1 - 20 de 56
1.
Eur Heart J Case Rep ; 8(5): ytae216, 2024 May.
Article En | MEDLINE | ID: mdl-38751903

Background: Ablation failures are common in case of intramural location of the arrhythmogenic substrate. Case summary: We report the case of a patient with cardiomyopathy contributed by frequent monomorphic ventricular arrhythmias (VAs) from intramural basal interventricular septum treated with double-balloon venous ethanol ablation (VEA) after a previous failed endocardial radiofrequency (RF) ablation. Discussion: Double-balloon VEA represents a safe and effective therapeutic option in case of intramural VAs also in the absence of venous collaterals joining selectively an intramural arrhythmic substrate.

2.
Eur Heart J Suppl ; 26(Suppl 2): ii264-ii293, 2024 Apr.
Article En | MEDLINE | ID: mdl-38784671

It has been well assessed that women have been widely under-represented in cardiovascular clinical trials. Moreover, a significant discrepancy in pharmacological and interventional strategies has been reported. Therefore, poor outcomes and more significant mortality have been shown in many diseases. Pharmacokinetic and pharmacodynamic differences in drug metabolism have also been described so that effectiveness could be different according to sex. However, awareness about the gender gap remains too scarce. Consequently, gender-specific guidelines are lacking, and the need for a sex-specific approach has become more evident in the last few years. This paper aims to evaluate different therapeutic approaches to managing the most common women's diseases.

3.
G Ital Cardiol (Rome) ; 25(5): 327-339, 2024 05.
Article It | MEDLINE | ID: mdl-38639123

For many years, cardiac pacing has been based on the stimulation of right ventricular common myocardium to correct diseases of the conduction system. The birth and the development of cardiac resynchronization have led to growing interest in the correction and prevention of pacing-induced dyssynchrony. Many observational studies and some randomized clinical trials have shown that conduction system pacing (CSP) can not only prevent pacing-induced dyssynchrony but can also correct proximal conduction system blocks, with reduction of QRS duration and with equal or greater effectiveness than biventricular pacing. Based on these results, many Italian electrophysiologists have changed the stimulation target from the right ventricular common myocardium to CSP. The two techniques with greater clinical impact are the His bundle stimulation and the left bundle branch pacing. The latter, in particular, because of its easier implantation technique and better electric parameters, is spreading like wildfire and is representing a real revolution in the cardiac pacing field. However, despite the growing amount of data, until now, the European Society of Cardiology guidelines give a very limited role to CSP.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block , Treatment Outcome , Electrocardiography/methods , Heart Conduction System , Cardiac Resynchronization Therapy/methods , Myocardium , Heart Failure/therapy
4.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article En | MEDLINE | ID: mdl-38445836

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
5.
J Cardiovasc Electrophysiol ; 35(5): 965-974, 2024 May.
Article En | MEDLINE | ID: mdl-38477371

INTRODUCTION: Repolarization dispersion in the right ventricular outflow tract (RVOT) contributes to the type-1 electrocardiographic (ECG) phenotype of Brugada syndrome (BrS), while data on the significance and feasibility of mapping repolarization dispersion in BrS patients are scarce. Moreover, the role of endocardial repolarization dispersion in BrS is poorly investigated. We aimed to assess endocardial repolarization patterns through an automated calculation of activation recovery interval (ARI) estimated on unipolar electrograms (UEGs) in spontaneous type-1 BrS patients and controls; we also investigated the relation between ARI and right ventricle activation time (RVAT), and T-wave peak-to-end interval (Tpe) in BrS patients. METHODS: Patients underwent endocardial high-density electroanatomical mapping (HDEAM); BrS showing an overt type-1 ECG were defined as OType1, while those without (latent type-1 ECG and LType1) received ajmaline infusion. BrS patients only underwent programmed ventricular stimulation (PVS). Data were elaborated to obtain ARI corrected with the Bazett formula (ARIc), while RVAT was derived from activation maps. RESULTS: 39 BrS subjects (24 OType1 and 15 LTtype1) and 4 controls were enrolled. OType1 and post-ajmaline LType1 showed longer mean ARIc than controls (306 ± 27.3 ms and 333.3 ± 16.3 ms vs. 281.7 ± 10.3 ms, p = .05 and p < .001, respectively). Ajmaline induced a significant prolongation of ARIc compared to pre-ajmaline LTtype1 (333.3 ± 16.3 vs. 303.4 ± 20.7 ms, p < .001) and OType1 (306 ± 27.3 ms, p < .001). In patients with type-1 ECG (OTtype1 and post-ajmaline LType1) ARIc correlated with RVAT (r = .34, p = .04) and Tpec (r = .60, p < .001), especially in OType1 subjects (r = .55, p = .008 and r = .65 p < .001, respectively). CONCLUSION: ARIc mapping demonstrates increased endocardial repolarization dispersion in RVOT in BrS. Endocardial ARIc positively correlates with RVAT and Tpec, especially in OType1.


Action Potentials , Algorithms , Brugada Syndrome , Electrocardiography , Electrophysiologic Techniques, Cardiac , Endocardium , Heart Rate , Predictive Value of Tests , Humans , Male , Female , Middle Aged , Brugada Syndrome/physiopathology , Brugada Syndrome/diagnosis , Endocardium/physiopathology , Adult , Time Factors , Case-Control Studies , Ajmaline/administration & dosage , Automation , Ventricular Function, Right , Cardiac Pacing, Artificial , Aged , Signal Processing, Computer-Assisted
6.
Heliyon ; 10(3): e25404, 2024 Feb 15.
Article En | MEDLINE | ID: mdl-38333823

Artificial Intelligence (AI) applications and Machine Learning (ML) methods have gained much attention in recent years for their ability to automatically detect patterns in data without being explicitly taught rules. Specific features characterise the ECGs of patients with Brugada Syndrome (BrS); however, there is still ambiguity regarding the correct diagnosis of BrS and its differentiation from other pathologies. This work presents an application of Echo State Networks (ESN) in the Recurrent Neural Networks (RNN) class for diagnosing BrS from the ECG time series. 12-lead ECGs were obtained from patients with a definite clinical diagnosis of spontaneous BrS Type 1 pattern (Group A), patients who underwent provocative pharmacological testing to induce BrS type 1 pattern, which resulted in positive (Group B) or negative (Group C), and control subjects (Group D). One extracted beat in the V2 lead was used as input, and the dataset was used to train and evaluate the ESN model using a double cross-validation approach. ESN performance was compared with that of 4 cardiologists trained in electrophysiology. The model performance was assessed in the dataset, with a correct global diagnosis observed in 91.5 % of cases compared to clinicians (88.0 %). High specificity (94.5 %), sensitivity (87.0 %) and AUC (94.7 %) for BrS recognition by ESN were observed in Groups A + B vs. C + D. Our results show that this ML model can discriminate Type 1 BrS ECGs with high accuracy comparable to expert clinicians. Future availability of larger datasets may improve the model performance and increase the potential of the ESN as a clinical support system tool for daily clinical practice.

7.
G Ital Cardiol (Rome) ; 25(2): 126-139, 2024 Feb.
Article It | MEDLINE | ID: mdl-38270370

It is well established that gender strongly influences cardiovascular risk factors, playing a crucial role in cardiovascular prevention, clinical pathways, diagnostic approach and treatment. Beyond the sex, which is a biological factor, gender entails a socio-cultural condition that impacts access and quality of care due to structural and institutional barriers. However, despite its great importance, this issue has not been adequately covered. Indeed sex and gender differences scarcely impact the clinical approach, creating a lot of disparities in care and outcomes of patients. Therefore, it becomes essential to increase the awareness of the importance of sex and gender influences on cardiovascular diseases. Moreover, new strategies for reducing disparities should be developed. Importantly, these differences should be taken into account in guideline recommendations. In this regard, it is crucial to include a greater number of women in clinical trials, since they are currently underrepresented. Furthermore, more women should be involved as member of international boards in order to develop recommendations and guidelines with more attention to this important topic.The aim of this ANMCO position paper is to shed light on gender differences concerning many cardiovascular drugs in order to encourage a more personalized therapeutic approach.


Cardiovascular Agents , Cardiovascular Diseases , Male , Humans , Female , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/prevention & control , Critical Pathways , Heart Disease Risk Factors
8.
Article En | MEDLINE | ID: mdl-38206450

BACKGROUND: Mitral isthmus (MI) conduction block is a fundamental step in anatomical approach treatment for persistent atrial fibrillation (PeAF). However, MI block is hardly achievable with endocardial ablation only. Retrograde ethanol infusion (EI) into the vein of Marshall (VOM) facilitates MI block. Fluorographic myocardial staining (MS) during VOM-EI could be helpful in predicting procedural alcoholization outcome even if its role is qualitatively assessed in the routine. The aim was to quantitatively assess MS during VOM-EI and to evaluate its association with MI block achievement. METHODS: Consecutive patients undergoing catheter ablation for PeAF at Fondazione Toscana Gabriele Monasterio (Pisa, Italy) from February 2022 to May 2023 were considered. Patients with identifiable VOM were included. A proposed index of MS (MSI) was retrospectively calculated in each included patient. Correlation of MSI with low-voltage zones (LVZ) extension after VOM-EI and its association with MI block achievement were assessed. RESULTS: In total, 42 patients out of 49 (85.8%) had an identifiable VOM. MI block was successfully achieved in 35 patients out of 42 (83.3%). MSI was significantly associated with the occurrence of MI block (OR 1.24 (1.03-1.48); p = 0.022). A higher MSI resulted in reduced ablation time (p = 0.014) and reduced radiofrequency applications (p = 0.002) to obtain MI block. MSI was also associated with MI block obtained by endocardial ablation only (OR 1.07 (1.02-1.13); p = 0.002). MSI was highly correlated with newly formed LVZ extension (r = 0.776; p = 0.001). CONCLUSIONS: In our study cohort, optimal MSI predicts MI block and facilitates its achievement with endocardial ablation only.

9.
Int J Cardiol ; 401: 131682, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38176657

BACKGROUND: Gender-related discrepancies in personal and professional life have been reported among radio-exposed workers. We assessed this topic among cardiac catheterization workers in Italy, with a focus on gender and working position. METHODS: Radio-exposed workers affiliated with the Italian Association of Hospital Cardiologists were invited to answer an online survey, which included 41 questions formatted as multiple choice. RESULTS: Overall, 237 workers responded. The proportion of males was significantly higher than that of females in the population aged >50 years. A greater portion of females than males perceived female-gender discrimination regarding career advancement (77.2% vs 30.9%, p < 0.001) and work compensation (49.1% vs. 17.1%, p < 0.001). There was no difference in perceived gender- discrimination in terms of career advancement opportunities between physician and non-physicians. A larger portion of females than males experienced workplace discrimination (51.8% of females vs. 8.1% of males, p < 0.0001). Non-physician responders made up 38.8% of all respondents and reported a lower yearly radiation exposure than physicians. Non-physicians were more aware of the laws regulating lab access during pregnancy than physicians (93.5% vs. 48.3%, p < 0.0001). A greater percentage of female nurses than physicians communicate without hesitation the pregnancy status to their employers (45.6% vs 20%, p < 0.001). CONCLUSIONS: Gender-based career disparities were perceived among physicians and non-physician staff of cardiology interventional laboratories. Strategies should be implemented to ensure gender equality in career opportunities and to increase knowledge of radioprotection and the laws regulating access to laboratories during pregnancy.


Cardiologists , Cardiology , Physicians , Radiation Exposure , Male , Humans , Female , Pregnancy , Laboratories , Surveys and Questionnaires
10.
Eur J Prev Cardiol ; 31(4): 486-495, 2024 Mar 04.
Article En | MEDLINE | ID: mdl-38198223

AIMS: Right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs) have been associated with the presence of non-ischaemic left ventricular scar (NLVS) in athletes. The aim of this cross-sectional study was to identify clinical and electrocardiogram (ECG) predictors of the presence of NLVS in athletes with RBBB VAs. METHODS AND RESULTS: Sixty-four athletes [median age 39 (24-53) years, 79% males] with non-sustained RBBB VAs underwent cardiac magnetic resonance (CMR) with late gadolinium enhancement in order to exclude the presence of a concealed structural heart disease. Thirty-six athletes (56%) showed NLVS at CMR and were assigned to the NLVS positive group, whereas 28 athletes (44%) to the NLVS negative group. Family history of cardiomyopathy and seven different ECG variables were statistically more prevalent in the NLVS positive group. At univariate analysis, seven ECG variables (low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I-aVL, negative T waves in precordial leads V4-V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads) proved to be statistically associated with the finding of NLVS; these were grouped together in a score. A score ≥2 was proved to be the optimal cut-off point, identifying NLVS athletes in 92% of cases and showing the best accuracy (86% sensitivity and 100% specificity, respectively). However, a cut-off ≥1 correctly identified all patients with NLVS (absence of false negatives). CONCLUSION: In athletes with RBBB morphology non-sustained VAs, specific ECG abnormalities at 12-lead ECG can help in detecting subjects with NLVS at CMR.


In athletes with right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs), the presence of a non-ischaemic left ventricular scar (NLVS) may be highly suspected if one or more of the following electrocardiogram (ECG) characteristics are present at the 12-lead resting ECG: low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I­aVL, negative T waves in precordial leads V4­V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads. This score should be externally validated in a larger population of athletes with VAs. In athletes with RBBB morphology non-sustained Vas, attention should be placed on the 12-lead resting ECG to suspect the presence of an NLVS. In athletes with RBBB VAs and the presence of one or more of the identified ECG characteristics, a cardiac magnetic resonance with late gadolinium enhancement is useful to rule out an NLVS.


Bundle-Branch Block , Ventricular Premature Complexes , Male , Humans , Adult , Female , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/etiology , Cicatrix/pathology , Contrast Media , Cross-Sectional Studies , Gadolinium , Electrocardiography
11.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Article En | MEDLINE | ID: mdl-38242222

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Brugada Syndrome , Electrocardiography , Registries , Humans , Male , Brugada Syndrome/physiopathology , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Female , Middle Aged , Retrospective Studies , Prognosis , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Italy/epidemiology , Follow-Up Studies , Defibrillators, Implantable , Switzerland/epidemiology , Time Factors , Survival Rate/trends , Adult
12.
J Clin Med ; 12(21)2023 Nov 03.
Article En | MEDLINE | ID: mdl-37959380

BACKGROUND: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line. METHODS: Consecutive patients undergoing the first ablation procedure of catheter ablation (CA) for PeAF were enrolled. All patients underwent VOM-EI, PVI, and ablation lines along the roof of the LA, mitral, and cavotricuspid isthmus. LA voltage mapping before and after VOM-EI was also performed. An implantable loop recorder (ILR) was implanted at the end of the ablation in each patient. RESULTS: Thirty-one consecutive patients (66 ± 8 years and 71% male) affected by PeAF were included in this study. The VOM-EI procedural phase lasted 21.4 ± 10.1 min. PV isolation and lines were validated in all subjects. The ML block was achieved within 10.8 ± 8.7 min. At a mean follow-up of 12 ± 7 months, 27 out of 31 (87%) patients remained free from AT/AF recurrences. Among the patients with recurrences, two (50%) had incomplete ablation lesions and three (75%) had "suboptimal" VOM-EI. In 23/31 patients (74%), antiarrhythmic drugs (AADs) were discontinued after 1 month of follow-up. No significant complications were reported during the follow-up. CONCLUSIONS: this single-center experience demonstrates that VOM-EI systematically combined with an anatomical ablation set in patients with PeAF resulted in feasible, safe, and effective freedom from AF/AT recurrences in 87% of the population after a 1-year follow-up period according to an ILR.

13.
J Clin Med ; 12(19)2023 Sep 25.
Article En | MEDLINE | ID: mdl-37834826

Aim: International guidelines on the use of anti-thrombotic therapies in left-sided ablations other than atrial fibrillation (AF) are lacking. The data regarding antiplatelet or anticoagulation strategies after catheter ablation (CA) procedures mainly derive from AF, whereas for the other arrhythmic substrates, the anti-thrombotic approach remains unclear. This survey aims to explore the current practices regarding antithrombotic management before, during, and after left-sided endocardial ablation, not including atrial fibrillation (AF), in patients without other indications for anti-thrombotic therapy. Material and Methods: Electrophysiologists were asked to answer a questionnaire containing questions on antiplatelet (APT) and anticoagulation therapy for the following left-sided procedures: accessory pathway (AP), atrial (AT), and ventricular tachycardia (VT) with and without structural heart disease (SHD). Results: We obtained 41 answers from 41 centers in 15 countries. For AP, before ablation, only four respondents (9.7%) used antiplatelets and two (4.9%) used anticoagulants. At discharge, APT therapy was prescribed by 22 respondents (53.7%), and oral anticoagulant therapy (OAC) only by one (2.4%). In patients with atrial tachycardia (AT), before ablation, APT prophylaxis was prescribed by only four respondents (9.7%) and OAC by eleven (26.8%). At discharge, APT was recommended by 12 respondents (29.3%) and OAC by 24 (58.5%). For VT without SHD, before CA, only six respondents (14.6%) suggested APT and three (7.3%) suggested OAC prophylaxis. At discharge, APT was recommended by fifteen respondents (36.6%) and OAC by five (12.2%). Regarding VT in SHD, before the procedure, eight respondents (19.5%) prescribed APT and five (12.2%) prescribed OAC prophylaxis. At discharge, the administration of anti-thrombotic therapy depended on the LV ejection fraction for eleven respondents (26.8%), on the procedure time for ten (24.4%), and on the radiofrequency time for four (9.8%), with a cut-off value from 1 to 30 min. Conclusions: Our survey indicates that the management of anti-thrombotic therapy surrounding left-sided endocardial ablation of patients without other indications for anti-thrombotic therapy is highly variable. Further studies are necessary to evaluate the safest approach to these procedures.

14.
J Clin Med ; 12(20)2023 Oct 22.
Article En | MEDLINE | ID: mdl-37892812

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a new technology for the management of ICD patients. But what is the patients' perspective? Previous studies on the transvenous ICD (TV-ICD) showed that device implantation is related not only to anxiety and depression because of the fear of ICD shocks, but also to many biopsychosocial factors like body image changes, perceived reduction of socialization and limitation in professional and sports activities. Anxiety and distress are more evident in younger women because of aesthetic reasons. The scar size and the position of the S-ICD can help these patients and positively influence their social relationships. Moreover, the position of the S-ICD reduces possible complications from catheters due to stress injury and can improve patients' professional life by avoiding some work activity limitations. An S-ICD can be also a good option for athletes in avoiding subclavian crash and reducing inappropriate shocks. However, some questions remain unsolved because an S-ICD is not suitable for patients with indications for pacing, cardiac resynchronization therapy or anti-tachycardia pacing. In conclusion, the use of an S-ICD can assist physicians in reducing the negative impact of implantation on the well-being of some groups of patients by helping them to avoid depression and anxiety as well as improving their noncompliance with their medical treatment.

15.
J Clin Med ; 12(18)2023 Sep 13.
Article En | MEDLINE | ID: mdl-37762897

It is well established that direct oral anticoagulants (DOACs) are the cornerstone of anticoagulant strategy in atrial fibrillation (AF) and venous thromboembolism (VTE) and should be preferred over vitamin K antagonists (VKAs) since they are superior or non-inferior to VKAs in reducing thromboembolic risk and are associated with a lower risk of intracranial hemorrhage (IH). In addition, many factors, such as fewer pharmacokinetic interactions and less need for monitoring, contribute to the favor of this therapeutic strategy. Although DOACs represent a more suitable option, several issues should be considered in clinical practice, including drug-drug interactions (DDIs), switching to other antithrombotic therapies, preprocedural and postprocedural periods, and the use in patients with chronic renal and liver failure and in those with cancer. Furthermore, adherence to DOACs appears to remain suboptimal. This narrative review aims to provide a practical guide for DOAC prescription and address challenging scenarios.

16.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37682245

AIMS: This study aims to survey current educational experience and the individual requirements for electrophysiologists in training. METHODS AND RESULTS: The European Heart Rhythm Association (EHRA) e-Communication Committee and the Scientific Initiatives Committee prepared a questionnaire and distributed it via newsletters, Twitter, LinkedIn, and Facebook. The survey consisted of 22 questions collected on an individual basis anonymously. Two hundred and forty-three responders from 35 countries (32% female, age 38 ± 6 years old) completed the survey. This EHRA electrophysiology (EP) fellowship survey showed that (i) hands-on participation and observation of EP procedures are very important; (ii) the main motivations to choose the EP fellowship institution are centre reputation and volume as well as the availability of a structured EP fellowship programme; (iii) 59% passed the EHRA exam and 46% took a national certification exam; (iv) respondents are overall satisfied with their own fellowships, but there are areas of less confidence such as conduction system pacing implantation and cardiac resynchronization therapy implantation; (v) 78% of respondents performed research during their fellowship, (vi) the optimal duration of an EP fellowship should be at least 2 years; and (viii) doing fellowships abroad is beneficial, but significant obstacles exist. CONCLUSION: The results of this EHRA survey may help to refine current EP fellowship programmes to improve the quality of EP training and early career building of young electrophysiologists.


Cardiac Resynchronization Therapy , Fellowships and Scholarships , Humans , Female , Adult , Male , Cardiac Conduction System Disease , Cardiac Electrophysiology , Certification
17.
Front Cardiovasc Med ; 10: 1115328, 2023.
Article En | MEDLINE | ID: mdl-37529713

Aims: Supraventricular tachycardias may trigger atrial fibrillation (AF). The aim of the study was to evaluate the prevalence of supraventricular tachycardia (SVT) inducibility in patients referred for AF ablation and to evaluate the effects of SVT ablation on AF recurrences. Methods and results: 249 patients (mean age: 54 ± 14 years) referred for paroxysmal AF ablation were studied. In all patients, only AF relapses had been documented in the clinical history. 47 patients (19%; mean age: 42 ± 11 years) had inducible SVT during the electrophysiological study and underwent an ablation targeted only at SVT suppression. Ablation was successful in all 47 patients. The ablative procedures were: 11 slow-pathway ablations for atrioventricular nodal re-entrant tachycardia; 6 concealed accessory pathway ablations for atrioventricular re-entrant tachycardia; 17 focal ectopic atrial tachycardia ablations; 13 with only one arrhythmogenic pulmonary vein. No recurrences of SVT were observed during the follow-up (32 ± 18 months). 4 patients (8.5%) showed recurrence of at least one episode of AF. Patients with inducible SVT had less structural heart disease and were younger than those without inducible SVT. Conclusion: A significant proportion of candidates for AF ablation are inducible for an SVT. SVT ablation showed a preventive effect on AF recurrences. Those patients should be selected for simpler ablation procedures tailored only to the triggering arrhythmia suppression.

18.
G Ital Cardiol (Rome) ; 24(9): 711-730, 2023 09.
Article It | MEDLINE | ID: mdl-37642123

Electrical storm (ES) is characterized by at least three separate episodes of ventricular arrhythmia (VA) over 24 h that require treatment or an incessant VA lasting >12 h. The incidence is higher in patients with implantable cardioverter-defibrillators (ICDs) in secondary prevention and the main manifestation is monomorphic VA. ES onset represents a major event in the history of patients with cardiomyopathies that significantly worsens prognosis. The management of ES is complex and requires a multidisciplinary approach including a comprehensive clinical assessment, resuscitation and sedation management skills, ICD reprogramming, ablation, and neuromodulation procedures. ES early recognition and prompt treatment initiation increase the chances of therapeutic success. Each one of these aspects will be properly discussed in the present decalogue. Notably, ES management remains a challenge, with only limited available evidence from small retrospective series and a substantial lack/limited number of randomized or prospective trials. The spectrum of available antiarrhythmic drugs is limited, as well as their efficacy. The future hope is that larger prospective studies will be able to answer important questions, concerning the most effective pharmacologic strategies, the timing for the invasive treatment, the indications for acute neuromodulation strategies and for the circulatory support tools.


Anti-Arrhythmia Agents , Coronary Care Units , Humans , Prospective Studies , Retrospective Studies , Cognition
19.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37498147

AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.


Occupational Exposure , Radiation Exposure , Radiation Injuries , Male , Pregnancy , Female , Humans , Adolescent , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Surveys and Questionnaires , Reproduction , Cardiac Electrophysiology , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage
20.
Expert Rev Cardiovasc Ther ; 21(3): 151-164, 2023 Mar.
Article En | MEDLINE | ID: mdl-36847583

INTRODUCTION: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an established therapy for the prevention of sudden cardiac death (SCD) and an alternative to a transvenous implantable cardioverter-defibrillator system in selected patients. Beyond randomized clinical trials, many observational studies have described the clinical performance of S-ICD across different subgroups of patients. AREAS COVERED: Our review aimed to describe the opportunities and drawbacks of the S-ICD, focusing on their use in special populations and across different clinical settings. EXPERT OPINION: The choice to implant S-ICD should be based on the patient's tailored approach, which takes into account the adequate S-ICD screening at rest or during stress, the infective risk, the ventricular arrhythmia susceptibility, the progressive nature of the underlying disease, the work or sports activity, and the risk of lead-related complications.


Arrhythmias, Cardiac , Defibrillators, Implantable , Humans , Treatment Outcome , Arrhythmias, Cardiac/diagnosis , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects
...