Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Sci Rep ; 14(1): 15986, 2024 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-38987641

RESUMEN

The purpose of the present study is to evaluate whether an online reference system (ORS, STATdx Elsevier, Amsterdam, Netherlands) impacts finding the histologically confirmed diagnosis of rare or atypical abdominal tumors and lesions in radiologic imaging. In total, 101 patients with rare tumor entities or lesions and atypical manifestations of common tumors were enrolled retrospectively. Blinded readings were performed by four radiologists with varying levels of experience, who reported on: (a) correct diagnosis (CD), (b) time needed to find the diagnosis, and (c) diagnostic confidence, initially without followed by the assistance of the ORS. The experienced reader (3 years of experience post-residency, CD 49.5%), as well as the advanced reader with 1 year of experience post-residency (CD 43.6%), and a resident with 5 years of experience (CD 46.5%) made the correct diagnosis more frequently compared to the less experienced reader (CD 25.7%). A significant improvement in making the correct diagnosis was only achieved by the advanced reader, the resident with 5 years of experience (CD with ORS 58.4%; p < 0.001). The advanced reader with 1 year of experience post-residency improved slightly (CD ORS 47.5%). The experienced reader (CD ORS 50.5%) and the less experienced reader (CD ORS 27.7%) did not improve significantly. The overall subjective confidence increased significantly when ORS was used (3.2 ± 0.9 vs. 3.8 ± 0.9; p < 0.001). While the ORS had a positive impact on making the correct diagnosis throughout all readers, it favored radiologists with more clinical experience rather than inexperienced residents. Moreover, the ORS increased the diagnostic confidence of all radiologists significantly. In conclusion, the ORS had no significant impact on the diagnosis of rare or atypical abdominal tumors and lesions except for one reader. The greatest benefit is the increase in diagnostic confidence.


Asunto(s)
Neoplasias Abdominales , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Adulto , Neoplasias Abdominales/diagnóstico , Neoplasias Abdominales/patología , Estudios Retrospectivos , Anciano de 80 o más Años , Adulto Joven , Adolescente , Sistemas en Línea
2.
J Cachexia Sarcopenia Muscle ; 15(4): 1430-1440, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38859660

RESUMEN

BACKGROUND: Acute pulmonary embolism (APE) is a potentially life-threatening disorder, emphasizing the importance of accurate risk stratification and survival prognosis. The exploration of imaging biomarkers that can reflect patient survival holds the potential to further enhance the stratification of APE patients, enabling personalized treatment and early intervention. Therefore, in this study, we develop computed tomography pulmonary angiography (CTPA) radiomic signatures for the prognosis of 7- and 30-day all-cause mortality in patients with APE. METHODS: Diagnostic CTPA images from 829 patients with APE were collected. Two hundred thirty-four features from each skeletal muscle (SM), intramuscular adipose tissue (IMAT) and both tissues combined (SM + IMAT) were calculated at the level of thoracic vertebra 12. Radiomic signatures were derived using 10 times repeated three-fold cross-validation on the training data for SM, IMAT and SM + IMAT for predicting 7- and 30-day mortality independently. The performance of the radiomic signatures was then evaluated on held-out test data and compared with the simplified pulmonary embolism severity index (sPESI) score, a well-established biomarker for risk stratification in APE. Predictive accuracy was assessed by the area under the receiver operating characteristic curve (AUC) with a 95% confidence interval (CI), sensitivity and specificity. RESULTS: The radiomic signatures based on IMAT and a combination of SM and IMAT (SM + IMAT) achieved moderate performance for the prediction of 30-day mortality on test data (IMAT: AUC = 0.68, 95% CI [0.57-0.78], sensitivity = 0.57, specificity = 0.73; SM + IMAT: AUC = 0.70, 95% CI [0.60-0.79], sensitivity = 0.74, specificity = 0.54). Radiomic signatures developed for predicting 7-day all-cause mortality showed overall low performance. The clinical signature, that is, sPESI, achieved slightly better performance in terms of AUC on test data compared with the radiomic signatures for the prediction of both 7- and 30-day mortality on the test data (7 days: AUC = 0.73, 95% CI [0.67-0.79], sensitivity = 0.92, specificity = 0.16; 30 days: AUC = 0.74, 95% CI [0.66-0.82], sensitivity = 0.97, specificity = 0.16). CONCLUSIONS: We developed and tested radiomic signatures for predicting 7- and 30-day all-cause mortality in APE using a multicentric retrospective dataset. The present multicentre work shows that radiomics parameters extracted from SM and IMAT can predict 30-day all-cause mortality in patients with APE.


Asunto(s)
Tejido Adiposo , Músculo Esquelético , Embolia Pulmonar , Humanos , Embolia Pulmonar/mortalidad , Embolia Pulmonar/diagnóstico por imagen , Masculino , Femenino , Tejido Adiposo/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Pronóstico , Enfermedad Aguda , Angiografía por Tomografía Computarizada/métodos , Radiómica
3.
J Am Heart Assoc ; 13(9): e031816, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639365

RESUMEN

BACKGROUND: Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience. METHODS AND RESULTS: This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023. Baseline demographics, angiographic outcome, and clinical outcome evaluated by the modified Rankin Scale score at discharge were noted. A multivariate analysis was conducted to test whether these variables were associated with an unfavorable outcome, defined as modified Rankin Scale score >3. A total of 137 patients with acute ischemic stroke (48 vaccinated and 89 unvaccinated) with acute or subsided COVID-19 infection who underwent mechanical thrombectomy attributable to vessel occlusion were included in the study. Angiographic outcomes between vaccinated and unvaccinated patients were similar (modified Thrombolysis in Cerebral Infarction ≥2b: 85.4% in vaccinated patients versus 86.5% in unvaccinated patients; P=0.859). The rate of functional independence (modified Rankin Scale score, ≤2) was 23.3% in the vaccinated group and 20.9% in the unvaccinated group (P=0.763). The mortality rate was 30% in both groups. In the multivariable analysis, vaccination status was not a significant predictor for an unfavorable outcome (P=0.957). However, acute COVID-19 infection remained significant (odds ratio, 1.197 [95% CI, 1.007-1.417]; P=0.041). CONCLUSIONS: Our study demonstrated no impact of COVID-19 vaccination on angiographic or clinical outcome of COVID-19-positive patients with acute ischemic stroke undergoing mechanical thrombectomy, whereas worsening attributable to COVID-19 was confirmed.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Accidente Cerebrovascular Isquémico , Trombectomía , Vacunación , Humanos , COVID-19/complicaciones , COVID-19/terapia , COVID-19/mortalidad , Masculino , Femenino , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/cirugía , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Vacunas contra la COVID-19/efectos adversos , SARS-CoV-2 , Anciano de 80 o más Años
4.
Neuroradiol J ; 37(3): 336-341, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38490750

RESUMEN

OBJECTIVES: Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best. MATERIALS AND METHODS: 35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists. RESULTS: The absolute maximum of CNR was 8.12 ± 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV ≤110 and keV ≥180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers. CONCLUSIONS: The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.


Asunto(s)
Gliosis , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Artefactos , Gliosis/diagnóstico por imagen , Gliosis/patología , Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética , Radiólogos , Estándares de Referencia , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Sustancia Blanca/diagnóstico por imagen
5.
Acad Radiol ; 31(7): 2715-2724, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38368163

RESUMEN

RATIONALE AND OBJECTIVES: Accurate and efficient estimation of patient height and weight is crucial to ensure patient safety and optimize the quality of magnetic resonance imaging (MRI) procedures. Several height and weight estimation methods have been proposed for use in adult patient management, but none is widely established. Estimation by the medical technologists for radiology (MTR) based on personal experience remains to be the most common method. This study aimed to compare a novel deep learning (DL)-based 3-dimensional (3D) camera estimation method to MTR staff in terms of estimation accuracy. METHODS: A retrospective study was conducted to compare the accuracy of height and weight estimation with a DL-based 3D camera algorithm to the accuracy of height and weight estimation by the MTR. Depth images of the patients were captured during the regular imaging workflow on a low field 0.55 T MRI scanner (MAGNETOM Free.Max, Siemens Healthineers, Erlangen, Germany) and then processed retrospectively. Depth images of a total of 161 patients were used to validate the accuracy of the height and weight estimation algorithm. The accuracy of each estimation method was evaluated by computing the proportions of the estimates within 5% and 15% of actual height (PH05, PH15) and within 10% and 20% of actual weight (PW10, PW20). An acceptable accuracy for height estimation was predetermined to be PH05 = 95% and PH15 = 99% and an acceptable accuracy for weight estimation was predetermined to be PW10 = 70% and PW20 = 95%. The bias in height and weight estimation was measured by the mean absolute percentage error (MAPE). RESULTS: The retrospective study included 161 adult patients. For 148/161 patients complying with inclusion criteria, DL-based 3D camera algorithm outperformed the MTR in estimating the patient's height and weight in term of accuracy (3D camera: PH05 =98.6%, PH15 =100%, PW10 =85.1%, PW20 =95.9%; MTR: PH05 =92.5%, PH15 =100%, PW10 =75.0%, PW20 =93.2%). MTR had a slightly higher bias in their estimates compared to the DL-based 3D camera algorithm (3D camera: MAPE height=1.8%, MAPE weight=5.6%, MTR: MAPE height=2.2%, MAPE weight=7.5%) CONCLUSION: This study has demonstrated that the estimation of the patient's height and weight by a DL-based 3D camera algorithm is accurate and robust. It has the potential to complement the regular MRI workflows, by providing further automation during patient registration.


Asunto(s)
Estatura , Peso Corporal , Aprendizaje Profundo , Estudios de Factibilidad , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Masculino , Femenino , Imagenología Tridimensional/métodos , Adulto , Persona de Mediana Edad , Algoritmos , Anciano
6.
Neuroradiology ; 66(5): 729-736, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38411902

RESUMEN

PURPOSE: To determine the optimal virtual monoenergetic image (VMI) for detecting and assessing intracranial hemorrhage in unenhanced photon counting CT of the head based on the evaluation of quantitative and qualitative image quality parameters. METHODS: Sixty-three patients with acute intracranial hemorrhage and unenhanced CT of the head were retrospectively included. In these patients, 35 intraparenchymal, 39 intraventricular, 30 subarachnoidal, and 43 subdural hemorrhages were selected. VMIs were reconstructed using all available monoenergetic reconstruction levels (40-190 keV). Multiple regions of interest measurements were used for evaluation of the overall image quality, and signal, noise, signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) of intracranial hemorrhage. Based on the results of the quantitative analysis, specific VMIs were rated by five radiologists on a 5-point Likert scale. RESULTS: Signal, noise, SNR, and CNR differed significantly between different VMIs (p < 0.001). Maximum CNR for intracranial hemorrhage was reached in VMI with keV levels > 120 keV (intraparenchymal 143 keV, intraventricular 164 keV, subarachnoidal 124 keV, and subdural hemorrhage 133 keV). In reading, no relevant superiority in the detection of hemorrhage could be demonstrated using VMIs above 66 keV. CONCLUSION: For the detection of hemorrhage in unenhanced CT of the head, the quantitative analysis of the present study on photon counting CT is generally consistent with the findings from dual-energy CT, suggesting keV levels just above 120 keV and higher depending on the location of the hemorrhage. However, on the basis of the qualitative analyses, no reliable statement can yet be made as to whether an additional VMI with higher keV is truly beneficial in everyday clinical practice.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Estudios Retrospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Hemorragias Intracraneales/diagnóstico por imagen , Relación Señal-Ruido
7.
Acad Radiol ; 31(2): 686-692, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37393176

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the potential to reduce the amount of iodinated contrast media (CM) for computer tomographic pulmonary angiography (CTPA) with a novel photon-counting-detector CT (PCCT). MATERIALS AND METHODS: Overall, 105 patients referred for CTPA were retrospectively included in this study. CTPA was performed using bolus tracking and high-pitch dual-source scanning (FLASH mode) on a novel PCCT (Naeotom Alpha, Siemens Healthineers). CM (Accupaque 300, GE Healthcare) dose was lowered stepwise following the introduction of the new CT scanner. Thus, patients could be divided into 3 groups as follows: group 1, n = 29, 35 ml of CM; group 2, n = 62, 45 ml of CM and group 3, n = 14, 60 ml of CM. Four readers independently assessed the image quality (Likert-scale 1-5) and adequate assessment of the segmental pulmonary arteries. Additionally, the pulmonary arterial contrast opacification was measured. RESULTS: The subjective image quality was rated highest in group 1 with 4.6 compared to 4.5 (group 2) and 4.1 (group 3) with a significant difference between groups 1 and 3 (p < 0.001) and between groups 2 and 3 (p = 0.003). In all groups, almost all segmental pulmonary arteries could be assessed adequately without significant differences (18.5 vs. 18.7 vs. 18.4). Mean attenuation in the pulmonary trunk did not differ significantly between groups 321 ± 92 HU versus 345 ± 93 HU versus 347 ± 88 HU (p = 0.69). CONCLUSION: Significant CM dose reduction is possible without a reduction in image quality. PCCT enables diagnostic CTPA with 35 ml of CM.


Asunto(s)
Medios de Contraste , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Arteria Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Angiografía/métodos , Angiografía por Tomografía Computarizada/métodos , Dosis de Radiación
8.
Clin Neuroradiol ; 34(1): 75-83, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37589739

RESUMEN

PURPOSE: Nonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application. METHODS: A total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists. RESULTS: In most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best. CONCLUSION: In nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Cráneo/diagnóstico por imagen
9.
Medicine (Baltimore) ; 102(47): e36069, 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38013308

RESUMEN

The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner. Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort. In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, MAGNETOM Free.Max, Siemens Healthineers) or the standard MRI scanner (n = 86, MAGNETOM Avanto Fit, Siemens Healthineers). Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure. In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.g., mean ratings for claustrophobia: standard MRI scanner = 4.63 ± 1.04, low field MRI scanner = 4.65 ± 1.02). However, when asked for a comparison, patients did favor the more spacious low field MRI scanner. In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.72 ± 1.46 [median 4 = "rather not unpleasant"], low field MRI scanner = 4.26 ± 1.22 [median 5 = "not unpleasant at all"]). Patients did not perceive any significant difference in terms of vertigo between both MRI scanners. The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients. Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.


Asunto(s)
Comodidad del Paciente , Trastornos Fóbicos , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Vértigo/diagnóstico por imagen , Percepción
10.
Front Psychol ; 14: 1218526, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37701875

RESUMEN

Background and objectives: Emotional and cognitive deficits are prevalent in strokes involving the thalamus. In contrast to cognitive deficits, emotional deficits have not been studied prospectively in isolated thalamic stroke. Methods: In 37 ischemic thalamic stroke patients (57.0 [50.0; 69.5] years [median (Q1; Q3)], 21 males, 5 anterior, 12 paramedian, 20 inferolateral vascular territory), and 37 non-stroke control patients matched for age and sex, we prospectively examined depression, anxiety, activities of daily living, and quality of life at 1, 6, 12, and 24 months post-stroke using the Hospital-Anxiety-and-Depression Scale (HADS), Nürnberger-Alters-Alltagsaktivitäten scale (NAA), and Short Form-36 (SF36) questionnaire. Voxel-based lesion-symptom mapping (VLSM) and lesion-subtraction analyzes were performed to determine associations between questionnaire scores and thalamic stroke topography. Results: At 1 month post-stroke, anterior thalamic stroke patients had higher depression scores [8.0 (7.5; 10.5)] than paramedian [4.5 (1.0; 5.8)] and inferolateral [4.0 (1.0; 7.0)] thalamic stroke patients. Furthermore, anterior thalamic stroke patients had higher anxiety scores [11.0 (8.0; 14.5)] than their matched controls [2.5 (2.0; 2.5)], paramedian [4.5 (1.0; 5.8)] and inferior [4.0 (1.0; 7.0)] thalamic stroke patients. Depression and anxiety scores in anterior thalamic stroke patients remained high across the follow-up [depression: 9.0 (3.5; 13,8); anxiety:10.05 (2.8, 14.5)].Physical health assessed by SF36 was intact in anterior [1 month post-stroke: T-score = 55.9 (37.0; 57.6)] but reduced in inferolateral [44.5(32.4; 53.1)] thalamic stroke, whereas mental health was reduced in anterior thalamic stroke [32.0 (29.8; 47.3)].VLSM confirmed that voxels in the anterior thalamus around Montreal Neurological Institute (MNI) coordinates X = -8, Y = -12, Z = 2 were more often affected by the stroke in depressed (HADS-score ≥ 8) than non-depressed (HADS-score < 8) patients and voxels around coordinates X = -10, Y = -12, Z = 2 were more often affected in anxious (HADS-score ≥ 8) than non-anxious (HADS-score < 8) patients. Conclusion: Anterior, but not paramedian or inferolateral thalamic stroke was associated with depression and anxiety. Even though our results are mostly significant in the left thalamus, this observation on stroke laterality might be confounded by the fact that the right hemisphere was underrepresented in our study.

11.
J Clin Med ; 12(5)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36902704

RESUMEN

OBJECTIVES: Low-field MRI at 0.55 Tesla (T) with deep learning image reconstruction has recently become commercially available. The objective of this study was to evaluate the image quality and diagnostic reliability of knee MRI performed at 0.55T compared with 1.5T. METHODS: A total of 20 volunteers (9 female, 11 male; mean age = 42 years) underwent knee MRI on a 0.55T system (MAGNETOM Free.Max, Siemens Healthcare, Erlangen, Germany; 12-channel Contour M Coil) and a 1.5T scanner (MAGNETOM Sola, Siemens Healthcare, Erlangen, Germany; 18-channel transmit/receive knee coil). Standard two-dimensional (2D) turbo spin echo (TSE), fat-suppressed (fs) proton density-weighted (PDw), T1w TSE, and T2w TSE sequences were acquired in approximately 15 min. In total, 2 radiologists blinded to the field strength subjectively assessed all MRI sequences (overall image quality, image noise, and diagnostic quality) using a 5-point Likert scale (1-5; 5 = best). Additionally, both radiologists evaluated the possible pathologies of menisci, ligaments, and cartilage. Contrast ratios (CRs) of different tissues (bone, cartilage, and menisci) were determined on coronal PDw fs TSE images. The statistical analysis included Cohen's kappa and the Wilcoxon rank sum test. RESULTS: The overall image quality of the 0.55T T2w, T1w, and PDw fs TSE sequences was diagnostic and rated similar for T1w (p > 0.05), but lower for PDw fs TSE and T2w TSE compared with 1.5T (p < 0.05). The diagnostic accordance of meniscal and cartilage pathologies at 0.55T was similar to 1.5T. The CRs of the tissues were not significantly different between 1.5T and 0.55T (p > 0.05). The inter-observer agreement of the subjective image quality was generally fair between both readers and almost perfect for the pathologies. CONCLUSIONS: Deep learning-reconstructed TSE imaging at 0.55T yielded diagnostic image quality for knee MRI compared with standard 1.5T MRI. The diagnostic performance of meniscal and cartilage pathologies was equal for 0.55T and 1.5T without a significant loss of diagnostic information.

12.
World Neurosurg ; 167: e386-e396, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35963612

RESUMEN

OBJECTIVE: To report our initial experience with the novel low-profile APERIO Hybrid17 Thrombectomy Device (AP17) for proximal and distal vessel occlusions in acute ischemic stroke. METHODS: A multicentric retrospective analysis of patients treated with the AP17 was performed. The primary effectiveness endpoint was first-pass TICI ≥2b (Thrombolysis in cerebral infarction scale). The primary safety endpoint was the occurrence of hemorrhagic complications. Further outcome measures were number of passes, device-related complications, and 3-month functional outcome. RESULTS: The AP17 was used in 71 patients (mean age: 73 years) with a median baseline National Institutes of Health Stroke Scale score of 9. Treated vessels were the carotid-T in 8 cases (11%), the M1-segment in 16 (23%), the M2-segment in 29 (41%), the anterior cerebral artery in 3 (4%), and basilar/posterior cerebral arteries in 15 (21%). The rates of first-pass and final TICI ≥2b were 75.6% and 92.7%, retrospectively, with a mean number of passes of 3 ± 2. Final TICI ≥2b rates were comparable between large and medium vessel occlusions. Symptomatic intracranial hemorrhages were recorded in 2 cases (2.8%). At 3-month clinical follow-up, a modified Rankin scale score ≤2 was achieved in 69.0% (29/42). The all-cause mortality at discharge was 17.4%. CONCLUSIONS: The AP17 was associated with a reasonable safety and efficacy profile for both proximal and distal vessel occlusions. These results may contribute to establish mechanical thrombectomy for distal occlusions.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Anciano , Accidente Cerebrovascular/etiología , Isquemia Encefálica/etiología , Accidente Cerebrovascular Isquémico/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Trombectomía/métodos , Stents/efectos adversos
13.
Diagnostics (Basel) ; 12(6)2022 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-35741116

RESUMEN

BACKGROUND: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. METHODS: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40-120 keV). Additionally, two radiologists rated the perceived image quality. RESULTS: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60-65 keV was rated as best image quality. CONCLUSION: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.

14.
Diagnostics (Basel) ; 12(6)2022 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-35741251

RESUMEN

This study aims to investigate the qualitative and quantitative image quality of low-dose high-resolution (LD-HR) lung CT scans acquired with the first clinical approved photon counting CT (PCCT) scanner. Furthermore, the radiation dose used by the PCCT is compared to a conventional CT scanner with an energy-integrating detector system (EID-CT). Twenty-nine patients who underwent a LD-HR chest CT scan with dual-source PCCT and had previously undergone a LD-HR chest CT with a standard EID-CT scanner were retrospectively included in this study. Images of the whole lung as well as enlarged image sections displaying a specific finding (lesion) were evaluated in terms of overall image quality, image sharpness and image noise by three senior radiologists using a 5-point Likert scale. The PCCT images were reconstructed with and without a quantum iterative reconstruction algorithm (PCCT QIR+/−). Noise and signal-to-noise (SNR) were measured and the effective radiation dose was calculated. Overall, image quality and image sharpness were rated best in PCCT (QIR+) images. A significant difference was seen particularly in image sections of PCCT (QIR+) images compared to EID-CT images (p < 0.005). Image noise of PCCT (QIR+) images was significantly lower compared to EID-CT images in image sections (p = 0.005). In contrast, noise was lowest on EID-CT images (p < 0.001). The PCCT used significantly less radiation dose compared to the EID-CT (p < 0.001). In conclusion, LD-HR PCCT scans of the lung provide better image quality while using significantly less radiation dose compared to EID-CT scans.

15.
Stroke ; 53(6): 1904-1914, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35259928

RESUMEN

BACKGROUND: The thalamus plays an essential role in cognition. Cognitive deficits have to date mostly been studied retrospectively in chronic thalamic stroke in small cohorts. Studies prospectively evaluating the evolution of cognitive deficits and their association with thalamic stroke topography are lacking. This knowledge is relevant for targeted patient diagnostics and rehabilitation. METHODS: Thirty-seven patients (57.5±17.5 [mean±SD] years, 57% men) with first-ever acute isolated ischemic stroke covering the anterior (n=5), paramedian (n=12), or inferolateral (n=20) thalamus and 37 in-patient controls without stroke with similar vascular risk factors matched for age and sex were prospectively studied. Cognition was evaluated using predefined tests at 1, 6, 12, and 24 months. Voxel-based lesion-symptom mapping was used to determine associations between neuropsychological deficits and stroke topography. RESULTS: Patients with anterior thalamic stroke revealed severe deficits in verbal memory (median T score [Q1-Q3]: 39.1 [36.1-44.1]), language (31.8 [31.0-43.8]), and executive functions (43.8 [35.5-48.1]) at 1 month compared with controls (verbal memory: 48.5 [43.6-61.0], language: 55.7 [42.3-61.1], executive functions: 51.3 [50.1-56.8]). Patients with paramedian thalamic stroke showed moderate language (44.7 [42.8-55.9]) and executive (49.5 [44.3-55.1]) deficits and no verbal memory deficits (48.1 [42.5-54.7]) at 1 month compared with controls (59.0 [47.0-64.5]; 59.6 [51.1-61.3]; 52.5 [44.2-55.3]). The language and executive deficits in paramedian thalamic stroke patients almost completely recovered during follow-up. Intriguingly, significant deficits in verbal memory (44.7 [41.5-51.9]), language (47.5 [41.8-54.1]), and executive functions (48.2 [46.2-59.7]) were found in inferolateral thalamic stroke patients at 1 month compared with controls (50.5 [46.7-59.9]; 57.0 [51.2-62.9]; 57.4 [51.2-60.7]). Language, but not executive deficits persisted during follow-up. Voxel-based lesion-symptom mapping revealed an association of verbal memory deficits with anterior thalamus lesions and an association of non-verbal memory, language, and executive deficits with lesions at the anterior/paramedian/inferolateral border. CONCLUSIONS: All 3 stroke topographies exhibited significant deficits in diverse cognitive domains, which recovered to a different degree depending on the stroke localization. Our study emphasizes the need for comprehensive neuropsychological diagnostics to secure adequate patient rehabilitation.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Estudios de Casos y Controles , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Trastornos de la Memoria , Pruebas Neuropsicológicas , Estudios Retrospectivos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/patología , Tálamo/diagnóstico por imagen , Tálamo/patología
16.
Ther Adv Neurol Disord ; 13: 1756286420911295, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32313555

RESUMEN

BACKGROUND: The present study evaluates the possible prognostic benefits of 7 T susceptibility weighted imaging (SWI) of traumatic cerebral microbleeds (TMBs) over 3 T SWI to predict the acute clinical state and subjective impairments, including health-related quality of life (HRQOL), after closed head injury (CHI). METHODS: The study group comprised 10 participants with known TMBs All subjects underwent 3 T magnetic resonance imaging (MRI) and 7 T MRI, respectively. Location and count of TMBs were independently evaluated by two neuroradiologists. The initial Glasgow Coma Scale (GCS), the duration of coma and further clinical data were taken from the patients records. HRQOL was assessed by means of a questionnaire. Memory complaints and neurological symptoms were inquired at the time of the MRI examinations. RESULTS: SWI revealed a total of 485 TMBs at 3 T, 584 TMBs at 7 T with similar spatial resolution, and 684 TMBs at 7 T with a factor of 10 higher spatial resolution. The TMBs depicted by 7 T high-resolution SWI were correlated with the duration of coma (Spearman's rho of 0.77). The corresponding association with TMBs in 3 T MRI SWI showed a Spearman's rho of 0.71. The initial GCS score and TMBs correlated with a Spearman's rho of -0.35 at 3 T SWI MRI and a rho of -0.33 at 7 T high-resolution SWI, respectively. The physical aspect of HRQOL correlated substantially with the count of TMBs (rho = 0.44 for 3 T SWI and rho = 0.35 for both 7 T SWI sequences, respectively). CONCLUSIONS: The number of TMBs showed a substantial association with indicators of the acute clinical state and chronic neurobehavioral parameters after CHI, but there was no additional advantage of 7 T MRI. These preliminary findings warrant a larger prospective study for the future.

17.
Acad Radiol ; 27(6): e123-e131, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31445824

RESUMEN

RATIONALE AND OBJECTIVES: This retrospective single-center study aims to evaluate endovascular therapy (EVT) of cranial dural arteriovenous fistulas (dAVF) with ethylene vinyl alcohol (EVOH) copolymer (Onyx) regarding occlusion rates, complications, and recurrences. MATERIAL AND METHODS: From January 2008 to April 2018, 75 patients with dAVF (41 men, 34 women; mean age 56 years) underwent EVT with the nonadhesive liquid embolic agent as primary treatment. Patient records and angiograms were reviewed for demographic data, symptoms, fistula type and size, number of EVTs, amount of embolic material, occlusion rates, and recurrences. RESULTS: Seventy-five patients with dAVFs were primarily embolized with EVOH in 96 EVTs. According to the Merland-Cognard classification the majority of dAVFs treated were type 4 (42.7%), followed by type 2a (18.7%), type 2a+b (17.3%), type 1 (8%), type 2b (5.3%), type 3 (5.3%), and type 5 (2.7%). Complete occlusion (CO) of the dAVF was achieved in 45/75 (60%) of cases after a single EVT and in 58 (77%) patients after one or several EVTs. Seven patients (9%) required additional surgical therapy for CO. Successful treatment was achieved for 70/75 (93%) patients including 10 (13%) patients with residual dAVFs type 1-2a. Recurrence after CO occurred in one (1.3%) patient and four (5.3%) patients remained refractory to therapy with dAVFs type > 2a. Procedure-related permanent morbidity occurred in 4/75 (5.3%) patients. CONCLUSION: For more than a decade transarterial EVOH embolization has established as the first-line treatment for cranial dAVFs with high cure rates and low rates of complications and recurrences. Additional neurosurgical therapy is rarely required for curative treatment.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Embolización Terapéutica , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Angiografía Cerebral , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polivinilos , Estudios Retrospectivos , Resultado del Tratamiento
19.
Acad Radiol ; 26(10): e298-e304, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30587388

RESUMEN

RATIONALE AND OBJECTIVES: Mechanical thrombectomy is common practice in proximal anterior vessel occlusion. However, it remains unclear whether peripheral artery occlusions should be treated as well. This retrospective study aimed to prove the effectiveness of endovascular recanalization treatment for the M2 segment by comparison of intracranial internal carotid artery (ICA), M1 segment, and M2 segment thrombectomy. MATERIALS AND METHODS: All patients who received endovascular treatment for distal ICA, M1, or M2 segment occlusions between January 2010 and July 2017 at our center were re-analyzed with respect to reperfusion success, interventional and clinical parameters. Statistical analysis was performed by Mann Whitney test, Chi square test, and Spearman correlation analysis. RESULTS: A total of 261 patients (median age, 72 years), 100 with ICA, 137 with M1, and 24 with M2 segment occlusion, were included. Duration of endovascular treatment was significantly longer in ICA occlusions (median, 83 minutes, p < 0.001) compared to M1 (56 minutes) or M2 segment occlusions (49 minutes). Recanalization and reperfusion success and rate of endovascular complications did not differ between occlusion sites (AOL, p = 0.071; mTICI, p = 0.540; complications, p = 0.064). No significant difference in revascularization success was found between the different thrombectomy devices (direct thrombus aspiration, stent retrieving, or a sequential combined approach; p = 0.112). Successful M2 recanalization (mTICI 2b-3) correlated significantly with stronger posttherapeutic NIHSS reduction (r = 0.691, p < 0.001). CONCLUSION: We found endovascular treatment of M2 segment occlusions as safe and successful as endovascular therapy of the ICA or M1 segment, with stronger posttherapeutic NIHSS reduction after successful compared to insufficient M2 recanalization.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Arteria Carótida Interna/cirugía , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Anciano , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
20.
Neuroradiology ; 60(12): 1267-1272, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30219935

RESUMEN

PURPOSE: Computer-aided diagnosis (CAD) appears promising in early ischemic change detection computed tomography (CT). This study aimed to compare the performance of two new CAD systems (Frontier ASPECTS Prototype and Brainomix) with two experienced readers in selected patients with suspected acute ischemic stroke. METHODS: Retrospectively, non-contrast brain CTs of 150 patients suspected for acute middle cerebral artery ischemia were analyzed with respect to ASPECTS first separately, than in consensus by two senior radiologists, and by use of Frontier and Brainomix. Besides the fully automatic Frontier and Brainomix readings (Frontier_1, Brainomix_1), readings adjusted for the affected brain side (known by CT angiography or clinical presentation, Frontier_2, Brainomix_2) were assessed. Statistical analysis was performed by intraclass correlation and Bland-Altman statistics. RESULTS: The score-based ASPECTS readings of Brainomix_1, Brainomix_2, both radiologists, and the expert consensus reading correlated highly (r = 0.714 to 0.841; always p < 0.001), whereas Frontier_1 and Frontier_2 correlated only lowly or moderately with both radiologists, the expert consensus reading, and Brainomix (r = 0.471 to 0.680; always p < 0.001). Bland-Altman analysis revealed lower mean ASPECT difference and standard deviation of difference for Brainomix_2 (mean difference = -0.2; SD = 1.15) compared to Frontier_2 (mean difference = 1.2; SD = 1.76). Correlation of region-based ASPECTS reading with the expert consensus reading was moderate for Brainomix_2 (r = 0.534), but only low for Frontier_2 (r = 0283; always p < 0.001). CONCLUSION: We found high agreement in ASPECTS rating between both radiologists, expert consensus reading, and Brainomix, but only low to moderate agreement to Frontier.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Diagnóstico por Computador/instrumentación , Aumento de la Imagen/instrumentación , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Anciano , Anciano de 80 o más Años , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA