Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IUCrJ ; 11(Pt 5): 780-791, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39008358

RESUMEN

The advent of serial crystallography has rejuvenated and popularized room-temperature X-ray crystal structure determination. Structures determined at physiological temperature reveal protein flexibility and dynamics. In addition, challenging samples (e.g. large complexes, membrane proteins and viruses) form fragile crystals that are often difficult to harvest for cryo-crystallography. Moreover, a typical serial crystallography experiment requires a large number of microcrystals, mainly achievable through batch crystallization. Many medically relevant samples are expressed in mammalian cell lines, producing a meager quantity of protein that is incompatible with batch crystallization. This can limit the scope of serial crystallography approaches. Direct in situ data collection from a 96-well crystallization plate enables not only the identification of the best diffracting crystallization condition but also the possibility for structure determination under ambient conditions. Here, we describe an in situ serial crystallography (iSX) approach, facilitating direct measurement from crystallization plates mounted on a rapidly exchangeable universal plate holder deployed at a microfocus beamline, ID23-2, at the European Synchrotron Radiation Facility. We applied our iSX approach on a challenging project, autotaxin, a therapeutic target expressed in a stable human cell line, to determine the structure in the lowest-symmetry P1 space group at 3.0 Šresolution. Our in situ data collection strategy provided a complete dataset for structure determination while screening various crystallization conditions. Our data analysis reveals that the iSX approach is highly efficient at a microfocus beamline, improving throughput and demonstrating how crystallization plates can be routinely used as an alternative method of presenting samples for serial crystallography experiments at synchrotrons.


Asunto(s)
Cristalización , Cristalografía por Rayos X/métodos , Humanos , Conformación Proteica , Sincrotrones
2.
J Synchrotron Radiat ; 29(Pt 5): 1318-1328, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36073892

RESUMEN

The second phase of the ESRF upgrade program did not only provide a new storage ring (Extremely Brilliant Source, EBS) but also allowed several beamlines to be refurbished. The BioSAXS beamline (located on port BM29) was upgraded with a new wiggler source and a larger detector. All analysis software has been rewritten to cope with the increased data flux and continues to provide beamline users with reduced and pre-processed data in real time. This article describes FreeSAS, an open-source collection of various small-angle scattering analysis algorithms needed to reduce and analyze BioSAXS data, and Dahu, the tool used to interface data analysis with beamline control. It further presents the data-processing pipelines for the different data acquisitions modes of the beamline, using either a sample changer for individual homogeneous samples or an inline size-exclusion chromatography setup.


Asunto(s)
Análisis de Datos , Sincrotrones , Cromatografía en Gel , Dispersión del Ángulo Pequeño , Programas Informáticos
4.
J Synchrotron Radiat ; 29(Pt 2): 581-590, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35254323

RESUMEN

ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s-1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.


Asunto(s)
Lentes , Sincrotrones , Cristalografía por Rayos X , Recolección de Datos , Sustancias Macromoleculares/química
5.
J Synchrotron Radiat ; 28(Pt 6): 1996-2002, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738955

RESUMEN

Daiquiri is a web-based user interface (UI) framework for control system monitoring and data acquisition designed for synchrotron beamlines. It provides simple, intuitive and responsive interfaces to control and monitor hardware, launch acquisition sequences and manage associated metadata. Daiquiri concerns itself only with the UI layer; it does not provide a scan engine or controls system but can be easily integrated with existing systems.


Asunto(s)
Programas Informáticos , Sincrotrones , Internet
6.
J Synchrotron Radiat ; 26(Pt 2): 393-405, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30855248

RESUMEN

MXCuBE2 is the second-generation evolution of the MXCuBE beamline control software, initially developed and used at ESRF - the European Synchrotron. MXCuBE2 extends, in an intuitive graphical user interface (GUI), the functionalities and data collection methods available to users while keeping all previously available features and allowing for the straightforward incorporation of ongoing and future developments. MXCuBE2 introduces an extended abstraction layer that allows easy interfacing of any kind of macromolecular crystallography (MX) hardware component, whether this is a diffractometer, sample changer, detector or optical element. MXCuBE2 also works in strong synergy with the ISPyB Laboratory Information Management System, accessing the list of samples available for a particular experimental session and associating, either from instructions contained in ISPyB or from user input via the MXCuBE2 GUI, different data collection types to them. The development of MXCuBE2 forms the core of a fruitful collaboration which brings together several European synchrotrons and a software development factory and, as such, defines a new paradigm for the development of beamline control platforms for the European MX user community.

7.
Acta Crystallogr D Struct Biol ; 72(Pt 3): 413-20, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26960128

RESUMEN

The constant evolution of synchrotron structural biology beamlines, the viability of screening protein crystals for a wide range of heavy-atom derivatives, the advent of efficient protein labelling and the availability of automatic data-processing and structure-solution pipelines have combined to make de novo structure solution in macromolecular crystallography a less arduous task. Nevertheless, the collection of diffraction data of sufficient quality for experimental phasing is still a difficult and crucial step. Here, some examples of good data-collection practice for projects requiring experimental phasing are presented and recent developments at the ESRF Structural Biology beamlines that have facilitated these are illustrated.


Asunto(s)
Cristalografía por Rayos X/métodos , Proteínas/química , Cristalografía por Rayos X/instrumentación , Recolección de Datos/instrumentación , Recolección de Datos/métodos , Procesamiento Automatizado de Datos/instrumentación , Procesamiento Automatizado de Datos/métodos , Diseño de Equipo , Programas Informáticos , Sincrotrones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA