RESUMEN
ABSTRACT Introduction: The ureteral access sheath (UAS) is a medical device that enables repeated entrance into the ureter and collecting system during retrograde intrarenal surgery (RIRS). Its impact on stone-free rates, ureteral injuries, operative time, and postoperative complications remains controversial. Therefore, we performed a systematic review and meta-analysis comparing RIRS with versus without UAS for urolithiasis management. Purpose: To compare outcomes from retrograde intrarenal surgery (RIRS) for stone extraction with or without ureteral access sheath (UAS); evaluating stone-free rate (SFR), ureteral injuries, operative time, and postoperative complications. Materials and Methods: We systematically searched PubMed, Embase, and Cochrane Library in June 2024 for randomized controlled trials (RCTs) evaluating the efficacy and safety outcomes of UAS use in RIRS for urolithiasis treatment. Articles published between 2014 and 2024 were included. Pooled risk ratios (RRs) and mean differences (MDs) were calculated for binary and continuous outcomes, respectively. Results: Five RCTs comprising 466 procedures were included. Of these, 246 (52.7%) utilized UAS. The follow-up ranged from 1 week to 1 month. UAS reduced the incidence of postoperative fever (RR 0.49; 95% confidence interval [CI] 0.29-0.84; p=0.009), and postoperative infection (RR 0.50; 95% CI 0.30-0.83; p=0.008). There were no significant differences between groups in terms of SFR (RR 1.05; 95% CI 0.99-1.11; p=0.10), ureteral injuries (RR 1.29; 95% CI 0.95-1.75; p=0.11), operative time (MD 3.56 minutes; 95% CI −4.15 to 11.27 minutes; p=0.36), or length of stay (MD 0.32 days; 95% CI −0.42 to 1.07 days; p=0.40). Conclusion: UAS leads to a lower rate of post-operative fever and infection. However, UAS did not significantly reduce or increase the SFR or the rate of ureteral injuries during RIRS for patients with urolithiasis. The use of UAS should be considered to decrease the risk of infectious complications, particularly in those who may be at higher risk for such complications.
RESUMEN
INTRODUCTION: The ureteral access sheath (UAS) is a medical device that enables repeated entrance into the ureter and collecting system during retrograde intrarenal surgery (RIRS). Its impact on stone-free rates, ureteral injuries, operative time, and postoperative complications remains controversial. Therefore, we performed a systematic review and meta-analysis comparing RIRS with versus without UAS for urolithiasis management. PURPOSE: To compare outcomes from retrograde intrarenal surgery (RIRS) for stone extraction with or without ureteral access sheath (UAS); evaluating stone-free rate (SFR), ureteral injuries, operative time, and postoperative complications. MATERIALS AND METHODS: We systematically searched PubMed, Embase, and Cochrane Library in June 2024 for randomized controlled trials (RCTs) evaluating the efficacy and safety outcomes of UAS use in RIRS for urolithiasis treatment. Articles published between 2014 and 2024 were included. Pooled risk ratios (RRs) and mean differences (MDs) were calculated for binary and continuous outcomes, respectively. RESULTS: Five RCTs comprising 466 procedures were included. Of these, 246 (52.7%) utilized UAS. The follow-up ranged from 1 week to 1 month. UAS reduced the incidence of postoperative fever (RR 0.49; 95% confidence interval [CI] 0.29-0.84; p=0.009), and postoperative infection (RR 0.50; 95% CI 0.30-0.83; p=0.008). There were no significant differences between groups in terms of SFR (RR 1.05; 95% CI 0.99-1.11; p=0.10), ureteral injuries (RR 1.29; 95% CI 0.95-1.75; p=0.11), operative time (MD 3.56 minutes; 95% CI -4.15 to 11.27 minutes; p=0.36), or length of stay (MD 0.32 days; 95% CI -0.42 to 1.07 days; p=0.40). CONCLUSION: UAS leads to a lower rate of post-operative fever and infection. However, UAS did not significantly reduce or increase the SFR or the rate of ureteral injuries during RIRS for patients with urolithiasis. The use of UAS should be considered to decrease the risk of infectious complications, particularly in those who may be at higher risk for such complications.
Asunto(s)
Complicaciones Posoperatorias , Uréter , Humanos , Tempo Operativo , Complicaciones Posoperatorias/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento , Uréter/cirugía , Uréter/lesiones , Urolitiasis/diagnóstico , Urolitiasis/cirugíaRESUMEN
OBJECTIVE: To compare the outcomes of retrograde flexible ureteroscopy (fURS) with retroperitoneal laparoscopic ureterolithotomy (RLU) for large proximal ureteric stones. PATIENTS AND METHODS: A prospective randomised trial was conducted from January 2018 through December 2022 including patients with impacted proximal ureteric stones of 15-25 mm. Patients underwent fURS or RLU. Primary outcome was the stone-free rate. Demographic data, stone features, and complications rates were also compared between groups. RESULTS: A total of 64 patients were enrolled, 32 in each group. The mean impacted stone time was similar between groups, as well as stone size (17 mm) and stone density (>1000 Hounsfield Units). The ureteric stone-free rates between the two groups (93.7% in fURS vs 96.8% in RLU; odds ratio [OR] 0.72, 95% confidence interval [CI] -1.72 to 3.17; P = 0.554), and overall success rates, which take into account residual fragments in the kidney (84.3% in fURS vs 93.7% in RLU; OR 1.02, 95% CI -0.69 to 2.74; P = 0.23), were similar. Operative time was also not statistically significantly different between groups (median 80 vs 82 min; P = 0.101). There was no difference in hospital length of stay. Retropulsion rate was higher with fURS (65.6% vs 3.1%; p < 0.001). Residual hydronephrosis (34.3% each group) and complication rates did no differ according to treatment. CONCLUSION: Flexible URS and RLU are both highly efficient and present low morbidity for large impacted proximal ureteric stone treatment. RLU is not superior to fURS.
Asunto(s)
Laparoscopía , Cálculos Ureterales , Ureteroscopía , Humanos , Ureteroscopía/métodos , Ureteroscopía/efectos adversos , Cálculos Ureterales/cirugía , Masculino , Femenino , Laparoscopía/métodos , Persona de Mediana Edad , Estudios Prospectivos , Adulto , Resultado del Tratamiento , Tempo OperativoRESUMEN
PURPOSE: High-quality evidence comparing supine to prone percutaneous nephrolithotomy (PCNL) for the treatment of complex stones is lacking. This study aimed to compare the outcomes of supine position (SUP) and prone position (PRO) PCNL. MATERIALS AND METHODS: A noninferior randomized controlled trial was performed according to the CONSORT (Consolidated Standards for Reporting Trials) criteria. The inclusion criteria were patients over 18 years of age with complex stones. SUP was performed in the Barts flank-free modified position. Except for positioning, all the surgical parameters were identical. The primary outcome was the difference in the success rate on the first postoperative day (POD1) between groups. The secondary outcome was the difference in the stone-free rate (SFR) on the 90th postoperative day (final SFR). A noninferiority margin of 15% was used. Demographic, operative, and safety variables were compared between the groups. Statistical significance was set at p <0.05. RESULTS: Overall, 112 patients were randomized and their demographic characteristics were comparable. The success rates on POD1 were similar (SUP: 62.5% vs PRO: 57.1%, p=0.563). The difference observed (-5.4%) was lower than the predefined limit. The final SFRs were also similar (SUP: 55.4% vs PRO: 50.0%, p=0.571). SUP had a shorter operative time (mean±SD 117.9±39.1 minutes vs 147.6±38.8 minutes, p <0.001) and PRO had a higher rate of Clavien ≥3 complications (14.3% vs 3.6%, p=0.045). CONCLUSIONS: Positioning during PCNL for complex kidney stones did not impact the success rates; consequently, both positions may be suitable. However, SUP might be associated with a lower high-grade complication rate.
Asunto(s)
Cálculos Renales/cirugía , Nefrolitotomía Percutánea/métodos , Posicionamiento del Paciente , Cistoscopía , Femenino , Fluoroscopía , Humanos , Cálculos Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Posición Prona , Posición Supina , Tomografía Computarizada por Rayos XRESUMEN
OBJECTIVES: To assess the efficacy and safety of single-dose tranexamic acid on the blood transfusion rate and outcomes of patients with complex kidney stones undergoing percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS: In a randomised, double-blinded, placebo-controlled trial, 192 patients with complex kidney stone (Guy's Stone Scores III-IV) were prospectively enrolled and randomised (1:1 ratio) to receive either one dose of tranexamic acid (1 g) or a placebo at the time of anaesthetic induction for PCNL. The primary outcome measure was the occurrence rate of perioperative blood transfusion. The secondary outcome measures included blood loss, operative time, stone-free rate (SFR), and complications. ClinicalTrials.gov identifier: NCT02966236. RESULTS: The overall risk of receiving a blood transfusion was reduced in the tranexamic acid group (2.2% vs 10.4%; relative risk, 0.21, 95% confidence interval [CI] 0.03-0.76, P = 0.033; number-needed-to-treat: 12). Patients randomised to the tranexamic acid group had a higher immediate and 3-month SFR compared with those in the placebo group (29% vs 14.7%, odds ratio [OR] 2.37, 95% CI 1.15-4.87, P = 0.019, and 46.2% vs 28.1%, OR 2.20, 95% CI 1.20-4.02, P = 0.011, respectively). Faster haemoglobin recovery occurred in patients in the tranexamic acid group (mean, 21.3 days; P = 0.001). No statistical differences were found in operative time and complications between groups. CONCLUSIONS: Tranexamic acid administration is safe and reduces the need for blood transfusion by five-times in patients with complex kidney stones undergoing PCNL. Moreover, tranexamic acid may contribute to better stone clearance rate and faster haemoglobin recovery without increasing complications. A single dose of tranexamic acid at the time of anaesthetic induction could be considered standard clinical practice for patients with complex kidney stones undergoing PCNL.
Asunto(s)
Antifibrinolíticos/uso terapéutico , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Cálculos Renales/cirugía , Nefrolitotomía Percutánea , Ácido Tranexámico/uso terapéutico , Adolescente , Adulto , Anciano , Volumen Sanguíneo , Método Doble Ciego , Femenino , Hemoglobinas/metabolismo , Hemostasis Quirúrgica/métodos , Humanos , Masculino , Persona de Mediana Edad , Nefrolitotomía Percutánea/efectos adversos , Tempo Operativo , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Adulto JovenRESUMEN
ABSTRACT Introduction: To demonstrate the entire surgeon's point of view of a prone split-leg (PSL) endoscopic guided percutaneous nephrolithotomy (ePCNL) recorded with a GoPro® camera for standardization of the essential technical steps towards a successful procedure (1). Materials and methods: A 40y.o female patient presented with right flank pain for three years. She had previously been submitted to shock wave lithotripsy without success. Non-contrast computed tomography (NCCT) revealed a 2cm stone in the renal pelvis with 1400HU and stone-to-skin distance of 11cm (Guy's Stone Score 1). PCNL approach was chosen for providing higher chances of stone-free after a single procedure. Informed consent was obtained. The PSL ePCNL was uneventful with a single access in a mid-pole. The surgeon had a Full HD GoPro Hero 4® camera mounted on his head, controlled by the surgical staff with a remote control. All essential surgical steps were recorded. Results: Operative time was 90 minutes. Hemoglobin drop was 0.7g/dL. The post-operative NCCT scan was stone-free. The patient was discharged 24h after surgery. Kidney stent was left with a string and removed after 5days. The camera worked properly and didn't cause any kind of discomfort to the surgeon. The quality of the recorded movie was excellent. Conclusion: By recording the surgeon's perspective of an endoscopic urological procedure, we were able to provide a comprehensive understanding of the surgical technique by assembling the endoscopic, fluoroscopic, and operative field views. The GoPro® camera proved to be an interesting tool to document surgical procedures without compromising outcomes and has great potential for educational purposes.
RESUMEN
ABSTRACT Purpose: High intra-renal pressures during flexible ureteroscopy have been associated with adverse renal tissue changes as well as pyelovenous backflow. Our objective was to investigate the effect of various intra-renal pressures on histologic changes and fluid extravasation during simulated ureteroscopy. Materials and Methods: Twenty-four juvenile pig kidneys with intact ureters were cannulated with an Olympus flexible ureteroscope with and without a ureteral access sheath and subjected to India ink-infused saline irrigation for 30 minutes at constant pressures ranging from sphygmomanometer settings of 50mm, 100mm and 200mmHg. Renal tissue samples were collected, processed and stained, and were evaluated by a blinded pathologist for depth of ink penetration into renal parenchyma as a percentage of total parenchymal thickness from urothelium to renal capsule. Results: The mean percentage of tissue penetration for kidneys with ink present in the cortical tubules at sphygmomanometer pressure settings of 50, 100, and 200mm Hg without a ureteral access sheath was 33.1, 31.0 and 99.3%, respectively and with ureteral access sheath was 0, 0 and 18.8%, respectively. Overall, kidneys with an access sheath demonstrated a smaller mean tissue penetration among all pressure compared to kidneys without a sheath (6.3% vs. 54.5%, p=0.0354). Of kidneys with sheath placement, 11% demonstrated any ink compared to 56% of kidneys without sheath placement. Conclusions: Pressurized endoscopic irrigation leads to significant extravasation of fluid into the renal parenchyma. Higher intra-renal pressures were associated with increased penetration of irrigant during ureteroscopy in an ex-vivo porcine model.
Asunto(s)
Animales , Uréter , Ureteroscopios , Presión , Porcinos , Ureteroscopía , Irrigación Terapéutica , RiñónRESUMEN
Objective: To report the outcomes of percutaneous nephrolithotomy (PCNL) in horseshoe kidneys (HSK) in 12 institutions worldwide and evaluate the impact of patient position during operation. Methods: We carried out a retrospective analysis of PCNL procedures performed between 2008 and 2018 in patients with HSK. Pre-, peri-, and postoperative data were collected, and a subgroup analysis was performed according to patient position. Success was defined as an absence of >4-mm fragments. Values of p < 0.05 were considered significant. Results: We analyzed 106 procedures. The transfusion, complication, and immediate success rates (ISRs) were 3.8%, 17.5%, and 54.7%, respectively. The final success rate (FSR) increased to 72.4% after a mean of 0.24 secondary procedures. Logistic regression showed that higher body mass index (BMI) and stone size were significantly associated with residual fragments ≥4 mm. Sixty-seven patients (63.2%) were treated in prone and 39 (36.8%) in supine position. The prone group had a significantly higher BMI than the supine group (30.1 vs 27.7, p = 0.024). The transfusion, complication, and ISRs between the prone and supine groups were 4.5% vs 2.6% (p = 0.99), 16.9% vs 18.4% (p = 0.99), and 52.5% vs 69.2% (p = 0.151), respectively. Surgical time was significantly longer in the prone group (126.5 vs 100 minutes, p = 0.04). Upper pole was the preferred access in 80.3% of the prone group and 43.6% of the supine group (p < 0.001). The prone group had significantly more Clavien 2 complications than the supine (p = 0.013). The FSR in the prone and supine groups increased to 66.1% and 82.1% after 0.26 and 0.21 secondary procedures, respectively. No complications higher than Clavien 3 occurred. Conclusion: PCNL in patients with HSK is safe and effective with a low complication rate. Higher BMI and stone size negatively impacted outcomes. Supine PCNL may be an option for treating kidney stones in patients with HSK.
Asunto(s)
Riñón Fusionado , Cálculos Renales , Nefrolitotomía Percutánea , Nefrostomía Percutánea , Riñón Fusionado/cirugía , Humanos , Cálculos Renales/cirugía , Nefrolitotomía Percutánea/efectos adversos , Nefrostomía Percutánea/efectos adversos , Posicionamiento del Paciente , Posición Prona , Estudios Retrospectivos , Posición Supina , Resultado del TratamientoRESUMEN
PURPOSE: To evaluate the impact of extensive surgery on urine profile, serum exams and stone composition of complicated IBD patients. METHODS: Patients with IBD and a history of total proctocolectomy (TPC) with fecal diversion (end ileostomy or ileal pouch anal anastomosis-IPAA) were selected. Only patients with at least one complete 24-h urine profile were included. A case-control study was performed selecting patients with kidney stone disease in a random way who had also at least on complete 24-h urine profile. Case and controls were matched for age, gender, and body mass index (BMI). Groups were compared to urine profile, serum exams and stone composition. RESULTS: Sixty-eight patients were enrolled in this study, 34 patients with IBD who underwent TPC and had diagnosis of kidney stones and 34 matched patients with only kidney stones. IBD patients had a significantly lower urine volume, urine citrate and urine sodium. Regarding serum exams, only serum bicarbonate was statistically significant lower. In both groups, calcium oxalate stone was the most common. CONCLUSION: Patients with IBD with TPC and kidney stones have a low urine volume and low urine citrate as main risk factors for kidney stone formation. As seen in the general population, calcium oxalate is the most common stone composition.
Asunto(s)
Enfermedades Inflamatorias del Intestino/orina , Cálculos Renales/química , Cálculos Renales/orina , Urolitiasis/orina , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Enfermedades Inflamatorias del Intestino/complicaciones , Cálculos Renales/complicaciones , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Urolitiasis/complicacionesRESUMEN
PURPOSE: High intra-renal pressures during flexible ureteroscopy have been associated with adverse renal tissue changes as well as pyelovenous backflow. Our objective was to investigate the effect of various intra-renal pressures on histologic changes and fluid extravasation during simulated ureteroscopy. MATERIALS AND METHODS: Twenty-four juvenile pig kidneys with intact ureters were cannulated with an Olympus flexible ureteroscope with and without a ureteral access sheath and subjected to India ink-infused saline irrigation for 30 minutes at constant pressures ranging from sphygmomanometer settings of 50mm, 100mm and 200mmHg. Renal tissue samples were collected, processed and stained, and were evaluated by a blinded pathologist for depth of ink penetration into renal parenchyma as a percentage of total parenchymal thickness from urothelium to renal capsule. RESULTS: The mean percentage of tissue penetration for kidneys with ink present in the cortical tubules at sphygmomanometer pressure settings of 50, 100, and 200mm Hg without a ureteral access sheath was 33.1, 31.0 and 99.3%, respectively and with ureteral access sheath was 0, 0 and 18.8%, respectively. Overall, kidneys with an access sheath demonstrated a smaller mean tissue penetration among all pressure compared to kidneys without a sheath (6.3% vs. 54.5%, p=0.0354). Of kidneys with sheath placement, 11% demonstrated any ink compared to 56% of kidneys without sheath placement. CONCLUSIONS: Pressurized endoscopic irrigation leads to significant extravasation of fluid into the renal parenchyma. Higher intra-renal pressures were associated with increased penetration of irrigant during ureteroscopy in an ex-vivo porcine model.
Asunto(s)
Uréter , Ureteroscopios , Animales , Riñón , Presión , Porcinos , Irrigación Terapéutica , UreteroscopíaRESUMEN
ABSTRACT Patients with staghorn renal stones are challenging cases, requiring careful preoperative evaluation and close follow-up to avoid stone recurrence. In this article we aim to discuss the main topics related to staghorn renal stones with focus on surgical approach. Most of staghorn renal stones are composed of struvite (magnesium ammonium phosphate) and are linked to urinary tract infection by urease-producing pathogens. Preoperative computed tomography scan and careful evaluation of all urine cultures made prior surgery are essential for a well-planning surgical approach and a right antibiotics choice. Gold standard surgical technique is the percutaneous nephrolithotomy (PCNL). In cases of impossible percutaneous renal access, anatrophic nephrolithotomy is an alternative. Shockwave lithotripsy and flexible ureteroscopy are useful tools to treat residual fragments that can be left after treatment of complete staghorn renal stone. PCNL can be performed in supine or prone position according to surgeon's experience. Tranexamic acid can be used to avoid bleeding. To check postoperative stone-free status, computed tomography is the most accurate imaging exam, but ultrasound combined to KUB is an option. Intra-operative high-resolution fluoroscopy and flexible nephroscopy have been described as an alternative for looking at residual fragments and save radiation exposure. The main goals of treatment are stone-free status, infection eradication, and recurrence prevention. Long-term or short-term antibiotic therapy is recommended and regular control imaging exams and urine culture should be done.
Asunto(s)
Humanos , Masculino , Femenino , Nefrostomía Percutánea , Cálculos Coraliformes/cirugía , Cálculos Coraliformes/diagnóstico por imagen , Riñón , Resultado del Tratamiento , UrólogosRESUMEN
Patients with staghorn renal stones are challenging cases, requiring careful preoperative evaluation and close follow-up to avoid stone recurrence. In this article we aim to discuss the main topics related to staghorn renal stones with focus on surgical approach. Most of staghorn renal stones are composed of struvite (magnesium ammonium phosphate) and are linked to urinary tract infection by urease-producing pathogens. Preoperative computed tomography scan and careful evaluation of all urine cultures made prior surgery are essential for a well-planning surgical approach and a right antibiotics choice. Gold standard surgical technique is the percutaneous nephrolithotomy (PCNL). In cases of impossible percutaneous renal access, anatrophic nephrolithotomy is an alternative. Shockwave lithotripsy and flexible ureteroscopy are useful tools to treat residual fragments that can be left after treatment of complete staghorn renal stone. PCNL can be performed in supine or prone position according to surgeon's experience. Tranexamic acid can be used to avoid bleeding. To check postoperative stone-free status, computed tomography is the most accurate imaging exam, but ultrasound combined to KUB is an option. Intra-operative high-resolution fluoroscopy and flexible nephroscopy have been described as an alternative for looking at residual fragments and save radiation exposure. The main goals of treatment are stone-free status, infection eradication, and recurrence prevention. Long-term or short-term antibiotic therapy is recommended and regular control imaging exams and urine culture should be done.
Asunto(s)
Nefrolitotomía Percutánea , Nefrostomía Percutánea , Cálculos Coraliformes , Femenino , Humanos , Riñón , Masculino , Cálculos Coraliformes/diagnóstico por imagen , Cálculos Coraliformes/cirugía , Resultado del Tratamiento , UrólogosRESUMEN
INTRODUCTION: Two automated irrigation systems have been released for use during endoscopic procedures such as ureteroscopy: the Cogentix RocaFlow® (CRF) and Thermedx FluidSmart® (TFS). Accurate pressure control using automated systems may help providers maintain irrigation pressures within a safe range while also providing clear visualization. Our objective was to directly compare these systems based on their pressure accuracy, pressure-flow relationships, and fluid heating capabilities in order to help providers better utilize the temperature and pressure settings of each system. MATERIALS AND METHODS: An in vitro ureteroscopy model was used for testing, consisting of a short semirigid ureteroscope (6/7, 5F, 31cm Wolf 425612) connected to a continuous digital pressure transducer (Meriam m1550). Each system pressure output and flow-rate, via 100mL beaker filling time, was measured using multiple trials at pressure settings between 30 and 300mmHg. Output fluid temperature was monitored using a digital thermometer (Omega DP25-TH). RESULTS: The pressure output of both systems exceeded the desired setting across the entire tested range, a difference of 15.7±2.4mmHg for the TFS compared to 5.2±1.5mmHg for the CRF (p < 0.0001). Related to this finding, the TFS also had slightly higher flow rates across all trials (7±2mL/min). Temperature testing revealed a similar maximum temperature of 34.0°C with both systems, however, the TFS peaked after only 8 minutes and started to plateau as early as 4-5 minutes into the test, while the CRF took over 18 minutes to reach a similar peak. CONCLUSIONS: Our in vitro ureteroscopy testing found that the CRF system had better pressure accuracy than the TFS system but with noticeably slower fluid heating capabilities. Each system provided steady irrigation at safe pressures within their expected operating parameters with small differences in performance that should not limit their ability to provide steady irrigation at safe pressures.
Asunto(s)
Irrigación Terapéutica , Ureteroscopía , Presión , Temperatura , UreteroscopiosRESUMEN
BACKGROUND: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. METHODS: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch® (Model A), 100% Silicone Rusch® (Model B) and X-Flow Coloplast® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. RESULTS: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. CONCLUSION: Precise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications.
RESUMEN
Introduction: Lower pole kidney stones have been associated with poor shock wave lithotripsy (SWL) outcomes because of its location. However, the real impact of collecting system anatomy on stone clearance after SWL is uncertain. There is a lack of prospective well-controlled studies to determine whether lower pole kidney stones have inferior outcomes than nonlower pole kidney stones when treated with SWL. Methods: We prospectively evaluated patients with a single kidney stone of 5-15 mm undergoing SWL from June 12 through January 19. All patients were subjected to computed tomography before and 3 months after the procedure. Demographic data (age, gender, and body mass index), stone features (stone size, stone area, stone density, and stone-skin distance-SSD), and collecting system anatomy (infundibular length and width, and infundibulopelvic angle) were recorded. Outcomes (fragmentation and stone clearance rates) were compared between lower pole and nonlower pole cases. Then, a multivariate analysis including all variables was performed to determinate which parameters significantly impact on SWL outcomes. Results: One hundred and twenty patients were included in the study. Mean stone size was 8.3 mm and mean stone density was 805 Hounsfield units. Overall stone fragmentation, success, and stone-free rates were 84.1%, 64.1%, and 34.1%, respectively. There were no significant differences in stone fragmentation (76.0% vs 71.4%; p = 0.624), success rate (57.6% vs 53.3%; p = 0.435), and stone-free rate (40.2% vs 35.7%; p = 0.422) in the lower vs nonlower pole groups, respectively. On multivariate analysis, only stone density (p < 0.001) and SSD (p = 0.006) significantly influenced fragmentation. Stone size (p = 0.029), stone density (p = 0.002), and SSD (p = 0.049) significantly influenced kidney stone clearance. Conclusions: Stone size, stone density, and SSD impact on SWL outcomes. Lower pole kidney stones have similar fragmentation and stone clearance compared with nonlower pole kidney stones.
Asunto(s)
Cálculos Renales/terapia , Riñón/anatomía & histología , Litotricia/métodos , Adolescente , Adulto , Anciano , Índice de Masa Corporal , Femenino , Estudios de Seguimiento , Humanos , Riñón/diagnóstico por imagen , Cálculos Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto JovenRESUMEN
PURPOSE: To critically review all literature concerning the cost-effectiveness of flexible ureteroscopy comparing single-use with reusable scopes. MATERIALS AND METHODS: A systematic online literature review was performed in PubMed, Embase and Google Scholar databases. All factors potentially affecting surgical costs or clinical outcomes were considered. Prospective assessments, case control and case series studies were included. RESULTS: 741 studies were found. Of those, 18 were duplicated and 77 were not related to urology procedures. Of the remaining 646 studies, 59 were considered of relevance and selected for further analysis. Stone free and complication rates were similar between single-use and reusable scopes. Operative time was in average 20% shorter with digital scopes, single-use or not. Reusable digital scopes seem to last longer than optic ones, though scope longevity is very variable worldwide. New scopes usually last four times more than refurbished ones and single-use ureterorenoscopes have good resilience throughout long cases. Longer scope longevity is achieved with Cidex and if a dedicated nurse takes care of the sterilization process. The main surgical factors that negatively impact device longevity are lower pole pathologies, large stone burden and non-use of a ureteral access sheath. We have built a comprehensive fi nancial costeffective decision model to fl exible ureteroscope acquisition. CONCLUSIONS: The cost-effectiveness of a fl exible ureteroscopy program is dependent of several aspects. We have developed a equation to allow a literature-based and adaptable decision model to every interested stakeholder. Disposable devices are already a reality and will progressively become the standard as manufacturing price falls.
Asunto(s)
Equipo Reutilizado/economía , Ureteroscopios/economía , Ureteroscopía/economía , Análisis Costo-Beneficio , Diseño de Equipo , Equipo Reutilizado/estadística & datos numéricos , Humanos , Tempo Operativo , Ureteroscopios/normas , Ureteroscopios/estadística & datos numéricos , Ureteroscopía/instrumentación , Ureteroscopía/estadística & datos numéricosRESUMEN
ABSTRACT Purpose to critically review all literature concerning the cost-effectiveness of flexible ureteroscopy comparing single-use with reusable scopes. Materials and Methods A systematic online literature review was performed in PubMed, Embase and Google Scholar databases. All factors potentially affecting surgical costs or clinical outcomes were considered. Prospective assessments, case control and case series studies were included. Results 741 studies were found. Of those, 18 were duplicated and 77 were not related to urology procedures. Of the remaining 646 studies, 59 were considered of relevance and selected for further analysis. Stone free and complication rates were similar between single-use and reusable scopes. Operative time was in average 20% shorter with digital scopes, single-use or not. Reusable digital scopes seem to last longer than optic ones, though scope longevity is very variable worldwide. New scopes usually last four times more than refurbished ones and single-use ureterorenoscopes have good resilience throughout long cases. Longer scope longevity is achieved with Cidex and if a dedicated nurse takes care of the sterilization process. The main surgical factors that negatively impact device longevity are lower pole pathologies, large stone burden and non-use of a ureteral access sheath. We have built a comprehensive financial cost-effective decision model to flexible ureteroscope acquisition. Conclusions The cost-effectiveness of a flexible ureteroscopy program is dependent of several aspects. We have developed a equation to allow a literature-based and adaptable decision model to every interested stakeholder. Disposable devices are already a reality and will progressively become the standard as manufacturing price falls.
Asunto(s)
Humanos , Equipo Reutilizado/economía , Ureteroscopía/economía , Ureteroscopios/economía , Análisis Costo-Beneficio , Equipo Reutilizado/estadística & datos numéricos , Ureteroscopía/instrumentación , Ureteroscopía/estadística & datos numéricos , Ureteroscopios/normas , Ureteroscopios/estadística & datos numéricos , Diseño de Equipo , Tempo OperativoRESUMEN
INTRODUCTION: The optimal patient positioning for percutaneous nephrolithotomy (PCNL) based on the complexity of stone burden is not yet defined. Thus, we aimed to evaluate the intraoperative parameters, effectiveness and complications of patients undergoing PCNL between the endoscopic-guided prone split-leg PCNL (ePSL) and the supine PCNL by stratifying patients according to Guy's stone score (GSS). MATERIALS AND METHODS: A retrospective chart review was conducted of patients undergoing PCNL at two high-volume tertiary referral centers. At one center, patients underwent PCNL using the ePSL technique, while at the second center, patients underwent PCNL in supine. Patient demographics and stone characteristics, operative details, complications and effectiveness were compared between groups. The impact of obesity was also investigated. RESULTS: Of 830 subjects, a total of 449 (54%) underwent PCNL in ePSL and 381 (46%) in supine. The ePSL group had a greater mean age and body mass index. No statistical differences were found in gender, serum chemistry and Charlson comorbidity index. After stratifying patients by GSS, the differences in baseline stone burden between PSL and supine lost significance and both groups could be compared. Complications were not statistically different between both groups. Univariate analysis demonstrated that multiple tracts and lower pole access were more prevalent in supine. In addition, for GSS1-3, ePSL was correlated with reduced operative time, radiation exposure, length of hospital stay and need for secondary procedure. Multivariate analysis correlated ePSL with lower radiation exposure and need for secondary procedures (p = 0.01). In comparison to the whole trial population, the same tendencies were appreciated for obese cohort. CONCLUSIONS: This is the first report focusing on the performance differences between ePSL and supine PCNL stratified by GSS. Both techniques are safe, with a low rate of complications. For GSS1-3, ePSL reduces radiation exposure and requires less need for both multiple access and secondary procedure.