Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 81
2.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Article En | MEDLINE | ID: mdl-38418058

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Cardiac Catheterization/adverse effects , Treatment Outcome , Recovery of Function , Time Factors , Severity of Illness Index , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Registries
4.
JACC Cardiovasc Interv ; 14(16): 1815-1826, 2021 08 23.
Article En | MEDLINE | ID: mdl-34412799

OBJECTIVES: The aim of this study was to evaluate the impact of echocardiographic guidance on the safety and efficacy of left atrial appendage closure (LAAC). BACKGROUND: Expert consensus documents recommend intraprocedural imaging by means of either transesophageal echocardiography or intracardiac echocardiography to guide LAAC. However, no evidence exists that intraprocedural echocardiographic guidance in addition to fluoroscopy improves the safety and efficacy of LAAC. METHODS: Consecutive LAAC procedures performed at a high-volume center between January 2009 and October 2020 were stratified on the basis of intraprocedural imaging modalities, including fluoroscopic guidance (FG) only or intraprocedural echocardiographic guidance (EG) in addition to fluoroscopy. The primary safety endpoint was the composite of procedure-related complications occurring within 7 days after the procedure. Technical success at 7 days and at follow-up were secondary endpoints. RESULTS: Among 811 LAAC procedures, 549 (67.7%) and 262 (32.3%) were assigned to the FG and EG groups, respectively. After adjusting for confounders, EG remained associated with a lower rate of the primary safety endpoint (3.4% vs 9.1%; P = 0.004; adjusted odds ratio [OR]: 0.31; 95% CI: 0.11-0.90; P = 0.030). Technical success trended higher at 7 days (92.1% vs 87.2%; P = 0.065; adjusted OR: 1.68; 95% CI: 0.95-3.01; P = 0.079) and was significantly improved with EG compared with FG (87.6% vs 79.9%; P = 0.018; OR: 4.06; 95% CI: 1.60-10.27; P = 0.003) after a median follow-up period of 4.9 months (interquartile range: 3.4 months-6.2 months). CONCLUSIONS: In a large cohort of consecutive LAACs, the use of intraprocedural echocardiography to guide intervention in addition to standard fluoroscopy was associated with lower risks for procedural complications and higher mid-term technical success rates.


Atrial Appendage , Atrial Fibrillation , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/adverse effects , Echocardiography , Echocardiography, Transesophageal , Humans , Treatment Outcome
5.
Circulation ; 144(15): 1196-1211, 2021 10 12.
Article En | MEDLINE | ID: mdl-34455849

BACKGROUND: The optimal duration of antiplatelet therapy (APT) in patients at high bleeding risk with or without oral anticoagulation (OAC) after coronary stenting remains unclear. METHODS: In the investigator-initiated, randomize, open-label MASTER DAPT trial (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Standard DAPT Regimen), 4579 patients at high bleeding risk were randomized after 1-month dual APT to abbreviated or nonabbreviated APT strategies. Randomization was stratified by concomitant OAC indication. In this subgroup analysis, we report outcomes of populations with or without an OAC indication. In the population with an OAC indication, patients changed immediately to single APT for 5 months (abbreviated regimen) or continued ≥2 months of dual APT and single APT thereafter (nonabbreviated regimen). Patients without an OAC indication changed to single APT for 11 months (abbreviated regimen) or continued ≥5 months of dual APT and single APT thereafter (nonabbreviated regimen). Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes (composite of all-cause death, myocardial infarction, stroke, and Bleeding Academic Research Consortium 3 or 5 bleeding events); major adverse cardiac and cerebral events (all-cause death, myocardial infarction, and stroke); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: Net adverse clinical outcomes or major adverse cardiac and cerebral events did not differ with abbreviated versus nonabbreviated APT regimens in patients with OAC indication (n=1666; hazard ratio [HR], 0.83 [95% CI, 0.60-1.15]; and HR, 0.88 [95% CI, 0.60-1.30], respectively) or without OAC indication (n=2913; HR, 1.01 [95% CI, 0.77-1.33]; or HR, 1.06 [95% CI, 0.79-1.44]; Pinteraction=0.35 and 0.45, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding did not significantly differ in patients with OAC indication (HR, 0.83 [95% CI, 0.62-1.12]) but was lower with abbreviated APT in patients without OAC indication (HR, 0.55 [95% CI, 0.41-0.74]; Pinteraction=0.057). The difference in bleeding in patients without OAC indication was driven mainly by a reduction in Bleeding Academic Research Consortium 2 bleedings (HR, 0.48 [95% CI, 0.33-0.69]; Pinteraction=0.021). CONCLUSIONS: Rates of net adverse clinical outcomes and major adverse cardiac and cerebral events did not differ with abbreviated APT in patients with high bleeding risk with or without an OAC indication and resulted in lower bleeding rates in patients without an OAC indication. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03023020.


Anticoagulants/therapeutic use , Hemorrhage/drug therapy , Platelet Aggregation Inhibitors/therapeutic use , Stents/standards , Administration, Oral , Aged , Anticoagulants/pharmacology , Female , Humans , Male , Platelet Aggregation Inhibitors/pharmacology , Risk Factors
6.
N Engl J Med ; 385(18): 1643-1655, 2021 10 28.
Article En | MEDLINE | ID: mdl-34449185

BACKGROUND: The appropriate duration of dual antiplatelet therapy in patients at high risk for bleeding after the implantation of a drug-eluting coronary stent remains unclear. METHODS: One month after they had undergone implantation of a biodegradable-polymer sirolimus-eluting coronary stent, we randomly assigned patients at high bleeding risk to discontinue dual antiplatelet therapy immediately (abbreviated therapy) or to continue it for at least 2 additional months (standard therapy). The three ranked primary outcomes were net adverse clinical events (a composite of death from any cause, myocardial infarction, stroke, or major bleeding), major adverse cardiac or cerebral events (a composite of death from any cause, myocardial infarction, or stroke), and major or clinically relevant nonmajor bleeding; cumulative incidences were assessed at 335 days. The first two outcomes were assessed for noninferiority in the per-protocol population, and the third outcome for superiority in the intention-to-treat population. RESULTS: Among the 4434 patients in the per-protocol population, net adverse clinical events occurred in 165 patients (7.5%) in the abbreviated-therapy group and in 172 (7.7%) in the standard-therapy group (difference, -0.23 percentage points; 95% confidence interval [CI], -1.80 to 1.33; P<0.001 for noninferiority). A total of 133 patients (6.1%) in the abbreviated-therapy group and 132 patients (5.9%) in the standard-therapy group had a major adverse cardiac or cerebral event (difference, 0.11 percentage points; 95% CI, -1.29 to 1.51; P = 0.001 for noninferiority). Among the 4579 patients in the intention-to-treat population, major or clinically relevant nonmajor bleeding occurred in 148 patients (6.5%) in the abbreviated-therapy group and in 211 (9.4%) in the standard-therapy group (difference, -2.82 percentage points; 95% CI, -4.40 to -1.24; P<0.001 for superiority). CONCLUSIONS: One month of dual antiplatelet therapy was noninferior to the continuation of therapy for at least 2 additional months with regard to the occurrence of net adverse clinical events and major adverse cardiac or cerebral events; abbreviated therapy also resulted in a lower incidence of major or clinically relevant nonmajor bleeding. (Funded by Terumo; MASTER DAPT ClinicalTrials.gov number, NCT03023020.).


Acute Coronary Syndrome/therapy , Hemorrhage/chemically induced , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors/administration & dosage , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/mortality , Aged , Cardiovascular Diseases/mortality , Drug Therapy, Combination , Drug-Eluting Stents , Female , Humans , Kaplan-Meier Estimate , Male , Myocardial Infarction/etiology , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/therapeutic use , Risk Factors , Stroke/etiology , Thrombosis/prevention & control
7.
EuroIntervention ; 16(8): 634-644, 2020 Oct 23.
Article En | MEDLINE | ID: mdl-31498113

AIMS: The aim of this study was to evaluate the impact of a novel antiplatelet regimen in patients with increasing total stent length (TSL). METHODS AND RESULTS: This is a post hoc analysis of the GLOBAL LEADERS trial, a prospective, multicentre, open-label, randomised trial, investigating the impact of the experimental strategy (one-month dual antiplatelet therapy [DAPT] followed by 23-month ticagrelor monotherapy) versus the reference regimen (12-month DAPT followed by 12-month aspirin monotherapy) in patients with a Biolimus A9-eluting stent (BES). The primary endpoint was the composite of all-cause death and new Q-wave myocardial infarction (MI), and the secondary endpoint was Bleeding Academic Research Consortium (BARC) type 3 or 5 bleeding at two years. To investigate the association between total stent length and outcomes, groups were compared in quartiles according to TSL; the fourth quartile group was at significantly higher ischaemic risk at two years. In that stratum (TSL ≥46 mm), the experimental strategy significantly reduced the risk of the primary endpoint (hazard ratio [HR] 0.67, 95% confidence interval [CI]: 0.49-0.90; pinteraction=0.043), while demonstrating a similar risk of BARC type 3 or 5 bleeding (HR 0.99, 95% CI: 0.66-1.49; pinteraction=0.975). CONCLUSIONS: Ticagrelor monotherapy could potentially balance ischaemic and bleeding risks, thereby achieving a net clinical benefit in patients with a TSL ≥46 mm with a BES.


Drug-Eluting Stents , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Ticagrelor , Drug Therapy, Combination , Humans , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Stents , Ticagrelor/therapeutic use , Treatment Outcome
8.
Am. j. cardiol ; 124(12): 1833-1840, dez., 2019. tab., graf.
Article En | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1050065

Abstract: Q-wave myocardial infarction (QWMI) comprises 2 entities. First, a clinically evident MI, which can occur spontaneously or be related to a coronary procedure. Second, silent MI which is incidentally detected on serial electrocardiographic (ECG) assessment. The prevalence of silent MI after percutaneous coronary intervention (PCI) in the drug-eluting stent era has not been fully investigated. The GLOBAL LEADERS is an all-comers multicenter trial which randomized 15,991 patients who underwent PCI to 2 antiplatelet treatment strategies. The primary end point was a composite of all-cause death or nonfatal new QWMI at 2-years follow-up. ECGs were collected at discharge, 3-month and 2-year visits, and analyzed by an independent ECG core laboratory following the Minnesota code. All new QWMI were further reviewed by a blinded independent cardiologist to identify a potential clinical correlate by reviewing clinical information. Of 15,968 participants, ECG information was complete in 14,829 (92.9%) at 2 years. A new QWMI was confirmed in 186 (1.16%) patients. Transient new Q-waves were observed in 28.5% (53 of 186) of them during the follow-up. The majority of new QWMI (78%, 146 of 186) were classified as silent MI due to the absence of a clinical correlate. Silent MI accounted for 22.1% (146 of 660) of all MI events. The prevalence of silent MI did not differ significantly between treatment strategies (experimental vs reference: 0.88% vs 0.98%, p = 0.5027). In conclusion, we document the prevalence of silent MI in an all-comers population undergoing PCI in this large-scale randomized trial. (AU)


Stents , Percutaneous Coronary Intervention , Myocardial Infarction
9.
Am J Cardiol ; 124(12): 1833-1840, 2019 12 15.
Article En | MEDLINE | ID: mdl-31648781

Q-wave myocardial infarction (QWMI) comprises 2 entities. First, a clinically evident MI, which can occur spontaneously or be related to a coronary procedure. Second, silent MI which is incidentally detected on serial electrocardiographic (ECG) assessment. The prevalence of silent MI after percutaneous coronary intervention (PCI) in the drug-eluting stent era has not been fully investigated. The GLOBAL LEADERS is an all-comers multicenter trial which randomized 15,991 patients who underwent PCI to 2 antiplatelet treatment strategies. The primary end point was a composite of all-cause death or nonfatal new QWMI at 2-years follow-up. ECGs were collected at discharge, 3-month and 2-year visits, and analyzed by an independent ECG core laboratory following the Minnesota code. All new QWMI were further reviewed by a blinded independent cardiologist to identify a potential clinical correlate by reviewing clinical information. Of 15,968 participants, ECG information was complete in 14,829 (92.9%) at 2 years. A new QWMI was confirmed in 186 (1.16%) patients. Transient new Q-waves were observed in 28.5% (53 of 186) of them during the follow-up. The majority of new QWMI (78%, 146 of 186) were classified as silent MI due to the absence of a clinical correlate. Silent MI accounted for 22.1% (146 of 660) of all MI events. The prevalence of silent MI did not differ significantly between treatment strategies (experimental vs reference: 0.88% vs 0.98%, p = 0.5027). In conclusion, we document the prevalence of silent MI in an all-comers population undergoing PCI in this large-scale randomized trial.


Aspirin/therapeutic use , Asymptomatic Diseases/mortality , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/methods , Ticagrelor/therapeutic use , Aged , Analysis of Variance , Coronary Angiography/methods , Drug Therapy, Combination , Drug-Eluting Stents , Electrocardiography/methods , Female , Humans , Internationality , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Percutaneous Coronary Intervention/mortality , Prognosis , Prospective Studies , Risk Assessment , Statistics, Nonparametric , Survival Analysis , Treatment Outcome
10.
JACC Cardiovasc Interv ; 12(15): 1438-1447, 2019 08 12.
Article En | MEDLINE | ID: mdl-31395213

OBJECTIVES: To evaluate the long-term (≥2 years) outcomes following transcatheter tricuspid valve repair (TTVr) with the FORMA Transcatheter Tricuspid Valve Repair System (Edwards Lifesciences, Irvine, California). BACKGROUND: Scarce data exist on long-term outcomes following TTVr. METHODS: This multicenter experience included patients with severe tricuspid regurgitation (TR) who underwent TTVr with the FORMA system at 4 centers under a compassionate clinical use program. Data were collected at baseline, 30 days, and 1 year, and yearly thereafter. RESULTS: Nineteen patients (76 ± 9 years of age, 74% women, mean EuroSCORE II [European System for Cardiac Operative Risk Evaluation] 9.2 ± 5.6%) with functional TR were included. Procedural success was achieved in 17 (89%) patients and there were no cases of 30-day mortality. At a median follow-up of 32 (interquartile range: 24 to 36) months, 4 (24%) patients had died (3 from terminal heart failure, 1 from sepsis) and 3 (18%) patients required rehospitalization for heart failure. There was 1 device-related thrombosis and 1 pulmonary embolism, both in the setting of subtherapeutic oral anticoagulation. Less than severe TR was observed at echocardiography in 67% of patients at the 2- to 3-year follow-up. Among 15 successfully implanted patients with at least 24-month follow-up, significant improvements in New York Heart Association functional class (p < 0.001), 6-min walk test (+54 m; p = 0.016) and Kansas City Cardiomyopathy Questionnaire score (+16 points; p = 0.016) were observed, compared with baseline. CONCLUSIONS: TTVr using the FORMA system showed favorable long-term safety profile in high-surgical-risk patients, with sustained functional improvement and acceptable TR reduction up to 3 years.


Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Hemodynamics , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Aged , Aged, 80 and over , Canada , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Compassionate Use Trials , Europe , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Recovery of Function , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/physiopathology
11.
JACC Cardiovasc Interv ; 12(17): 1665-1675, 2019 09 09.
Article En | MEDLINE | ID: mdl-31422088

OBJECTIVES: The aim of this study was to compare the efficacy and safety of a thin-strut, biodegradable-polymer everolimus-eluting stent (BP-EES) (Synergy, Boston Scientific, Marlborough, Massachusetts) and a thin-strut, durable-polymer everolimus-eluting stent (DP-EES) (XIENCE, Abbott Vascular, Abbott Park, Illinois) in an all-comers population. BACKGROUND: BP-EES have been shown to be noninferior to DP-EES in randomized trials in patients at low to moderate risk. METHODS: Among 7,042 consecutive patients who underwent percutaneous coronary intervention between December 2012 and December 2016, 3,870 patients were exclusively treated with BP-EES (n = 1,343) or with DP-EES (n = 2,527). After propensity score matching, the final study population consisted of 1,041 matched patients. The primary endpoint was the device-oriented composite endpoint (cardiac death, target vessel myocardial infarction, and target lesion revascularization) at 12 months. RESULTS: The device-oriented composite endpoint did not differ between the 2 groups (7.8% with BP-EES vs. 7.1% with DP-EES; hazard ratio: 1.12; 95% confidence interval: 0.81 to 1.53; p = 0.49). There were no differences in rates of cardiac death (3.0% vs. 3.0%; p = 1.00), target vessel myocardial infarction (3.6% vs. 3.1%; p = 0.53), and target lesion revascularization (3.0% vs. 2.5%; p = 0.41). The rate of acute stent thrombosis was significantly higher in the BP-EES group compared with the DP-EES group (1.2% vs. 0.3%; hazard ratio: 4.00; 95% confidence interval: 1.13 to 14.19; p = 0.032). At 12 months, the frequency of definite stent thrombosis did not differ (1.5% vs. 0.9%; hazard ratio: 1.67; 95% confidence interval: 0.73 to 3.82; p = 0.22). CONCLUSIONS: In this consecutively enrolled percutaneous coronary intervention population reflecting routine clinical practice, no difference in the device-oriented composite endpoint between BP-EES and DP-EES was observed throughout 12 months. There was a higher rate of acute stent thrombosis with the BP-EES, a difference that disappeared at 1 year. (CARDIOBASE Bern PCI Registry; NCT02241291).


Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Polymers/chemistry , Aged , Aged, 80 and over , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Switzerland , Time Factors , Treatment Outcome
12.
JACC Cardiovasc Interv ; 12(14): 1356-1365, 2019 07 22.
Article En | MEDLINE | ID: mdl-31129091

OBJECTIVES: The aim of this study was to investigate the technical success and efficacy of mitral valve edge-to-edge repair using extended clip arms. BACKGROUND: A new iteration of the MitraClip system, the MitraClip XTR, was introduced in 2018 with the aim of addressing technical limitations observed with previous versions. METHODS: Patients having received at least 1 new implant for the treatment of symptomatic mitral regurgitation (MR) were eligible for this study. RESULTS: Among the 107 patients (mean age 76 ± 9 years, 69% men) included in this study, the etiology of MR was balanced, with one-half (n = 53 [50%]) classified as secondary and the remaining 54 patients having either primary (n = 40 [37%]) or mixed (n = 14 [13%]) disease. The mean number of devices implanted was 1.5 ± 0.6. Multiple device implantation was required in 46 patients (43%). Single-leaflet device attachment occurred in 4 patients and leaflet injury in 2 additional patients, requiring surgical conversion in 4 patients. Among the 102 patients discharged alive without mitral valve surgery, 95 (93%) had MR ≤2+ and 79 (77%) had MR ≤1+. The mean transmitral gradient increased from 1.9 ± 1.0 mm Hg at baseline to 3.5 ± 1.8 mm Hg at discharge (p < 0.001). CONCLUSIONS: Technical success with the new mitral valve repair system with extended clip arm was achieved in 93% of the patients. MR ≤2+ was obtained in 95 patients (93%) and MR ≤1+ in 79 (77%). The main reasons for procedural failure were acute single-leaflet device attachment associated with leaflet damage or isolated leaflet injury and often required surgical correction.


Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Female , Germany , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Prosthesis Design , Recovery of Function , Risk Factors , Switzerland , Time Factors , Treatment Outcome
13.
JACC Cardiovasc Interv ; 12(9): 820-830, 2019 05 13.
Article En | MEDLINE | ID: mdl-30981574

OBJECTIVES: This study sought to validate European Society of Cardiology guideline-endorsed high-risk features of stent-related recurrent ischemic events for the prediction of ischemic and bleeding outcomes including a stratification according to the PRECISE-DAPT score estimated bleeding risk. BACKGROUND: The 2017 European Society of Cardiology-focused update on dual-antiplatelet therapy endorsed high-risk features of stent-related recurrent ischemic events. Because patients with high ischemic risk also have an increased bleeding risk, appropriate risk stratification for ischemic and bleeding events is crucial. METHODS: Between January 2009 and December 2015, a total of 10,236 consecutive patients undergoing clinically indicated percutaneous coronary intervention were prospectively included in the Bern PCI Registry. Guideline-endorsed high-risk features were retrospectively assessed. The primary ischemic endpoint was device-oriented composite endpoint (DOCE) (cardiac death, target-vessel myocardial infarction, and target lesion revascularization) at 1 year, and the primary bleeding endpoint was Bleeding Academic Research Consortium (BARC) 3-5 at 1 year. RESULTS: A total of 5,323 (52.0%) patients had at least 1 high-risk feature. Among patients with high-risk features, DOCE (12.3% vs. 5.5%; p < 0.001) and BARC 3-5 bleeding (4.9% vs. 2.2%; p < 0.001) occurred more frequently compared with those without. There was a graded risk increase for DOCE (0: 5.5%; 1 to 2: 11.3%; and ≥3: 16.7%; p < 0.001) and BARC 3-5 bleeding (0: 2.2%; 1 to 2: 4.5%; and ≥3: 6.6%; p < 0.001) as the number of high-risk features increased. High-PRECISE-DAPT score (≥25) was associated with an increased risk of DOCE and BARC 3-5 bleeding, irrespective of number of high-risk features. CONCLUSIONS: The European Society of Cardiology guideline-endorsed high-risk features were associated with increased ischemic and bleeding risks following percutaneous coronary intervention in routine clinical practice. (CARDIOBASE Bern PCI Registry; NCT02241291).


Decision Support Techniques , Myocardial Ischemia/therapy , Percutaneous Coronary Intervention/instrumentation , Platelet Aggregation Inhibitors/administration & dosage , Stents , Aged , Aged, 80 and over , Drug Therapy, Combination , Female , Hemorrhage/chemically induced , Humans , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/adverse effects , Predictive Value of Tests , Recurrence , Registries , Reproducibility of Results , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
14.
Heart ; 105(14): 1078-1086, 2019 07.
Article En | MEDLINE | ID: mdl-30877239

AIM: To examine the effect of endothelial shear stress (ESS) on the dynamic changes in plaque phenotype. METHODS: Patients with myocardial infarction that had intravascular ultrasound-virtual histology (IVUS-VH) and optical coherence tomography (OCT) at baseline and 13-month follow-up were studied. The IVUS-VH data were used to reconstruct the nonculprit vessels, and in the obtained models the ESS was estimated in 3 mm segments. Plaque morphology was derived in each segment from IVUS-VH and OCT. Disease progression was defined as the presence of ≥2 out of the following criteria: reduction in lumen area, increase in plaque burden and change of plaque morphology to a more vulnerable phenotype. Linear mixed effects models were used to assess the effect of ESS in different phenotypes. RESULTS: Sixty-eight vessels were included in the analysis. Low ESS was associated with plaque progression in all phenotypes. The effect of ESS on plaque burden (p for interaction=0.467) and phenotype (p for interaction=0.188) was similar in all plaque types, whereas the effect of ESS on the changes in lumen dimensions was more prominent in disease-free (ß=0.70, p<0.001) than fibrotic/fibrocalcific (ß=0.28, p<0.001) or lipid-rich plaques (ß=0.15, p=0.015). Standalone IVUS-VH misclassified plaque morphology in one-third of the cases leading to erroneous estimations about the effect of ESS on plaque evolution in different phenotypes. CONCLUSIONS: The effect of ESS on plaque progression is similar in all phenotypes and cannot be accurately assessed by standalone IVUS-VH which often misclassifies plaque morphology. Therefore, multimodality imaging should be considered to examine the implications of ESS on plaque evolution. CLINICAL TRIAL REGISTRATION: NCT00962416; Post-results.


Coronary Vessels , Endothelium, Vascular , Myocardial Infarction , Plaque, Atherosclerotic , Regional Blood Flow , Tomography, Optical Coherence/methods , Ultrasonography, Interventional/methods , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Dimensional Measurement Accuracy , Disease Progression , Endothelium, Vascular/pathology , Endothelium, Vascular/physiopathology , Female , Humans , Male , Middle Aged , Multimodal Imaging , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/physiopathology , Shear Strength/physiology
15.
Swiss Med Wkly ; 149: w20023, 2019 02 25.
Article En | MEDLINE | ID: mdl-30852836

Mitral regurgitation is a highly prevalent condition among elderly patients, affecting almost 10% of the general population aged 75 and older. Left untreated, severe mitral regurgitation results in high mortality and frequent hospitalisation for treatment of heart failure. Surgical treatment remains the first-line therapy for symptomatic, severe mitral regurgitation , especially for patients presenting with a primary aetiology. However, a high proportion of patients with mitral regurgitation are turned down for open-heart surgery, mainly due to advanced age, diminished left ventricular function and comorbidities. Thus, percutaneous treatment options have been recently developed as an alternative. In this article, we will review transcatheter interventional techniques at the level of the mitral valve, including implantation technique, indications and clinical results.


Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Comorbidity , Humans , Mitral Valve Insufficiency/classification , Switzerland , Treatment Outcome , Ventricular Function, Left
16.
Eur Heart J ; 40(24): 1909-1919, 2019 06 21.
Article En | MEDLINE | ID: mdl-30851032

AIMS: The long-term outcomes of biolimus-eluting stents (BESs) with biodegradable polymer as compared with bare-metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain unknown. METHODS AND RESULTS: We performed a 5-year clinical follow-up of 1157 patients (BES: N = 575 and BMS: N = 582) included in the randomized COMFORTABLE AMI trial. Serial intracoronary imaging of stented segments using both intravascular ultrasound (IVUS) and optical coherence tomography performed at baseline and 13 months follow-up were analysed in 103 patients. At 5 years, BES reduced the risk of major adverse cardiac events [MACE; hazard ratio (HR) 0.56, 95% confidence interval (CI): 0.39-0.79, P = 0.001], driven by lower risks for target vessel-related reinfarction (HR 0.44, 95% CI: 0.22-0.87, P = 0.02) and ischaemia-driven target lesion revascularization (HR 0.41, 95% CI: 0.25-0.66, P < 0.001). Definite stent thrombosis (ST) was recorded in 2.2% and 3.9% (HR 0.57, 95% CI: 0.28-1.16, P = 0.12) with no differences in rates of very late definite ST (1.3% vs. 1.6%, P = 0.77). Optical coherence tomography showed no difference in the frequency of malapposed stent struts at follow-up (BES 0.08% vs. BMS 0.02%, P = 0.10). Uncovered stent struts were rarely observed but more frequent in BES (2.1% vs. 0.15%, P < 0.001). In the IVUS analysis, there was no positive remodelling in either group (external elastic membrane area change BES: -0.63 mm2, 95% CI: -1.44 to 0.39 vs. BMS -1.11 mm2, 95% CI: -2.27 to 0.04, P = 0.07). CONCLUSION: Compared with BMS, the implantation of biodegradable polymer-coated BES resulted in a lower 5-year rate of MACE in patients with STEMI undergoing primary percutaneous coronary intervention. At 13 months, vascular healing in treated culprit lesions was almost complete irrespective of stent type. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT00962416.


Drug-Eluting Stents/adverse effects , ST Elevation Myocardial Infarction/surgery , Stents/adverse effects , Absorbable Implants , Acute Disease , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Female , Follow-Up Studies , Humans , Male , Metals , Percutaneous Coronary Intervention/methods , Polymers , Prosthesis Design , ST Elevation Myocardial Infarction/physiopathology , Sirolimus/analogs & derivatives , Stents/trends , Thrombosis/epidemiology , Thrombosis/etiology , Tomography, Optical Coherence/methods , Treatment Outcome , Ultrasonography, Interventional/methods
17.
Am Heart J ; 209: 97-105, 2019 03.
Article En | MEDLINE | ID: mdl-30703644

BACKGROUND: The optimal duration of antiplatelet therapy in high-bleeding risk (HBR) patients with coronary artery disease treated with newer-generation drug-eluting bioresorbable polymer-coated stents remains unclear. DESIGN: MASTER DAPT (clinicaltrial.govNCT03023020) is an investigator-initiated, open-label, multicenter, randomized controlled trial comparing an abbreviated versus a standard duration of antiplatelet therapy after bioresorbable polymer-coated Ultimaster (TANSEI) sirolimus-eluting stent implantation in approximately 4,300 HBR patients recruited from ≥100 interventional cardiology centers globally. After a mandatory 30-day dual-antiplatelet therapy (DAPT) run-in phase, patients are randomized to (a) a single antiplatelet regimen until study completion or up to 5 months in patients with clinically indicated oral anticoagulation (experimental 1-month DAPT group) or (b) continue DAPT for at least 5 months in patients without or 2 in patients with concomitant indication to oral anticoagulation, followed by a single antiplatelet regimen (standard antiplatelet regimen). With a final sample size of 4,300 patients, this study is powered to assess the noninferiority of the abbreviated antiplatelet regimen with respect to the net adverse clinical and major adverse cardiac and cerebral events composite end points and if satisfied for the superiority of abbreviated as compared to standard antiplatelet therapy duration in terms of major or clinically relevant nonmajor bleeding. Study end points will be adjudicated by a blinded Clinical Events Committee. CONCLUSIONS: The MASTER DAPT study is the first randomized controlled trial aiming at ascertaining the optimal duration of antiplatelet therapy in HBR patients treated with sirolimus-eluting bioresorbable polymer-coated stent implantation.


Absorbable Implants/adverse effects , Coronary Artery Disease/surgery , Drug-Eluting Stents/adverse effects , Dual Anti-Platelet Therapy/methods , Percutaneous Coronary Intervention/adverse effects , Polymers , Postoperative Hemorrhage/therapy , Aged, 80 and over , Female , Humans , Immunosuppressive Agents/pharmacology , Male , Percutaneous Coronary Intervention/methods , Postoperative Hemorrhage/etiology , Sirolimus/pharmacology
18.
JACC Cardiovasc Imaging ; 12(8 Pt 1): 1518-1528, 2019 08.
Article En | MEDLINE | ID: mdl-30553686

OBJECTIVES: This study assessed changes in optical coherence tomography (OCT)-defined plaque composition in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin treatment. BACKGROUND: OCT is a high-resolution modality capable of measuring plaque characteristics including fibrous cap thickness (FCT) and macrophage infiltration. There is limited in vivo evidence regarding the effects of statins on OCT-defined coronary atheroma composition and no evidence in the context of STEMI. METHODS: In the IBIS-4 (Integrated Biomarker Imaging Study-4), 103 patients underwent intravascular ultrasonography and OCT of 2 noninfarct-related coronary arteries in the acute phase of STEMI. Patients were treated with high-dose rosuvastatin for 13 months. Serial OCT imaging was available in 153 arteries from 83 patients. We measured FCT by using a semi-automated method. Co-primary endpoints consisted of the change in minimum FCT (measured in fibroatheromas) and change in macrophage line arc. RESULTS: At 13 months, median low-density lipoprotein cholesterol had decreased from 128 mg/dl to 73.6 mg/dl. Minimum FCT, measured in 31 lesions from 27 patients, increased from 64.9 ± 19.9 µm to 87.9 ± 38.1 µm (p = 0.008). Macrophage line arc decreased from 9.6° ± 12.8° to 6.4° ± 9.6° (p < 0.0001). The secondary endpoint, mean lipid arc, decreased from 55.9° ± 37° to 43.5° ± 33.5°. In lesion-level analyses (n = 191), 9 of 13 thin-cap fibroatheromata (TCFAs) at baseline (69.2%) regressed to non-TCFA morphology, whereas 2 of 178 non-TCFA lesions (1.1%) progressed to TCFAs. CONCLUSIONS: In this observational study, we found significant increase in minimum FCT, reduction in macrophage accumulation, and frequent regression of TCFAs to other plaque phenotypes in nonculprit lesions of patients with STEMI treated with high-intensity statin therapy.


Coronary Artery Disease/drug therapy , Coronary Vessels/drug effects , Hydroxymethylglutaryl-CoA Reductase Inhibitors/administration & dosage , Plaque, Atherosclerotic , Rosuvastatin Calcium/administration & dosage , ST Elevation Myocardial Infarction/drug therapy , Tomography, Optical Coherence , Aged , Biomarkers/blood , Cholesterol, LDL/blood , Coronary Artery Disease/blood , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/metabolism , Coronary Vessels/pathology , Female , Fibrosis , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Macrophages/drug effects , Macrophages/pathology , Male , Middle Aged , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Prospective Studies , Rosuvastatin Calcium/adverse effects , ST Elevation Myocardial Infarction/blood , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/pathology , Stents , Time Factors , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 93(5): 982-988, 2019 04 01.
Article En | MEDLINE | ID: mdl-30548794

BACKGROUND: Live case demonstrations serve as an educational tool for interventional techniques in cardiology. The aim of this study was to assess the safety and technical success of percutaneous patent foramen ovale (PFO) closure during live case demonstrations. METHODS: All patients who had undergone percutaneous PFO closure with Amplatzer devices during live case demonstrations at our institution were consecutively included in this retrospective analysis. Procedure related events were compared with summary event rates derived from the eight randomized controlled trials (RCTs) investigating PFO closure, as well as with a propensity matched cohort of patients treated under usual conditions. RESULTS: From April 2004 to June 2015, 142 patients underwent percutaneous PFO closure during live demonstrations, mainly for secondary prevention of cryptogenic cerebrovascular events. The interventions were fluoroscopy guided and successful in all but three cases (2%). Minor adverse events occurred in nine patients (6%). Contrast TEE performed at about 6 months showed complete closure in 84%. No significant differences with regard to technical success and major complications rate were found compared to RCTs, except for an increased rate of minor bleeding observed during live case demonstrations (P for difference < 0.001), mainly attributable to concomitant arterial access for incidental coronary angiography performed in 70% of patients. Except for slightly longer procedure duration, no difference was found compared to a matched population treated under usual conditions. CONCLUSION: Percutaneous PFO closure can be performed during live case demonstrations with the same high technical success as during routine cases.


Cardiac Catheterization , Ductus Arteriosus, Patent/therapy , Education, Medical , Video Recording , Adult , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/physiopathology , Female , Humans , Male , Middle Aged , Patient Safety , Radiography, Interventional , Randomized Controlled Trials as Topic , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
20.
Circ Cardiovasc Interv ; 11(9): e006741, 2018 09.
Article En | MEDLINE | ID: mdl-30354590

BACKGROUND: Biodegradable polymer sirolimus-eluting stents (BP-SESs) have been reported to be noninferior compared with durable polymer everolimus-eluting stents (DP-EES) in a randomized clinical trial. We sought to compare the efficacy and safety of an ultrathin strut BP-SES with a DP-EES in an all-comers population. METHODS AND RESULTS: Among 7640 consecutive patients who underwent percutaneous coronary intervention between March 2011 and June 2015, 4638 patients were exclusively treated with BP-SES (N=1896; 3137 lesions) or DP-EES (N=2742; 4468 lesions). After propensity score matching within strata of clinical indications, the final study population consisted of 2902 matched patients (BP-SES 2406 lesions and DP-EES 2368 lesions). The primary device-oriented composite end point (DOCE) included cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1 year. BP-SES (6.9%) was noninferior to DP-EES (8.0%) with respect to device-oriented composite end point (hazard ratio [HR], 0.85; 95% CI, 0.65-1.11; P for noninferiority <0.001; P for superiority=0.24). No differences in cardiac death (BP-SES, 2.3% versus DP-EES, 3.0%; HR, 0.76; 95% CI, 0.49-1.20; P=0.25), myocardial infarction (BP-SES, 4.6% versus DP-EES, 4.6%; HR, 1.00; 95% CI, 0.71-1.40; P=0.99), or target lesion revascularization (BP-SES, 2.8% versus DP-EES, 2.5%; HR, 1.11; 95% CI, 0.71-1.74; P=0.65) were observed. The rate of periprocedural myocardial infarction was comparable between the 2 groups (2.1% versus 2.2%; HR, 0.97; 95% CI, 0.59-1.58; P=0.89). The rate of definite stent thrombosis was similarly low throughout 1 year (BP-SES, 0.8% versus DP-EES, 0.8%; HR, 1.00; 95% CI, 0.45-2.22; P=1.00). CONCLUSIONS: In a consecutively enrolled percutaneous coronary intervention population reflecting routine clinical practice, BP-SES was noninferior to DP-EES for device-oriented composite end point at 1 year. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02241291.


Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Polymers/chemistry , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/mortality , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Propensity Score , Prospective Studies , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Sirolimus/adverse effects , Switzerland , Time Factors , Treatment Outcome
...