Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Dig Dis Sci ; 44(1): 155-62, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9952237

RESUMEN

We evaluated the agreement between wedged hepatic vein pressure (WHVP), portal vein pressure (PVP), and its relationship with portal hemodynamics in 21 patients with HCV-related cirrhosis with esophageal varices. Direct measurements of the portohepatic gradient (HVPG) were obtained by ultrasound-guided fine needle puncture of the right hepatic and the portal veins. In five cases PVP was 6.4-10.4 mm Hg higher than WHVP. In 12 cases measurements were similar (WHVP - PVP < or = 3 mm Hg). In the remaining four cases WHVP was 3.6-9.6 mm Hg higher than PVP. WHVP and PVP agreement was not related to HVPG mean value, Child-Pugh score, or grading of esophageal varices. By contrast, the difference between WHVP and PVP was inversely related to the portal flow velocity (P = 0.053) and directly related to the portal vascular resistance (P = 0.02). Whereas the portal branches were visualized in patients with WHVP lower or similar to PVP, a predominant left portosystemic collateral flow was observed in patients with WHVP > PVP. Our data point out that, in patients with cirrhosis due to hepatitis C virus infection, discrepant HVPG values reflect true hemodynamic differences.


Asunto(s)
Hemodinámica/fisiología , Venas Hepáticas/fisiopatología , Hepatitis C/complicaciones , Cirrosis Hepática/etiología , Cirrosis Hepática/fisiopatología , Sistema Porta/fisiopatología , Vena Porta/fisiopatología , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Circulación Colateral , Várices Esofágicas y Gástricas/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resistencia Vascular , Presión Venosa/fisiología
2.
Clin Chem ; 27(6): 896-900, 1981 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7237770

RESUMEN

A method is described for separating antibody-bound from free fractions in ligand assays by column affinity chromatography, and its application to radioimmunoassay of choriomammotropin. In the method, 70 x 10 mm (i.d.) polypropylene columns containing about 150 mg of immunosorbent (goat anti-rabbit gamma-globulins covalently linked to Sepharose CL-4B) are used. Standards or unknowns, tracer and antiserum, pipetted into bottom-capped columns, are kept separated from the immunosorbent bed by a porous polyethylene disc and allowed to react for 15 min at room temperature. The reaction mixture is then allowed to pass through the columns by removing the bottom caps. Free antigen is eluted by washing the column, and discarded; antibody-bound fractions remain bound to the immunosorbent. The radioactivity in the columns is counted. The major advantages of the present technique, arising from the liquid-phase reaction combined with the solid-phase separation by column affinity chromatography, are the very low nonspecific binding (less than 1%), good sensitivity (0.02 mg/L), good precision (CV 3.4%), and simple and fast (30-min) assay. For 50 clinical samples so assayed (gamma) and compared with a polyethylene glycol precipitation technique (x), the regression equation was: y - 0.14 + 0.98x (r = 0.994). The assay method was clinical validated by 3493 determinations.


Asunto(s)
Lactógeno Placentario/sangre , Cromatografía de Afinidad/métodos , Femenino , Humanos , Inmunoadsorbentes , Ligandos , Lactógeno Placentario/aislamiento & purificación , Embarazo , Radioinmunoensayo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...