Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
2.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38820195

RESUMEN

CASE: A 34-year-old man was acutely treated with radial head arthroplasty and central band repair following Essex-Lopresti injury. A 38-year-old man presented with chronic longitudinal instability following failed radial head arthroplasty, which was performed for failed fixation. Treatment with revision radial head arthroplasty and central band reconstruction restored longitudinal stability. CONCLUSION: We have a low threshold to repair the central band in acute Essex-Lopresti injury with sufficient evidence of disruption. Nearly all chronic cases require central band reconstruction to restore longitudinal stability. We do not temporarily pin the DRUJ, and distal ulnar shortening is rarely indicated.


Asunto(s)
Inestabilidad de la Articulación , Humanos , Masculino , Adulto , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/etiología , Lesiones de Codo , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Traumatismos de la Muñeca/cirugía , Artroplastia/métodos
3.
J Hand Surg Am ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38597836

RESUMEN

PURPOSE: The distal radioulnar joint (DRUJ) is supported by an array of dynamic and static stabilizers, of which the triangular fibrocartilage complex (TFCC) is the most important, and the distal interosseous ligament is next in importance. The distal oblique band (DOB) is an identifiable component of the distal interosseous ligament, found in a subset of the population. Our objective was to determine the contribution of the DOB to DRUJ stability in the presence of a disrupted TFCC. METHODS: Twenty-three above-elbow specimens were prepared by removing the TFCC and the DRUJ joint capsule, preserving the distal interosseous ligament and the pronator quadratus. Cadavers were stratified into two groups-those with, and those without a DOB. A bone plate and screws were attached to the ulna; then, a transverse load was applied to failure, creating a diastasis between the radius and ulna. RESULTS: The group with a DOB had a mean load at failure of 160.7 ± 46.5 N. The group without a DOB had a mean load at failure of 148.0 ± 26.3 N. Stiffness prior to failure was 16.9 N/mm in the group with a DOB and 12.4 N/mm in the group without a DOB. CONCLUSIONS: The current results indicate that the DOB may not substantially contribute to DRUJ stability in the presence of a disrupted TFCC. CLINICAL RELEVANCE: Stability of the DRUJ after TFCC injury may not be substantially improved by the presence of a DOB. Thus, the clinical importance of DOB reconstruction remains unclear.

6.
Tech Hand Up Extrem Surg ; 27(4): 214-219, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37439145

RESUMEN

We describe a medial approach to the coronoid where the flexor-pronator mass is released from its humeral origin by creating a proximally based tendinous flap. This technique facilitates access to the coronoid, preservation of the medial collateral ligament origin, and repair of the flexor-pronator mass. This approach has utility for all coronoid fracture variations but especially the O'Driscoll anteromedial subtype 3, which includes fractures of the sublime tubercle, the anteromedial facet, and the coronoid tip.


Asunto(s)
Articulación del Codo , Fracturas Óseas , Fracturas del Cúbito , Humanos , Fracturas del Cúbito/cirugía , Articulación del Codo/cirugía , Fracturas Óseas/cirugía , Húmero , Fijación Interna de Fracturas/métodos
7.
Hand (N Y) ; : 15589447231160210, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36959756

RESUMEN

BACKGROUND: Unstable fractures of the base of the middle phalanx are notorious for causing chronic loss of proximal interphalangeal (PIP) joint function, and they remain a challenge for the hand surgeon. We report on a temporary intraoperatively constructed internal joint stabilizer for unstable PIP joint injuries. METHODS: Across 2 institutions, a retrospective chart review was performed for cases with acute presentation of pilon fracture or fracture-dislocation of the base of the middle phalanx which were surgically treated with an internal joint stabilizer. Information collected included time from injury to surgical intervention, time from implantation to device removal, complications, and preoperative and postoperative range of motion. RESULTS: Seven patients met the inclusion criteria with a mean age of 51 (range: 24-72) years and a mean follow-up of 29 (range: 11-72) months. After removal of the fixator, the mean arc of PIP joint motion was 8° to 88° (range: 0°-100°). There were no infections, no hardware loosening or failures, and no revision procedures. CONCLUSION: The current findings are comparable to the results for dynamic external fixators. An internal joint stabilizer for unstable injuries to the base of the middle phalanx provides satisfactory functional outcomes, allows early postoperative motion, and mitigates the routine complications which may arise with external fixation.

8.
J Hand Surg Glob Online ; 4(6): 328-331, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36425377

RESUMEN

Purpose: Distal radius fractures are the most common fractures in adults. Because of the prevalence of these injuries, patients may present with a repeat distal radius fracture on the same wrist through the site of a malunion. We clinically refer to this as an acute on chronic distal radius fracture. In this setting, the restoration of acceptable alignment can be challenging. There is little guidance in the literature for the management of these fractures. We report our experience with acute on chronic distal radius fractures. The secondary fracture plane was used to correct the prior deformity, and the construct was fixated with a fixed angle volar locking plate. Methods: Records of patients with malunion of the distal radius who experienced an acute fracture of the ipsilateral distal radius were reviewed. Inclusion required treatment with open reduction internal fixation using a distal fragment first technique and a volar locking plate through the extended flexor carpi radialis approach. Clinical outcomes and complications were collected. Results: Across 13 patients, the mean follow-up term was 13 months (range, 6-40 months). Radiographic union was noted in all patients. The mean visual analog scale score for pain was 1.8, and the mean Quick Disabilities of the Arm, Shoulder, and Hand score was 21.9. There were no recorded complications. Conclusion: Our results and described technique provide reproducible guidance for the management of acute on chronic distal radius fractures. These cases can be managed using the secondary fracture plane, a distal fragment first technique, and a volar locking plate to correct the preexisting deformity. Type of study/level of evidence: Therapeutic IV.

9.
J Wrist Surg ; 11(3): 219-223, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35837586

RESUMEN

Greater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.

10.
J Wrist Surg ; 11(3): 214-218, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35837594

RESUMEN

The volar rim of the distal radius is the only bony restraint to volar carpal subluxation. Higher loads across the volar rim require stable and rigid fixation to maintain reduction and allow healing while rehabilitation begins. Volar marginal fragments are not amenable to buttressing by fixed angle volar locking plates. Appropriate management of volar marginal fragments comprises two steps-recognition of their presence and rigid anatomical repair. The best opportunity for success in the presence of a volar marginal fragment is its adequate initial treatment. The purpose of this review is to reinforce the importance of a complete preoperative and intraoperative evaluation of distal radius fractures. Volar marginal fragments can easily be overlooked even following initial reduction and fixation. Understanding the relevant anatomy and loading parameters can facilitate intraoperative decisions on approach and fixation, which are integral to achieving optimal clinical outcomes.

11.
Tech Hand Up Extrem Surg ; 26(4): 257-262, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35698306

RESUMEN

It is challenging to restore the clinically acceptable alignment of the distal radius after an acute on chronic fracture or after a secondary fracture occurring after malunion of a primary distal radius fracture. In cases of insignificant primary deformity, restoration to the primary deformity may suffice to obtain a successful clinical result. A borderline acceptable primary radial deformity can be unacceptable after the second injury, resulting in functional disability. If surgery is indicated, the surgeon must contend with both primary and secondary deformities to restore proper distal radius anatomy. We present our technique to correct both primary and secondary distal radius deformities through the new or secondary fracture plane.


Asunto(s)
Fracturas Mal Unidas , Fracturas del Radio , Humanos , Fracturas del Radio/complicaciones , Fracturas del Radio/cirugía , Articulación de la Muñeca , Radio (Anatomía)/cirugía , Fracturas Mal Unidas/cirugía , Resultado del Tratamiento
12.
Instr Course Lect ; 71: 163-181, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35254781

RESUMEN

Distal radius fractures are common. Volar plating is a valuable approach for many fractures. There are also difficult fractures that require careful attention to the exposure and technique for successful volar plating. Classic approaches, such as external fixation with additional percutaneous reduction and pinning or bone graft and fragment-specific fixation, remain valuable especially when volar plating is not applicable. The main objectives are to review the intricacies of volar plating and the use of external fixation with distal radius fractures. This also includes an understanding of the associated injuries that are present with these fractures and the expected outcome of these injuries relative to the distal radius fracture. First, the challenges with volar locked plating as well as many tips and tricks to help with reduction and stabilization of these fractures are reviewed. Second, the benefits and tips and tricks of external fixation are discussed. Finally, the management of common combined injuries with distal radius fractures is reviewed.


Asunto(s)
Fracturas del Radio , Placas Óseas , Fijación de Fractura , Fijación Interna de Fracturas/métodos , Humanos , Fracturas del Radio/cirugía , Resultado del Tratamiento
13.
J Wrist Surg ; 10(6): 536-538, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34877080

RESUMEN

The flexor carpi radialis brevis (FCRB) is an anomalous muscle of the forearm that is only present in 3.5 to 8.6% of the population. In the case of volar plating of distal radius fractures, the FCRB inhibits proper fracture exposure and thus hinders proper reduction. A 78-year-old female presented with right distal radius fracture which necessitated internal fixation. Following mobilization and retraction of the flexor carpi radialis tendon, an anomalous muscle belly was identified as the FCRB. With continued difficulty in exposure and fracture site reduction, resection of the FCRB was performed. The patient was able to return to her activities of daily living without pain and demonstrated no appreciable functional deficit. This case report demonstrates a distal radius fracture where FCRB resection was used, resulting in no detrimental clinical outcomes.

14.
Hand Clin ; 36(4): 407-415, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33040953

RESUMEN

In the forearm, ligaments and joints act in unison to facilitate placement of the hand in 3-dimensional space and transmit loads across the upper extremity. Intricate, effective forearm stabilizers facilitate physiologic motions and restrict abnormal ones. The proximal radioulnar joint, interosseous ligament complex, and distal radioulnar joint work together to ensure the forearm is stable. Each ligament and joint is designed to leverage its biomechanical advantages. Damage destabilizes the synergy of the forearm and results in debilitating injury patterns. Physicians need to understand how all these structures work together to be able to quickly diagnose and treat these forearm injuries.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Articulación del Codo/fisiología , Antebrazo/fisiología , Articulación de la Muñeca/fisiología , Humanos , Luxaciones Articulares/fisiopatología , Luxaciones Articulares/cirugía , Ligamentos Articulares/lesiones , Traumatismos de la Muñeca/fisiopatología , Lesiones de Codo
15.
J Hand Surg Am ; 43(9): 827-832, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29804695

RESUMEN

PURPOSE: Ulnar impaction syndrome is a poorly understood degenerative wrist condition characterized by symptoms of pain thought to be caused by increased loads between the ulnar head and the carpals. Radiographic evaluation often reveals an ulnar-positive wrist. We hypothesize that progressive elongation of the central band of the forearm interosseous ligaments changes the longitudinal radial-ulnar relationships, resulting in an ulnar-positive wrist. The objective of the study was to identify a relationship between the loss of integrity of the forearm interosseous ligaments and increased ulnar variance. METHODS: Six cadaveric human forearms were used to measure displacement of the radius relative to the ulna during axial loading of the lunate fossa of the radius. Radial heights were measured in supination and pronation under a 5-lbF (22-N) preload. Gradual axial loads were applied up to 50 lbF (222N); the resultant axial displacement was measured in supination and pronation. All measurements were evaluated with the interosseous ligament intact and repeated with the central band cut. RESULTS: With an applied 5-lbF preload, cutting the central band increased ulnar variance by 3.02 ± 0.80 mm in supination and by 2.15 ± 0.79 mm in pronation. In supination, when the loads were increased from the 5-lbF preload to 50 lbF, the radius displaced 2.1 times further after the central band was cut (3.00 mm) compared with the group with the intact forearm construct (1.41 mm). In pronation, when the loads were increased from the 5-lbF preload to 50 lbF, the radius displaced 1.8 times further when the central band was cut (2.84 mm) than with the intact forearm construct (1.57 mm). CONCLUSIONS: Because of a parallelogram effect, the radius shifted proximally under a 5-lbF preload, creating an ulnar-positive wrist relationship. Dynamic loading of the forearm after ligament excision resulted in significant additional radial displacement relative to the intact forearm. CLINICAL RELEVANCE: Deficiency in the ligamentous restraints of the central band leads to positive ulnar variance, which could be a factor (among others) that contributes to idiopathic ulnar impaction syndrome.


Asunto(s)
Antebrazo/fisiología , Ligamentos/lesiones , Ligamentos/fisiología , Radio (Anatomía)/fisiología , Cúbito/fisiología , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronación/fisiología , Supinación/fisiología , Soporte de Peso/fisiología
16.
J Shoulder Elbow Surg ; 26(1): 125-132, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27939280

RESUMEN

BACKGROUND: Our primary efficacy objective was to evaluate the effectiveness of the internal joint stabilizer of the elbow (IJS-E) in maintaining concentric location of the elbow during and after removal of the device in the treatment of persistent or recurrent instability after elbow fracture or dislocations, or both. The secondary study objectives were to assess range of motion, Broberg-Morrey functional score, Broberg-Morrey categorical rating, the Disabilities of the Arm, Shoulder and Hand score, and the rate of complications and adverse events after the use of IJS-E. METHODS: Twenty-four patients were studied in a multicenter, nonrandomized, prospective, single-arm study. The IJS-E was used to provide temporary stabilization of the elbow joint and allow a functional range of motion while ligaments and fractures healed. RESULTS: The elbow remained concentrically aligned in 23 of 24 patients. One coronoid-deficient elbow did not maintain concentric reduction. At the last evaluation a minimum of 6 months after device removal, the mean arc of elbow flexion was 119° (range, 80°-150°; standard deviation [SD], 18°), and the mean arc of forearm rotation was 151° (range, 90°-190°; SD, 24°). The mean and median Broberg-Morrey scores were 93 and 97, respectively. Categorically the results were excellent in 14, good in 8, fair in 1, and poor in 1. The mean Disabilities of the Arm, Shoulder and Hand score was 16 (range, 0-68; SD, 18). CONCLUSION: The IJS-E maintains concentric reduction, allows elbow motion, and avoids the inconveniences and pin problems of percutaneous fixation.


Asunto(s)
Articulación del Codo , Fijación Interna de Fracturas/instrumentación , Fracturas Intraarticulares/cirugía , Luxaciones Articulares/cirugía , Inestabilidad de la Articulación/cirugía , Adulto , Anciano , Remoción de Dispositivos , Femenino , Humanos , Fracturas Intraarticulares/complicaciones , Fracturas Intraarticulares/diagnóstico por imagen , Luxaciones Articulares/complicaciones , Luxaciones Articulares/diagnóstico por imagen , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía , Rango del Movimiento Articular , Recuperación de la Función , Resultado del Tratamiento
17.
Tech Hand Up Extrem Surg ; 20(4): 155-160, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27801774

RESUMEN

Locked volar plating is the most common surgical procedure to address distal radius fractures. The extended flexor carpi radialis approach continues to be an excellent method for visualizing distal radius fractures and applying a volar plate. A new understanding of the anatomy allows for better visualization and reduction of the many different distal radius fracture patterns surgeons commonly see. Within the extended flexor carpi radialis approach, we describe the radial septum in further detail including the anatomy which comprises the radial septum triangle. Knowledge of this area allows for better visualization, more anatomic reductions, and fewer complications.


Asunto(s)
Placas Óseas , Disección/métodos , Fijación Interna de Fracturas/métodos , Placa Palmar , Fracturas del Radio/cirugía , Tendones/cirugía , Humanos , Selección de Paciente
18.
J Wrist Surg ; 5(1): 17-21, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26855831

RESUMEN

Background Articular fractures of the distal radius may include a small fragment from the volar margin of the lunate fossa: volar marginal fragments (VMFs); these fragments are prone to loss of fixation and avascular necrosis, and often result in wrist subluxation. We present our experience managing acute and delayed VMFs. The first is treated using a hook plate extension to a volar locking plate and the latter using a volar opening wedge osteotomy to redistribute loads on the remaining articular surface. Materials and Methods We retrospectively reviewed the records of all patients treated at our facility with a hook plate extension for a VMF and for patients treated with a volar opening wedge osteotomy. Medical charts were examined for complications and functional results. Technique A hook plate extension was used to fix the VMF when plate buttressing was insufficient. For patients who presented a collapsed and reabsorbed VMF, a volar opening wedge osteotomy was used to reorient the articular surface, restoring joint stability. Results The hook plate extension was successful in managing 19 of the 21 acute VMFs. The volar opening wedge osteotomy provided concentric reduction and improved pain and motion in all treated patients. Conclusion We demonstrated that hook plate fixation of the VMF is an effective means of fixing the acute VMF and that a volar opening wedge osteotomy can be used to salvage a distal radius fracture with a collapsed VMF.

19.
Clin Biomech (Bristol, Avon) ; 31: 117-22, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26547522

RESUMEN

BACKGROUND: When designing a radial head replacement, the magnitude and direction of forces applied across the proximal radio-ulnar joint (PRUJ) and the radiocapitellar joint must be included. These designs often focus on axial loads transmitted to the radial head by the capitellum; however, the radial head also bears a significant transverse force at the PRUJ. Load transmission by the central band of the interosseous ligament induces a force component in a lateral direction perpendicular to the axis of the limb, which is borne by the articular surfaces of the proximal and distal radio-ulnar joints. The objective of this study is to establish the relationship between distally applied axial forces and proximal transverse reaction forces. METHODS: Five cadaveric, human forearms with intact interosseous membranes were used to measure the magnitude of transversely-directed forces experienced by the radial head during axial loading of the forearm at the lunate fossa. A Mark-10 test stand applied a gradual and continuous axial load on the articular surface of the distal radius. A Mark-10 force gauge measured the resultant transverse force experienced by the radial head in the proximal radioulnar joint. Classical mechanics and static force analysis were applied in order to predict lateral force values that would occur when the interosseous ligament is treated as the major load transmitter between the radius and ulna. FINDINGS: Acquired data show that the radial head bears a force in the transverse direction that averages 18% (SD 3.89%) in magnitude of the axial force applied at the wrist. This figure is in close accordance with the predicted value of 22% that was calculated by way of free-body plotting. INTERPRETATION: Physiologic forearm loading results in a clinically significant transverse force component transmitted through the interosseous ligament complex. The existence of transverse forces in the human forearm may explain clinical problems seen after radial head resection and suggest that radial head implants be designed to sustain substantial transverse forces. LEVEL OF EVIDENCE: Basic science study, anatomical.


Asunto(s)
Antebrazo/fisiología , Radio (Anatomía)/fisiología , Soporte de Peso/fisiología , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico , Cúbito/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA