Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Methods ; 14(2): 180-187, 2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-34935789

RESUMEN

The aim of this work was to develop a sequential injection (SI) method for the determination of the micronutrients iron and manganese, in soil leachates, as a tool to assess potential groundwater contamination. The described sequential injection method was based on the reaction of iron with chelator MRB12, a greener alternative chromogenic reagent, and the reaction of manganese with zincon, within a single manifold. The developed SI method enabled the determination of iron in the range 0.10-1.00 mg L-1, and manganese in the range 0.25-2.5 mg L-1 with a limit of detection of 0.08 mg L-1 for iron and 0.24 mg L-1 for manganese. The determination of both parameters was made in 6 minutes, in triplicate. The application to monitor laboratory scale soil core columns (LSSCs), as a simulation of the soil leaching process, proved its efficiency to assess potential contamination of ground waters. Iron and manganese contents were effectively analysed in two different scenarios to mimic the leaching process with rainwater and fertilizer.


Asunto(s)
Agua Subterránea , Manganeso , Quelantes/análisis , Hierro/análisis , Manganeso/análisis , Suelo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA