal echocardiography confirmed the presence of a vegetation on the prosthetic valve and blood cultures yielded P. stutzeri. The patient was treated with surgery and antibiotics but deteriorated and passed away four days after admission. To our knowledge, this is the fifth case of P. stutzeri endocarditis reported in the literature, and the first case with early presentation and mortality.


Asunto(s)
Válvula Aórtica , Endocarditis Bacteriana/diagnóstico , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas/efectos adversos , Pseudomonas stutzeri/aislamiento & purificación , Anciano , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Ceftazidima/administración & dosificación , Ceftazidima/uso terapéutico , Escalofríos/etiología , Diagnóstico Diferencial , Ecocardiografía Transesofágica , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/tratamiento farmacológico , Humanos , Infusiones Intravenosas , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/complicaciones , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...