Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 42
1.
Arch Gynecol Obstet ; 309(2): 669-678, 2024 02.
Article En | MEDLINE | ID: mdl-38030855

PURPOSE: Ultrasound-guided manual vacuum aspiration (USG-MVA) is a feasible and effective outpatient treatment to treat early pregnancy loss. METHODS: This was a prospective observational study at a university-affiliated hospital. All women undergoing either a USG-MVA or electric vacuum aspiration (EVA) were invited to return 3-6 months later for follow-up at which women completed a questionnaire to document their post-evacuation menstrual and reproductive history, and underwent a hysteroscopy if they were not pregnant. The severity of intrauterine adhesion (IUA), if present, was graded (Stage I-III) according to the American fertility society classification. RESULTS: A total of 292 women had a hysteroscopy after their initial surgical evacuation, USG-MVA 169(57.9%) versus EVA 123(42.1%). Women undergoing EVA as opposed to a USG-MVA had a 12.9% higher incidence of IUA (24.1% vs. 37.0%, p = 0.042) equivalent to 1.84 times higher risk (95% CI 1.01-3.34; p = 0.048). Women having EVA continued to show an increased but not statistically significant trend towards an increased risk of IUA after adjusting for the type of miscarriage (aOR = 1.3; 95% CI 0.66-2.50; p = 0.46). CONCLUSION: There were no significant differences in their reproductive outcomes and fewer women post-USG-MVA complained of hypomenorrhea. IUA may still occur in women undergoing USG-MVA but it is lower than the rate in women undergoing EVA. Clinical trials registry The trial was registered with the Centre for Clinical Research and Biostatistics - Clinical Trials Registry (CCRBCTR), a partner registry of the WHO Primary Registry-Chinese Clinical Trials Registry (ChiCTR) with a Unique Trial Number: CUHK_CCRB00541 on 22 Dec 2016.


Abortion, Spontaneous , Uterine Diseases , Pregnancy , Female , Humans , Pregnancy Trimester, First , Abortion, Spontaneous/epidemiology , Abortion, Spontaneous/etiology , Abortion, Spontaneous/surgery , Vacuum Curettage/adverse effects , Prospective Studies , Incidence , Uterine Diseases/surgery , Tissue Adhesions/etiology , Tissue Adhesions/surgery , Ultrasonography, Interventional
2.
Palliat Care Soc Pract ; 17: 26323524231214814, 2023.
Article En | MEDLINE | ID: mdl-38044934

Background: Screening patients with patient-reported outcome measures allows identification of palliative care concerns. The Integrated Palliative Care Outcome Scale (IPOS) was developed in the United Kingdom for this purpose. Tools developed in another setting might not be readily usable locally. We previously evaluated the validity and reliability of the IPOS in our cardiology setting. However, it remains uncertain what factors would influence the subsequent implementation of IPOS for routine screening of patients with advanced heart failure in future practice. Objectives: This study aimed to identify the factors that could affect the IPOS implementation for patients with advanced heart failure. Design: This was a qualitative study conducted at the National Heart Centre Singapore. Methods: Patients with advanced heart failure who participated in our previous IPOS validation study were purposively recruited for semi-structured interviews. Healthcare workers caring for these patients and involved in the testing of the IPOS tool were also invited for interviews. The interviews were analyzed thematically and mapped to the Consolidated Framework for Implementation Research (CFIR). Results: Our analysis identified six potential facilitators and six potential barriers to implementation across five major domains of the CFIR (intervention characteristics, inner setting, outer setting, individual characteristics, and process). Facilitators include: (i) perception of utility, (ii) perception of minimal complexity, (iii) perception of relatability, (iv) conducive culture, (v) dedicated resources, and (vi) advocates for implementation. Barriers include: (i) need for adaptation, (ii) mindsets/role strains, (iii) resource constraints, (iv) cultural concerns, (v) individual needs, and (vi) change process. Conclusion: Institutions could focus on cultivating appropriate perceptions and conducive cultures, providing dedicated resources for implementation and introducing facilitators to advocate for implementation. Adaptation of IPOS to suit workflows and individual needs, consideration of change processes, and systemic changes to alleviate cultural, resource, and staff role strains would improve IPOS uptake during actual implementation in clinical services. Trial registration: Not applicable.

3.
Front Psychol ; 14: 1232262, 2023.
Article En | MEDLINE | ID: mdl-38023001

Introduction: The perception of phonemes is guided by both low-level acoustic cues and high-level linguistic context. However, differentiating between these two types of processing can be challenging. In this study, we explore the utility of pupillometry as a tool to investigate both low- and high-level processing of phonological stimuli, with a particular focus on its ability to capture novelty detection and cognitive processing during speech perception. Methods: Pupillometric traces were recorded from a sample of 22 Danish-speaking adults, with self-reported normal hearing, while performing two phonological-contrast perception tasks: a nonword discrimination task, which included minimal-pair combinations specific to the Danish language, and a nonword detection task involving the detection of phonologically modified words within sentences. The study explored the perception of contrasts in both unprocessed speech and degraded speech input, processed with a vocoder. Results: No difference in peak pupil dilation was observed when the contrast occurred between two isolated nonwords in the nonword discrimination task. For unprocessed speech, higher peak pupil dilations were measured when phonologically modified words were detected within a sentence compared to sentences without the nonwords. For vocoded speech, higher peak pupil dilation was observed for sentence stimuli, but not for the isolated nonwords, although performance decreased similarly for both tasks. Conclusion: Our findings demonstrate the complexity of pupil dynamics in the presence of acoustic and phonological manipulation. Pupil responses seemed to reflect higher-level cognitive and lexical processing related to phonological perception rather than low-level perception of acoustic cues. However, the incorporation of multiple talkers in the stimuli, coupled with the relatively low task complexity, may have affected the pupil dilation.

4.
Sens Actuators B Chem ; 387: 133773, 2023 Jul 15.
Article En | MEDLINE | ID: mdl-37056483

The COVID-19 pandemic has highlighted the need to monitor important correlates of immunity on a population-wide level. To this end, we have developed a competitive assay to assess neutralizing antibody (NAb) titer on the giant magnetoresistive (GMR) biosensor platform. We compared the clinical performance of our biosensor with established techniques such as Ortho's VITROS Anti-SARS-CoV-2 IgG Quantitative Antibody test. Results obtained between the VITROS test and the GMR assay showed correlation (r = -0.93). We then validated the assay with patient plasma samples that had been tested using focus reduction neutralization testing (FRNT). The results obtained from our GMR assay exhibit a previously identified trend of increased NAb titers 2 weeks post-vaccination. We further evaluated NAb titers 6 months post-vaccination and observed waning neutralizing antibody titers over that time in vaccinated patients. In addition, we calibrated our assay to an arbitrary unit (IU/mL) using World Health Organization (WHO) reference plasma provided by the National Institute of Biological Standards and Control (NIBSC). Our biosensor provides highly specific and sensitive results in serum and plasma with analytical, clinical, and point-of-care (POC) applications due to quick turnaround times on samples and the cost-effectiveness of the platform.

5.
Palliat Med Rep ; 3(1): 287-295, 2022.
Article En | MEDLINE | ID: mdl-36479550

Background: The Integrated Palliative Care Outcome Scale (IPOS) was developed in the United Kingdom for health assessment in advanced illness. Objectives: To evaluate the validity and reliability of a culturally adapted IPOS (both patient and staff versions) for heart failure (HF). Design/Setting: We recruited HF patients and staff from a tertiary hospital in Singapore. We collected patient IPOS, New York Heart Association (NYHA) status, Edmonton Symptom Assessment System (ESAS) and Minnesota Living with Heart Failure (MLHF) scores at baseline, and patient IPOS at follow-up. Each baseline patient IPOS was matched with a staff IPOS. Measurements: Pearson correlation coefficient (r) between ESAS, MLHF, and patient IPOS was calculated to assess construct validity. The two-sample T-test assessed difference in patient and staff IPOS scores across NYHA status and care settings for known-group validity. Internal consistency of patient and staff IPOS was assessed using Cronbach's alpha (α). Intraclass correlation coefficient (ICC) was used to assess test-retest reliability of patient IPOS and inter-rater reliability between patient and staff IPOS. Results: Ninety-one patients and 12 staff participated. There was strong convergent validity of total patient IPOS with MLHF (r = 0.78) and ESAS (r = 0.81). There were statistically significant differences in total IPOS across care settings (patient-IPOS: 8.05, staff-IPOS 13.61) and NYHA (patient-IPOS: 7.52, staff-IPOS 12.71).There was high internal consistency of total patient (α = 0.83) and staff IPOS (α = 0.88) and high test-retest reliability of patient IPOS (ICC 0.81). Inter-rater reliability (ICC) ranged between 0.82 and 0.91. Conclusion: The IPOS was valid and reliable for HF patients in Singapore.

6.
Trends Hear ; 26: 23312165221130581, 2022.
Article En | MEDLINE | ID: mdl-36305085

The aim of the current study was to investigate whether task-evoked pupillary responses measured during encoding, individual working memory capacity and noise reduction in hearing aids were associated with the likelihood of subsequently recalling an item in an auditory free recall test combined with pupillometry. Participants with mild to moderately severe symmetrical sensorineural hearing loss (n = 21) were included. The Sentence-final Word Identification and Recall (SWIR) test was administered in a background noise composed of sixteen talkers with noise reduction in hearing aids activated and deactivated. The task-evoked peak pupil dilation (PPD) was measured. The Reading Span (RS) test was used as a measure of individual working memory capacity. Larger PPD at a single trial level was significantly associated with higher likelihood of subsequently recalling a word, presumably reflecting the intensity of attention devoted during encoding. There was no clear evidence of a significant relationship between working memory capacity and subsequent memory recall, which may be attributed to the SWIR test and RS test being administered in different modalities, as well as differences in task characteristics. Noise reduction did not have a significant effect on subsequent memory recall. This may be due to the background noise not having a detrimental effect on attentional processing at the favorable signal-to-noise ratio levels at which the test was conducted.


Hearing Aids , Hearing Loss, Sensorineural , Speech Perception , Humans , Speech Perception/physiology , Hearing Loss, Sensorineural/diagnosis , Mental Recall/physiology , Memory, Short-Term
7.
Front Neurosci ; 16: 876807, 2022.
Article En | MEDLINE | ID: mdl-35937878

Despite the evidence of a positive relationship between task demands and listening effort, the Framework for Understanding Effortful Listening (FUEL) highlights the important role of arousal on an individual's choice to engage in challenging listening tasks. Previous studies have interpreted physiological responses in conjunction with behavioral responses as markers of task engagement. The aim of the current study was to investigate the effect of potential changes in physiological arousal, indexed by the pupil baseline, on task engagement over the course of an auditory recall test. Furthermore, the aim was to investigate whether working memory (WM) capacity and the signal-to-noise ratio (SNR) at which the test was conducted had an effect on changes in arousal. Twenty-one adult hearing aid users with mild to moderately severe symmetrical sensorineural hearing loss were included. The pupil baseline was measured during the Sentence-final Word Identification and Recall (SWIR) test, which was administered in a background noise composed of sixteen talkers. The Reading Span (RS) test was used as a measure of WM capacity. The findings showed that the pupil baseline decreased over the course of the SWIR test. However, recall performance remained stable, indicating that the participants maintained the necessary engagement level required to perform the task. These findings were interpreted as a decline in arousal as a result of task habituation. There was no effect of WM capacity or individual SNR level on the change in pupil baseline over time. A significant interaction was found between WM capacity and SNR level on the overall mean pupil baseline. Individuals with higher WM capacity exhibited an overall larger mean pupil baseline at low SNR levels compared to individuals with poorer WM capacity. This may be related to the ability of individuals with higher WM capacity to perform better than individual with poorer WM capacity in challenging listening conditions.

8.
Nurse Educ Today ; 112: 105326, 2022 May.
Article En | MEDLINE | ID: mdl-35298975

BACKGROUND: The Objective Structured Clinical Examination (OSCE) is widely used in nursing education, but its implementation is costly and resource intensive, potentially limiting its feasibility. A five-station OSCE was designed to replace a previously validated 12-station OSCE but was not evaluated for its psychometric properties. PURPOSE: This study aimed to evaluate the validity, reliability, acceptability, educational impact, and cost of a five-station OSCE using Van der Vleuten's utility formula. METHODS: This study was based on a cross-sectional, nonexperimental design involving psychometric testing, a survey, and a cost analysis. RESULTS: The five-station OSCE showed high content and predictive validity and inter-rater reliability among examiners. The OSCE format was well accepted by participants and achieved a cost saving of 45.2% compared with the 12-station format. CONCLUSIONS: The five-station OSCE provides an authentic and objective assessment of competence among newly graduated nurses.


Clinical Competence , Educational Measurement , Cross-Sectional Studies , Humans , Psychometrics , Reproducibility of Results
9.
Biosens Bioelectron ; 202: 113982, 2022 Apr 15.
Article En | MEDLINE | ID: mdl-35033828

Hepatocellular carcinoma (HCC) is one of the leading causes of cancer-related deaths worldwide. Most patients, however, are not diagnosed until advanced stage because early HCC lesions generally cause no overt symptoms, and the presence of cirrhosis adds another layer of complexity. While early diagnosis enables more therapeutic options and greatly improves survival rates, it is difficult to achieve. In order to detect early stage HCC, high-risk patients need to frequently measure serum biomarkers such as alpha-fetoprotein (AFP), and gold standards for detection involve less accessible and costly tests. In this work, we present an automated and mobile magnetoresistive biosensor system that allows quick, easy, and accurate detection of a panel of HCC related biomarkers. We first discuss the underlying principles of the giant magnetoresistive (GMR) biosensor system and its unique advantages in early detection of HCC. We also describe the development of hardware, software, and the bioassay, and demonstrate that it can perform an automated assay in 28 min, providing both qualitative and quantitative results. The user only needs to manually add sample into a disposable cartridge and press a button on the smartphone app, without the need for direct interaction with reagent liquids, or lab skills such as pipetting. With its portability, high sensitivity, and ease-of-use, the presented biosensor system has the potential to empower both medical practitioners and patients to achieve early HCC diagnosis. Furthermore, the GMR biosensor platform can be adapted to detect other protein or DNA biomarkers beyond HCC, bringing the goals of accessible mobile health even closer to reality.


Biosensing Techniques , Carcinoma, Hepatocellular , Liver Neoplasms , Biomarkers , Biomarkers, Tumor , Carcinoma, Hepatocellular/diagnosis , Carcinoma, Hepatocellular/pathology , Humans , Liver Cirrhosis/complications , Liver Neoplasms/diagnosis , Liver Neoplasms/pathology , alpha-Fetoproteins/metabolism
10.
Ear Hear ; 42(6): 1668-1679, 2021.
Article En | MEDLINE | ID: mdl-33859121

OBJECTIVES: Communication requires cognitive processes which are not captured by traditional speech understanding tests. Under challenging listening situations, more working memory resources are needed to process speech, leaving fewer resources available for storage. The aim of the current study was to investigate the effect of task difficulty predictability, that is, knowing versus not knowing task difficulty in advance, and the effect of noise reduction on working memory resource allocation to processing and storage of speech heard in background noise. For this purpose, an "offline" behavioral measure, the Sentence-Final Word Identification and Recall (SWIR) test, and an "online" physiological measure, pupillometry, were combined. Moreover, the outcomes of the two measures were compared to investigate whether they reflect the same processes related to resource allocation. DESIGN: Twenty-four experienced hearing aid users with moderate to moderately severe hearing loss participated in this study. The SWIR test and pupillometry were measured simultaneously with noise reduction in the test hearing aids activated and deactivated in a background noise composed of four-talker babble. The task of the SWIR test is to listen to lists of sentences, repeat the last word immediately after each sentence and recall the repeated words when the list is finished. The sentence baseline dilation, which is defined as the mean pupil dilation before each sentence, and task-evoked peak pupil dilation (PPD) were analyzed over the course of the lists. The task difficulty predictability was manipulated by including lists of three, five, and seven sentences. The test was conducted over two sessions, one during which the participants were informed about list length before each list (predictable task difficulty) and one during which they were not (unpredictable task difficulty). RESULTS: The sentence baseline dilation was higher when task difficulty was unpredictable compared to predictable, except at the start of the list, where there was no difference. The PPD tended to be higher at the beginning of the list, this pattern being more prominent when task difficulty was unpredictable. Recall performance was better and sentence baseline dilation was higher when noise reduction was on, especially toward the end of longer lists. There was no effect of noise reduction on PPD. CONCLUSIONS: Task difficulty predictability did not have an effect on resource allocation, since recall performance was similar independently of whether task difficulty was predictable or unpredictable. The higher sentence baseline dilation when task difficulty was unpredictable likely reflected a difference in the recall strategy or higher degree of task engagement/alertness or arousal. Hence, pupillometry captured processes which the SWIR test does not capture. Noise reduction frees up resources to be used for storage of speech, which was reflected in the better recall performance and larger sentence baseline dilation toward the end of the list when noise reduction was on. Thus, both measures captured different temporal aspects of the same processes related to resource allocation with noise reduction on and off.


Hearing Aids , Speech Perception , Humans , Noise , Pupil/physiology
11.
Front Neurosci ; 15: 636060, 2021.
Article En | MEDLINE | ID: mdl-33841081

OBJECTIVES: Previous research using non-invasive (magnetoencephalography, MEG) and invasive (electrocorticography, ECoG) neural recordings has demonstrated the progressive and hierarchical representation and processing of complex multi-talker auditory scenes in the auditory cortex. Early responses (<85 ms) in primary-like areas appear to represent the individual talkers with almost equal fidelity and are independent of attention in normal-hearing (NH) listeners. However, late responses (>85 ms) in higher-order non-primary areas selectively represent the attended talker with significantly higher fidelity than unattended talkers in NH and hearing-impaired (HI) listeners. Motivated by these findings, the objective of this study was to investigate the effect of a noise reduction scheme (NR) in a commercial hearing aid (HA) on the representation of complex multi-talker auditory scenes in distinct hierarchical stages of the auditory cortex by using high-density electroencephalography (EEG). DESIGN: We addressed this issue by investigating early (<85 ms) and late (>85 ms) EEG responses recorded in 34 HI subjects fitted with HAs. The HA noise reduction (NR) was either on or off while the participants listened to a complex auditory scene. Participants were instructed to attend to one of two simultaneous talkers in the foreground while multi-talker babble noise played in the background (+3 dB SNR). After each trial, a two-choice question about the content of the attended speech was presented. RESULTS: Using a stimulus reconstruction approach, our results suggest that the attention-related enhancement of neural representations of target and masker talkers located in the foreground, as well as suppression of the background noise in distinct hierarchical stages is significantly affected by the NR scheme. We found that the NR scheme contributed to the enhancement of the foreground and of the entire acoustic scene in the early responses, and that this enhancement was driven by better representation of the target speech. We found that the target talker in HI listeners was selectively represented in late responses. We found that use of the NR scheme resulted in enhanced representations of the target and masker speech in the foreground and a suppressed representation of the noise in the background in late responses. We found a significant effect of EEG time window on the strengths of the cortical representation of the target and masker. CONCLUSION: Together, our analyses of the early and late responses obtained from HI listeners support the existing view of hierarchical processing in the auditory cortex. Our findings demonstrate the benefits of a NR scheme on the representation of complex multi-talker auditory scenes in different areas of the auditory cortex in HI listeners.

12.
Ear Hear ; 42(4): 846-859, 2021.
Article En | MEDLINE | ID: mdl-33492008

OBJECTIVES: Actively following a conversation can be demanding and limited cognitive resources must be allocated to the processing of speech, retaining and encoding the perceived content, and preparing an answer. The aim of the present study was to disentangle the allocation of effort into the effort required for listening (listening effort) and the effort required for retention (memory effort) by means of pupil dilation. DESIGN: Twenty-five normal-hearing German speaking participants underwent a sentence final word identification and recall test, while pupillometry was conducted. The participants' task was to listen to a sentence in four-talker babble background noise and to repeat the final word afterward. At the end of a list of sentences, they were asked to recall as many of the final words as possible. Pupil dilation was recorded during different list lengths (three sentences versus six sentences) and varying memory load (recall versus no recall). Additionally, the effect of a noise reduction algorithm on performance, listening effort, and memory effort was evaluated. RESULTS: We analyzed pupil dilation both before each sentence (sentence baseline) as well as the dilation in response to each sentence relative to the sentence baseline (sentence dilation). The pupillometry data indicated a steeper increase of sentence baseline under recall compared to no recall, suggesting higher memory effort due to memory processing. This increase in sentence baseline was most prominent toward the end of the longer lists, that is, during the second half of six sentences. Without a recall task, sentence baseline declined over the course of the list. Noise reduction appeared to have a significant influence on effort allocation for listening, which was reflected in generally decreased sentence dilation. CONCLUSION: Our results showed that recording pupil dilation in a speech identification and recall task provides valuable insights beyond behavioral performance. It is a suitable tool to disentangle the allocation of effort to listening versus memorizing speech.


Speech Perception , Auditory Perception , Humans , Mental Recall , Noise , Speech Intelligibility
13.
Front Neurosci ; 14: 846, 2020.
Article En | MEDLINE | ID: mdl-33071722

OBJECTIVES: Selectively attending to a target talker while ignoring multiple interferers (competing talkers and background noise) is more difficult for hearing-impaired (HI) individuals compared to normal-hearing (NH) listeners. Such tasks also become more difficult as background noise levels increase. To overcome these difficulties, hearing aids (HAs) offer noise reduction (NR) schemes. The objective of this study was to investigate the effect of NR processing (inactive, where the NR feature was switched off, vs. active, where the NR feature was switched on) on the neural representation of speech envelopes across two different background noise levels [+3 dB signal-to-noise ratio (SNR) and +8 dB SNR] by using a stimulus reconstruction (SR) method. DESIGN: To explore how NR processing supports the listeners' selective auditory attention, we recruited 22 HI participants fitted with HAs. To investigate the interplay between NR schemes, background noise, and neural representation of the speech envelopes, we used electroencephalography (EEG). The participants were instructed to listen to a target talker in front while ignoring a competing talker in front in the presence of multi-talker background babble noise. RESULTS: The results show that the neural representation of the attended speech envelope was enhanced by the active NR scheme for both background noise levels. The neural representation of the attended speech envelope at lower (+3 dB) SNR was shifted, approximately by 5 dB, toward the higher (+8 dB) SNR when the NR scheme was turned on. The neural representation of the ignored speech envelope was modulated by the NR scheme and was mostly enhanced in the conditions with more background noise. The neural representation of the background noise was modulated (i.e., reduced) by the NR scheme and was significantly reduced in the conditions with more background noise. The neural representation of the net sum of the ignored acoustic scene (ignored talker and background babble) was not modulated by the NR scheme but was significantly reduced in the conditions with a reduced level of background noise. Taken together, we showed that the active NR scheme enhanced the neural representation of both the attended and the ignored speakers and reduced the neural representation of background noise, while the net sum of the ignored acoustic scene was not enhanced. CONCLUSION: Altogether our results support the hypothesis that the NR schemes in HAs serve to enhance the neural representation of speech and reduce the neural representation of background noise during a selective attention task. We contend that these results provide a neural index that could be useful for assessing the effects of HAs on auditory and cognitive processing in HI populations.

14.
Ear Hear ; 41 Suppl 1: 39S-47S, 2020.
Article En | MEDLINE | ID: mdl-33105258

To increase the ecological validity of outcomes from laboratory evaluations of hearing and hearing devices, it is desirable to introduce more realistic outcome measures in the laboratory. This article presents and discusses three outcome measures that have been designed to go beyond traditional speech-in-noise measures to better reflect realistic everyday challenges. The outcome measures reviewed are: the Sentence-final Word Identification and Recall (SWIR) test that measures working memory performance while listening to speech in noise at ceiling performance; a neural tracking method that produces a quantitative measure of selective speech attention in noise; and pupillometry that measures changes in pupil dilation to assess listening effort while listening to speech in noise. According to evaluation data, the SWIR test provides a sensitive measure in situations where speech perception performance might be unaffected. Similarly, pupil dilation has also shown sensitivity in situations where traditional speech-in-noise measures are insensitive. Changes in working memory capacity and effort mobilization were found at positive signal-to-noise ratios (SNR), that is, at SNRs that might reflect everyday situations. Using stimulus reconstruction, it has been demonstrated that neural tracking is a robust method at determining to what degree a listener is attending to a specific talker in a typical cocktail party situation. Using both established and commercially available noise reduction schemes, data have further shown that all three measures are sensitive to variation in SNR. In summary, the new outcome measures seem suitable for testing hearing and hearing devices under more realistic and demanding everyday conditions than traditional speech-in-noise tests.


Communication , Outcome Assessment, Health Care , Speech Perception , Cognition , Humans , Noise
15.
ACS Sens ; 5(10): 3049-3057, 2020 10 23.
Article En | MEDLINE | ID: mdl-32896123

Liver cirrhosis is one of the leading causes of death in adults worldwide. It is highly prevalent in developing countries and is growing in prevalence in developed countries mostly because of chronic liver diseases, such as chronic hepatitis B and C and alcoholic and nonalcoholic fatty liver disease. However, the prevalence of cirrhosis may be highly underestimated because early stages are asymptomatic and current early detection methods are inadequate. Here, we evaluate the potential of a set of novel cirrhotic protein biomarkers, including soluble intercellular adhesion molecule-1 and mac-2 binding protein glycosylation isomer, for early detection of cirrhosis in a multiplexed assay using our giant magnetoresistive (GMR) sensor arrays. We evaluated the diagnostic performance of the biomarkers, individually and in combination, using multivariate logistic regression and random forest in a blinded proof-of-concept retrospective case-controlled study. The biomarkers in combination exhibited high diagnostic performance in both logistic regression and random forest models, with an area under the curve of 0.98 (0.94-1.00). In addition, the combination of biomarkers resulted in a high sensitivity of 0.97 (0.95-1.00) and a high specificity of 1.00. We showed that the diagnostic performance of our novel set of cirrhotic protein biomarkers on our multiplexed GMR sensor arrays is higher than the performance of currently used clinical biomarkers and factors (i.e., age, sex, alanine aminotransferase, aspartate aminotransferase, etc.). With this combination of novel biomarkers and GMR technology, we could potentially boost the diagnostic power of early cirrhosis detection.


Biosensing Techniques , Hepatitis B, Chronic , Aspartate Aminotransferases , Humans , Liver Cirrhosis/diagnosis , Retrospective Studies
16.
Biosens Bioelectron ; 165: 112454, 2020 Oct 01.
Article En | MEDLINE | ID: mdl-32729549

The rapidly spreading outbreak of COVID-19 disease is caused by the SARS-CoV-2 virus, first reported in December 2019 in Wuhan, China. As of June 17, 2020, this virus has infected over 8.2 million people but ranges in symptom severity, making it difficult to assess its overall infection rate. There is a need for rapid and accurate diagnostics to better monitor and prevent the spread of COVID-19. In this review, we present and evaluate two main types of diagnostics with FDA-EUA status for COVID-19: nucleic acid testing for detection of SARS-CoV-2 RNA, and serological assays for detection of SARS-CoV-2 specific IgG and IgM patient antibodies, along with the necessary sample preparation for accurate diagnoses. In particular, we cover and compare tests such as the CDC 2019-nCoV RT-PCR Diagnostic Panel, Cellex's qSARS-CoV-2 IgG/IgM Rapid Test, and point-of-care tests such as Abbott's ID NOW COVID-19 Test. Antibody testing is especially important in understanding the prevalence of the virus in the community and to identify those who have gained immunity. We conclude by highlighting the future of COVID-19 diagnostics, which include the need for quantitative testing and the development of emerging biosensors as point-of-care tests.


Betacoronavirus/isolation & purification , Coronavirus Infections/diagnosis , Immunoassay/methods , Pneumonia, Viral/diagnosis , Point-of-Care Testing , Reverse Transcriptase Polymerase Chain Reaction/methods , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , COVID-19 , Coronavirus Infections/blood , Humans , Immunoassay/instrumentation , Immunoglobulin G/analysis , Immunoglobulin G/blood , Immunoglobulin M/analysis , Immunoglobulin M/blood , Pandemics , Pneumonia, Viral/blood , RNA, Viral/analysis , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , SARS-CoV-2 , Specimen Handling/instrumentation , Specimen Handling/methods , United States , United States Food and Drug Administration
17.
Int J Audiol ; 59(10): 792-800, 2020 10.
Article En | MEDLINE | ID: mdl-32564633

OBJECTIVE: In the present study, we investigated whether varying the task difficulty of the Sentence-Final Word Identification and Recall (SWIR) Test has an effect on the benefit of noise reduction, as well as whether task difficulty predictability affects recall. The relationship between working memory and recall was examined. DESIGN: Task difficulty was manipulated by varying the list length with noise reduction on and off in competing speech and speech-shaped noise. Half of the participants were informed about list length in advance. Working memory capacity was measured using the Reading Span. STUDY SAMPLE: Thirty-two experienced hearing aid users with moderate sensorineural hearing loss. RESULTS: Task difficulty did not affect the noise reduction benefit and task difficulty predictability did not affect recall. Participants may have employed a different recall strategy when task difficulty was unpredictable and noise reduction off. Reading Span scores positively correlated with the SWIR test. Noise reduction improved recall in competing speech. CONCLUSIONS: The SWIR test with varying list length is suitable for detecting the benefit of noise reduction. The correlation with working memory suggests that the SWIR test could be modified to be adaptive to individual cognitive capacity. The results on noise and noise reduction replicate previous findings.


Hearing Aids , Hearing Loss, Sensorineural , Speech Perception , Hearing Loss, Sensorineural/diagnosis , Humans , Memory, Short-Term , Mental Recall , Noise/adverse effects
18.
BMC Womens Health ; 20(1): 86, 2020 04 29.
Article En | MEDLINE | ID: mdl-32349724

BACKGROUND: Fertility preservation for both medical and non-medical reasons are gaining increasing attention world-wide. This study aimed to evaluate the awareness, knowledge and acceptance on fertility preservation in Hong Kong Chinese. METHODS: This was a cross-sectional study carried out between June 2016 to March 2017. A self-administered questionnaire was distributed by convenience sampling. RESULTS: Forty two percent of subjects returned the questionnaire (n = 296/697). Among them, only 54.3% were aware of any means of fertility preservation. Tertiary educated individuals are more aware than less educated individuals (73.6% versus 46.6%, p < 0.001). The most commonly known method is oocyte cryopreservation (94.3%). Most of the respondents (80%) were interested to know about fertility preservation, 84.1% considered fertility preservation counselling necessary and 83.3% would consider undergoing fertility preservation if a treatment has a high chance of causing infertility despite the possibility of delay in cancer treatment. Up to 93.9% agreed to set up a dedicated referral centre with government funding and 73.4% agreed that fertility preservation for medical indication should be provided as a government funded service. In terms of fertility preservation for non-medical reason, 65.5 and 70.4% agreed that fertility preservation should be offered to single men and women without partner respectively, while only 53.3 and 50% agreed that fertility preservation is acceptable for delay in childbearing for career development in female and male respectively. CONCLUSION: There was a low awareness but positive attitude towards fertility preservation among Hong Kong Chinese. Acceptance towards medically indicated fertility preservation is high while a considerable number also accepts it for non-medical reasons. Educational campaigns are required to arouse awareness of fertility preservation to prevent individuals being deprived of the option due to lack of knowledge. Dedicated referral centre with established efficient patient referral pathways and financial support should be provided to improve the provision and uptake of fertility preservation service to enhance the reproductive potential and life options of women.


Asian People/psychology , Cryopreservation , Fertility Preservation/psychology , Health Knowledge, Attitudes, Practice/ethnology , Patient Acceptance of Health Care/ethnology , Adolescent , Adult , Cross-Sectional Studies , Female , Hong Kong , Humans , Male , Middle Aged , Oocytes , Surveys and Questionnaires , Young Adult
19.
Int J Audiol ; 59(3): 208-218, 2020 03.
Article En | MEDLINE | ID: mdl-31809220

Objective: The aim of this study was to examine how background noise and hearing aid experience affect the robust relationship between working memory and speech recognition.Design: Matrix sentences were used to measure speech recognition in noise. Three measures of working memory were administered. Study sample: 148 participants with at least 2 years of hearing aid experience.Results: A stronger overall correlation between working memory and speech recognition performance was found in a four-talker babble than in a stationary noise background. This correlation was significantly weaker in participants with most hearing aid experience than those with least experience when background noise was stationary. In the four-talker babble, however, no significant difference was found between the strength of correlations between users with different experience.Conclusion: In general, more explicit processing of working memory is invoked when listening in a multi-talker babble. The matching processes (cf. Ease of Language Understanding model, ELU) were more efficient for experienced than for less experienced users when perceiving speech. This study extends the existing ELU model that mismatch may also lead to the establishment of new phonological representations in the long-term memory.


Auditory Threshold , Hearing Aids/psychology , Hearing Loss, Sensorineural/psychology , Memory, Short-Term , Speech Perception , Aged , Female , Hearing Loss, Sensorineural/rehabilitation , Humans , Male , Middle Aged , Noise , Perceptual Masking , Regression Analysis , Speech Reception Threshold Test , Time Factors
20.
Sci Rep ; 9(1): 15615, 2019 10 30.
Article En | MEDLINE | ID: mdl-31666635

Hepatitis B virus (HBV) infection has a global reach with high prevalence in resource-limited areas like China and Africa. HBV patients in these areas have limited access to the currently used, costly HBV assays, which are performed in centralized clinical laboratories using single-plexed assays with bulky and expensive instruments. We aim to overcome these limitations by developing a simple and affordable HBV diagnostic platform to allow for timelier diagnosis and intervention of HBV infection. Using giant magnetoresistive (GMR) biosensor chips, we developed an automated and multiplexed quantitative platform for the measurement of a panel of HBV serology markers, including HBV "e" antigen (HBeAg), HBV surface antigen (HBsAg), and the antibody against HBsAg (anti-HBs). Our assay platform was able to detect each HBV marker with high specificity and sensitivity (with three orders of magnitude in dynamic range for each marker). Blinded analysis of HBV patient sera showed excellent correlation between our multiplexed quantitative HBsAg results and the qualitative results obtained using FDA-approved immunoassays, as well as those obtained using quantitative, single-plexed, enzyme-linked immunosorbent assays (ELISAs). The portable, automated, multiplexed, quantitative HBV serology assay platform we designed shows great promise as a more accessible alternative for HBV screening, diagnosis, and treatment monitoring.


Biosensing Techniques/instrumentation , Hepatitis B/diagnosis , Point-of-Care Systems , Automation , Hepatitis B/transmission , Humans
...