Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 23(9): e13641, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35950259

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. While must is the term to be used in the guidelines, if an entity that adopts the guideline has shall as the preferred term, the AAPM considers that must and shall have the same meaning. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Asunto(s)
Electrones , Oncología por Radiación , Humanos , Fotones , Física , Estados Unidos
2.
J Appl Clin Med Phys ; 23(7): e13633, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35533212

RESUMEN

PURPOSE: To better meet clinical needs and facilitate optimal treatment planning, we added two new electron energy beams (7 and 11 MeV) to two Varian TrueBeam linacs. METHODS: We worked with the vendor to create two additional customized electron energies without hardware modifications. For each beam, we set the bending magnet current and then optimized other beam-specific parameters to achieve depths of 50% ionization (I50 ) of 2.9 cm for 7 MeV and 4.2 cm for the 11 MeV beam with the 15 × 15 cm2 cone at 100 cm source-to-surface distance (SSD) by using an ionization chamber profiler (ICP) with a double-wedge (DW) phantom. Beams were steered and balanced to optimize symmetry with the ICP. After all parameters were set, full commissioning was done including measuring beam profiles, percent depth doses (PDDs), output factors (OFs) at standard, and extended SSDs. Measured data were compared between the two linacs and against the values calculated by our RayStation treatment planning system (TPS) following Medical Physics Practice Guideline 5.a (MPPG 5.a) guidelines. RESULTS: The I50 values initially determined with the ICP/DW agreed with those from a PDD-scanned in-water phantom within 0.2 mm for the 7 and 11 MeV on both linacs. Comparison of the beam characteristics from the two linacs indicated that flatness and symmetry agreed within 0.4%, and point-by-point differences in PDD were within 0.01% ± 0.3% for the 7 MeV and 0.01% ± 0.3% for the 11 MeV. The OF ratios between the two linacs were 1.000 ± 0.007 for the 7 MeV and 1.004 ± 0.007 for the 11 MeV. Agreement between TPS-calculated outputs and measurements were -0.1% ± 1.0% for the 7 MeV and 0.2% ± 0.8% for the 11 MeV. All other parameters met the MPPG 5.a's 3%/3-mm criteria. CONCLUSION: We were able to add two new beam energies with no hardware modifications. Tuning of the new beams was facilitated by the ICP/DW system allowing us to have the procedures done in a few hours and achieve highly consistent results across two linacs. PACS numbers: 87.55.Qr, 87.56.Fc.


Asunto(s)
Electrones , Planificación de la Radioterapia Asistida por Computador , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
3.
J Appl Clin Med Phys ; 22(12): 37-50, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34643323

RESUMEN

A 6 MV flattened beam model for a Varian TrueBeamSTx c-arm treatment delivery system in RayStation, developed and validated at one institution, was implemented and validated at another institution. The only parameter value adjustments were to accommodate machine output at the second institution. Validation followed MPPG 5.a. recommendations, with particular attention paid to IMRT and VMAT deliveries. With this minimal adjustment, the model passed validation across a broad spectrum of treatment plans, measurement devices, and staff who created the test plans and executed the measurements. This work demonstrates the possibility of using a single template model in the same treatment planning system with matched machines in a mixed vendor environment.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica
4.
JCO Glob Oncol ; 6: 1631-1638, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33108232

RESUMEN

PURPOSE: Formal education in the radiation sciences is critical for the safe and effective delivery of radiotherapy. Practices and patterns of radiation sciences education and trainee performance in the radiation sciences are poorly described. This study assesses the current state of radiation sciences education in Africa and evaluates a high-yield, on-site educational program in radiation biology and radiation physics for oncology and radiation therapy trainees in Africa. METHODS: An anonymous survey was distributed to members of the African Organization for Research and Treatment in Cancer Training Interest Group to assess current attitudes and practices toward radiation sciences education. A 2-week, on-site educational course in radiation biology and radiation physics was conducted at the Cancer Diseases Hospital in Lusaka, Zambia. Pre- and postcourse assessments in both disciplines were administered to gauge the effectiveness of an intensive high-yield course in the radiation sciences. RESULTS: Significant deficiencies were identified in radiation sciences education, especially in radiation biology. Lack of expert instructors in radiation biology was reported by half of all respondents and was the major contributing factor to deficient education in the radiation sciences. The educational course resulted in marked improvements in radiation biology assessment scores (median pre- and posttest scores, 27% and 55%, respectively; P < .0001) and radiation physics assessment scores (median pre- and posttest scores, 30% and 57.5%, respectively; P < .0001). CONCLUSION: Radiation sciences education in African oncology training programs is inadequate. International collaboration between expert radiation biology and radiation physics instructors can address this educational deficiency and improve trainee competence in the foundational radiation sciences that is critical for the safe and effective delivery of radiotherapy.


Asunto(s)
Física Sanitaria , Oncología por Radiación , Curriculum , Oncología por Radiación/educación , Radiobiología/educación , Zambia
5.
Int J Radiat Oncol Biol Phys ; 69(4): 1193-8, 2007 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-17967308

RESUMEN

PURPOSE: To plan craniospinal irradiation with "field-in-field" (FIF) homogenization in combination with daily, intrafractional modulation of the field junctions, to minimize the possibility of spinal cord overdose. METHODS AND MATERIALS: Lateral cranial fields and posterior spinal fields were planned using a forward-planned, step-and-shoot FIF technique. Field junctions were automatically modulated and custom-weighted for maximal homogeneity within each treatment fraction. Dose-volume histogram analyses and film dosimetry were used to assess results. RESULTS: Plan inhomogeneity improved with FIF. Planning with daily modulated junction shifts provided consistent dose delivery during each fraction of treatment across the junctions. Modulation minimized the impact of a 5-mm setup error at the junction. Film dosimetry confirmed that no point in the junction exceeded the anticipated dose. CONCLUSIONS: Field-in-field planning and modulated junction shifts improve the homogeneity and consistency of daily dose delivery, simplify treatment, and reduce the impact of setup errors.


Asunto(s)
Irradiación Craneana/métodos , Traumatismos por Radiación/prevención & control , Radioterapia de Intensidad Modulada/métodos , Médula Espinal/efectos de la radiación , Adolescente , Adulto , Fraccionamiento de la Dosis de Radiación , Dosimetría por Película/métodos , Humanos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...