Adv Lab Med ; 5(2): 189-196, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939205

RESUMEN

Objectives: Despite clinical guidelines do not recommend the use of point-of-care testing (POCT) glucometers for diagnostic purposes yet, the analytical performance is continuously improving. Thus, we evaluate the technical accuracy and clinical concordance of POCT glucometers during an oral glucose tolerance test (OGTT) in children for prediabetes and diabetes diagnosis in a comparison study. Methods: Pediatric patients with an OGTT indication who attended the Diabetes Unit between December 2020 and September 2021 were recruited for this prospective observational study. During the functional test, glycaemia was immediately measured in venous blood using two glucometers (unconnected and connected) and sent to the central laboratory. Results: The study included 98 patients. There was a high correlation between the glucometers and the central laboratory (Pearson correlation coefficient=0.912 and 0.950, for unconnected and connected glucometer, respectively). The median OGTT turnaround time (TAT) was significantly decreased (connected glucometer: 2.02 h [interquartile range, 2.00-2.07], central laboratory: 11.63 h [6.09-25.80]), with similar overall cost. The diagnostic concordance between connected glucometer and the central laboratory was 71.1 % (95 % confidence interval (CI) 61.5-79.2). The clinical decision would have been the same in the 92.8 % of the cases, but treatment would have not been indicated in 4 patients (4.1 %). Conclusions: POCT glucometers have demonstrated a high correlation and an acceptable diagnostic concordance with the central laboratory during an OGTT, as well the connected device offers a significant decrease in TAT, without increasing costs. However, as severe clinical impact could happen, POCT glucometers may not be used for diagnosis yet.

4.
Adv Lab Med ; 4(1): 105-119, 2023 Apr.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37359900

RESUMEN

Objectives: Diabetes mellitus intensify the risks and complications related to COVID-19 infection. A major effect of the pandemic has been a drastic reduction of in-person visits. The aim of this study was to evaluate the impact of the COVID-19 pandemic on HbA1c management and results among pediatric and adult outpatients with diabetes, considering the laboratory and point-of-care testing (POCT) HbA1c measurements. Methods: Observational retrospective study including patients from pediatric and adult diabetes units was conducted. HbA1c results obtained in the laboratory and POCT over 3 years (2019-2021) were collected from the laboratory information system. Results: After the lockdown, the number of HbA1c plummeted. Children returned soon to routine clinical practice. The number of HbA1c increased gradually in adults, especially in POCT. Globally, HbA1c results were lower in children compared with adults (p<0.001). HbA1c values in children (p<0.001) and adults (p=0.002) decreased between pre-pandemic and post-pandemic periods, though lower than the HbA1c reference change value. The percentage of HbA1c results above 8% remained stable during the study period. Conclusions: Continuous glucose monitoring and a telemedicine have been crucial, even allowing for improvements in HbA1c results. During the lockdown, patients with better metabolic control were managed in the laboratory whereas patients with poorer control or a severe clinical situation were attended in diabetes units by POCT. Adults returned to pre-pandemic management slowly because they were more susceptible to morbidity and mortality due to COVID-19. Coordination among all health professionals has been essential to offering the best management, especially in difficult scenarios such as the COVID-19 pandemic.

5.
Clin Chem Lab Med ; 61(9): 1572-1579, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37267483

RESUMEN

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee on Point-of-Care Testing (C-POCT) supports the use of point-of-care testing (POCT) outside of the hospital setting performed by healthcare professionals without formal laboratory education because of its numerous benefits. However, these benefits are associated with risks that must be managed, to ensure the provision of reliable test results and minimize harm to the patient. Healthcare professionals, local regulatory bodies, accredited laboratories as well as manufacturers should actively be engaged in education, oversight and advice to ensure that the healthcare professional selects the appropriate equipment and is able to analyze, troubleshoot and correctly interpret the point-of-care (POC) test results.


Asunto(s)
Hospitales , Pruebas en el Punto de Atención , Humanos , Consenso , Laboratorios , Atención a la Salud , Sistemas de Atención de Punto
6.
J Clin Pathol ; 76(2): 116-120, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34518360

RESUMEN

AIMS: Hyponatraemia is the most common body fluid disorders but often goes unnoticed. Our laboratory incorporated a standardised procedure to help clinicians detect moderate/severe hyponatraemia. The study aims were to evaluate the outcomes on patient care and clinicians' satisfaction. METHODS: The study, observational and retrospective, included 1839 cases, adult and paediatric patients, with sodium concentration <130 mmol/L. The procedure consisted of interpretative comments in the emergency and core laboratories report and the point-of-care testing blood gas network report. We evaluated hyponatraemia length in two equal periods: before and after the implementation. We conducted a survey addressed to the staff of the clinical settings involved to know their satisfaction. RESULTS: The median hyponatraemia length decreased significantly from 4.95 hours (2.08-16.57) in the first period to 2.17 hours (1.06-5.39) in the second period. The lack of hyponatraemia patients follow-up was significantly less after the procedure implementation. The survey was answered by 92 (60 senior specialists and 32 residents) out of 110 clinicians surveyed. Ninety of them (98%) answered positively. CONCLUSIONS: We have demonstrated the reduction in the time for diagnosing and management by physicians, the higher uniformity in the time required to solve hyponatraemia episodes following our laboratory procedure and the clinicians' satisfaction.


Asunto(s)
Hiponatremia , Adulto , Niño , Humanos , Hiponatremia/diagnóstico , Hiponatremia/terapia , Laboratorios , Estudios Retrospectivos , Sodio
7.
Adv Lab Med ; 3(2): 142-152, 2022 Jun.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37361872

RESUMEN

Point-of-care-testing (POCT) facilitates rapid availability of results that allows prompt clinical decision making. These results must be reliable and the whole process must not compromise its quality. Blood gas analyzers are one of the most used methods for POCT tests in Emergency Departments (ED) and in critical patients. Whole blood is the preferred sample, and we must be aware that hemolysis can occur. These devices cannot detect the presence of hemolysis in the sample, and because of the characteristics of the sample, we cannot visually detect it either. Hemolysis can alter the result of different parameters, including potassium with abnormal high results or masking low levels (hypokalemia) when reporting normal concentrations. Severe hyperkalemia is associated with the risk of potentially fatal cardiac arrhythmia and demands emergency clinical intervention. Hemolysis can be considered the most frequent cause of pseudohyperkalemia (spurious hyperkalemia) or pseudonormokalemia and can be accompanied by a wrong diagnosis and an ensuing inappropriate clinical decision making. A complete review of the potential causes of falsely elevated potassium concentrations in blood is presented in this article. POCT programs properly led and organized by the clinical laboratory can help to prevent errors and their impact on patient care.

8.
EJIFCC ; 32(2): 131-139, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34421481

RESUMEN

ISO 22870 lists specific requirements for the quality and competence of point-of-care testing (POCT), which are intended for medical laboratories in conjunction with ISO 15189. POCT characteristics include the availability of a large number of devices 24 h/day, a variety of analytical methods, clinical settings inside and outside the hospital, and general non-laboratory staff. ISO 22870 accreditation for adequate POCT management therefore poses a challenge for laboratory medicine, which is charged with leading and coordinating POCT with a multidisciplinary committee. La Paz University Hospital has a complex multitest and multisite network that has been accredited since 2017. In our experience, the particularly crucial areas for POCT accreditation are method performance verification, internal and external quality assurance, staff training and competency, and continuous improvement. ISO 22870 and ISO 15189 accreditation have led us to improve numerous areas regarding the total testing process and, consequently, our patients' results.

9.
Aesthetic Plast Surg ; 45(4): 1826-1842, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33616715

RESUMEN

BACKGROUND: Mesenchymal stem cell-based therapy is known to have the potential to induce angiogenesis. However, there are still some limitations regarding their clinical application. Photomodulation/photobiomodulation is non-invasive and non-toxic phototherapy able to stimulate cell viability, proliferation, differentiation, and migration, when the right irradiation parameters are applied. A review of the published articles on human conditioned-by-photobiomodulation mesenchymal cells in an in vitro set up was carried out. Our aim was to describe the studies' results and identify any possible tendency that might highlight the most suitable procedures. METHODS: A search in English of the PubMed database was carried out with the search criteria: photobiomodulation or photoactivation or photomodulation, and mesenchymal cells. All irradiations applied in vitro, on human mesenchymal cells, with wavelengths ranged from 600 to 1000 nm. RESULTS: The search yielded 42 original articles and five reviews. Finally, 37 articles were selected with a total of 43 procedures. Three procedures (7.0%) from 620 to 625 nm; 26 procedures (60.5%) from 625 to 740 nm; 13 procedures (30.2%) from 740 to 1000 nm; and one procedure (2.3%) with combinations of wavelengths. Of the 43 procedures, 14 assessed cell viability (n = 14/43, 32.6%); 34 cell proliferation (n = 34/43, 79.1%); 19 cell differentiation (n = 19/43, 44.2%); and three cell migration (n = 3/43, 7.0%). CONCLUSIONS: Photobiomodulation is a promising technology that can impact on cell viability, differentiation, proliferation, or migration, leading to enhance its regenerative capacity. NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Fototerapia , Trasplante de Células Madre , Animales , Proliferación Celular , Supervivencia Celular , Humanos
10.
Pract Lab Med ; 22: e00188, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33251311

RESUMEN

OBJECTIVE: We aimed to evaluate the results of key performance indicators (KPIs) for a period of over three years, as well as their effectiveness as an improvement tool, to provide information about Point-of-Care Testing (POCT) management system performance and quality assurance. DESIGN AND METHODS: KPIs regarding the global POCT process, extra-analytical phase, quality assurance and staff training and competency were evaluated for blood gases, HbA1c, sweat test and non-connected and connected glucose in an ISO 22870 accredited network. We established the definition of every KPI and its corresponding target. The results of KPIs from all clinical settings were appraised every month during the study period, taking corrective actions when necessary. RESULTS: Annual global results were generally acceptable. However, some clinical areas displayed deviations in specific months. The monitoring of these KPIs allowed us to detect the deviations immediately and identify their causes. These included errors in patient identification, consumables, strips, reagents, analyzers, calibration, internal and external quality control, sample management, connectivity, and operator identification strategy, among others. CONCLUSIONS: The evaluation of these KPIs over time has shown their appropriateness. This set of quality indicators could be a useful tool for laboratory medicine leading POCT networks for better and safer patient care.

11.
Biochem Med (Zagreb) ; 30(3): 030403, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-33071554

RESUMEN

To fight the virus SARS-CoV-2 spread to Europe from China and to give support to the collapsed public health system, the Spanish Health Authorities developed a field hospital located in the facilities of Madrid exhibition centre (IFEMA) to admit and treat patients diagnosed with SARS-CoV-2 infectious disease (COVID-19). The Department of Laboratory Medicine of La Paz University Hospital in Madrid (LMD-HULP) was designated to provide laboratory services. Due to the emergency, the IFEMA field hospital had to be prepared for patient admission in less than 1 week and the laboratory professionals had to collaborate in a multidisciplinary group to assure that resources were available to start on time. The LMD-HULP participated together with the managers in the design of the tests portfolio and the integration of the healthcare information systems (IS) (hospital IS, laboratory IS and POCT management system). Laboratorians developed a strategy to quickly train clinicians and nurses on test requests, sample collection procedures and management/handling of the POCT blood gas analyser both by written materials and training videos. The IFEMA´s preanalytical unit managed 3782 requests, and more than 11,000 samples from March 27th to April 30th. Furthermore, 1151 samples were measured by blood gas analysers. In conclusion, laboratory professionals must be resilient and have to respond timely in emergencies as this pandemic. The lab's personnel selection, design and monitoring indicators to maintain and further improve the quality and value of laboratory services is crucial to support medical decision making and provide better patient care.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Unidades Móviles de Salud/organización & administración , Pandemias , Neumonía Viral , COVID-19 , Ciudades , Sistemas de Información en Laboratorio Clínico/organización & administración , Infecciones por Coronavirus/epidemiología , Atención a la Salud , Necesidades y Demandas de Servicios de Salud , Capacidad de Camas en Hospitales , Sistemas de Información en Hospital/organización & administración , Hospitales Universitarios/organización & administración , Humanos , Laboratorios de Hospital/organización & administración , Personal de Hospital/educación , Neumonía Viral/epidemiología , Pruebas en el Punto de Atención/organización & administración , Garantía de la Calidad de Atención de Salud/organización & administración , SARS-CoV-2 , España , Manejo de Especímenes
12.
PLoS One ; 13(4): e0193257, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29617365

RESUMEN

Inhibition of the phospholipid phosphatase and tumor suppressor PTEN leads to excessive polarized cell growth during directed cell migration and neurite outgrowth. These processes require the precise regulation of both the actin and microtubule cytoskeleton. While PTEN is known to regulate actin dynamics through phospholipid modulation, whether and how PTEN regulates microtubule dynamics is unknown. Here, we show that depletion of PTEN leads to elevated levels of stable and post-translationally modified (detyrosinated) microtubules in fibroblasts and developing neurons. Further, PTEN depletion enhanced axon outgrowth, which was rescued by reducing the level of detyrosinated microtubules. These data demonstrate a novel role of PTEN in regulating the microtubule cytoskeleton. They further show a novel function of detyrosinated microtubules in axon outgrowth. Specifically, PTEN suppresses axon outgrowth by down-regulating the level of detyrosinated microtubules. Our results suggest that PTEN's role in preventing excessive cell growth in cancerous and neurodevelopmental phenotypes is partially exerted by stabilization and detyrosination of the microtubule cytoskeleton.


Asunto(s)
Microtúbulos/metabolismo , Proyección Neuronal , Neuronas/citología , Fosfohidrolasa PTEN/metabolismo , Tirosina/metabolismo , Animales , Axones/metabolismo , Regulación hacia Abajo , Fibroblastos/citología , Fibroblastos/metabolismo , Ratones , Células 3T3 NIH , Neuronas/metabolismo
13.
Clin Chem Lab Med ; 53(12): 1903-10, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26053009

RESUMEN

The ongoing Ebola virus outbreak in several countries in West Africa was considered by the World Health Organisation (WHO) as a public health emergency of international concern. Healthcare providers must be prepared by organising specific procedures in our hospitals based on recommendations from national and international healthcare organisations. Two aims should be considered: appropriate medical care for patients with suspected or confirmed disease must be ensured, as must measures to prevent transmission to healthcare workers. The clinical laboratory plays an important role and must define and establish its own procedures in accordance with clinicians and integrated into those of the institution, starting with the definition of the organisation model in the laboratory to achieve those goals. In this review we present our experience based on the care of three patients with confirmed cases. We hope it will help other colleagues to plan for Ebola.


Asunto(s)
Técnicas de Laboratorio Clínico , Atención a la Salud/normas , Fiebre Hemorrágica Ebola/diagnóstico , Fiebre Hemorrágica Ebola/terapia , Atención a la Salud/métodos , Hospitales/normas , Humanos , España
14.
Brain Res ; 1611: 84-92, 2015 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-25779040

RESUMEN

In neuronal cultures, glycogen synthase kinase 3(GSK3) is truncated at the N-terminal end by calpain downstream of activated glutamate receptors. However, the in vivo biological significance of that truncation has not been explored. In an attempt to elucidate if GSK3 truncation has a pathophysiological relevance, we have used intraperitoneal injections of kainic acid (KA) in rats and intra-amygdala KA microinjections in mice as in vivo models of excitotoxicity. Spectrin cleavage analyzed by immunohistochemistry was observed in the CA1 hippocampal field in KA-intraperitoneal treated rats while the CA3 region was the hippocampal area affected after intra-amygdala KA microinjections. GSK3ß immunofluorescence did not colocalize with truncated spectrin in both treatments using an antibody that recognize the N-terminal end of GSK3ß. Thus, those neurons which are spectrin-positive do not show GSK3ß immunolabelling. To study GSK3ß truncation in vitro, we exposed organotypic hippocampal slices and cultured cortical neurons to KA leading to the truncation of GSK3 and we found that truncation was blocked by the calpain inhibitor calpeptin. These data suggest a relationship between N-terminal GSK3ß truncation and excitotoxicity. Overall, our data reinforces the important relationship between glutamate receptors and GSK3 and their role in neurodegenerative processes in which excitotoxicity is involved.


Asunto(s)
Agonistas de Aminoácidos Excitadores/toxicidad , Glucógeno Sintasa Quinasa 3/metabolismo , Hipocampo/enzimología , Ácido Kaínico/toxicidad , Neuronas/enzimología , Amígdala del Cerebelo/efectos de los fármacos , Animales , Anticuerpos , Células Cultivadas , Modelos Animales de Enfermedad , Glucógeno Sintasa Quinasa 3/inmunología , Glucógeno Sintasa Quinasa 3 beta , Hipocampo/efectos de los fármacos , Masculino , Ratones , Ratones Endogámicos C57BL , Neuronas/efectos de los fármacos , Ratas , Ratas Wistar , Espectrina/metabolismo
15.
Clin Biochem ; 48(6): 412-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25562184

RESUMEN

INTRODUCTION: Arterial blood gas analysis is relevant in chronic obstructive pulmonary disease (COPD) management. The aim of this study was to evaluate whether the use of a blood gas analyzer in pulmonology departments improves the clinical, operational and economic outcomes when compared with clinical laboratory measurements. PATIENTS AND METHODS: It is an observational prospective study. 112 patients were selected. After specimen collection, the measurement was performed both in pulmonology office as point-of-care and in laboratory. We evaluated clinical outcomes (modification of the indication of long-term oxygen therapy (LTOT) according to results, changes in blood gas analysis results, relationship of the partial pressure of oxygen (PaO2) obtained in the medical visit and velocity of change of the PaO2, influence of total haemoglobin concentration and the change in PaO2), operational outcomes (turnaround time (TAT) from specimen collection to receiving the blood gas analysis report) and economic outcomes (overall cost per process of patient care). RESULTS: There were discrepancies in the indication of LTOT in 13.4% of patients. All parameters showed changes. PaO2 levels showed changes in 2 ways, though they frequently increase over time. The correlation was not good in the other two clinical outcomes. The median TATs in pulmonology office were 1 min versus 79 in laboratory, with 52 min for specimen preparation and transport and 17 min for TAT intralaboratory. The overall cost for the 112 patients in pulmonology office and laboratory was 16,769.89€ and 22,260.97€ respectively. CONCLUSIONS: The use of a blood gas analyzer in a pulmonology office improves clinical, operational and economic outcomes when compared with clinical laboratory.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica/sangre , Adulto , Anciano , Anciano de 80 o más Años , Análisis Químico de la Sangre/economía , Femenino , Costos de la Atención en Salud , Humanos , Masculino , Persona de Mediana Edad , Terapia por Inhalación de Oxígeno/economía , Sistemas de Atención de Punto , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/economía , Enfermedad Pulmonar Obstructiva Crónica/terapia , Resultado del Tratamiento
16.
J Diabetes Sci Technol ; 7(4): 854-62, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23911166

RESUMEN

BACKGROUND: Glucose measurement is the cornerstone of diabetes control. In the hospital setting, the same device and package of test strips (50 or 100 strips) can be used to monitor glucose in several patients, which can increase cross contamination. The objective of our study is to measure bacterial contamination in glucose test strips, comparing results in individual single-use packets (one hospital) versus multi-use vials (two hospitals) in Spain. METHODS: Test strips were collected from five different wards. Each hospital also collected two unopened vials from a single ward as controls. They were sent to a reference laboratory for microbiologic study. A number equal or higher than two colony forming units per strip was considered as a positive result. RESULTS: Out of 423 glucose test strips collected and cultured, 146 were contaminated (34%); only 7% of individually packed strips were contaminated versus 45% of strips packed in multi-use vials, with a high statistical significance (p < .001). CONCLUSIONS: In the strips from multi-use vials, a high contamination rate was found and highly pathogenic organisms were identified, such as methicillin-resistant Staphylococcus epidermidis or Staphylococcus hemolyticus. In contrast, in strips packed individually, there was a much lower contamination rate and no such pathogen organisms were found. Therefore, in the hospital setting, the use of blood glucose test strips in individual packages would be more advantageous (mainly from a clinical point of view, but also from a financial one) than those packed in multi-use vials.


Asunto(s)
Bacterias/aislamiento & purificación , Glucemia/análisis , Embalaje de Medicamentos/métodos , Contaminación de Equipos/estadística & datos numéricos , Tiras Reactivas , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/normas , Infección Hospitalaria/epidemiología , Contaminación de Medicamentos/estadística & datos numéricos , Humanos , Prevalencia , España/epidemiología , Infecciones Estafilocócicas/epidemiología , Staphylococcus epidermidis/aislamiento & purificación , Staphylococcus haemolyticus/aislamiento & purificación
18.
Biochem Med (Zagreb) ; 23(1): 83-95, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23457769

RESUMEN

INTRODUCTION: Technological innovation requires the laboratories to ensure that modifications or incorporations of new techniques do not alter the quality of their results. In an ISO 15189 accredited laboratory, flexible scope accreditation facilitates the inclusion of these changes prior to accreditation body evaluation. A strategy to perform the validation of a biochemistry analyzer in an accredited laboratory having a flexible scope is shown. MATERIALS AND METHODS: A validation procedure including the evaluation of imprecision and bias of two Dimension Vista analysers 1500 was conducted. Comparability of patient results between one of them and the lately replaced Dimension RxL Max was evaluated. All studies followed the respective Clinical and Laboratory Standards Institute (CLSI) protocols. 30 chemistry assays were studied. Coefficients of variation, percent bias and total error were calculated for all tests and biological variation was considered as acceptance criteria. Quality control material and patient samples were used as test materials. Interchangeability of the results was established by processing forty patients' samples in both devices. RESULTS: 27 of the 30 studied parameters met allowable performance criteria. Sodium, chloride and magnesium did not fulfil acceptance criteria. Evidence of interchangeability of patient results was obtained for all parameters except magnesium, NT-proBNP, cTroponin I and C-reactive protein. CONCLUSIONS: A laboratory having a well structured and documented validation procedure can opt to get a flexible scope of accreditation. In addition, performing these activities prior to use on patient samples may evidence technical issues which must be corrected to minimize their impact on patient results.


Asunto(s)
Acreditación/normas , Invenciones/normas , Laboratorios de Hospital/normas , Biomarcadores/sangre , Humanos , Control de Calidad , Centros de Atención Terciaria , Estudios de Validación como Asunto
19.
Neurochem Int ; 59(2): 97-100, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21672591

RESUMEN

Calpain produces a truncation of GSK3ß that removes the N-terminal inhibitory domain. Here we analyze the effect of that truncation on protein-protein interaction. We pulled down GST-tagged proteins in the presence of full length GSK-3ß and calpain-cleaved GSK-3ß. Commercial GSK-3ß was first incubated with calpain for 2.5 min in vitro, and then with GST-tagged proteins in the presence of calpeptin, a synthetic calpain inhibitor. Western blot analyses were performed to determine if there is an interaction between these GST-tagged proteins and truncated GSK-3ß. Using axin GST-tagged, we pulled down the protein in the presence of full length GSK-3ß and calpain-cleaved GSK-3ß. Western blot analyses showed full length GSK-3ß in the pellet as well GSK-3ß cleaved by calpain. Thus axin was able to bind GSK-3ß without the N-terminal end. When the same experiment was carried out with GST-tagged 14-3-3ζ, p53 and PKB, full length GSK-3ß was observed in the pellet, but GSK-3ß truncated by calpain was not pulled down demonstrating that GSK-3ß N-terminal end is necessary to interact with these three proteins. Our data demonstrate that N-terminal end is necessary for 14-3-3ζ, p53 and PKB interaction. However, the interaction of GSK3ß with axin is not altered by calpain. These data support a physiological role for GSK3ß truncation mediated by calpain.


Asunto(s)
Proteínas 14-3-3/metabolismo , Proteína Axina/metabolismo , Calpaína/fisiología , Glucógeno Sintasa Quinasa 3/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo , Proteína p53 Supresora de Tumor/metabolismo , Proteínas 14-3-3/química , Western Blotting , Electroforesis en Gel de Poliacrilamida , Glucógeno Sintasa Quinasa 3/química , Glucógeno Sintasa Quinasa 3 beta , Unión Proteica , Proteínas Proto-Oncogénicas c-akt/química , Proteína p53 Supresora de Tumor/química
20.
Clin Chem Lab Med ; 48(5): 635-9, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20218903

RESUMEN

BACKGROUND: Variability of cytochrome P450 (CYP) in humans is largely related to the pharmacological and toxicological effects of drugs and chemicals. Identification of single nucleotide polymorphisms (SNPs) could be important for knowing their involvement in many drugs metabolism. The goal of this study was to analyze the genotype frequency of 10 SNPs related to mirtazapine metabolism [CYP3A4*17, CYP3A4*18, CYP3A5*3A, CYP1A2*1F, pregnane/steroid X receptor (PXR) (rs3814055, rs38114057, rs3814058) and constitutive androstane receptor (CAR) (rs4073054, rs2307424, rs2502815)]. METHODS: The study was carried out in 207 healthy Spanish volunteers that had participated in phase I clinical trials. Other studies were performed: Hardy-Weinberg equilibrium, haplotype estimation and linkage disequilibrium. RESULTS: No mutation related to CYP3A4*17 and CYP3A4*18 was found. Therefore, we analyzed data for the other eight SNPs. Allele frequencies were in equilibrium with the Hardy-Weinberg equation. Six haplotypes were determined for three PXR SNPs, and four for CAR SNPs. Tests for linkage disequilibrium showed a high association between PXR (rs38114057) and PXR (rs3814058) (p= 0.001), and between the three CAR SNPs (p=0.001), which could be useful for identification of tag SNPs. CONCLUSIONS: In the present study, the genotype frequencies of some SNPs related to mirtazapine metabolism in Spaniards were analyzed and showed that our study population is representative of HapMap European population. The results obtained could be analyzed with pharmacokinetic parameters of mirtazapine to elucidate the genotype-phenotype relationship, the involvement of these SNPs in metabolic reactions, drug interactions, and prediction of treatment response.


Asunto(s)
Citocromo P-450 CYP1A2/genética , Citocromo P-450 CYP3A/genética , Receptores Citoplasmáticos y Nucleares/genética , Receptores de Esteroides/genética , Población Blanca/genética , Adulto , Receptor de Androstano Constitutivo , Femenino , Frecuencia de los Genes , Genotipo , Haplotipos , Humanos , Masculino , Filogenia , Polimorfismo de Nucleótido Simple , Receptor X de Pregnano , Receptores Citoplasmáticos y Nucleares/clasificación , Receptores de Esteroides/clasificación , España , Adulto Joven
SELECCIÓN DE REFERENCIAS