1.
Injury ; 53(2): 732-738, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34865819

RESUMEN

BACKGROUND: Venous thromboembolic events (VTE) are well-known and serious complications following a trauma to the lower extremities. There is an ongoing debate on the benefit of low-molecular-weight heparin (LMWH) as prophylaxis following ankle fracture treatment. We examined the association between the incidence of VTE and the use of LMWH-prophylaxis following an ankle fracture, as well as factors affecting the risk of VTE. METHODS: In this retrospective cohort study, data on ankle fractures and fracture treatment from the Swedish Fracture Register was linked to data from the Swedish National Patient Register and the Swedish Prescribed Drug Register. Patients with VTE and patients who received LMWH prophylaxis were identified. The treating orthopedic departments were sent a questionnaire about their guidelines regarding the use of LMWH prophylaxis. RESULTS: 222 cases of diagnosed VTE were identified among 14,954 ankle fractures. Orthopedic departments with higher-than-average use of LMWH prophylaxis among non-operatively treated ankle fractures had a lower incidence of VTE (OR 0.60, CI 0.39-0.92). Among operatively treated patients, departments with a guideline for the routine use of LMWH prophylaxis also had lower incidence of VTE (OR 0.56, CI 0.37-0.86). A later onset of VTE was seen among patients prescribed LMWH prophylaxis, with a mean of 56 days to onset (CI 44-67), compared to 39 days (CI 33-45) in patients without prescribed prophylaxis. During the first two weeks following injury, there was only one case of VTE in patients with prescribed LMWH, compared to 39 cases of VTE among patients without prescribed prophylaxis. CONCLUSIONS: Routine use of LMWH in patients with operatively treated ankle fractures was associated with a lower incidence of VTE. A more frequent use of LMWH among patients with non-operatively treated ankle fractures were associated with a lower incidence of VTE. The onset occurred later among patients with LMWH-prophylaxis who still suffered a VTE.


Asunto(s)
Fracturas de Tobillo , Tromboembolia Venosa , Fracturas de Tobillo/epidemiología , Fracturas de Tobillo/cirugía , Anticoagulantes/uso terapéutico , Heparina de Bajo-Peso-Molecular/uso terapéutico , Humanos , Incidencia , Estudios Retrospectivos , Tromboembolia Venosa/epidemiología , Tromboembolia Venosa/etiología , Tromboembolia Venosa/prevención & control
2.
Injury ; 52(10): 2896-2902, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33485637

RESUMEN

OBJECTIVES: - We aimed to investigate how pre-bending affects the mechanical properties, specifically fatigue, of stainless-steel plates. METHODS: - 3.5mm LCP 10-hole plates were pre-bent in 1, 2 and 3 locations to the same overall degree and fatigue testing performed. Finite Element Analysis (FEA) was performed in Strand7 (version 2.4.6) to better understand the failure point of the plates in four-point bending. RESULTS: - Six different plate pre-bending conditions were tested for resistance to fatigue failure. Increasing the number of pre-bends improved the fatigue resistance with two pre-bends having a mean 509,304 cycles to failure and three pre-bends 491,378 cycles to failure. The region of highest stress and the point of fatigue failure were at the plate's minimum cross-sectional area, which was predicted by the FEA and confirmed with mechanical testing. For plates pre-bent in two locations, the fatigue failure always occurred in the screw hole not in between the positions of the two pre-bends. Non-linear FEA simulation confirmed that work hardening occurs around pre-bend locations, conferring increased fatigue resistance to the holes next to, or between, pre-bend locations. CONCLUSIONS: We found that contrary to orthopaedic folklore, pre-bending of plates is not detrimental to fatigue resistance of the stainless-steel plates we tested. Pre-bending plates in a single plane increased the fatigue properties of the 10-hole stainless-steel plate tested.


Asunto(s)
Fijación Interna de Fracturas , Ortopedia , Placas Óseas , Humanos , Ensayo de Materiales , Estrés Mecánico
3.
Eur J Trauma Emerg Surg ; 47(3): 803-809, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31740996

RESUMEN

BACKGROUND: The purpose of this study was to compare the cumulative incidence of postoperative periprosthetic fracture (PPF) in a cohort of femoral neck fracture (FNF) patients treated with two commonly used cemented stems: either a collarless, polished, tapered Exeter stem or the anatomic Lubinus SP2 stem. METHODS: In this retrospective multicenter cohort study of a consecutive series of patients, we included 2528 patients of age 60 years and above with an FNF who were treated with either hemiarthroplasty or total hip arthroplasty using either a polished tapered Exeter stem or an anatomic Lubinus SP2 stem. The incidence of PPF was assessed at a minimum of 2 years postoperatively. RESULTS: The incidence of PPF was assessed at a median follow-up of 47 months postoperatively. Thirty nine patients (1.5%) sustained a PPF at a median of 27 months (range 0-96 months) postoperatively. Two of the operatively treated fractures were Vancouver A (5%), 7 were Vancouver B1 (18%), 10 were Vancouver B2 (26%), 7 were Vancouver B3 (18%), and 13 were Vancouver C (32%). The cumulative incidence of PPF was 2.3% in the Exeter group compared with 0.7% in the SP2 group (p < 0.001). The HR was 5.4 (95% CI 2.4-12.5, p < 0.001), using the SP2 group as the denominator. CONCLUSIONS: The Exeter stem was associated with a higher risk for PPF than the Lubinus SP2 stem. We suggest that the tapered Exeter stem should be used with caution in the treatment of FNF. TRIAL REGISTRATION: The study was registered at clinicaltrials.gov (identifier: NCT03326271).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas de Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Cohortes , Fracturas del Fémur/cirugía , Fracturas de Cadera/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Persona de Mediana Edad , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos
4.
Artículo en Inglés | MEDLINE | ID: mdl-32670600

RESUMEN

INTRODUCTION: The literature regarding undisplaced femoral neck fractures (FNF) is sparse. The aim of this prospective feasibility study is to compare the clinical outcome after undisplaced FNF treated with internal fixation (IF) and displaced FNF treated with hip arthroplasty. We hypothesized that hip arthroplasty would give a lower incidence of reoperations. METHODS: A total of 235 patients were included with a median age of 84 years (range 65-99). A consecutive series of 65 patients with undisplaced FNF were treated with IF, and 170 patients with displaced FNF were treated with either a total hip arthroplasty or a hemiarthroplasty. Follow-up interviews were conducted at 1 year using the Harris Hip Score (HHS), WOMAC, and pain numeric rating scale (PNRS). The minimum follow-up time was 22 months. There was no difference in baseline data between the groups. RESULTS: Nineteen (8%) hips required reoperation at least once at a mean of 6 months (range 0-35). The rate of reoperation was higher in the IF group compared to the hip arthroplasty group (13.8% vs. 5.9%, 95% CI 0.9-6.4). The overall 1-year and 2-year mortality was 28% and 40%, respectively, with no difference between the groups. The most common reasons for reoperations in the IF group were non-union and avascular necrosis, and 6 patients were treated with hip or excision arthroplasty. In the arthroplasty group, the most common indications were deep infection and dislocation. We did not find any differences between the groups in terms of HHS, WOMAC, and PNRS. CONCLUSIONS: In this feasibility study, we found no differences in patient-reported outcomes between the groups although IF required a higher rate of reoperations. Further randomized trials are needed to establish the optimal treatment of undisplaced FNF in the elderly. TRIAL REGISTRATION: ClinicalTrial.org, NCT03392285. Retrospectively registered on 5 February 2018.

5.
J Orthop Surg Res ; 15(1): 177, 2020 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-32408885

RESUMEN

BACKGROUND: What is the right surface for an implant to achieve biological fixation? Surface technologies can play important roles in encouraging interactions between the implant surface and the host bone to achieve osseointegration. Preclinical animal models provide important insight into in vivo performance related to bone ongrowth and implant fixation. METHODS: A large animal model was used to compare the in vivo response of HA and plasma-sprayed titanium coatings in a well-reported adult ovine model to evaluate bone ongrowth in terms of mechanical properties in cortical sites, and histology and histomorphometry in cortical and cancellous sites at 4 and 12 weeks. RESULTS: Titanium plasma-sprayed surfaces outperformed the HA-coated samples in push-out testing in cortical sites while both surfaces supported new bone ongrowth and remodeling in cortical and cancellous sites. CONCLUSIONS: While both HA and Ti plasma provided an osteoconductive surface for bone ongrowth, the Ti plasma provided a more robust bone-implant interface that ideally would be required for load transfer and implant stability in the longer term.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Placas Óseas , Hueso Esponjoso/fisiología , Hueso Esponjoso/cirugía , Hueso Cortical/fisiología , Hueso Cortical/cirugía , Animales , Hueso Esponjoso/citología , Hueso Cortical/citología , Resistencia al Corte/fisiología , Ovinos , Titanio
6.
Spine J ; 19(11): 1885-1898, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31255790

RESUMEN

BACKGROUND CONTEXT: The potential for osseointegration to provide biological fixation for implants may be related to anatomical site and loading conditions. PURPOSE: To evaluate the influence of anatomical site on osseointegration of 3D-printed implants. STUDY DESIGN: A comparative preclinical study was performed evaluating bone ingrowth in cortical and cancellous sites in long bones as well as lumbar interbody fusion with posterior pedicle screw stabilization using the same 3D-printed titanium alloy design. METHODS: 3D-printed dowels were implanted in cortical bone and cancellous bone in adult sheep and evaluated at 4 and 12 weeks for bone ingrowth using radiography, mechanical testing, and histology/histomorphometry. In addition, a single-level lumbar interbody fusion using cages based on the same 3D-printed design was performed. The aperture was filled with autograft or ovine allograft processed with supercritical carbon dioxide. Interbody fusions were assessed at 12 weeks via radiography, mechanical testing, and histology/histomorphometry. RESULTS: Bone ingrowth in long bone cortical and cancellous sites did not translate directly to interbody fusion cages. While bone ingrowth was robust and improved with time in cortical sites with a line-to-line implantation condition, the same response was not found in cancellous sites even when the implants were placed in a press fit manner. Osseointegration into the porous walls with 3D porous interbody cages was similar to the cancellous implantation sites rather than the cortical sites. The porous domains of the 3D-printed device, in general, were filled with fibrovascular tissue while some bone integration into the porous cages was found at 12 weeks when fusion within the aperture was present. CONCLUSION: Anatomical site, surgical preparation, biomechanical loading, and graft material play an important role in in vivo response. Bone ingrowth in long bone cortical and cancellous sites does not translate directly to interbody fusions.


Asunto(s)
Hueso Esponjoso/cirugía , Hueso Cortical/cirugía , Vértebras Lumbares/cirugía , Oseointegración/fisiología , Impresión Tridimensional , Prótesis e Implantes , Animales , Fenómenos Biomecánicos , Hueso Esponjoso/fisiología , Hueso Cortical/fisiología , Vértebras Lumbares/fisiología , Porosidad , Diseño de Prótesis , Ovinos , Fusión Vertebral/instrumentación , Titanio
7.
BMC Musculoskelet Disord ; 19(1): 441, 2018 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-30545314

RESUMEN

BACKGROUND: The ankle fracture is one of the most common fractures, increasing in an ageing population, but not generally seen as an osteoporotic fracture. The aim of this study was to examine the relationship between different AO/OTA classes of ankle fractures, age, sex and type of trauma. METHODS: Ankle fractures, treated at any of the hospitals in Norrbotten County in Sweden between 2009 and 2013, were retrospectively identified and classified according to the AO/OTA-classification system. Information about the trauma mechanism was also obtained. RESULTS: In Norrbotten County, 1756 ankle fractures in 1735 patients aged 20 years or older were identified. This gave an incidence in the county of 179 per 100,000 person-years. Of these patients, 34.6% were 65 years or older, 58.4% were women and 68.2% of the trauma leading to a fracture was defined as low-energy. In 1.5% of the cases the fractures were open. Incidences of type B fractures increased substantially with age, from 62 (95% CI 50-77) at 30-39 years of age to 158 (95% CI 131-190) in patients older than 80 years of age per 100,000 person-years. Type B fractures showed a slightly higher proportion of low-energy trauma while type C showed a lower mean age and proportion of women. CONCLUSIONS: This study shows an incidence of 179 adult ankle fractures annually per 100,000 persons. More than two thirds of the fractures were caused by a low-energy trauma and ankle fractures are more frequent among females. Females generally have an increased incidence during their life, mainly between the ages of 30 and 60. This is in contrast to men who have more of an even distribution throughout their life. Classification according to AO/OTA reveals some heterogeneity among the classes of ankle fractures in age and gender as well as the energy involved in the trauma.


Asunto(s)
Fracturas de Tobillo/clasificación , Fracturas de Tobillo/epidemiología , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Fracturas de Tobillo/etiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/clasificación , Fracturas Osteoporóticas/epidemiología , Estudios Retrospectivos , Distribución por Sexo , Suecia/epidemiología , Adulto Joven
8.
BMC Musculoskelet Disord ; 18(1): 278, 2017 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-28659134

RESUMEN

BACKGROUND: The Swedish Fracture Register (SFR) currently contains information on more than 190,000 fractures. Patient Reported Outcome Measures (PROMs) are used for monitoring functional results after fracture treatment. One weakness, as in many surveys, is a low response rate. The aim of the current study was to examine if non-responders of a survey in the SFR differ in PROMs scores, how age and gender influence the response rate and reasons for not responding. METHODS: Patients with fractures of radius, ulna or humerus between June and August 2013 and registered in the SFR were included in the study. The non-responders to both the pre-injury and the 1-year survey were contacted by phone and reminded to reply. A comparison of the results of both EQ-5D and Short Musculoskeletal Function Assessment (SMFA) could be made between the responders after a phone reminder and the initial responders. The response rate for the register as a whole was extracted in order to identify how age and gender affect the response rate. RESULTS: Three hundred seventeen of the patients included in the study responded initially. After phone reminder another 94 patients answered the pre-injury survey. Two hundred sixty eight responded initially to the 1-year follow-up survey and 42 after phone reminder. No significant difference was identified in the score of the pre-injury survey between initial responders and responders after phone reminder neither in the EQ-5D nor in the Short Musculoskeletal Function Assessment (SMFA). Regarding the 1-year survey, responders after a phone reminder reported a significantly better outcome in crude data of SMFA score. This difference disappeared after controlling for confounding factors through case control matching. The highest response rate to PROMs in the SFR was among females in the age range 60-69 years. CONCLUSION: This study indicates that both in the preinjury survey as well as in the 1-year survey the non-responders in the SFR report similar function compared to the initial responders. Age and gender of patients affect the response rate of the survey which needs to be taken into consideration in analysis of data from the SFR.


Asunto(s)
Fracturas Óseas/epidemiología , Medición de Resultados Informados por el Paciente , Sistema de Registros/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios , Suecia/epidemiología
9.
Acta Orthop ; 88(4): 402-406, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28426259

RESUMEN

Background and purpose - Displaced femoral neck fractures (FNFs) are associated with high rates of mortality during the first postoperative year. The Sernbo score (based on age, habitat, mobility, and mental state) can be used to stratify patients into groups with different 1-year mortality. We assessed this predictive ability in patients with a displaced FNF treated with a hemiarthroplasty or a total hip arthroplasty. Patients and methods - 292 patients (median age 83 (65-99) years, 68% female) with a displaced FNF were included in this prospective cohort study. To predict 1-year mortality, we used a multivariate logistic regression analysis including comorbidities and perioperative management. A receiver operating characteristic (ROC) analysis was used to evaluate the predictive ability of the Sernbo score, which was subsequently divided in a new manner into a low, intermediate, or high risk of death during the first year. Results - At 1-year follow-up, the overall mortality rate was 24%, and in Sernbo's low-, intermediate-, and high-risk groups it was 5%, 22%, and 51%, respectively. The Sernbo score was the only statistically significant predictor of 1-year mortality: odds ratio for the intermediate-risk group was 4.2 (95% Cl: 1.5-12) and for the high-risk group it was 15 (95% CI: 5-40). The ROC analysis showed a fair predictive ability of the Sernbo score, with an area under the curve (AUC) of 0.79 (95% CI: 0.73-0.83). Using a cutoff of less than 11 points on the score gave a sensitivity of 61% and a specificity of 83%. Interpretation - The Sernbo score identifies patients who are at high risk of dying in the first postoperative year. This scoring system could be used to better tailor perioperative care and treatment in patients with displaced FNF.


Asunto(s)
Artroplastia de Reemplazo de Cadera/mortalidad , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/mortalidad , Actividades Cotidianas , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Fracturas del Cuello Femoral/mortalidad , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo
10.
Injury ; 47(11): 2579-2583, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27645617

RESUMEN

INTRODUCTION: Since 2011 the Swedish Fracture Register (SFR) has collected information on fracture epidemiology, treatment and outcome. More than 112 000 fractures, including 11 600 ankle fractures, have been registered so far. The accuracy of the classification is crucial when using the register in future research and quality improvement of care. In this study we examine the degree of accuracy of the AO/OTA-classification in which ankle fractures are recorded in the SFR. METHODS: 152 randomly selected ankle fractures registered in the SFR were classified independently by a reference group of three orthopedic surgeons on two occasions. The agreed AO/OTA-classification of the reference group was regarded as the gold standard classification for each case. The originally recorded classification in the SFR was subsequently compared with the classification of the reference group and accuracy calculated. RESULTS: The agreement between the classification in the SFR and of the reference group was 74%, corresponding to kappa 0.67, 95% CI (0.58-0.76) for AO/OTA group level. An agreement of 88% equivalent to kappa 0.77, 95% CI (0.67-0.87) was noted for AO/OTA type level. The agreement corresponds to substantial according to Landis and Koch. The kappa value of inter- and intraobserver agreement ranged from 0.67 to 0.93. CONCLUSIONS: The study results show substantial agreement between classifications made in the SFR and gold standard classification. The finding is equivalent to or higher than in previous studies. Consequently, we conclude that classifications of ankle fractures in the SFR are accurate and valid.


Asunto(s)
Fracturas de Tobillo/clasificación , Adhesión a Directriz , Radiografía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/epidemiología , Femenino , Humanos , Masculino , Sistemas de Registros Médicos Computarizados , Persona de Mediana Edad , Variaciones Dependientes del Observador , Distribución Aleatoria , Sistema de Registros , Reproducibilidad de los Resultados , Suecia/epidemiología , Adulto Joven
SELECCIÓN DE REFERENCIAS