Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.526
1.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Article En | MEDLINE | ID: mdl-37671952

A retroreflector array, composed of a cluster of small retroreflectors, is experimentally studied for application to a Michelson-type interferometer system in the fusion plasma experiment. Such a new-type reflector has the potential to be a vital and effective tool at a spatially limited location, such as on the vacuum chamber wall of plasma experimental devices. To investigate the effect of retroreflector array on the reflected beam properties, a tabletop experiment is performed with the retroreflector array composed of 4 mm corner-cube retroreflectors and with a 320-GHz (λ ∼ 0.937 mm) submillimeter wave source. An imaging camera is utilized to measure the submillimeter wave beam profile and is scanned perpendicularly to the beam propagation direction if necessary. The experimental result exhibits a diffraction effect on the reflected beam, resulting in the emergence of discrete peaks on the reflected beam profile, as predicted in the past numerical study; however, the most reflected beam power converges on the one reflected into the incident direction, resulting from a property as a retroreflector. Furthermore, the dependence of the reflected beam on the incident beam angle is characterized while fixing the detector position, and the retroreflection beam intensity is found to vary due to the diffraction effect. Such an undesired variation of beam intensity induced by the diffraction can be suppressed with a focusing lens placed in front of the detector in the practical application to an interferometer.

2.
Clin Exp Nephrol ; 27(12): 1032-1041, 2023 Dec.
Article En | MEDLINE | ID: mdl-37646957

BACKGROUND: In 2020, the Committee of Clinical Practical Guideline for IgA Nephropathy (IgAN) revised the clinical practice guidelines. Herein, we conducted a questionnaire survey to assess the potential discrepancies between clinical practice guidelines and real-world practice in Japan. METHODS: A web-based survey of members of the Japanese Society of Nephrology was conducted between November 15 and December 28, 2021. RESULTS: A total of 217 members (internal physicians: 203, pediatricians: 14) responded to the questionnaire. Of these respondents, 94.0% answered that the clinical practice guidelines were referred to "always" or "often." Approximately 66.4% respondents answered that histological grade (H-Grade) derived from the "Clinical Guidelines for IgA nephropathy in Japan, 3rd version" and the "Oxford classification" were used for pathological classification. Moreover, 73.7% respondents answered that the risk grade (R-grade) derived from the "Clinical Guidelines for IgA nephropathy in Japan, 3rd version" was referred to for risk stratification. The prescription rate of renin-angiotensin system blockers increased based on urinary protein levels (> 1.0 g/day: 88.6%, 0.5-1.0 g/day: 71.0%, < 0.5 g/day: 25.0%). Similarly, the prescription rate of corticosteroids increased according to proteinuria levels (> 1.0 g/day: 77.8%, 0.5-1.0 g/day: 52.8%, < 0.5 g/day: 11.9%). The respondents emphasized on hematuria when using corticosteroids. In cases of hematuria, the indication rate for corticosteroids was higher than in those without hematuria, even if the urinary protein level was 1 g/gCr or less. Few severe infectious diseases or serious deterioration in glycemic control were reported during corticosteroid use. CONCLUSION: Our questionnaire survey revealed real-world aspects of IgAN treatment in Japan.


Glomerulonephritis, IGA , Humans , Glomerulonephritis, IGA/pathology , Hematuria/pathology , Japan , Treatment Outcome , Proteinuria/pathology , Surveys and Questionnaires , Adrenal Cortex Hormones/therapeutic use
3.
Int J Obstet Anesth ; 54: 103648, 2023 05.
Article En | MEDLINE | ID: mdl-36930996

South Africa is classified as a low- and middle-income country, with a complex mixture of resource-rich and resource-limited settings. In the major referral hospitals, the necessary skill level exists for the management of complex challenges. However, this contrasts with the frequently-inadequate skill levels of anaesthesia practitioners in resource-limited environments. In Japan, obstetricians administer anaesthesia for 40% of caesarean deliveries and 80% of labour analgesia. Centralisation of delivery facilities is now occurring and it is expected that obstetric anaesthesiologists will be available 24 h a day in centralised facilities in the future. In China, improvements in women's reproductive, maternal, neonatal, child, and adolescent health are critical government policies. Obstetric anaesthesia, especially labour analgesia, has received unprecedented attention. Chinese obstetric anaesthesiologists are passionate about clinical research, focusing on efficacy, safety, and topical issues. The Latin-American region has different landscapes, people, languages, and cultures, and is one of the world's regions with the most inequality. There are large gaps in research, knowledge, and health services, and the World Federation of Societies of Anaesthesiologists is committed to working with governmental and non-governmental organisations to improve patient care and access to safe anaesthesia. Anaesthesia workforce challenges, exacerbated by coronavirus disease 2019, beset North American healthcare. Pre-existing struggles by governments and decision-makers to improve health care access remain, partly due to unfamiliarity with the role of the anaesthesiologist. In addition to weaknesses in work environments and dated standards of work culture, the work-life balance demanded by new generations of anaesthesiologists must be acknowledged.


Anesthesia, Obstetrical , COVID-19 , Pregnancy , Adolescent , Infant, Newborn , Child , Humans , Female , Latin America , Japan , South Africa , China , North America
5.
Rev Sci Instrum ; 93(11): 113519, 2022 Nov 01.
Article En | MEDLINE | ID: mdl-36461432

A new 320 GHz solid-state source interferometer is installed in the Heliotron J helical device to explore the physics of high-density plasmas (ne > 2-3 × 1019 m-3, typically) realized with advanced fueling techniques. This interferometry system is of the Michelson type and is based on the heterodyne principle, with two independent solid-state sources that can deliver an output power of up to 50 mW. A high time resolution measurement of <1 µs can be derived by tuning the frequency of one source in the frequency range of 312-324 GHz on the new system, which can realize the fluctuation measurement. We successfully measured the line-averaged electron density in high-density plasma experiments. The measured density agreed well with a microwave interferometer measurement using a different viewing chord, demonstrating that the new system can be used for routine diagnostics of electron density in Heliotron J.

6.
Rev Sci Instrum ; 93(11): 113537, 2022 Nov 01.
Article En | MEDLINE | ID: mdl-36461543

The Paα line (1875.13 nm) in the near-infrared (NIR) region was evaluated to apply Stark broadening of the line spectrum to the electron density measurement of the small-pellet ablation cloud in Heliotron J, a medium-sized helical-axis heliotron device. Paα is three-to-four times broader than the visible Hß line (486.13 nm) for the same electron density. Using a portable NIR spectrometer, preliminary proof-of-concept experiments determined the marginal density, below which the broadening was undetectable. The lower detection density limit can be decreased using a narrower entrance slit or a denser grating.

7.
Sci Rep ; 12(1): 14204, 2022 Aug 20.
Article En | MEDLINE | ID: mdl-35987922

Understanding pellet ablation physics is crucial to realizing efficient fueling into a high temperature plasma for the steady state operation of ITER and future fusion reactors. Here we report the first observation of the formation of fluctuation structures in the pellet plasmoid during the pellet ablation process by a fast camera in a medium-sized fusion device, Heliotron J. The fluctuation has a normalized fluctuation level of ~ 15% and propagates around the moving pellet across the magnetic field. By comparing the fluctuation structures with the shape of magnetic field lines calculated with the field line tracing code, we successfully reconstruct the spatio-temporal structure of the fluctuations during the pellet ablation process. The fluctuations are located at the locations displaced toroidally from the pellet and propagate in the cross-field direction around the pellet axis along the field line, indicating a three-dimensional behavior and structure of fluctuations. The fluctuation would be driven by a strong inhomogeneity formed around the pellet and invoke the relaxation of the gradient through a cross-field transport induced by the fluctuations, which could affect the pellet ablation and pellet fueling processes. Such fluctuations can be ubiquitously present at the inhomogeneity formed around a pellet in the pellet ablation process in fusion devices.

8.
J Hosp Infect ; 117: 89-95, 2021 Nov.
Article En | MEDLINE | ID: mdl-34461176

BACKGROUND: Gaseous by-products generated by surgical devices - collectively referred to as 'surgical smoke' - present the hazard of transmitting infective viruses from patients to surgical teams. However, insufficient evidence exists to evaluate and mitigate the risks of SARS-CoV-2 transmission via surgical smoke. AIM: To demonstrate the existence and infectivity of human coronavirus RNA in surgical smoke using a model experiment and to evaluate the possibility of lowering transmission risk by filtration through a surgical mask. METHODS: Pelleted HeLa-ACE2-TMPRSS2 cells infected with human coronavirus were incised by electric scalpel and ultrasonic scalpel, separately. A vacuum system was used to obtain surgical smoke in the form of hydrosol. Reverse transcription-quantitative polymerase chain reaction was used to analyse samples for the presence of viral RNA, and infectivity was determined through plaque assay. Furthermore, a surgical mask was placed centrally in the vacuum line to evaluate its ability to filter viral RNA present in the surgical smoke. FINDINGS: In this model, 1/106 to 1/105 of the viral RNA contained in the incision target was detected in the collected surgical smoke. The virus present in the smoke was unable to induce plaque formation in cultured cells. In addition, filtration of surgical smoke through a surgical mask effectively reduced the amount of viral RNA by at least 99.80%. CONCLUSION: This study demonstrated that surgical smoke may carry human coronavirus, though viral infectivity was considerably reduced. In clinical settings, surgical mask filtration should provide sufficient additional protection against potential coronavirus, including SARS-CoV-2, infection facilitated by surgical smoke.


COVID-19 , Smoke , Humans , Masks , RNA, Viral/genetics , SARS-CoV-2 , Smoke/adverse effects
9.
Rev Sci Instrum ; 92(5): 053519, 2021 May 01.
Article En | MEDLINE | ID: mdl-34243360

We report the development of a new interferometer with two stable, high-power, 320 GHz solid-state sources in Heliotron J. A heterodyne Michelson interferometer optical scheme is employed. Two solid-state oscillators are utilized as sources with a fixed frequency at 320 GHz and frequency tunable of 312-324 GHz. Quasi-optical techniques are used for beam transmission. The beam is elongated in the vertical direction with two off-axis parabolic mirrors and injected into the plasma as a sheet beam for the multi-channel measurement (>5 ch.). Passing through the plasma, the beam is reflected at a retroreflector-array installed at the vacuum chamber wall. The retroreflector-array is a bunch of retroreflector structures, which can suppress the beam refraction caused by plasma without much space inside a vacuum chamber unlike a single retroreflector and can facilitate the system design. The source, detectors, and the retroreflector-array are tested to evaluate their basic performance on a tabletop experiment.

10.
BJS Open ; 5(2)2021 03 05.
Article En | MEDLINE | ID: mdl-33724337

BACKGROUND: RCTs are considered the standard in surgical research, whereas case-matched studies and propensity score matching studies are conducted as an alternative option. Both study designs have been used to investigate the potential superiority of robotic surgery over laparoscopic surgery for rectal cancer. However, no conclusion has been reached regarding whether there are differences in findings according to study design. This study aimed to examine similarities and differences in findings relating to robotic surgery for rectal cancer by study design. METHODS: A comprehensive literature search was conducted using PubMed, Scopus, and Cochrane CENTRAL to identify RCTs, case-matched studies, and cohort studies that compared robotic versus laparoscopic surgery for rectal cancer. Primary outcomes were incidence of postoperative overall complications, incidence of anastomotic leakage, and postoperative mortality. Meta-analyses were performed for each study design using a random-effects model. RESULTS: Fifty-nine articles were identified and reviewed. No differences were observed in incidence of anastomotic leakage, mortality, rate of positive circumferential resection margins, conversion rate, and duration of operation by study design. With respect to the incidence of postoperative overall complications and duration of hospital stay, the superiority of robotic surgery was most evident in cohort studies (risk ratio (RR) 0.83, 95 per cent c.i. 0.74 to 0.92, P < 0.001; mean difference (MD) -1.11 (95 per cent c.i. -1.86 to -0.36) days, P = 0.004; respectively), and least evident in RCTs (RR 1.12, 0.91 to 1.38, P = 0.27; MD -0.28 (-1.44 to 0.88) days, P = 0.64; respectively). CONCLUSION: Results of case-matched studies were often similar to those of RCTs in terms of outcomes of robotic surgery for rectal cancer. However, case-matched studies occasionally overestimated the effects of interventions compared with RCTs.


Length of Stay/statistics & numerical data , Postoperative Complications/epidemiology , Rectal Neoplasms/surgery , Research Design , Robotic Surgical Procedures , Case-Control Studies , Cohort Studies , Humans , Randomized Controlled Trials as Topic , Treatment Outcome
12.
Occup Med (Lond) ; 70(8): 564-569, 2020 Dec 12.
Article En | MEDLINE | ID: mdl-33180107

BACKGROUND: Presenteeism is an important factor in workers' health. However, few studies have examined how variables such as socio-economic status, health status, workplace status and health literacy correlate with and affect presenteeism. AIMS: To assess the correlates of presenteeism with a focus on health-related factors, work-related factors and health literacy. METHODS: We conducted a cross-sectional study of 2914 Japanese workers from one company. We used a self-administered questionnaire to assess socio-demographic characteristics, health status, work environment, presenteeism and health literacy. RESULTS: Forty-one per cent of participants were under 40 years of age and 70% were male. We found that 59% of the participants were at high risk of presenteeism. Presenteeism was associated with sex, age, household income, marital status, health-related factors (i.e. self-rated health status, dietary choices, exercise habits), work-related factors (i.e. workplace support, job demands, job control) and health literacy. Logistic regression analyses indicated that presenteeism was associated with self-rated health status, overtime hours, workplace support, job demands, job control and health literacy after adjusting for sex, age and income. CONCLUSIONS: Health-related factors, work-related factors and health literacy are all associated with presenteeism. Improving the workplace environment, especially factors such as overtime working hours, workplace support, job demands and job control, and increasing health literacy may reduce presenteeism among general office workers.


Health Literacy , Occupational Health , Presenteeism , Aged , Cross-Sectional Studies , Humans , Male , Surveys and Questionnaires , Workplace
13.
Sci Rep ; 10(1): 5, 2020 01 08.
Article En | MEDLINE | ID: mdl-31913300

When realising future fusion reactors, their stationary burning must be maintained and the heat flux to the divertor must be reduced. This essentially requires a stationary internal transport barrier (ITB) plasma with a fast control system. However, the time scale for determining the position of the foot point of an ITB is not clearly understood even though its understanding is indispensable for fast profile control. In this study, the foot point of the electron ITB (eITB) was observed to be reformed at the vicinity of a magnetic island when the island started to form. In addition, the enhanced confinement region was observed to expand during the eITB formation according to the radial movement of the magnetic island toward the outer region. Compared to the time scales of the local heat transport, the faster time scales of the movement of the eITB foot point immediately after island formation (~0.5 ms) suggest the importance of the magnetic island for plasma profile control to maintain stationary burning.

14.
J Obstet Gynaecol ; 39(3): 434-436, 2019 Apr.
Article En | MEDLINE | ID: mdl-30744435

Approximately 15% of couples are infertile, with half of these cases being due to a male factor. Testis-specific cytoplasmic poly(A) polymerase beta (PAPOLB) is known to be critical for spermatogenesis. In mice, the loss of function of the Papolb gene results in the arrest of spermiogenesis and in male infertility. To analyse the role of the PAPOLB gene in human male infertility, this study investigated the relevance of this gene to human Sertoli-cell-only syndrome (SCOS) with azoospermia. Mutation analysis of the PAPOLB coding region was performed on 139 Japanese patients by PCR and direct sequence analysis. No critical mutations directly causing SCOS were detected, but three single-nucleotide polymorphisms (SNPs; SNP1 (c1101C > T), SNP2 (c1347T > C) and SNP3 (c1903C > A)) were found in the coding region. However, there were no significant associations in the allelic and genotypic distributions of these three SNPs between the SCOS and control groups (p>.05). This study suggests a lack of association of PAPOLB with azoospermia due to SCOS in humans.


Azoospermia/etiology , Sertoli Cell-Only Syndrome/complications , Animals , Asian People , Azoospermia/genetics , Case-Control Studies , DNA Polymerase beta , Humans , Japan , Male , Mice , Polymorphism, Single Nucleotide , Retrospective Studies , Sertoli Cell-Only Syndrome/genetics
15.
Pharmazie ; 74(2): 120-124, 2019 02 01.
Article En | MEDLINE | ID: mdl-30782263

Aim of the study: Here, we investigated the risk factors for decreased teicoplanin plasma trough concentrations relative to the initial dosing in critically ill patients. Patients and methods: Data obtained from 80 eligible critically ill patients who received intravenous teicoplanin were retrospectively analyzed. Risk factors for decreases in teicoplanin trough concentrations 72 h after administration of teicoplanin of more than 30% relative to predicted concentrations based on initial dosing setting were identified by logistic regression analysis. Results: Although prediction trough concentration and total dose of two days no significant differences were seen between the variation group and the non-variation group, actual trough concentration was significantly different between two groups (19.9±5.6 µg/ml vs 10.3±2.2 µg/ml, p < 0.001). In multivariate analysis, serum albumin ≤ 2.2 mg/dl (odds ratio [OR] = 3.003, 95% CI 1.072-8.408; p = 0.036) and SOFA score ≥ 9 (OR = 3.498, 95% CI 1.171-10.450; p = 0.025) were significant risk factors for decreased teicoplanin plasma trough concentrations. Conclusion: In critically ill patients, high SOFA score and low serum albumin were risk factors for decreased teicoplanin plasma trough concentration during initial dosing.


Anti-Bacterial Agents/blood , Infections/blood , Infections/drug therapy , Teicoplanin/blood , Administration, Intravenous , Adolescent , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/administration & dosage , Critical Illness , Female , Humans , Infant , Male , Middle Aged , Retrospective Studies , Risk Factors , Teicoplanin/administration & dosage , Young Adult
16.
Rev Sci Instrum ; 89(10): 10D129, 2018 Oct.
Article En | MEDLINE | ID: mdl-30399947

A simple near-infrared (NIR) spectrometer with a wavelength range of 898-2130 nm has recently been applied to diagnose Heliotron J plasmas. It adopts a symmetrical crossed Czerny-Turner mount equipped with a thermoelectrically cooled 512 channel InGaAs linear sensor. Reciprocal linear dispersion was deduced to 96.37 nm/mm at the center of the detector. External filters can be inserted into the path of the collection optics to reject second-order spectra, as needed. Absolute intensity calibration was performed together with a visible spectrometer using a tungsten halogen lamp, and the effect of the transmittance fringe in the visible region of the applied long-pass filter on the NIR calibration was investigated. The intended application of the NIR spectrometer includes extending the wavelength region of a spectral monitor to less contaminated regions for Heliotron J plasma studies. In preliminary measurements, we observed the Paschen series for the hydrogen pellet injection plasma and two atomic helium lines, i.e., 2S-2P singlet and triplet lines, in helium gas puffing experiments. A continuum spectrum in this regime that is attributable to black-body radiation from hot spots on the plasma-facing components was identified. In addition, this may also be used to monitor background radiation in the YAG-Thomson scattering signals near 1064 nm.

19.
Radiat Prot Dosimetry ; 181(3): 261-268, 2018 Oct 01.
Article En | MEDLINE | ID: mdl-29462479

The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.


Abdomen/radiation effects , Pelvis/radiation effects , Phantoms, Imaging , Radiation Monitoring , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Humans , Radiation Dosage , Radiography, Thoracic
...