Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Hosp Infect ; 106(1): 53-56, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32526255

RESUMEN

High-efficiency particulate air supplied to a positive-pressure ventilation lobby (PPVL) in isolation rooms offers the dual advantage of protective and source isolation. This study demonstrates the in-use validity of PPVL rooms for protective isolation of patients. Of the 48 PPVL air samples investigated, Aspergillus fumigatus was detected from only one (2%) sample. Local and remote monitoring of the PPVL rooms is essential for the safety of patients and healthcare workers. Remote and point-of-use engineering controls are essential for ongoing ventilation monitoring, but this should be complemented by visual inspection of the isolation suite. Periodic microbiological monitoring should also be considered with other control measures.


Asunto(s)
Microbiología del Aire , Infección Hospitalaria/prevención & control , Control de Infecciones/normas , Respiración con Presión Positiva/normas , Aspergilosis/prevención & control , Aspergilosis/transmisión , Aspergillus fumigatus/patogenicidad , Ambiente Controlado , Personal de Salud , Arquitectura y Construcción de Hospitales , Humanos , Control de Infecciones/métodos , Aislamiento de Pacientes/métodos , Aislamiento de Pacientes/normas