Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
EJNMMI Phys ; 11(1): 11, 2024 Jan 29.
Article En | MEDLINE | ID: mdl-38285319

BACKGROUND: Quantification of the cerebral metabolic rate of glucose (CMRGlu) by dynamic [18F]FDG PET requires invasive arterial sampling. Alternatives to using an arterial input function (AIF) include the simultaneous estimation (SIME) approach, which models the image-derived input function (IDIF) by a series of exponentials with coefficients obtained by fitting time activity curves (TACs) from multiple volumes-of-interest. A limitation of SIME is the assumption that the input function can be modelled accurately by a series of exponentials. Alternatively, we propose a SIME approach based on the two-tissue compartment model to extract a high signal-to-noise ratio (SNR) model-derived input function (MDIF) from the whole-brain TAC. The purpose of this study is to present the MDIF approach and its implementation in the analysis of animal and human data. METHODS: Simulations were performed to assess the accuracy of the MDIF approach. Animal experiments were conducted to compare derived MDIFs to measured AIFs (n = 5). Using dynamic [18F]FDG PET data from neurologically healthy volunteers (n = 18), the MDIF method was compared to the original SIME-IDIF. Lastly, the feasibility of extracting parametric images was investigated by implementing a variational Bayesian parameter estimation approach. RESULTS: Simulations demonstrated that the MDIF can be accurately extracted from a whole-brain TAC. Good agreement between MDIFs and measured AIFs was found in the animal experiments. Similarly, the MDIF-to-IDIF area-under-the-curve ratio from the human data was 1.02 ± 0.08, resulting in good agreement in grey matter CMRGlu: 24.5 ± 3.6 and 23.9 ± 3.2 mL/100 g/min for MDIF and IDIF, respectively. The MDIF method proved superior in characterizing the first pass of [18F]FDG. Groupwise parametric images obtained with the MDIF showed the expected spatial patterns. CONCLUSIONS: A model-driven SIME method was proposed to derive high SNR input functions. Its potential was demonstrated by the good agreement between MDIFs and AIFs in animal experiments. In addition, CMRGlu estimates obtained in the human study agreed to literature values. The MDIF approach requires fewer fitting parameters than the original SIME method and has the advantage that it can model the shape of any input function. In turn, the high SNR of the MDIFs has the potential to facilitate the extraction of voxelwise parameters when combined with robust parameter estimation methods such as the variational Bayesian approach.

2.
Phys Med ; 112: 102604, 2023 Aug.
Article En | MEDLINE | ID: mdl-37429182

PURPOSE: Positron emission tomography (PET) imaging with [18F]FDG provides valuable information regarding the underlying pathological processes in neurodegenerative disorders. PET imaging for these populations should be as short as possible to limit head movements and improve comfort. This study aimed to validate an optimized [18F]FDG-PET image reconstruction protocol aiming to reduce acquisition time while maintaining adequate quantification accuracy and image quality. METHODS: A time-reduced reconstruction protocol (5 min) was evaluated in [18F]FDG-PET retrospective data from healthy individuals and Alzheimer's disease (AD) patients. Standard (8 min) and time-reduced protocols were compared by means of image quality and quantification accuracy metrics, as well as standardized uptake value ratio (SUVR) and Z-scores (pons was used as reference). Images were randomly and blindly presented to experienced physicians and scored in terms of image quality. RESULTS: No differences between protocols were identified during the visual assessment. Small differences (p < 0.01) in the pons SUVR were observed between the standard and time-reduced protocols for healthy individuals (-0.002 ±â€¯0.011) and AD patients (-0.007 ±â€¯0.013). Likewise, incorporating the PSF correction in the reconstruction algorithm resulted in small differences (p < 0.01) in SUVR between protocols (healthy individuals: -0.003 ±â€¯0.011; AD patients: -0.007 ±â€¯0.014). CONCLUSION: Quality metrics were similar between time-reduced and standard protocols. In the visual assessment of the images, the physicians did not consider the use of PSF adequate, as it degraded the quality image. Shortening the acquisition time is possible by optimizing the image reconstruction parameters while maintaining adequate quantification accuracy and image quality.


Alzheimer Disease , Fluorodeoxyglucose F18 , Humans , Retrospective Studies , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Alzheimer Disease/diagnostic imaging
3.
EJNMMI Res ; 13(1): 1, 2023 Jan 12.
Article En | MEDLINE | ID: mdl-36633702

BACKGROUND: The purpose of this study was to assess the feasibility of using a minimally invasive simultaneous estimation method (SIME) to quantify the binding of the 18-kDa translocator protein tracer [18F]FEPPA. Arterial sampling was avoided by extracting an image-derived input function (IDIF) that was metabolite-corrected using venous blood samples. The possibility of reducing scan duration to 90 min from the recommended 2-3 h was investigated by assuming a uniform non-displaceable distribution volume (VND) to simplify the SIME fitting. RESULTS: SIME was applied to retrospective data from healthy volunteers and was comprised of both high-affinity binders (HABs) and mixed-affinity binders (MABs). Estimates of global VND and regional total distribution volume (VT) from SIME were not significantly different from values obtained using a two-tissue compartment model (2CTM). Regional VT estimates were greater for HABs compared to MABs for both the 2TCM and SIME, while the SIME estimates had lower inter-subject variability (41 ± 17% reduction). Binding potential (BPND) values calculated from regional VT and brain-wide VND estimates were also greater for HABs, and reducing the scan time from 120 to 90 min had no significant effect on BPND. The feasibility of using venous metabolite correction was evaluated in a large animal model involving a simultaneous collection of arterial and venous samples. Strong linear correlations were found between venous and arterial measurements of the blood-to-plasma ratio and the remaining [18F]FEPPA fraction. Lastly, estimates of BPND and the specific distribution volume (i.e., VS = VT - VND) from a separate group of healthy volunteers (90 min scan time, venous-scaled IDIFs) agreed with estimates from the retrospective data for both genotypes. CONCLUSIONS: The results of this study demonstrate that accurate estimates of regional VT, BPND and VS can be obtained by applying SIME to [18F]FEPPA data. Furthermore, the application of SIME enabled the scan time to be reduced to 90 min, and the approach worked well with IDIFs that were scaled and metabolite-corrected using venous blood samples.

4.
Neuroimage Clin ; 33: 102950, 2022.
Article En | MEDLINE | ID: mdl-35134705

BACKGROUND: Clinical diagnosis of frontotemporal dementia (FTD) remains a challenge due to the overlap of symptoms among FTD subtypes and with other psychiatric disorders. Perfusion imaging by arterial spin labeling (ASL) is a promising non-invasive alternative to established PET techniques; however, its sensitivity to imaging parameters can hinder its ability to detect perfusion abnormalities. PURPOSE: This study evaluated the similarity of regional hypoperfusion patterns detected by ASL relative to the gold standard for imaging perfusion, PET with radiolabeled water (15O-water). METHODS AND MATERIALS: Perfusion by single-delay pseudo continuous ASL (SD-pCASL), free-lunch Hadamard encoded pCASL (FL_TE-pCASL), and 15O-water data were acquired on a hybrid PET/MR scanner in 13 controls and 9 FTD patients. Cerebral blood flow (CBF) by 15O-water was quantified by a non-invasive approach (PMRFlow). Regional hypoperfusion was determined by comparing individual patients to the control group. This was performed using absolute (aCBF) and CBF normalized to whole-brain perfusion (rCBF). Agreement was assessed based on the fraction of overlapping voxels. Sensitivity and specificity of pCASL was estimated using hypoperfused regions of interest identified by 15O-water. RESULTS: Region of interest (ROI) based perfusion measured by 15O-water strongly correlated with SD-pCASL (R = 0.85 ± 0.1) and FL_TE-pCASL (R = 0.81 ± 0.14). Good agreement in terms of regional hypoperfusion patterns was found between 15O-water and SD-pCASL (sensitivity = 70%, specificity = 78%) and between 15O-water and FL_TE-pCASL (sensitivity = 71%, specificity = 73%). However, SD-pCASL showed greater overlap (43.4 ± 21.3%) with 15O-water than FL_TE-pCASL (29.9 ± 21.3%). Although aCBF and rCBF showed no significant differences regarding spatial overlap and metrics of agreement with 15O-water, rCBF showed considerable variability across subtypes, indicating that care must be taken when selecting a reference region. CONCLUSIONS: This study demonstrates the potential of pCASL for assessing regional hypoperfusion related to FTD and supports its use as a cost-effective alternative to PET.


Frontotemporal Dementia , Cerebrovascular Circulation/physiology , Frontotemporal Dementia/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Spin Labels , Tomography, X-Ray Computed , Water
5.
J Magn Reson Imaging ; 56(4): 1243-1255, 2022 Oct.
Article En | MEDLINE | ID: mdl-35226390

BACKGROUND: Quantification of cerebral blood flow (CBF) with [15 O]H2 O-positron emission tomography (PET) requires arterial sampling to measure the input function. This invasive procedure can be avoided by extracting an image-derived input function (IDIF); however, IDIFs are sensitive to partial volume errors due to the limited spatial resolution of PET. PURPOSE: To present an alternative hybrid PET/MR imaging of CBF (PMRFlowIDIF ) that uses phase-contrast (PC) MRI measurements of whole-brain (WB) CBF to calibrate an IDIF extracted from a WB [15 O]H2 O time-activity curve. STUDY TYPE: Technical development and validation. ANIMAL MODEL: Twelve juvenile Duroc pigs (83% female). POPULATION: Thirteen healthy individuals (38% female). FIELD STRENGTH/SEQUENCES: 3 T; gradient-echo PC-MRI. ASSESSMENT: PMRFlowIDIF was validated against PET-only in a porcine model that included arterial sampling. CBF maps were generated by applying PMRFlowIDIF and two previous PMRFlow methods (PC-PET and double integration method [DIM]) to [15 O]H2 O-PET data acquired from healthy individuals. STATISTICAL TESTS: PMRFlow and PET CBF measurements were compared with regression and correlation analyses. Paired t-tests were performed to evaluate differences. Potential biases were assessed using one-sample t-tests. Reliability was assessed by intraclass correlation coefficients. Statistical significance: α  = 0.05. RESULTS: In the animal study, strong agreement was observed between PMRFlowIDIF (average voxel-wise CBF, 58.0 ± 16.9 mL/100 g/min) and PET (63.0 ± 18.9 mL/100 g/min). In the human study, PMRFlowDIM (y = 1.11x - 5.16, R2  = 0.99 ± 0.01) and PMRFlowPC-PET (y = 0.87x + 3.82, R2  = 0.97 ± 0.02) performed similarly to PMRFlowIDIF, and CBF was within the expected range (eg, 49.7 ± 7.2 mL/100 g/min for gray matter). DATA CONCLUSION: Accuracy of PMRFlowIDIF was confirmed in the animal study with the primary source of error attributed to differences in WB CBF measured by PC MRI and PET. In the human study, differences in CBF from PMRFlowIDIF , PMRFlowDIM , and PMRFlowPC-PET were due to the latter two not accounting for blood-borne activity. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Cerebrovascular Circulation , Positron-Emission Tomography , Animals , Brain/blood supply , Brain/diagnostic imaging , Cerebrovascular Circulation/physiology , Female , Humans , Magnetic Resonance Imaging/methods , Male , Oxygen Radioisotopes , Positron-Emission Tomography/methods , Reproducibility of Results , Swine
6.
Neuroimage Clin ; 35: 102853, 2022.
Article En | MEDLINE | ID: mdl-34697009

BACKGROUND: Advances in the understanding of the pathophysiology of frontotemporal dementia (FTD) and related disorders, along with the development of novel candidate disease modifying treatments, have stimulated the need for tools to assess the efficacy of new therapies. While perfusion imaging by arterial spin labeling (ASL) is an attractive approach for longitudinal imaging biomarkers of neurodegeneration, sources of variability between sessions including arterial transit times (ATT) and fluctuations in resting perfusion can reduce its sensitivity. Establishing the magnitude of perfusion changes that can be reliably detected is necessary to delineate longitudinal perfusion changes related to disease processes from the effects of these sources of error. PURPOSE: To assess the feasibility of ASL for longitudinal monitoring of patients with FTD by quantifying between-session variability of perfusion on a voxel-by-voxel basis. METHODS AND MATERIALS: ASL data were collected in 13 healthy controls and 8 patients with FTD or progressive supra-nuclear palsy. Variability in cerebral blood flow (CBF) by single delay pseudo-continuous ASL (SD-pCASL) acquired one month apart were quantified by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Additionally, CBF by SD-pCASL and ATT by low-resolution multiple inversion time ASL (LowRes-pCASL) were compared to Hadamard encoded sequences which are able to simultaneously measure CBF and ATT with improved time-efficiency. RESULTS: Agreement of grey-matter perfusion between sessions was found for both patients and controls (CV = 10.8% and 8.3% respectively) with good reliability for both groups (ICC > 0.6). Intensity normalization to remove day-to-day fluctuations in resting perfusion reduced the CV by 28%. Less than 5% of voxels had ATTs above the chosen post labelling delay (2 s), indicating that the ATT was not a significant source of error. Hadamard-encoded perfusion imaging yielded systematically higher CBF compared to SD-pCASL, but produced similar transit-time measurements. Power analysis revealed that SD-pCASL has the sensitivity to detect longitudinal changes as low as 10% with as few as 10 patient participants. CONCLUSION: With the appropriate labeling parameters, SD-pCASL is a promising approach for assessing longitudinal changes in CBF associated with FTD.


Frontotemporal Dementia , Cerebrovascular Circulation/physiology , Frontotemporal Dementia/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Perfusion , Reproducibility of Results , Spin Labels
7.
J Nucl Med ; 2021 Mar 19.
Article En | MEDLINE | ID: mdl-33741647

The gold standard for imaging the cerebral metabolic rate of oxygen (CMRO2) is positron emission tomography (PET); however, it is an invasive and complex procedure that also requires correction for recirculating 15O-H2O and the blood-borne activity. We propose a noninvasive reference-based hybrid PET/magnetic resonance imaging (MRI) method that uses functional MRI techniques to calibrate 15O-O2-PET data. Here, PET/MR imaging of oxidative metabolism (PMROx) was validated in an animal model by comparison to PET-alone measurements. Additionally, we investigated if the MRI-perfusion technique arterial spin labelling (ASL) could be used to further simplify PMROx by replacing 15O-H2O-PET, and if the PMROx was sensitive to anesthetics-induced changes in metabolism. Methods: 15O-H2O and 15O-O2 PET data were acquired in a hybrid PET/MR scanner (3 T Siemens Biograph mMR), together with simultaneous functional MRI (OxFlow and ASL), from juvenile pigs (n = 9). Animals were anesthetized with 3% isoflurane and 6 mL/kg/h propofol for the validation experiments and arterial sampling was performed for PET-alone measurements. PMROx estimates were obtained using whole-brain (WB) CMRO2 from OxFlow and local cerebral blood flow (CBF) from either noninvasive 15O-H2O-PET or ASL (PMROxASL). Changes in metabolism were investigated by increasing the propofol infusion to 20 mL/kg/h. Results: Good agreement and correlation were observed between regional CMRO2 measurements from PMROx and PET-alone. No significant differences were found between OxFlow and PET-only measurements of WB oxygen extraction fraction (0.30 ± 0.09 and 0.31 ± 0.09) and CBF (54.1 ± 16.7 and 56.6 ± 21.0 mL/100 g/min), or between PMROx and PET-only CMRO2 estimates (1.89 ± 0.16 and 1.81 ± 0.10 mLO2/100 g/min). Moreover, PMROx and PMROxASL were sensitive to propofol-induced reduction in CMRO2 Conclusion: This study provides initial validation of a noninvasive PET/MRI technique that circumvents many of the complexities of PET CMRO2 imaging. PMROx does not require arterial sampling and has the potential to reduce PET imaging to 15O-O2 only; however, future validation involving human participants are required.

8.
Phys Med Biol ; 66(6): 065009, 2021 03 04.
Article En | MEDLINE | ID: mdl-33596555

Positron emission tomography (PET) remains the gold standard for quantitative imaging of the cerebral metabolic rate of oxygen (CMRO2); however, it is an invasive and complex procedure that requires accounting for recirculating [15O]H2O (RW) and the cerebral blood volume (CBV). This study presents a non-invasive reference-based technique for imaging CMRO2 that was developed for PET/magnetic resonance imaging (MRI) with the goal of simplifying the PET procedure while maintaining its ability to quantify metabolism. The approach is to use whole-brain (WB) measurements of oxygen extraction fraction (OEF) and cerebral blood flow (CBF) to calibrate [15O]O2-PET data, thereby avoiding the need for invasive arterial sampling. Here we present the theoretical framework, along with error analyses, sensitivity to PET noise and inaccuracies in input parameters, and initial assessment on PET data acquired from healthy participants. Simulations showed that neglecting RW and CBV corrections caused errors in CMRO2 of less than ±10% for changes in regional OEF of ±25%. These predictions were supported by applying the reference-based approach to PET data, which resulted in remarkably similar CMRO2 images to those generated by analyzing the same data using a modeling approach that incorporated the arterial input functions and corrected for CBV contributions. Significant correlations were observed between regional CMRO2 values from the two techniques (slope = 1.00 ± 0.04, R 2 > 0.98) with no significant differences found for integration times of 3 and 5 min. In summary, results demonstrate the feasibility of producing quantitative CMRO2 images by PET/MRI without the need for invasive blood sampling.


Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Oxygen Consumption , Positron-Emission Tomography/methods , Adult , Algorithms , Brain/metabolism , Cerebrovascular Circulation , Humans , Magnetic Resonance Imaging/standards , Multimodal Imaging/standards , Positron-Emission Tomography/standards , Reference Standards
...