Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38710782

RESUMEN

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Aorta/diagnóstico por imagen , Aorta/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Estudios Retrospectivos
2.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451154

RESUMEN

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Ecocardiografía Transesofágica , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia
3.
Comput Biol Med ; 163: 107147, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37329622

RESUMEN

Accurate planning of transcatheter aortic valve implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly performed through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performs AR segmentation and model 2 identifies the aortic annulus and sinotubular junction (STJ) contours. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. Results were validated against manual measurements of 178 TAVI candidates. The trained CNNs segmented the AR, annulus, and STJ effectively, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 0.73 mm and 0.99 mm for the annulus and STJ, respectively. Automatic measurements were in good agreement with manual annotations, yielding annulus diameters that differed by 0.52 [-2.96, 4.00] mm (bias and 95% limits of agreement for manual minus algorithm). Evaluating the area-derived diameter, bias, and limits of agreement were 0.07 [-0.25, 0.39] mm. STJ and sinuses diameters computed by the automatic method yielded differences of 0.16 [-2.03, 2.34] and 0.1 [-2.93, 3.13] mm, respectively. The proposed tool is a fully automatic solution to quantify morphological biomarkers for pre-TAVI planning. The method was validated against manual annotation from clinical experts and showed to be quick and effective in assessing AR anatomy, with potential for time and cost savings.


Asunto(s)
Estenosis de la Válvula Aórtica , Aprendizaje Profundo , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Aorta Torácica , Tomografía Computarizada por Rayos X/métodos
4.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34939726

RESUMEN

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Derecha , Ventrículos Cardíacos , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Resultado del Tratamiento , Función Ventricular Derecha
5.
Rev Cardiovasc Med ; 23(11): 358, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39076178

RESUMEN

Background: The impact of nodular calcifications in left ventricular outlow tract (LVOT) and aortic annulus on the procedural outcome of transcatheter aortic valve implantation (TAVI) with new-generation devices is yet to be elucidated. Similarly, computational simulations may provide a novel insight into the biomechanical features of TAVI devices and their interaction with nodular calcifications. Methods: This retrospective single-center study included 232 patients submitted to TAVI with Evolut-R (53.4%), Portico (33.6%) and Lotus (13.0%) devices with available preoperative computed tomography (CT) angiography and evidence of nodular calcifications in aortic annulus and/or LVOT. Calcification severity was defined ≥ moderate in presence of at least two nodules or one nodule ≤ 5 mm. Three virtual simulation models of aortic root presenting a nodular calcification of increasing size were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. Results: At least moderate calcifications were found in 123 (53.0%) patients, with no sex differences. Among the ≥ moderate calcification group, lower device success rate was evident (87.8% vs. 95.4%; p = 0.039). Higher rates of ≥ moderate paravalvular leak (PVL) (11.4% vs. 3.7%; p = 0.028) and vascular complications (9.8% vs. 2.8%; p = 0.030) were also observed. Among the Evolut-R group, higher rates of at ≥ moderate PVL (12.1%) were observed compared to Portico (3.8%; p = 0.045) and Lotus (0.0%; p = 0.044) groups. Calcification of both annulus and LVOT (odds ratio [OR] 0.105; p = 0.023) were independent predictors of device success. On computational simulations, Portico exhibited homogeneous stress distribution by increasing calfications and overall a larger paravalvular orifice areas compared to Evolut-R and Lotus. Evolut-R showed higher values of average stress than Portico, although with a more dishomogeneous distribution leading to greater paravalvular orifice areas by severe calcifications. Lotus showed overall small paravalvular orifice areas, with no significant increase across the three models. Conclusions: At least moderate nodular calcifications in the annulus/LVOT region significantly affected TAVI outcome, as they were independent predictors of device success. Lotus and Portico seemed to perform better than Evolut-R as for device success and ≥ moderate PVL. Computational simulations revealed unique biomechanical features of the investigated devices in terms of stent compliance and radial force.

6.
JACC Case Rep ; 3(4): 678-681, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34317602

RESUMEN

Redo transcatheter aortic valve replacement (TAVR) may pose the risk of coronary flow obstruction. We report 2 cases of severe TAVR regurgitation due to different physiopathological mechanisms in which TAVR-in-TAVR could be at high risk for sinus sequestration. Both cases were successfully treated by in-series implantation of a second transcatheter heart valve, thus avoiding sinus sequestration. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA