Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Lasers Med Sci ; 38(1): 264, 2023 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-37957337

RESUMEN

Full clearance and no side effects method of treating enlarged veins was successfully accomplished by one laser session. This is the ambition and dream of both dermatologists and patients. Most vascularity treatment protocols had shown some unpleasant adverse effects. The purpose of the present work is to work out, in advance, the accurate dose of laser pulse duration and fluence in order to treat varicose veins in the face, arms and legs with no adverse effects. This mission required the calculation of the exact rise in temperature of the enlarged vein; prior to laser treatment. These pre-calculated temperature rise values were tested on 20 subjects in order to have the best clinical outcomes; using fundamental frequency (1064 nm) pulsed Nd: YAG laser. This work necessitated the use of pulse length (15-30 ms), spot size (3, 5 mm), fluence (110-190 J/cm2) and skin cooling temperature (3-18 °C). Cooling of the skin before and after the treatment was needed to guarantee ultimate impactful results without side effects.


Asunto(s)
Láseres de Estado Sólido , Várices , Humanos , Neodimio , Piel , Láseres de Estado Sólido/uso terapéutico , Várices/terapia , Temperatura , Resultado del Tratamiento
2.
Wiad Lek ; 74(9 cz 2): 2340-2344, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34824181

RESUMEN

OBJECTIVE: The aim: Facial and leg telangiectasia are usual cosmetic concern for females who have different skin phototypes and ages. Until now, the various treatments for these problem have frequently failed or led to unwanted side-effects. Based on approved pre-calculated doses, the present study highlights the clinical effects and safety of treatment after using the exact laser parameters from 1064-nm Nd: YAG laser. PATIENTS AND METHODS: Materials and methods: Twenty people with facial and leg telangiectasia underwent a single laser treatment, based on pre-calculated laser parameters for each case. RESULTS: Results: All subjects showed visible improvement, with 95-100% clearance of face telangiectasia directly after the first treatment, and 50-100% clearance of the lower extremity vessels after one to three days; with minimal side-effects. CONCLUSION: Conclusions: Treatment of facial and leg telangiectasia by using true, exact, and mathematically pre-calculated parameters of long pulse 1064 nm Nd: YAG laser was an effective and safe procedure of clearing face and leg telangiectasia.


Asunto(s)
Terapia por Láser , Telangiectasia , Cara , Femenino , Humanos , Rayos Láser , Pierna , Piel , Telangiectasia/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA