1.
Bioengineered ; 13(1): 876-883, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34968171

RESUMEN

This research has developed a method for rapid detection of SARS-CoV-2 N protein on a paper-based microfluidic chip. The chitosan-glutaraldehyde cross-linking method is used to fix the coated antibody, and the sandwich enzyme-linked immunosorbent method is used to achieve the specific detection of the target antigen. The system studied the influence of coating antibody concentration and enzyme-labeled antibody concentration on target antigen detection. According to the average gray value measured under different N protein concentrations, the standard curve of the method was established and the sensitivity was tested, and its linear regression was obtained. The equation is y = 9.8286x+137.6, R2 = 0.9772 > 0.90, which shows a high degree of fit. When the concentration of coating antibody and enzyme-labeled antibody were 1 µg/mL and 2 µg/mL, P > 0.05, the difference was not statistically significant, so the lower concentration of 1 µg/mL was chosen as the coating antibody concentration. The results show that the minimum concentration of N protein that can be detected by this method is 8 µg/mL, and the minimum concentration of coating antibody and enzyme-labeled antibody is 1 µg/mL, which has the characteristics of high sensitivity and good repeatability.


Asunto(s)
Antígenos Virales/análisis , Prueba Serológica para COVID-19/instrumentación , Proteínas de la Nucleocápside de Coronavirus/análisis , Proteínas de la Nucleocápside de Coronavirus/inmunología , Dispositivos Laboratorio en un Chip , SARS-CoV-2/química , SARS-CoV-2/inmunología , Anticuerpos Antivirales/inmunología , Ingeniería Biomédica , COVID-19/diagnóstico , COVID-19/inmunología , COVID-19/virología , Prueba Serológica para COVID-19/métodos , Prueba Serológica para COVID-19/normas , Proteínas de la Nucleocápside de Coronavirus/normas , Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Humanos , Dispositivos Laboratorio en un Chip/normas , Dispositivos Laboratorio en un Chip/estadística & datos numéricos , Procedimientos Analíticos en Microchip/métodos , Procedimientos Analíticos en Microchip/normas , Procedimientos Analíticos en Microchip/estadística & datos numéricos , Papel , Fosfoproteínas/análisis , Fosfoproteínas/inmunología , Fosfoproteínas/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA