Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 11(1): 4155, 2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33603006

RESUMEN

A time-of-flight Bragg-edge neutron transmission imaging was used to investigate the microstructure and strain distributions in a gear hardened by a newly developed two-step induction-heating method: precursor (Sample 1) and final product (Sample 2). The edge-position and edge-broadening were determined and mapped with high spatial resolution, which enabled us to confirm the two-dimensional distributions of the microstructure and residual strain. A deep hardened layer was made for Sample 1 in which martensite was formed on the entire teeth and the outer peripheral portion of the gear body. Sample 2 was subjected to double induction-hardening, where a tempered martensite was formed as the thermal refined microstructure between a fine-grained martensite at the tooth surface and a ferrite-pearlite microstructure at the core. The relationship between edge-broadening and the Vickers hardness described by a linear equation was employed to derive the elastic residual strain. The residual strain map for Sample 2 revealed that a steep compressive strain was introduced into the fine-grained martensite at the tooth surface by the super rapid induction-heating and quenching process. The reversal of tension was speculated to occur below 2 mm from the tooth tip, and the strain was almost zero in the core region.

2.
Rev Sci Instrum ; 91(4): 043302, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32357693

RESUMEN

The energy-resolved neutron imaging system, RADEN, has been installed at the pulsed neutron source in the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Research Complex. In addition to conventional neutron radiography and tomography, RADEN, the world's first imaging beam-line at a pulsed neutron source, provides three main options for new, quantitative neutron imaging techniques: Bragg-edge imaging to visualize the spatial distribution of crystallographic information, resonance absorption imaging for elemental composition and temperature information, and polarized neutron imaging for magnetic field information. This paper describes the results of characterization studies of the neutronic performance and installed devices at RADEN and shows the results of several demonstration studies for pulsed neutron imaging.

3.
Sci Rep ; 7(1): 15516, 2017 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-29138478

RESUMEN

Neutron diffractometry has been a critical tool for clarifying spin structures. In contrast, little attention has been paid to neutron transmission spectroscopy, even though they are different types of the same phenomenon. Soon, it will be possible to measure the wavelength dependence of transmissions easily using accelerator-driven neutron facilities. Therefore, we have started studying the potential of spectroscopy in magnetism, and in this paper, we report the first observation of a magnetic Bragg dip and Bragg edge in the neutron transmission spectra of a typical spin superstructure; clear antiferromagnetic Bragg dips and Bragg edges are found for a single crystal and powder of nickel oxide, respectively. The obtained results show that transmission spectroscopy is a promising tool for measurements under multi-extreme conditions and for the precise analyses of spin structures, not only in MW-class pulsed spallation source facilities but also in compact neutron source facilities.

4.
J Appl Crystallogr ; 49(Pt 1): 120-127, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26937237

RESUMEN

SENJU is a new single-crystal time-of-flight neutron diffractometer installed at BL18 at the Materials and Life Science Experimental Facility of the Japan Accelerator Research Complex (J-PARC). The diffractometer was designed for precise crystal and magnetic structure analyses under multiple extreme sample environments such as low temperature, high pressure and high magnetic field, and for diffraction measurements of small single crystals down to 0.1 mm3 in volume. SENJU comprises three choppers, an elliptical shape straight supermirror guide, a vacuum sample chamber and 37 scintillator area detectors. The moderator-to-sample distance is 34.8 m, and the sample-to-detector distance is 800 mm. The wavelength of incident neutrons is 0.4-4.4 Š(first frame). Because short-wavelength neutrons are available and the large solid angle around the sample position is covered by the area detectors, a large reciprocal space can be simultaneously measured. Furthermore, the vacuum sample chamber and collimator have been designed to produce a very low background level. Thus, the measurement of a small single crystal is possible. As sample environment devices, a newly developed cryostat with a two-axis (ω and φ axes) goniometer and some extreme environment devices, e.g. a vertical-field magnet, high-temperature furnace and high-pressure cell, are available. The structure analysis of a sub-millimetre size (0.1 mm3) single organic crystal, taurine, and a magnetic structure analysis of the antiferromagnetic phase of MnF2 have been performed. These results demonstrate that SENJU can be a powerful tool to promote materials science research.

5.
Biosci Biotechnol Biochem ; 76(5): 1044-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22738986

RESUMEN

2-Aminoresorcinol is a potent and selective intestinal glucosidase inhibitor. Unlike the majority of glucosidase inhibitors, it shows an uncompetitive mode of inhibition. In this study, we tested the intestinal glucosidase inhibitory activity of various 2-aminoresorcinol derivatives. We found that structural changes, in amino and two phenolic hydroxyl groups had a negative impact on inhibitory activity, but methylation of the phenolic hydroxyl group was found to maintain its activity and replacement of the aromatic ring with an acyl or alkoxy carbonyl group at the 4th position also retained its activity. This enable us to design a molecular probe for further study of the inhibition mechanism of 2-aminoresorcinol.


Asunto(s)
Inhibidores Enzimáticos/síntesis química , Hipoglucemiantes/síntesis química , Sondas Moleculares/síntesis química , Resorcinoles/síntesis química , alfa-Glucosidasas/química , Sitios de Unión , Diseño de Fármacos , Inhibidores de Glicósido Hidrolasas , Humanos , Intestinos/enzimología , Relación Estructura-Actividad , Sacarasa/antagonistas & inhibidores , Sacarasa/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA