Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 231
1.
J Am Coll Radiol ; 21(6S): S126-S143, 2024 Jun.
Article En | MEDLINE | ID: mdl-38823941

Early detection of breast cancer from regular screening substantially reduces breast cancer mortality and morbidity. Multiple different imaging modalities may be used to screen for breast cancer. Screening recommendations differ based on an individual's risk of developing breast cancer. Numerous factors contribute to breast cancer risk, which is frequently divided into three major categories: average, intermediate, and high risk. For patients assigned female at birth with native breast tissue, mammography and digital breast tomosynthesis are the recommended method for breast cancer screening in all risk categories. In addition to the recommendation of mammography and digital breast tomosynthesis in high-risk patients, screening with breast MRI is recommended. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Breast Neoplasms , Early Detection of Cancer , Evidence-Based Medicine , Societies, Medical , Humans , Breast Neoplasms/diagnostic imaging , Female , Early Detection of Cancer/methods , United States , Mammography/standards , Mammography/methods , Risk Assessment , Mass Screening/methods
2.
Magn Reson Med ; 2024 May 22.
Article En | MEDLINE | ID: mdl-38775077

PURPOSE: To develop a digital reference object (DRO) toolkit to generate realistic breast DCE-MRI data for quantitative assessment of image reconstruction and data analysis methods. METHODS: A simulation framework in a form of DRO toolkit has been developed using the ultrafast and conventional breast DCE-MRI data of 53 women with malignant (n = 25) or benign (n = 28) lesions. We segmented five anatomical regions and performed pharmacokinetic analysis to determine the ranges of pharmacokinetic parameters for each segmented region. A database of the segmentations and their pharmacokinetic parameters is included in the DRO toolkit that can generate a large number of realistic breast DCE-MRI data. We provide two potential examples for our DRO toolkit: assessing the accuracy of an image reconstruction method using undersampled simulated radial k-space data and assessing the impact of the B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity on estimated parameters. RESULTS: The estimated pharmacokinetic parameters for each region showed agreement with previously reported values. For the assessment of the reconstruction method, it was found that the temporal regularization resulted in significant underestimation of estimated parameters by up to 57% and 10% with the weighting factor λ = 0.1 and 0.01, respectively. We also demonstrated that spatial discrepancy of v p $$ {v}_p $$ and PS $$ \mathrm{PS} $$ increase to about 33% and 51% without correction for B 1 + $$ {\mathrm{B}}_1^{+} $$ field. CONCLUSION: We have developed a DRO toolkit that includes realistic morphology of tumor lesions along with the expected pharmacokinetic parameter ranges. This simulation framework can generate many images for quantitative assessment of DCE-MRI reconstruction and analysis methods.

3.
Radiol Artif Intell ; : e240300, 2024 May 29.
Article En | MEDLINE | ID: mdl-38809149

"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. ©RSNA, 2024.

4.
J Imaging Inform Med ; 2024 Mar 14.
Article En | MEDLINE | ID: mdl-38483694

The application of deep learning (DL) in medicine introduces transformative tools with the potential to enhance prognosis, diagnosis, and treatment planning. However, ensuring transparent documentation is essential for researchers to enhance reproducibility and refine techniques. Our study addresses the unique challenges presented by DL in medical imaging by developing a comprehensive checklist using the Delphi method to enhance reproducibility and reliability in this dynamic field. We compiled a preliminary checklist based on a comprehensive review of existing checklists and relevant literature. A panel of 11 experts in medical imaging and DL assessed these items using Likert scales, with two survey rounds to refine responses and gauge consensus. We also employed the content validity ratio with a cutoff of 0.59 to determine item face and content validity. Round 1 included a 27-item questionnaire, with 12 items demonstrating high consensus for face and content validity that were then left out of round 2. Round 2 involved refining the checklist, resulting in an additional 17 items. In the last round, 3 items were deemed non-essential or infeasible, while 2 newly suggested items received unanimous agreement for inclusion, resulting in a final 26-item DL model reporting checklist derived from the Delphi process. The 26-item checklist facilitates the reproducible reporting of DL tools and enables scientists to replicate the study's results.

5.
Radiology ; 310(2): e232030, 2024 Feb.
Article En | MEDLINE | ID: mdl-38411520

According to the World Health Organization, climate change is the single biggest health threat facing humanity. The global health care system, including medical imaging, must manage the health effects of climate change while at the same time addressing the large amount of greenhouse gas (GHG) emissions generated in the delivery of care. Data centers and computational efforts are increasingly large contributors to GHG emissions in radiology. This is due to the explosive increase in big data and artificial intelligence (AI) applications that have resulted in large energy requirements for developing and deploying AI models. However, AI also has the potential to improve environmental sustainability in medical imaging. For example, use of AI can shorten MRI scan times with accelerated acquisition times, improve the scheduling efficiency of scanners, and optimize the use of decision-support tools to reduce low-value imaging. The purpose of this Radiology in Focus article is to discuss this duality at the intersection of environmental sustainability and AI in radiology. Further discussed are strategies and opportunities to decrease AI-related emissions and to leverage AI to improve sustainability in radiology, with a focus on health equity. Co-benefits of these strategies are explored, including lower cost and improved patient outcomes. Finally, knowledge gaps and areas for future research are highlighted.


Artificial Intelligence , Radiology , Humans , Radiography , Big Data , Climate Change
6.
Radiology ; 310(1): e232884, 2024 Jan.
Article En | MEDLINE | ID: mdl-38193834
8.
Radiology ; 310(1): e233537, 2024 Jan.
Article En | MEDLINE | ID: mdl-38289216
10.
IEEE Trans Med Imaging ; 43(1): 351-365, 2024 Jan.
Article En | MEDLINE | ID: mdl-37590109

3D imaging enables accurate diagnosis by providing spatial information about organ anatomy. However, using 3D images to train AI models is computationally challenging because they consist of 10x or 100x more pixels than their 2D counterparts. To be trained with high-resolution 3D images, convolutional neural networks resort to downsampling them or projecting them to 2D. We propose an effective alternative, a neural network that enables efficient classification of full-resolution 3D medical images. Compared to off-the-shelf convolutional neural networks, our network, 3D Globally-Aware Multiple Instance Classifier (3D-GMIC), uses 77.98%-90.05% less GPU memory and 91.23%-96.02% less computation. While it is trained only with image-level labels, without segmentation labels, it explains its predictions by providing pixel-level saliency maps. On a dataset collected at NYU Langone Health, including 85,526 patients with full-field 2D mammography (FFDM), synthetic 2D mammography, and 3D mammography, 3D-GMIC achieves an AUC of 0.831 (95% CI: 0.769-0.887) in classifying breasts with malignant findings using 3D mammography. This is comparable to the performance of GMIC on FFDM (0.816, 95% CI: 0.737-0.878) and synthetic 2D (0.826, 95% CI: 0.754-0.884), which demonstrates that 3D-GMIC successfully classified large 3D images despite focusing computation on a smaller percentage of its input compared to GMIC. Therefore, 3D-GMIC identifies and utilizes extremely small regions of interest from 3D images consisting of hundreds of millions of pixels, dramatically reducing associated computational challenges. 3D-GMIC generalizes well to BCS-DBT, an external dataset from Duke University Hospital, achieving an AUC of 0.848 (95% CI: 0.798-0.896).


Breast , Imaging, Three-Dimensional , Humans , Imaging, Three-Dimensional/methods , Breast/diagnostic imaging , Mammography/methods , Neural Networks, Computer , Image Processing, Computer-Assisted/methods
11.
Breast Cancer Res Treat ; 203(3): 599-612, 2024 Feb.
Article En | MEDLINE | ID: mdl-37897646

PURPOSE: There are insufficient large-scale studies comparing the performance of screening mammography in women of different races. This study aims to compare the screening performance metrics across racial and age groups in the National Mammography Database (NMD). METHODS: All screening mammograms performed between January 1, 2008, and December 31, 2021, in women aged 30-100 years from 746 mammography facilities in 46 U.S. states in the NMD were included. Patients were stratified by 10-year age intervals and 5 racial groups (African American, American Indian, Asian, White, unknown). Incidence of risk factors (breast density, personal history, family history of breast cancer, age), and time since prior exams were compared. Five screening mammography metrics were calculated: recall rate (RR), cancer detection rate (CDR), positive predictive values for recalls (PPV1), biopsy recommended (PPV2) and biopsy performed (PPV3). RESULTS: 29,479,655 screening mammograms performed in 13,181,241 women between January 1, 2008, and December 31, 2021, from the NMD were analyzed. The overall mean performance metrics were RR 10.00% (95% CI 9.99-10.02), CDR 4.18/1000 (4.16-4.21), PPV1 4.18% (4.16-4.20), PPV2 25.84% (25.72-25.97), PPV3 25.78% (25.66-25.91). With advancing age, RR significantly decreases, while CDR, PPV1, PPV2, and PPV3 significantly increase. Incidence of personal/family history of breast cancer, breast density, age, prior mammogram availability, and time since prior mammogram were mostly similar across all races. Compared to White women, African American women had significantly higher RR, but lower CDR, PPV1, PPV2 and PPV3. CONCLUSIONS: Benefits of screening mammography increase with age, including for women age > 70 and across all races. Screening mammography is effective; with lower RR and higher CDR, PPV2, and PPV3 with advancing age. African American women have poorer outcomes from screening mammography (higher RR and lower CDR), compared to White and all women in the NMD. Racial disparity can be partly explained by higher rate of African American women lost to follow up.


Breast Neoplasms , Mammography , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Early Detection of Cancer , Predictive Value of Tests , Biopsy , Mass Screening
13.
Breast Cancer Res Treat ; 203(2): 215-224, 2024 Jan.
Article En | MEDLINE | ID: mdl-37878149

PURPOSE: The impact of opportunistic screening mammography in the United States is difficult to quantify, partially due to lack of inclusion regarding method of detection (MOD) in national registries. This study sought to determine the feasibility of MOD collection in a multicenter community registry and to compare outcomes and characteristics of breast cancer based on MOD. METHODS: We conducted a retrospective study of breast cancer patients from a multicenter tumor registry in Missouri from January 2004 - December 2018. Registry data were extracted by certified tumor registrars and included MOD, clinicopathologic information, and treatment. MOD was assigned as screen-detected or clinically detected. Data were analyzed at the patient level. Chi-squared tests were used for categorical variable comparison and Mann-Whitney-U test was used for numerical variable comparison. RESULTS: 5351 women (median age, 63 years; interquartile range, 53-73 years) were included. Screen-detected cancers were smaller than clinically detected cancers (median size 12 mm vs. 25 mm; P < .001) and more likely node-negative (81% vs. 54%; P < .001), lower grade (P < .001), and lower stage (P < .001). Screen-detected cancers were more likely treated with lumpectomy vs. mastectomy (73% vs. 41%; P < .001) and less likely to require chemotherapy (24% vs. 52%; P < .001). Overall survival for patients with invasive breast cancer was higher for screen-detected cancers (89% vs. 74%, P < .0001). CONCLUSION: MOD can be routinely collected and linked to breast cancer outcomes through tumor registries, with demonstration of significant differences in outcome and characteristics of breast cancers based on MOD. Routine inclusion of MOD in US tumor registries would help quantify the impact of opportunistic screening mammography in the US.


Breast Neoplasms , Female , Humans , Middle Aged , Breast Neoplasms/diagnosis , Breast Neoplasms/epidemiology , Breast Neoplasms/therapy , Mammography/methods , Retrospective Studies , Mastectomy/methods , Early Detection of Cancer/methods , Registries , Mass Screening/methods
14.
Radiology ; 309(3): e233126, 2023 Dec.
Article En | MEDLINE | ID: mdl-38085075
15.
20.
J Magn Reson Imaging ; 2023 Sep 13.
Article En | MEDLINE | ID: mdl-37702382

BACKGROUND: Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion-weighted imaging is helpful in the characterization of breast tumors. However, repeatability/reproducibility studies across scanners and across sites are scarce. PURPOSE: To evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity (Dt ), perfusion fraction (Fp ) and pseudo-diffusion (Dp )) within and across sites employing MRI scanners from different vendors utilizing 16-channel breast array coils in a breast diffusion phantom. STUDY TYPE: Phantom repeatability. PHANTOM: A breast phantom containing tubes of different polyvinylpyrrolidone (PVP) concentrations, water, fat, and sponge flow chambers, together with an MR-compatible liquid crystal (LC) thermometer. FIELD STRENGTH/SEQUENCE: Bipolar gradient twice-refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T. ASSESSMENT: Studies were performed twice in each of two scanners, located at different sites, on each of 2 days, resulting in four studies per scanner. ADCs of the PVP and water were normalized to the vendor-provided calibrated values at the temperature indicated by the LC thermometer for repeatability/reproducibility comparisons. STATISTICAL TESTS: ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within-system coefficient of variation (wCV). Pearson correlation coefficient (r) was also computed between IVIM metrics and flow speed. A P value <0.05 was considered statistically significant. RESULTS: ADC and Dt demonstrated excellent repeatability (<2%; <3%, respectively) and reproducibility (both <5%) at the two sites. Fp and Dp exhibited good repeatability (mean of two sites 3.67% and 5.59%, respectively) and moderate reproducibility (mean of two sites 15.96% and 13.3%, respectively). The mean intersite reproducibility (%) of Fp /Dp /Dt was 50.96/13.68/5.59, respectively. Fp and Dt demonstrated high correlations with flow speed while Dp showed lower correlations. Fp correlations with flow speed were significant at both sites. DATA CONCLUSION: IVIM reproducibility results were promising and similar to ADC, particularly for Dt . The results were reproducible within both sites, and a progressive trend toward reproducibility across sites except for Fp . LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

...