Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Diabet Med ; : e15384, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38923618

RESUMEN

AIMS: In tackling rising diabetes-related emergencies, the need to understand and address emergency service usage by people with type 1 diabetes is vital. This review aimed to quantify current trends in presentations for type 1 diabetes-related emergencies and identify public health strategies that reduce the frequency of diabetes-related emergencies and improve glycaemic management. METHODS: Medline (OVID), Cochrane and CINAHL were searched for studies published between 2000 and 2023, focusing on people with type 1 diabetes, severe hypoglycaemia and/or diabetic ketoacidosis, and ambulance and/or emergency department usage. There were 1313 papers identified, with 37 publications meeting review criteria. RESULTS: The incidence of type 1 diabetes-related emergencies varied from 2.4 to 14.6% over one year for hypoglycaemic episodes, and between 0.07 and 11.8 events per 100 person-years for hyperglycaemic episodes. Notably, our findings revealed that ongoing diabetes education and the integration of diabetes technology, such as continuous glucose monitoring and insulin pump therapy, significantly reduced the incidence of these emergencies. However, socio-economic disparities posed barriers to accessing these technologies, subsequently shifting the cost to emergency healthcare and highlighting the need for governments to consider subsidising these technologies as part of preventative measures. CONCLUSIONS: Improving access to continuous glucose monitoring and insulin pump therapy, in combination with ongoing diabetes education focusing on symptom recognition and early management, will reduce the incidence of diabetes-related emergencies. Concurrent research assessing emergency healthcare usage patterns during the implementation of such measures is essential to ensure these are cost-effective.

2.
J Diabetes Sci Technol ; 18(4): 808-818, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38715259

RESUMEN

The older population is increasing worldwide and up to 30% of older adults have diabetes. Older adults with diabetes are at risk of glucose-related acute and chronic complications. Recently, mostly in type 1 diabetes (T1D), continuous glucose monitoring (CGM) devices have proven beneficial in improving time in range (TIR glucose, 70-180 mg/dL or glucose 3.9-10 mmol/L), glycated hemoglobin (HbA1c), and in lowering hypoglycemia (time below range [TBR] glucose <70 mg/dL or glucose <3.9 mmol/L). The international consensus group formulated CGM glycemic targets relating to older adults with diabetes based on very limited data. Their recommendations, based on expert opinion, were aimed at mitigating hypoglycemia in all older adults. However, older adults with diabetes are a heterogeneous group, ranging from healthy to very complex frail individuals based on chronological, biological, and functional aging. Recent clinical trial and real-world data, mostly from healthy older adults with T1D, demonstrated that older adults often achieve CGM targets, including TIR recommended for non-vulnerable groups, but less often meet the recommended TBR <1%. Existing data also support that hypoglycemia avoidance may be more strongly related to minimization of glucose variability (coefficient of variation [CV]) rather than lower TIR. Very limited data are available for glucose goals in older adults adjusted for the complexity of their health status. Herein, we review the bidirectional associations between glucose and health status in older adults with diabetes; use of diabetes technologies, and their impact on glucose control; discuss current guidelines; and propose a new set of CGM targets for older adults with insulin-treated diabetes that are individualized for health and living status.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Hipoglucemia , Humanos , Anciano , Glucemia/análisis , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemia/epidemiología , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Control Glucémico , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/efectos adversos , Hemoglobina Glucada/análisis , Diabetes Mellitus/sangre , Monitoreo Continuo de Glucosa
3.
J Diabetes Sci Technol ; : 19322968241245627, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613225

RESUMEN

BACKGROUND: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. METHODS: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. RESULTS: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time <70 mg/dL did not differ (HCL 3.8% [2.7, 3.9] vs control 6.5% [4.3, 8.6], P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs -18.5 [-36.5, -4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [-0.8, 3.0], P = .050) responses to hypoglycemia were observed. CONCLUSIONS: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. CLINICAL TRIAL REGISTRATION: ACTRN12617000520336.

4.
JCEM Case Rep ; 2(4): luae051, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38601064

RESUMEN

Primary aldosteronism (PA) is the most common form of secondary hypertension. Accurate subtyping of PA is essential to identify unilateral disease, as adrenalectomy improves outcomes. Subtyping PA requires adrenal vein sampling (AVS), which is technically challenging and results from AVS may not always be conclusive. We present a case of a 37-year-old man with PA whose AVS studies were inconclusive due to apparent bilateral aldosterone suppression (ABAS). As a result, our patient was misdiagnosed as having bilateral PA and medically managed until a repeat AVS showed lateralization to the right adrenal gland. ABAS is an underrecognized phenomenon that may confound the subtyping of PA. We recommend repeating AVS in such cases and discuss strategies to minimize ABAS.

5.
Diabetes Technol Ther ; 26(3): 190-197, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444313

RESUMEN

Aim: To assess the real-world performance of MiniMed™ 780G for Australians with type 1 diabetes (T1D) following advanced hybrid closed loop (AHCL) activation and to evaluate the effect of changing from MiniMed 670/770G to 780G. Methods: We analyzed deidentified Carelink™ continuous glucose monitoring (CGM) data from Australian users from January 2020 to December 2022, including the proportion attaining three major consensus targets: Glucose management indicator (GMI <7.0%), time in range (TIR 70-180 mg/dL >70%), and time below range (TBR 70 mg/dL <4%). Results: Comparing 670/770G users (n = 5676) for mean ± standard deviation 364 ± 244 days with 780G users (n = 3566) for 146 ± 145 days, the latter achieved a higher TIR (72.6% ± 10.6% vs. 67.3% ± 11.4%; P < 0.001), lower time above range (TAR) (25.5% ± 10.9% vs. 30.6% ± 11.7%; P < 0.001), and lower GMI (6.9% ± 0.4% vs. 7.2% ± 0.4%; P < 0.001) without compromising TBR (1.9% ± 1.8% vs. 2.0% ± 1.8%; P = 0.0015). Of 1051 670/770G users transitioning to 780G, TIR increased (70.0% ± 10.7% to 74.0% ± 10.2%; P < 0.001), TAR decreased (28.1% ± 10.9% to 24.0% ± 10.7%; P < 0.001), and TBR was unchanged. The percentage of users attaining all three CGM targets was higher in 780G users (50.1% vs. 29.5%; P < 0.001). CGM metrics were stable at 12 months post-transition. Conclusion: Real-world data from Australia shows that a higher proportion of MiniMed 780G users meet clinical targets for CGM consensus metrics compared to MiniMed 670/770G users and glucose control was sustained over 12 months.


Asunto(s)
Pueblos de Australasia , Automonitorización de la Glucosa Sanguínea , Insulina , Humanos , Australia , Glucemia , Insulina/uso terapéutico , Insulina Regular Humana
6.
J Diabetes Sci Technol ; : 19322968241236771, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38491800

RESUMEN

BACKGROUND: Combining a continuous glucose monitor with an insulin delivery cannula (CGM-IS) could benefit clinical outcomes. We evaluated the feasibility of a single-needle insertion electrochemical investigational CGM-IS (Pacific Diabetes Technologies, Portland, Oregon) in type 1 diabetes adults. METHODS: Following 48 hours run-in using a Medtronic 780G in manual mode with a commercial insulin set, 12 participants commenced insulin delivery using the CGM-IS. A standardized test meal was eaten on the mornings of days 1 and 4. Venous samples were collected every 10 minutes one hour prior to and 15 minutes post-meal for four hours. CGM-IS glucose measurements were post-processed with a single capillary blood calibration during warm-up and benchmarked against YSI. A Dexcom G6 sensor was worn post-consent to study end. RESULTS: Mean absolute relative difference (MARD) for the CGM-IS glucose measurements was 9.2% (484 paired data points). Consensus error grid revealed 88.6% within zone A and 100% in A + B. Mean (SD) % bias was -3.5 (11.7) %. There were 35 paired YSI readings <100 mg/dL cutoff and 449 ≥100 mg/dL with 81.4% within ±15 mg/dL or ±15%, and 89.9% within ±20 mg/dL or ±20%. Two cannula occlusions required discontinuation of insulin delivery: one at 70 hours post insertion and another during the day 4 meal test. Mean (SD) Dexcom glucose measurements during run-in and between meal tests was respectively 161.3 ± 27.3 mg/dL versus 158.0 ± 25.6 mg/dL; P = .39 and corresponding mean total daily insulin delivered by the pump was 58.0 ± 25.4 Units versus 57.1 ± 28.8 Units; P = .47. CONCLUSIONS: Insulin delivery and glucose sensing with the investigational CGM-IS was feasible. Longer duration studies are needed.

7.
J Clin Endocrinol Metab ; 109(8): 1984-1995, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38373265

RESUMEN

CONTEXT: Omnipod DASH Insulin Management System is a tubeless insulin pump that overcomes the physical inconveniences of conventional tubed insulin pump therapy (IPT). OBJECTIVE: We compared treatment satisfaction with Omnipod DASH System to usual care (multiple daily injections [MDIs] or tubed IPT) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from 4 diabetes centers in Australia were randomly assigned in a 1:1 nonblinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension during which all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire "current" (ΔDTQ-current) score at 12 weeks (study end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, and glycemic and device-related outcomes at 12 weeks (study end) and 24 weeks (end extension). RESULTS: Treatment satisfaction improved more in the Omnipod group vs the Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs 0.0 [12.8]; P < .001) at study end. Significantly greater improvements in other PROs and glycated hemoglobin A1c were also observed. Improvements in DTQ-current and other PROs comparing study end and end extension were similar. While percentage in time in range change from baseline did not differ at study end (-2.0 [12.7] %), it was significantly greater at end extension (5.6 [10.9] %; P = .016). CONCLUSION: The Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG that was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Satisfacción del Paciente , Calidad de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/uso terapéutico , Glucemia/análisis , Hemoglobina Glucada/análisis , Resultado del Tratamiento , Australia
8.
J Diabetes Sci Technol ; 18(4): 764-770, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38372246

RESUMEN

BACKGROUND: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. METHODS: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). RESULTS: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference -22.8 [-27.2, -18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms (r = -.954; P = .001), and positively with TAR >250 mg/dL (r = .901; P = .001), TBR < 54 mg/dL (r = .416; P = .001), and glycemic variability (SD [r = .916] and CV [r = .732]; P = .001 for both). CONCLUSIONS: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Insulina/administración & dosificación , Adulto , Masculino , Femenino , Glucemia/análisis , Glucemia/efectos de los fármacos , Hipoglucemiantes/administración & dosificación , Automonitorización de la Glucosa Sanguínea/métodos , Persona de Mediana Edad , Hipoglucemia/inducido químicamente , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemia/epidemiología , Control Glucémico/métodos , Hiperglucemia/sangre , Hiperglucemia/tratamiento farmacológico
9.
J Diabetes Complications ; 38(3): 108702, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38387103

RESUMEN

AIMS: To relate adverse events with glucose correction rates in diabetic ketoacidosis (DKA) using variable rate intravenous insulin-infusions (VRIII). METHODS: Retrospective, observational study in adults with DKA who received insulin infusions between 2012 and 2017 at St Vincent's Hospital, Melbourne. Early correction of hyperglycaemia (<10 mmol/L) was evaluated for association with hypoglycaemia (<4.0 mmol/L), hypokalaemia (potassium <3.3 mmol/L) and clinical outcomes via regression analysis. RESULTS: The study involved 97 patients, with 93 % having type 1 diabetes. The mean age was 38 years, 47 % were women and 35 % were admitted to intensive care. Hypoglycaemia rates during 12 and 24 h of treatment were 6.2 % and 8.2 %, respectively with 58 % of patients recording their first BGL <10 mmol/L within 12 h and 88 % within 24 h. Ketone clearance time averaged at 15.6 h. Hyperglycaemia correction rates to <10 mmol/L were not different in those with/without hypoglycaemia at 12/24 h, in multivariate analysis including admission BGL. Hypokalaemia occurred in 40.2 % of patients and was associated with lower pH but not BGL correction rates. CONCLUSION: The VRIII protocol achieved early hyperglycaemia correction and ketoacidosis reversal with low hypoglycaemia risk. However, high hypokalaemia rates suggest the need for aggressive potassium replacement, especially in markedly acidotic patients.


Asunto(s)
Diabetes Mellitus , Cetoacidosis Diabética , Hiperglucemia , Hipoglucemia , Hipopotasemia , Adulto , Femenino , Humanos , Masculino , Cetoacidosis Diabética/tratamiento farmacológico , Cetoacidosis Diabética/epidemiología , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipopotasemia/inducido químicamente , Hipopotasemia/epidemiología , Insulina/efectos adversos , Insulina Regular Humana , Potasio , Estudios Retrospectivos
10.
Diabetes Technol Ther ; 26(5): 335-340, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38315502

RESUMEN

Older adults with type 1 diabetes may face challenges driving safely. Glucose "above-5-to-drive" is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [interquartile range; IQR 65-72]; diabetes duration 37 years [20-45]) undertook 618 trips (duration 10 min [5-21]). Most trips (n = 535; 87%) were <30 min duration; 9 trips (1.5%) exceeded 90 min and 3 trips (0.5%) exceeded 120 min. Pre-trip continuous glucose monitoring (CGM) was >5.0 mmol/L for 577 trips (93%) and none of these had CGM <3.9 mmol/L during driving (including 8 trips >90 min and 3 trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54 of 71 alerts (76%) were unrelated to hypoglycemia. Our findings support a glucose "above-5-to-drive" recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrant investigation. Clinical trial ACTRN1261900515190.


Asunto(s)
Conducción de Automóvil , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemia , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Anciano , Masculino , Femenino , Glucemia/análisis , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/uso terapéutico , Persona de Mediana Edad
11.
J Diabetes Investig ; 15(5): 594-597, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38366869

RESUMEN

The gold standard for measuring insulin sensitivity (IS) is the hyperinsulinemic-euglycemic clamp, a time, costly, and labor-intensive research tool. A low insulin sensitivity is associated with a complication-risk in type 1 diabetes. Various formulae using clinical data have been developed and correlated with measured IS in type 1 diabetes. We consolidated multiple formulae into an online calculator (bit.ly/estimated-GDR), enabling comparison of IS and its probability of IS <4.45 mg/kg/min (low) or >6.50 mg/kg/min (high), as measured in a validation set of clamps in 104 adults with type 1 diabetes. Insulin sensitivity calculations using different formulae varied significantly, with correlations (R2) ranging 0.005-0.87 with agreement in detecting low and high glucose disposal rates in the range 49-93% and 89-100%, respectively. We demonstrate that although the calculated IS varies between formulae, their interpretation remains consistent. Our free online calculator offers a user-friendly tool for individual IS calculations and also offers efficient batch processing of data for research.


Asunto(s)
Diabetes Mellitus Tipo 1 , Técnica de Clampeo de la Glucosa , Resistencia a la Insulina , Humanos , Diabetes Mellitus Tipo 1/sangre , Femenino , Adulto , Masculino , Glucemia/análisis , Persona de Mediana Edad , Insulina
12.
Diabetes Care ; 47(4): 747-755, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381515

RESUMEN

OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for "Convenience and Efficacy" favored e-AHCL over run-in and all stages. Percent time in range 70-180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (-0.9%, -0.6%, and -0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulinas , Adulto , Humanos , Femenino , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Algoritmos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico
13.
Diabetes Technol Ther ; 26(S3): 84-96, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377316

RESUMEN

The physical and psychological benefits of exercise are particularly pertinent to people with type 1 diabetes (T1D). The variability in subcutaneous insulin absorption and the delay in offset and onset in glucose lowering action impose limitations, given the rapidly varying insulin requirements with exercise. Simultaneously, there are challenges to glucose monitoring. Consequently, those with T1D are less likely to exercise because of concerns regarding glucose instability. While glucose control with exercise can be enhanced using automated insulin delivery (AID), all commercially available AID systems remain limited by the pharmacokinetics of subcutaneous insulin delivery. Although glycemic responses may vary with exercises of differing intensities and durations, the principles providing the foundation for guidelines include minimization of insulin on board before exercise commencement, judicious and timely carbohydrate supplementation, and when possible, a reduction in insulin delivered in anticipation of planned exercise. There is an increasing body of evidence in support of superior glucose control with AID over manual insulin dosing in people in T1D who wish to exercise. The MiniMed™ 780G AID system varies basal insulin delivery with superimposed automated correction boluses. It incorporates a temporary (elevated glucose) target of 8.3 mmol/L (150 mg/dL) and when it is functioning, the autocorrection boluses are stopped. As the device has recently become commercially available, there are limited data assessing glucose control with the MiniMed™ 780G under exercise conditions. Importantly, when exercise was planned and implemented within consensus guidelines, %time in range and %time below range targets were met. A practical approach to exercising with the device is provided with illustrative case studies. While there are limitations to spontaneity imposed on any AID device due to the pharmacokinetics associated with the subcutaneous delivery of current insulin formulations, the MiniMed™ 780G system provides people with T1D an excellent option for exercising safely if the appropriate strategies are implemented.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Glucemia , Automonitorización de la Glucosa Sanguínea , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
14.
Diabetes Res Clin Pract ; 208: 111123, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309532

RESUMEN

AIMS: Understanding the lived experience of using a tubeless insulin pump and how this differs compared to usual care (tubed insulin pump therapy (IPT) vs multiple daily injections (MDI)). METHODS: Interviews were conducted after 12-weeks of using the Omnipod DASH Insulin Management System (Insulet, Acton, MA) and analysed using thematic analysis. RESULTS: Fifty-eight adults (35 female; mean age 42;SD 13 years; 35 previous MDI) were interviewed. Most (84 %) wanted to continue using the device. Experiences fit two themes: 1. Taking back control of my diabetes: many previous MDI users perceived improved glycaemic control, explained by more "nuanced" control, with some reporting positive effects during exercise and sleep. Many previous MDI and IPT users endorsed positive experiences in concealing or disclosing their diabetes to others. However, some previous MDI users reported negative psychosocial experiences due to feeling continuously "attached" to their diabetes. 2. Barriers and facilitators of device acceptability: both MDI and IPT users cited wearability, alarms and the financial cost impacted their choice to continue device use. IPT users reported positive wearability experiences. CONCLUSIONS: The tubeless pump improved diabetes management perceptions for both MDI and tubed pump users. However, participants' prior glucose management affected perceptions of its advantages and disadvantages.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Hipoglucemiantes/uso terapéutico , Australia , Insulina/uso terapéutico , Inyecciones , Sistemas de Infusión de Insulina , Glucemia
16.
Diabet Med ; 41(3): e15195, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37562414

RESUMEN

AIMS: To examine the psychometric properties of the Diabetes Management Experiences Questionnaire (DME-Q). Adapted from the validated Glucose Monitoring Experiences Questionnaire, the DME-Q captures satisfaction with diabetes management irrespective of treatment modalities. METHODS: The DME-Q was completed by adults with type 1 diabetes as part of a randomized controlled trial comparing hybrid closed loop (HCL) to standard therapy. Most psychometric properties were examined with pre-randomization data (n = 149); responsiveness was examined using baseline and 26-week follow-up data (n = 120). RESULTS: Pre-randomization, participants' mean age was 44 ± 12 years, 52% were women. HbA1c was 61 ± 11 mmol/mol (7.8 ± 1.0%), diabetes duration was 24 ± 12 years and 47% used an insulin pump prior to the trial. A forced three-factor analysis revealed three expected domains, that is, 'Convenience', 'Effectiveness' and 'Intrusiveness', and a forced one-factor solution was also satisfactory. Internal consistency reliability was strong for the three subscales ( α range = 0.74-0.84) and 'Total satisfaction' ( α = 0.85). Convergent validity was demonstrated with moderate correlations between DME-Q 'Total satisfaction' and diabetes distress (PAID: rs = -0.57) and treatment satisfaction (DTSQ; rs = 0.58). Divergent validity was demonstrated with a weak correlation with prospective/retrospective memory (PRMQ: rs = -0.16 and - 0.13 respectively). Responsiveness was demonstrated, as participants randomized to HCL had higher 'Effectiveness' and 'Total satisfaction' scores than those randomized to standard therapy. CONCLUSIONS: The 22-item DME-Q is a brief, acceptable, reliable measure with satisfactory structural and construct validity, which is responsive to intervention. The DME-Q is likely to be useful for evaluation of new pharmaceutical agents and technologies in research and clinical settings.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Satisfacción del Paciente , Psicometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estudios Prospectivos , Glucemia , Encuestas y Cuestionarios
17.
J Sleep Res ; : e14106, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38050705

RESUMEN

Hypoglycaemia during sleep is a common and clinically important issue for people living with insulin-treated diabetes. Continuous glucose monitoring devices can help to identify nocturnal hypoglycaemia and inform treatment strategies. However, sleep is generally inferred, with diabetes researchers and physicians using a fixed-overnight period as a proxy for sleep-wake status when analysing and interpretating continuous glucose monitoring data. No study to date has validated such an approach with established sleep measures. Continuous glucose monitoring and research-grade actigraphy devices were worn and sleep diaries completed for 2 weeks by 28 older adults (mean age 67 years [SD 5]; 17 (59%) women) with type 1 diabetes. Using continuous glucose monitoring data from a total of 356 nights, fixed-overnight (using the recommended period of 00:00 hours-06:00 hours) and objectively-measured sleep periods were compared. The fixed-overnight period approach missed a median 57 min per night (interquartile range: 49-64) of sleep for each participant, including five continuous glucose monitoring-detected hypoglycaemia episodes during objectively-measured sleep. Twenty-seven participants (96%) had at least 1 night with continuous glucose monitoring time-in-range and time-above-range discrepancies both ≥ 10 percentage points, a clinically significant discrepancy. The utility of fixed-overnight time continuous glucose monitoring as a proxy for sleep-awake continuous glucose monitoring is inadequate as it consistently excludes actual sleep time, obscures glycaemic patterns, and misses sensor hypoglycaemia episodes during sleep. The use of validated measures of sleep to aid interpretation of continuous glucose monitoring data is encouraged.

18.
BMC Health Serv Res ; 23(1): 1377, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066492

RESUMEN

BACKGROUND: Type 2 diabetes mellitus (T2DM) is highly prevalent within the Indigenous Australian community. Novel glucose monitoring technology offers an accurate approach to glycaemic management, providing real-time information on glucose levels and trends. The acceptability and feasibilility of this technology in Indigenous Australians with T2DM has not been investigated. OBJECTIVE: This feasibility phenomenological study aims to understand the experiences of Indigenous Australians with T2DM using flash glucose monitoring (FGM). METHODS: Indigenous Australians with T2DM receiving injectable therapy (n = 8) who used FGM (Abbott Freestyle Libre) for 6-months, as part of a clinical trial, participated in semi-structured interviews. Thematic analysis of the interviews was performed using NVivo12 Plus qualitative data analysis software (QSR International). RESULTS: Six major themes emerged: 1) FGM was highly acceptable to the individual; 2) FGM's convenience was its biggest benefit; 3) data from FGM was a tool to modify lifestyle choices; 4) FGM needed to be complemented with health professional support; 5) FGM can be a tool to engage communities in diabetes management; and 6) cost of the device is a barrier to future use. CONCLUSIONS: Indigenous Australians with T2DM had positive experiences with FGM. This study highlights future steps to ensure likelihood of FGM is acceptable and effective within the wider Indigenous Australian community.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 2 , Humanos , Australia , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/terapia , Estudios de Factibilidad , Proyectos Piloto , Aborigenas Australianos e Isleños del Estrecho de Torres
19.
Pilot Feasibility Stud ; 9(1): 171, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37814352

RESUMEN

BACKGROUND: Insulin pump therapy (IPT) improves glucose control in people with type 1 diabetes (T1D) compared with multiple daily injections (MDI). However, their size, the tethered insulin infusion set, intrusiveness when operating the device and the need to disconnect during showering limit their acceptance to many who may benefit. The Omnipod DASH® Insulin Management System is a small waterproof tubeless device which is wirelessly controlled by a handheld device which may be an acceptable alternative. However, there are no randomised controlled trials focusing on the impact on user perceptions of tubeless insulin pump therapy. This pilot study aims to assess study feasibility and acceptability of patch pump therapy compared with usual care in adults with T1D in Australia to inform power calculations and progression to a large-scale multi-site randomised controlled study. METHODS: A pilot multi-site parallel randomised controlled study will be conducted in sixty-four adults with T1D who are managed on MDI or IPT and self-monitoring with finger-stick blood glucose from four specialist diabetes centres in Victoria, Australia. Following carbohydrate counting education, participants will be randomised to use Omnipod DASH® System (Omnipod group) or continue usual care (usual care group) for 12 weeks, followed by a 12-week extension phase where all participants will use Omnipod DASH® System. The primary outcome measure is feasibility determined by study completion rates with a threshold of 0.80. Acceptability of the intervention (Omnipod DASH® System) will be assessed by the difference in Diabetes Technology Questionnaire 'current' (DTQ-current) score at 12 weeks post-randomisation compared to baseline. Secondary outcomes will include other measures of user acceptance, process outcomes, resource outcomes, participant-centred outcomes, healthcare professional perceptions and glycaemic outcomes. DISCUSSION: This pilot study will provide insights regarding the feasibility of the study design and the first data regarding user acceptance of insulin patch pump technology in Australian T1D adults. We anticipate that this study will provide information informing the design of a larger study evaluating the impact of patch pumps on subjective outcomes that are of significance to the person living with T1D. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ( https://anzctr.org.au/ ) ACTRN12621001195842 (8th September 2021). Please refer to Additional file 1: Appendix 1 for full details.

20.
J Diabetes Complications ; 37(10): 108597, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37659140

RESUMEN

microRNAs (miRs), including miR-142, modulate gene expression and processes implicated in vascular damage and may serve as therapeutic targets and agents, including in Type 1 diabetes (T1D). The project aimed to assess whether miR-142 levels differ between people with and without T1D, and to analyse miR-142 associations with cardiovascular (CVD) risk factors. Intracellular miRs were isolated from whole blood cell pellets using TRIzol-based methodology. In a cross-sectional study in 102 adults cellular miR-142 levels were significantly higher (on unadjusted and adjusted analyses) in 69 adults with T1D relative to 33 non-diabetic subjects: mean ± SD, 3.53 ± 3.66 vs. 1.25 ± 0.78, p < 0.0002, but were not related to HbA1c levels. Further miR-142 research, including longitudinal and intervention studies and basic science are of interest. miR-142 may be valuable in clinical practice for predicting health and as a treatment target.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...