Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 99
1.
J Chromatogr A ; 1720: 464802, 2024 Apr 12.
Article En | MEDLINE | ID: mdl-38507871

Successive multiple ionic-polymer layers (SMILs) have long since proved their worth in capillary electrophoresis as they ensure stable electroosmotic flow (EOF) and relatively high separation efficiency. Recently, we demonstrated that plotting the plate height (H) against the solute migration velocity (u) enabled a reliable quantitative evaluation of the coating performances in terms of separation efficiency. In this work, various physicochemical and chemical parameters of the SMIL coating were studied and optimized in order to decrease the slope of the ascending part of the H vs u curve, which is known to be controlled by the homogeneity in charge of the coating surface and by the possible residual solute adsorption onto the coating surface. SMILs based on poly(diallyldimethylammonium chloride) (PDADMAC) and poly(sodium styrene sulfonate) (PSS) were formed and the effect of each polyelectrolyte molar mass and of the number of polyelectrolyte layers (up to 21 layers) was studied. The use of polyethylene imine as an anchoring first layer was considered. More polyelectrolyte couples based on PDADMAC, polybrene, PSS, poly(vinyl sulfate), and poly(acrylic acid) were tested. Finally, zwitterionic polymers based on the poly(α-l-lysine) scaffold were synthesized and used as the last layer of SMILs, illustrating their ability to finetune the EOF, while maintaining good separation efficiency.


Electrophoresis, Capillary , Polyethylenes , Polymers , Quaternary Ammonium Compounds , Polyelectrolytes , Cations , Electrophoresis, Capillary/methods , Proteins/analysis , Polyethyleneimine
2.
Anal Bioanal Chem ; 416(7): 1599-1612, 2024 Mar.
Article En | MEDLINE | ID: mdl-38296860

Characterization at the subunit level enables detailed mass spectrometric characterization of posttranslational modifications (PTMs) of monoclonal antibodies (mAbs). The implemented reduction often leaves the intramolecular disulfide bridges intact. Here, we present a capillary electrophoretic (CE) method based on a neutral-coated capillary for the separation of immunoglobulin G-degrading enzyme of Streptococcus pyogenes (IdeS) digested and reduced mAb subunits followed by mass spectrometry (MS), MS/MS identification, and trapped ion mobility mass spectrometry (timsTOF). Our CE approach enables the separation of (i) different subunit moieties, (ii) various reduction states, and (iii) positional isomers of these partly reduced subunit moieties. The location of the remaining disulfide bridges can be determined by middle-down electron transfer higher energy collisional dissociation (EThcD) experiments. All these CE-separated variants show differences in ion mobility in the timsTOF measurements. Applying the presented CE-MS/MS method, reduction parameters such as the use of chaotropic salts were studied. For the investigated antibodies, urea improved the subunit reduction significantly, whereas guanidine hydrochloride (GuHCl) leads to multiple signals of the same subunit in the CE separation. The presented CE-MS method is a powerful tool for the disulfide-variant characterization of mAbs on the subunit level. It enables understanding disulfide bridge reduction processes in antibodies and potentially other proteins.


Disulfides , Tandem Mass Spectrometry , Disulfides/chemistry , Electrophoresis, Capillary/methods , Antibodies, Monoclonal/chemistry , Protein Processing, Post-Translational
3.
Biotechnol Bioeng ; 121(4): 1355-1365, 2024 Apr.
Article En | MEDLINE | ID: mdl-38079069

N-linked glycosylation is one of the most important post-translational modifications of monoclonal antibodies (mAbs) and is considered to be a critical quality attribute (CQA), as the glycan composition often has immunomodulatory effects. Since terminal galactose residues of mAbs can affect antibody-dependent cellular cytotoxicity (ADCC), complement-dependent cytolysis (CDC) activation, serum half-life, and antiviral activity it has to be monitored, controlled and modulated to ensure therapeutic effects. The ability of small noncoding microRNAs (miRNAs) to modulate glycosylation in Chinese hamster ovary (CHO) production cells was recently reported establishing miRNAs as engineering tools for modulation of protein glycosylation. In this study, we report the characterization and validation of miRNAs as engineering tools for increased (mmu-miR-452-5p, mmu-miR-193b-3p) or decreased (mmu-miR-7646-5p, mmu-miR-7243-3p, mmu-miR-1668, mmu-let-7c-1-3p, mmu-miR-7665-3p, mmu-miR-6403) degree of galactosylation. Furthermore, the biological mode of action regulating gene expression of the galactosylation pathway was characterized as well as their influence on bioprocess-related parameters. Most important, stable plasmid-based overexpression of these miRNAs represents a versatile tool for engineering N-linked galactosylation to achieve favorable phenotypes in cell lines for biopharmaceutical production.


MicroRNAs , Animals , Cricetinae , MicroRNAs/genetics , Antibodies, Monoclonal/genetics , Antibodies, Monoclonal/metabolism , CHO Cells , Cricetulus , Glycosylation
4.
Proteomics ; 24(3-4): e2300135, 2024 Feb.
Article En | MEDLINE | ID: mdl-37312401

Native mass spectrometry is a rapidly emerging technique for fast and sensitive structural analysis of protein constructs, maintaining the protein higher order structure. The coupling with electromigration separation techniques under native conditions enables the characterization of proteoforms and highly complex protein mixtures. In this review, we present an overview of current native CE-MS technology. First, the status of native separation conditions is described for capillary zone electrophoresis (CZE), affinity capillary electrophoresis (ACE), and capillary isoelectric focusing (CIEF), as well as their chip-based formats, including essential parameters such as electrolyte composition and capillary coatings. Further, conditions required for native ESI-MS of (large) protein constructs, including instrumental parameters of QTOF and Orbitrap systems, as well as requirements for native CE-MS interfacing are presented. On this basis, methods and applications of the different modes of native CE-MS are summarized and discussed in the context of biological, medical, and biopharmaceutical questions. Finally, key achievements are highlighted and concluded, while remaining challenges are pointed out.


Electrophoresis, Capillary , Proteins , Mass Spectrometry/methods , Proteins/analysis , Electrophoresis, Capillary/methods
5.
Electrophoresis ; 2023 Dec 12.
Article En | MEDLINE | ID: mdl-38085142

Ion mobility-mass spectrometry (IM-MS) is an ever-evolving tool to separate ions in the gas phase according to electrophoretic mobility with subsequent mass determination. CE is rarely coupled to IM-MS, possibly due to similar separation mechanisms based on electrophoretic mobility. Here, we investigate the orthogonality of CE and ion mobility (IM) by analyzing a complex peptide mixture (tryptic digest of HeLa proteins) with trapped ion mobility mass spectrometry (TIMS-MS). Using the nanoCEasy interface, excellent sensitivity was achieved by identifying thousands of peptides and achieving a peak capacity of 7500 (CE: 203-323 in a 150 cm long capillary, IM: 27-31). Plotting CE versus mass and CE versus (inverse) mobility, a clear grouping in curved striped patterns is observed according to the charge-to-size and mass-to-charge ratios. The peptide charge in the acidic background electrolyte can be estimated from the number of basic amino acids, with a few exceptions where neighboring effects reduce the positive charge. A surprisingly high orthogonality of CE and IM is observed, which is obviously caused by solvation effects leading to different charges and sizes in the liquid phase compared to the gas phase. A high orthogonality of CE and ion mobility is expected to be observed for other peptide samples as well as other substance classes, making CE-IM-MS a promising tool for various applications.

6.
Anal Bioanal Chem ; 415(16): 3137-3154, 2023 Jul.
Article En | MEDLINE | ID: mdl-37225900

In mass spectrometry (MS)-based metabolomics, there is a great need to combine different analytical separation techniques to cover metabolites of different polarities and apply appropriate multi-platform data processing. Here, we introduce AriumMS (augmented region of interest for untargeted metabolomics mass spectrometry) as a reliable toolbox for multi-platform metabolomics. AriumMS offers augmented data analysis of several separation techniques utilizing a region-of-interest algorithm. To demonstrate the capabilities of AriumMS, five datasets were combined. This includes three newly developed capillary electrophoresis (CE)-Orbitrap MS methods using the recently introduced nanoCEasy CE-MS interface and two hydrophilic interaction liquid chromatography (HILIC)-Orbitrap MS methods. AriumMS provides a novel mid-level data fusion approach for multi-platform data analysis to simplify and speed up multi-platform data processing and evaluation. The key feature of AriumMS lies in the optimized data processing strategy, including parallel processing of datasets and flexible parameterization for processing of individual separation methods with different peak characteristics. As a case study, Saccharomyces cerevisiae (yeast) was treated with a growth inhibitor, and AriumMS successfully differentiated the metabolome based on the augmented multi-platform CE-MS and HILIC-MS investigation. As a result, AriumMS is proposed as a powerful tool to improve the accuracy and selectivity of metabolome analysis through the integration of several HILIC-MS/CE-MS techniques.


Metabolomics , Tandem Mass Spectrometry , Chromatography, Liquid/methods , Metabolomics/methods , Metabolome , Electrophoresis, Capillary/methods
7.
Electrophoresis ; 44(15-16): 1247-1257, 2023 08.
Article En | MEDLINE | ID: mdl-37079448

Capillary zone electrophoresis ultraviolet (CZE-UV) has become increasingly popular for the charge heterogeneity determination of mAbs and vaccines. The ε-aminocaproic acid (eACA) CZE-UV method has been used as a rapid platform method. However, in the last years, several issues have been observed, for example, loss in electrophoretic resolution or baseline drifts. Evaluating the role of eACA on the reported issues, various laboratories were requested to provide their routinely used eACA CZE-UV methods, and background electrolyte compositions. Although every laboratory claimed to use the He et al. eACA CZE-UV method, most methods actually deviate from He's. Subsequently, a detailed interlaboratory study was designed wherein two commercially available mAbs (Waters' Mass Check Standard mAb [pI 7] and NISTmAb [pI 9]) were provided to each laboratory, along with two detailed eACA CZE-UV protocols for a short-end, high-speed, and a long-end, high-resolution method. Ten laboratories participated each using their own instruments, and commodities, showing excellence method performance (relative standard deviations [RSDs] of percent time-corrected main peak areas from 0.2% to 1.9%, and RSDs of migration times from 0.7% to 1.8% [n = 50 per laboratory], analysis times in some cases as short as 2.5 min). This study clarified that eACA is not the main reason for the abovementioned variations.


Aminocaproic Acid , Antibodies, Monoclonal , Antibodies, Monoclonal/analysis , Electrophoresis, Capillary/methods , Electrolytes
8.
J Chromatogr A ; 1695: 463912, 2023 Apr 26.
Article En | MEDLINE | ID: mdl-36972664

Since the introduction of polyelectrolyte multilayers to protein separation in capillary electrophoresis (CE), some progress has been made to improve separation efficiency by varying different parameters, such as buffer ionic strength and pH, polyelectrolyte nature and number of deposited layers. However, CE is often overlooked as it lacks robustness compared to other separation techniques. In this work, critical parameters for the construction of efficient and reproducible Successive multiple ionic-polymer layers (SMIL) coatings were investigated, focusing on experimental conditions, such as vial preparation and sample conservation which were shown to have a significant impact on separation performances. In addition to repeatability, intra- and inter-capillary precision were assessed, demonstrating the improved capability of poly(diallyldimethylammonium chloride) / poly(sodium styrene sulfonate) (PDADMAC / PSS) coated capillaries to separate model proteins in a 2 M acetic acid background electrolyte when all the correct precautions are put in place (with run to run%RSD(tm) < 1.8%, day to day%RSD(tm) < 3.2% and cap to cap%RSD(tm) < 4.6%). The approach recently introduced to calculate retention factors was used to quantify residual protein adsorption onto the capillary wall and to assess capillary coating performances. 5-layer PDADAMAC / PSS coatings led to average retention factors for the five model proteins of ∼4×10-2. These values suggest a relatively low residual protein adsorption leading to reasonably flat plate height vs linear velocity curves, obtained by performing electrophoretic separations at different electrical voltages (-10 to -25 kV).


Electrophoresis, Capillary , Polyelectrolytes/chemistry , Electrophoresis, Capillary/methods , Proteins/isolation & purification , Reproducibility of Results
9.
Metab Eng ; 77: 53-63, 2023 05.
Article En | MEDLINE | ID: mdl-36906118

N-linked glycosylation is a crucial post-translational modification of many biopharmaceuticals, including monoclonal antibodies (mAbs), capable of modifying their biological effect in patients and thus considered as a critical quality attribute (CQA). However, expression of desired and consistent glycosylation patterns remains a constant challenge for the biopharmaceutical industry and constitutes the need for tools to engineer glycosylation. Small non-coding microRNAs (miRNAs) are known regulators of entire gene networks and have therefore the potential of being used as tools for modulation of glycosylation pathways and for glycoengineering. Here, we demonstrate that novel identified natural miRNAs are capable of altering N-linked glycosylation patterns on mAbs expressed in Chinese hamster ovary (CHO) cells. We established a workflow for a functional high-throughput screening of a complete miRNA mimic library and identified 82 miRNA sequences affecting various moieties including galactosylation, sialylation, and α-1,6 linked core-fucosylation, an important glycan feature influencing antibody-dependent cytotoxicity (ADCC). Subsequent validation shed light on the intra-cellular mode of action and the impact on the cellular fucosylation pathway of miRNAs reducing core-fucosylation. While multiplex approaches increased phenotypic effects on the glycan structure, a synthetic biology approach utilizing rational design of artificial miRNAs further enhanced the potential of miRNAs as novel, versatile and tune-able tools for engineering of N-linked glycosylation pathways and expressed glycosylation patterns towards favourable phenotypes.


MicroRNAs , Cricetinae , Animals , Glycosylation , MicroRNAs/genetics , MicroRNAs/metabolism , CHO Cells , Cricetulus , Antibodies, Monoclonal/genetics , Polysaccharides/genetics
10.
Anal Chem ; 95(8): 4059-4066, 2023 02 28.
Article En | MEDLINE | ID: mdl-36800441

Characterization of charge heterogeneity is an essential pillar for pharmaceutical development and quality control of therapeutic monoclonal antibodies (mAbs). The highly selective and commonly applied capillary zone electrophoresis (CZE) method containing high amounts of ε-aminocaproic acid (EACA) provides a detailed and robust charge heterogeneity profile of intact mAb variants. Nevertheless, the exact location of protein modifications within these charge profiles remains ambiguous. Electrospray ionization mass spectrometry (ESI-MS) is a promising tool for this purpose; however, EACA is incompatible with electrospray. In this context, we present a two-dimensional CZE-CZE-MS system to combine efficient charge variant separation of intact mAbs with subsequent peptide analysis after in-capillary digestion of selected charge variants. The first dimension is based on a generic CZE(EACA) method in a fused silica capillary. In the second dimension, a neutral-coated capillary is used for in-capillary reduction and digestion with Tris(2-carboxyethyl)phosphine (TCEP) and pepsin, followed by CZE separation and MS/MS-characterization of the resulting peptides. The setup is demonstrated using stressed and nonstressed mAbs where peaks of basic, main, and acidic variants were transferred in a heart-cut fashion, digested, and characterized on the peptide level. Sequence coverages of more than 90% were obtained for heavy chain (HC) and light chain (LC) for four different mAbs, including low-abundance variants (<2% of the main peak). Frequently observed modifications (deamidation, oxidation, etc.) could be detected and localized. This study demonstrates a proof-of-concept for identification and localization of protein modifications from CZE charge heterogeneity profiles and, in this way, is expected to support the development and quality control testing of protein pharmaceuticals.


Antibodies, Monoclonal , Tandem Mass Spectrometry , Tandem Mass Spectrometry/methods , Antibodies, Monoclonal/chemistry , Peptides , Electrophoresis, Capillary/methods , Digestion
11.
Electrophoresis ; 44(1-2): 246-267, 2023 01.
Article En | MEDLINE | ID: mdl-35977423

The online coupling of microchip electrophoresis (ME) as a fast, highly efficient, and low-cost miniaturized separation technique to mass spectrometry (MS) as an information-rich and sensitive characterization technique results in ME-MS an attractive tool for various applications. In this paper, we review the basic concepts and latest advances in technology for ME coupled to MS during the period of 2016-2021, covering microchip materials, structures, fabrication techniques, and interfacing to electrospray ionization (ESI)-MS and matrix-assisted laser desorption/ionization-MS. Two critical issues in coupling ME and ESI-MS include the electrical connection used to define the electrophoretic field strength along the separation channel and the generation of the electrospray for MS detection, as well as, a miniaturized ESI-tip. The recent commercialization of ME-MS in zone electrophoresis and isoelectric focusing modes has led to the widespread application of these techniques in academia and industry. Here we summarize recent applications of ME-MS for the separation and detection of antibodies, proteins, peptides, carbohydrates, metabolites, and so on. Throughout the paper these applications are discussed in the context of benefits and limitations of ME-MS in comparison to alternative techniques.


Electrophoresis, Microchip , Electrophoresis, Microchip/methods , Electrophoresis, Capillary/methods , Peptides/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Technology
12.
Electrophoresis ; 44(5-6): 540-548, 2023 03.
Article En | MEDLINE | ID: mdl-36148605

Imaged capillary isoelectric focusing (iCIEF) has emerged as an important technique for therapeutic monoclonal antibody (mAb) charge heterogeneity analysis in the biopharmaceutical context, providing imaged detection and quantitation by UV without a mobilization step. Besides quantitation, the characterization of separated charge variants ideally directly by online electrospray ionization-mass spectrometry (ESI-MS) is crucial to ensure product quality, safety, and efficacy. Straightforward direct iCIEF-MS coupling combining high separation efficiency and quantitative results of iCIEF with the characterization power of MS enables deep characterization of mAb charge variants. A short technical setup and optimized methodical parameters (30 nl/min mobilization rate, 2%-4% ampholyte concentration, 0.5-2 mg/ml sample concentration) allow successful mAb charge variant peak assignment from iCIEF to MS. Despite a loss of separation resolution during the transfer, separated intact mAb charge variants, including deamidation as well as major and minor glycoforms even from low abundant charge variants, could be characterized by online ESI-MS with high precision. The presented setup provides a large potential for mAb charge heterogeneity characterization in biopharmaceutical applications.


Antibodies, Monoclonal , Biological Products , Antibodies, Monoclonal/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Isoelectric Focusing/methods , Capillary Isoelectric Focusing
13.
Methods Mol Biol ; 2531: 69-76, 2022.
Article En | MEDLINE | ID: mdl-35941479

Adsorption of analytes, e.g., proteins, often interfere with separation in CE, due to the relatively large surface of the narrow capillary. Coatings often are applied to prevent adsorption and to determine the electroosmotic flow (EOF), which is of major importance for the separation in CE. Successive multiple ionic-polymer layer (SMIL) coatings are frequently used for protein analysis in capillary electrophoresis resulting in high separation efficiency and repeatability. Here, the coating procedure of a five-layer SMIL coating is described using quaternized diethylaminoethyl dextran (DEAEDq) as polycation and poly(methacrylic acid) (PMA) as polyanion. Depending on the analyte, different polyions may be used to increase separation efficiency. However, the coating procedure remains the same.To demonstrate the applicability of SMIL coatings in CE-MS, human hemoglobin was measured in a BGE containing 2 M acetic acid. DEAEDq-PMA coating was found to be the most suitable for hemoglobin analysis due to relatively low reversed electroosmotic mobility leading to increased electrophoretic resolution of closely related proteoforms. Thereby, not only alpha and beta subunit of the hemoglobin could be separated, but also positional isoforms of glycated and carbamylated species were separated within 24 min.


Electrophoresis, Capillary , Polymers , Electroosmosis , Electrophoresis, Capillary/methods , Hemoglobins , Humans , Ions , Mass Spectrometry
14.
J Sep Sci ; 45(12): 2034-2044, 2022 Jun.
Article En | MEDLINE | ID: mdl-35044720

The analysis of monoclonal antibodies glycosylation is a crucial quality control attribute of biopharmaceutical drugs. High throughput screening approaches for antibody glycoform analysis are required in various stages of process optimization. Here, we present high throughput screening suitable mass spectrometry-based workflows for the analysis of intact antibody glycosylation out of cell supernatants. Capillary electrophoresis and liquid chromatography were coupled with quadrupole time-of-flight mass spectrometry or Orbitrap mass spectrometry. Both separation methods offer fast separation (10-15 min) and the capability to prevent the separated cell supernatant matrix to enter the mass spectrometry by post-separation valving. Both mass spectrometry instruments provide comparable results and both are sufficient to determine the glycosylation pattern of the five major glycoforms of the measured antibodies. However, the Orbitrap yields higher sensitivity of 25 µg/mL (CE-nanoCEasy-Orbitrap mass spectrometry) and 5 µg/mL (liquid chromatography-Orbitrap mass spectrometry). Data processing was optimized for a faster processing and easier detection of low abundant glycoforms based on averaged charge-deconvoluted mass spectra. This approach combines a non-target glycoform analysis while yielding the same glycosylation pattern as the traditional approach based on extracted ion traces. The presented methods enable the high throughput screening of the glycosylation pattern of antibodies down to low µg/mL-range out of cell supernatant without any sample preparation.


Antibodies, Monoclonal , Electrophoresis, Capillary , Antibodies, Monoclonal/chemistry , Chromatography, Liquid , Electrophoresis, Capillary/methods , Glycosylation , Mass Spectrometry/methods
15.
Anal Bioanal Chem ; 414(5): 1745-1757, 2022 Feb.
Article En | MEDLINE | ID: mdl-34881393

The ever-increasing complexity of biological samples to be analysed by mass spectrometry has led to the necessity of sophisticated separation techniques, including multidimensional separation. Despite a high degree of orthogonality, the coupling of liquid chromatography (LC) and capillary zone electrophoresis (CZE) has not gained notable attention in research. Here, we present a heart-cut nanoLC-CZE-ESI-MS platform to analyse intact proteins. NanoLC and CZE-MS are coupled using a four-port valve with an internal nanoliter loop. NanoLC and CZE-MS conditions were optimised independently to find ideal conditions for the combined setup. The valve setup enables an ideal transfer efficiency between the dimensions while maintaining good separation conditions in both dimensions. Due to the higher loadability, the nanoLC-CZE-MS setup exhibits a 280-fold increased concentration sensitivity compared to CZE-MS. The platform was used to characterise intact human alpha-1-acid glycoprotein (AGP), an extremely heterogeneous N-glycosylated protein. With the nanoLC-CZE-MS approach, 368 glycoforms can be assigned at a concentration of 50 µg/mL as opposed to the assignment of only 186 glycoforms from 1 mg/mL by CZE-MS. Additionally, we demonstrate that glycosylation profiling is accessible for dried blood spot analysis (25 µg/mL AGP spiked), indicating the general applicability of our setup to biological matrices. The combination of high sensitivity and orthogonal selectivity in both dimensions makes the here-presented nanoLC-CZE-MS approach capable of detailed characterisation of intact proteins and their proteoforms from complex biological samples and in physiologically relevant concentrations.


Chromatography, Liquid/methods , Electrophoresis, Capillary/methods , Mass Spectrometry/methods , Nanotechnology , Orosomucoid/analysis , Glycosylation , Humans , Limit of Detection , Reproducibility of Results
16.
Anal Chem ; 93(44): 14593-14598, 2021 11 09.
Article En | MEDLINE | ID: mdl-34719920

Capillary electrophoresis-mass spectrometry (CE-MS) is a powerful tool in various fields including proteomics, metabolomics, and biopharmaceutical and environmental analysis. Nanoflow sheath liquid (SL) CE-MS interfaces provide sensitive ionization, required in these fields, but are still limited to a few research laboratories as handling is difficult and expertise is necessary. Here, we introduce nanoCEasy, a novel nanoflow SL interface based on 3D printed parts, including our previously reported two capillary approach. The customized plug-and-play design enables the introduction of capillaries and an emitter without any fittings in less than a minute. The transparency of the polymer enables visual inspection of the liquid flow inside the interface. Robust operation was systematically demonstrated regarding the electrospray voltage, the distance between the emitter and MS orifice, the distance between the separation capillary and emitter tip, and different individual emitters of the same type. For the first time, we evaluated the influence of high electroosmotic flow (EOF) separation conditions on a nanoflow SL interface. A high flow from the separation capillary can be outbalanced by increasing the electrospray voltage, leading to an overall increased electrospray flow, which enables stable operation under high-EOF conditions. Overall, the nanoCEasy interface allows easy, sensitive, and robust coupling of CE-MS. We aspire the use of this sensitive, easy-to-use interface in large-scale studies and by nonexperts.


Electrophoresis, Capillary , Spectrometry, Mass, Electrospray Ionization , Metabolomics , Printing, Three-Dimensional , Proteomics
17.
Carbohydr Polym ; 273: 118486, 2021 Dec 01.
Article En | MEDLINE | ID: mdl-34560933

In capillary electrophoresis an enantioseparation of daclatasvir (DCV) was observed in case of heptakis(2,6-di-O-methyl)-ß-CD, heptakis(2-O-methyl)-ß-CD and ß-CD, while two peaks with a plateau were noted for heptakis(2,3,6-tri-O-methyl)-ß-CD and heptakis(2,3-di-O-methyl)-ß-CD indicating a slow equilibrium. Heptakis(6-O-methyl)-ß-CD and heptakis(3-O-methyl)-ß-CD yielded broad peaks. Nuclear magnetic resonance experiments including nuclear Overhauser effect-based techniques revealed inclusion complex formation for all CDs with the biphenyl ring of DCV within the cavity and the valine-pyrrolidine moieties protruding from the torus. However, in case of heptakis(2,6-di-O-methyl)-ß-CD, heptakis(2-O-methyl)-ß-CD and ß-CD higher order structures with 1:3 stoichiometry were concluded, where the valine moieties enter additional CD molecules via the secondary side. Heptakis(2,3,6-tri-O-methyl)-ß-CD and heptakis(2,3-di-O-methyl)-ß-CD yielded primarily 1:1 complexes. Higher order complexes between DCV and heptakis(2,6-di-O-methyl)-ß-CD were corroborated by mass spectrometry. Complex stoichiometry was not the reason for the slow equilibrium yielding the plateau observed in capillary electrophoresis, but structural characteristics of the CDs especially complete methylation of the secondary rim.

18.
Sci Total Environ ; 798: 149012, 2021 Dec 01.
Article En | MEDLINE | ID: mdl-34325133

Liquid separation coupled to mass spectrometry is often used for non-targeted analyses in various fields, such as metabolomics. However, the combination of non-standardized methods, various mass spectrometers (MS) and processing tools for data evaluation affect biomarker discovery potentially. Here, we present a comprehensive study of these factors based on non-targeted liquid chromatography coupled to time-of-flight (TOF) and Orbitrap MS and capillary zone electrophoresis to Orbitrap analyses of the same bioreactor samples, describing the correlation of its gas yield with changing feature signal intensity. The three datasets were processed with MZmine 2 and XCMS online and subsequential Partial Least Square Regression (PLSR) with Variable Importance in Projection (VIP) ranking for feature prioritization. The six feature tables were compared to evaluate their overlap of shared features and the influence of the processing software and MS instrument on the VIP values and fold changes. The overlaps, defined as a fraction of one feature table found in the comparative table, were from 27% to 57% for the comparison of MZmine and XCMS and from 15% to 50% between Orbitrap and TOF data sets, respectively. Considering the most relevant features only (VIP >1.5), the overlaps were increased significantly in all cases from 26% to 95%. For the same data set, both VIP values and fold changes were well correlated, however, varied significantly between TOF and Orbitrap. CE-MS showed higher total feature numbers compared to LC-MS, most likely due to its more appropriate selectivity, different sample preparation, and/or the sensitive nano-ESI interface. Since only less than 10% of MS/MS data overlapped, CE-MS provided complementary information to LC-MS. Overall, our systematic study proves the benefits of using different separation techniques and processing tools but also indicates a significant influence of mass spectrometry on comprehensive biomarker discovery.


Electrophoresis, Capillary , Tandem Mass Spectrometry , Biomarkers , Bioreactors , Chromatography, Liquid
19.
J Pharm Biomed Anal ; 201: 114089, 2021 Jul 15.
Article En | MEDLINE | ID: mdl-33940498

Size heterogeneity analysis by capillary sieving electrophoresis utilizing sodium dodecyl sulfate (CE(SDS)) with optical detection is a major method applied for release and stability testing of monoclonal antibodies (mAbs) in biopharmaceutical applications. Identification of mAb-fragments and impurities observed with CE(SDS) is of outstanding importance for the assessment of critical quality attributes and development of the analytical control system. Mass spectrometric (MS) detection is a powerful tool for protein identification and characterization. Unfortunately, CE(SDS) is incompatible with online MS-hyphenation due to strong ionization suppression of SDS and other separation buffer components. Here, we present a comprehensive platform for full characterization of individual CE(SDS)-separated peaks by CE(SDS)-capillary zone electrophoresis-top-down-MS. The peak of interest is transferred from the first to the second dimension via an 8-port valve to remove MS-incompatible components. Full characterization of mAb byproducts is performed by intact mass determination and fragmentation by electron transfer dissociation, higher-energy collisional dissociation, and ultraviolet photodissociation. This enables online determination of intact mass as well as sequence verification of individual CE(SDS)-separated peaks simultaneously. A more substantiated characterization of unknown CE(SDS) peaks by exact localization of modifications without prior digestion is facilitated. High sensitivity is demonstrated by successful mass and sequence verification of low abundant, unknown CE(SDS) peaks from two stressed mAb samples. Good fragmentation coverages are obtained by MS2, enabling unequivocal identification of these mAb-fragments. Also, the differentiation of reduced/non-reduced intra-protein disulfide bonds is demonstrated. In summary, a reliable and unambiguous online MS2 identification of unknown compounds of low-abundant individual CE(SDS) peaks is enabled.


Antibodies, Monoclonal , Electrophoresis, Capillary , Immunoglobulin Fragments , Mass Spectrometry , Sodium Dodecyl Sulfate
20.
Electrophoresis ; 42(4): 369-373, 2021 02.
Article En | MEDLINE | ID: mdl-32776368

CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.


Electrophoresis, Capillary/instrumentation , Nanotechnology/instrumentation , Spectrometry, Mass, Electrospray Ionization/instrumentation , Bioreactors , Electrophoresis, Capillary/methods , Equipment Design , Spectrometry, Mass, Electrospray Ionization/methods
...