Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
2.
Bioengineering (Basel) ; 11(7)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39061790

RESUMEN

Intrinsic cerebrospinal fluid (CSF) dynamics in the brain have been extensively studied, particularly the egress sites of tagged intrinsic CSF in the meninges. Although spinal CSF recirculates within the central nervous system (CNS), we hypothesized that CSF outflows from the lumbar spinal canal. We aimed to visualize and semi-quantify the outflow using non-contrast MRI techniques. We utilized a 3 Tesla clinical MRI with a 16-channel spine coil, employing time-spatial labeling inversion (Time-SLIP) with tag-on and tag-off acquisitions, T2-weighted coronal 2D fluid-attenuated inversion recovery (FLAIR) and T2-weighted coronal 3D centric ky-kz single-shot FSE (cSSFSE). Images were acquired using time-spatial labeling inversion pulse (Time-SLIP) with tag-on and tag-off acquisitions with varying TI periods. Ten healthy volunteers with no known spinal diseases participated. Variations in tagged CSF outflow were observed across different thoracolumbar nerve root segments in all participants. We quantified CSF outflow at all lumbar levels and the psoas region. There was no significant difference among the ROIs for signal intensity. The tagged CSF outflow from the spinal canal is small but demonstrates egress to surrounding tissues. This finding may pave the way for exploring intrathecal drug delivery, understanding of CSF-related pathologies and its potential as a biomarker for peripheral neuropathy and radiculopathy.

3.
Int J Cancer ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023303

RESUMEN

The purpose of this study was to determine if dual-energy CT (DECT) vital iodine tumor burden (ViTB), a direct assessment of tumor vascularity, allows reliable response assessment in patients with GIST compared to established CT criteria such as RECIST1.1 and modified Choi (mChoi). From 03/2014 to 12/2019, 138 patients (64 years [32-94 years]) with biopsy proven GIST were entered in this prospective, multi-center trial. All patients were treated with tyrosine kinase inhibitors (TKI) and underwent pre-treatment and follow-up DECT examinations for a minimum of 24 months. Response assessment was performed according to RECIST1.1, mChoi, vascular tumor burden (VTB) and DECT ViTB. A change in therapy management could be because of imaging (RECIST1.1 or mChoi) and/or clinical progression. The DECT ViTB criteria had the highest discrimination ability for progression-free survival (PFS) of all criteria in both first line and second line and thereafter treatment, and was significantly superior to RECIST1.1 and mChoi (p < .034). Both, the mChoi and DECT ViTB criteria demonstrated a significantly early median time-to-progression (both delta 2.5 months; both p < .036). Multivariable analysis revealed 6 variables associated with shorter overall survival: secondary mutation (HR = 4.62), polymetastatic disease (HR = 3.02), metastatic second line and thereafter treatment (HR = 2.33), shorter PFS determined by the DECT ViTB criteria (HR = 1.72), multiple organ metastases (HR = 1.51) and lower age (HR = 1.04). DECT ViTB is a reliable response criteria and provides additional value for assessing TKI treatment in GIST patients. A significant superior response discrimination ability for median PFS was observed, including non-responders at first follow-up and patients developing resistance while on therapy.

4.
MAGMA ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916681

RESUMEN

PURPOSE: To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky-kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). METHODS: All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky-kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. RESULTS: The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. CONCLUSION: Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.

5.
Radiol Case Rep ; 19(8): 3483-3487, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38872742

RESUMEN

We present a case of prophylactic endovascular embolization in a 51-year-old man with necrotizing pancreatitis (NP) before undergoing endoscopic necrosectomy (EN). Contrast-enhanced CT imaging revealed the presence of a walled-off necrosis (WON) surrounding the pancreas, with the splenic artery coursing through the cavity. The splenic artery was embolized using n-butyl-2-cyanoacrylate (NBCA) and coils to mitigate the risk of massive bleeding in EN. A newly developed polytetrafluoroethylene (PTFE)-coated microcatheter was used to inject NBCA, enabling embolization of a long segment of the splenic artery without adhering to the vessel wall. Coils were placed distal and proximal to the embolized segment to optimize control. Over 5 sessions of EN, no massive bleeding was encountered. This report demonstrates the benefits of utilizing PTFE-coated microcatheters for enhanced safety and maneuverability during embolization with NBCA. Furthermore, it highlights the importance of prophylactic embolization during EN for managing NP.

6.
Radiol Case Rep ; 19(6): 2112-2116, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38645534

RESUMEN

We describe the endovascular embolization of a 65-year-old man with chronic hepatic encephalopathy. A contrast-enhanced computed tomography demonstrated a splenorenal shunt and a recanalized paraumbilical vein as a continuous portal shunt connecting the left branch of the portal vein and the right common femoral vein. A 2-session embolization was performed for the splenorenal shunt. First, the transvenous approach was used for coil embolization of the splenorenal shunt. It was difficult to advance the catheter system to the embolization site, and it was unstable during coil placement. Second, the paraumbilical venous approach was used to place additional coils. The catheter system had good maneuverability and easily reached the embolization site. Additionally, the stable system allowed for densely packed additional coil implantations. This report demonstrated the paraumbilical venous approach's effectiveness in catheter maneuverability and system stability during coil embolization.

8.
Invest Radiol ; 59(5): 413-423, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37812495

RESUMEN

OBJECTIVES: Fractal analysis of dynamic myocardial stress computed tomography perfusion imaging (4D-CTP) has shown potential to noninvasively differentiate obstructive coronary artery disease (CAD) and coronary microvascular disease (CMD). This study validates fractal analysis of 4D-CTP in a multicenter setting and assesses its diagnostic accuracy in subgroups with ischemia and nonobstructed coronary arteries (INOCA) and with mild to moderate stenosis. MATERIALS AND METHODS: From the AMPLIFiED multicenter trial, patients with suspected or known chronic myocardial ischemia and an indication for invasive coronary angiography were included. Patients underwent dual-source CT angiography, 4D-CTP, and CT delayed-enhancement imaging. Coronary artery disease, CMD, and normal perfusion were defined by a combined reference standard comprising invasive coronary angiography with fractional flow reserve, and absolute or relative CT-derived myocardial blood flow. Nonobstructed coronary arteries were defined as ≤25% stenosis and mild to moderate stenosis as 26%-80%. RESULTS: In 127 patients (27% female), fractal analysis accurately differentiated CAD (n = 61, 23% female), CMD (n = 23, 30% female), and normal perfusion (n = 34, 35% female) with a multiclass area under the receiver operating characteristic curve (AUC) of 0.92 and high agreement (multiclass κ = 0.89). In patients with ischemia (n = 84), fractal analysis detected CAD (n = 61) over CMD (n = 23) with sensitivity of 95%, specificity of 74%, accuracy of 89%, and AUC of 0.83. In patients with nonobstructed coronary arteries (n = 33), INOCA (n = 15) was detected with sensitivity of 100%, specificity of 78%, accuracy of 88%, and AUC of 0.94. In patients with mild to moderate stenosis (n = 27), fractal analysis detected CAD (n = 19) over CMD with sensitivity of 84%, specificity of 100%, accuracy of 89%, and AUC of 0.95. CONCLUSIONS: In this multicenter study, fractal analysis of 4D-CTP accurately differentiated CAD and CMD including subgroups with INOCA and with mild to moderate stenosis.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Humanos , Femenino , Masculino , Constricción Patológica , Fractales , Valor Predictivo de las Pruebas , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada/métodos , Imagen de Perfusión Miocárdica/métodos , Isquemia , Estenosis Coronaria/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen
9.
Egypt Heart J ; 75(1): 103, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38123754

RESUMEN

BACKGROUND: Systemic-to-pulmonary artery shunt (SPAS) is a rare condition that can occur as a result of congenital heart disease or chronic pulmonary inflammation, occasionally leading to life-threatening hemoptysis. Computed tomography (CT) imaging is crucial in the diagnosis of SPAS, and the optimal management approach for SPAS remains uncertain. This case report presents a novel approach to the treatment of SPAS, consisting of transcatheter arterial embolization of the systemic artery followed by lung segmentectomy. CASE PRESENTATION: A 42-year-old man with abnormal chest findings was referred to us and a diagnosis of SPAS was established based on the CT findings showing a blood flow regurgitation from the dilated left 4th intercostal artery to the Lt. A6. The patient was asymptomatic but we decided to treat him to prevent a risk of future hemoptysis. Transcatheter arterial embolization (TAE) of systemic arteries followed by S6 segmentectomy was successfully performed with minimal blood loss and complete removal of the dilated intra-pulmonary blood vessels. Histological analysis confirmed the diagnosis of SPAS. CONCLUSION: We reported a case of SPAS, who was successfully treated with the combination of TAE and subsequent segmentectomy. The blood loss during surgery was minimal and this strategy appeared to minimize future recanalization and hemoptysis. Further studies and long-term follow-up of SPAS patients are required to establish standardized management guidelines for this rare condition.

10.
Intern Med ; 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37926544

RESUMEN

We herein report a 37-year-old man who experienced recurrence of metastatic cardiac rhabdomyosarcoma along with intractable ventricular tachycardia (VT) 7 years after resection of rhabdomyosarcoma in his right elbow. At 36 years old, he developed VT unresponsive to radiofrequency catheter ablation (RFCA). Initially, the cardiac tumor was not detected, but it gradually grew in size at the RFCA site. A surgical biopsy confirmed the diagnosis of metastatic cardiac rhabdomyosarcoma. Despite radiation therapy, cardiac tumor progression and VT instability could not be prevented. Ultimately, the patient died 27 months after the initial documentation of VT.

11.
Cardiovasc Intervent Radiol ; 46(12): 1666-1673, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37973663

RESUMEN

PURPOSE: To describe a novel technique of transvenous radiofrequency catheter ablation of an aldosterone-producing adenoma (APA) of the left adrenal gland using the GOS System (Japan Lifeline, Tokyo, Japan). Using the GOS system, a flexible radiofrequency tip catheter can be inserted into the adrenal central and tributary veins, the drainers for functional tumors. MATERIALS AND METHODS: An APA at the left adrenal gland, which was diagnosed by segmental adrenal venous sampling following administration of 0.25 mg cosyntropin, was ablated using the GOS catheter inserted into adrenal tributary veins via a right femoral vein 7-Fr sheath. The effect of radiofrequency ablation on APA was assessed using the international consensus on surgical outcomes for unilateral primary aldosteronism (PA). RESULTS: No device-related complications were observed. The patient was deeply sedated under blood pressure and heart rate control with continuous administration of ß-blockers. Then, the tumor and surrounding adrenal gland were cauterized at 7000 J two times each in sequence. The output time was 7-11 min for each ablation and 80 min in total. For blood pressure and pulse rate control, esmolol hydrochloride and phentolamine mesylate were used. The contrast enhancement of APA disappeared on dynamic CT immediately after the procedure. PA was biochemically cured until 12 months after the procedure. CONCLUSION: Using the radiofrequency device with the GOS catheter and system is a method for cauterizing adrenal tumors from blood vessels. This approach resulted in a marked reduction in aldosterone concentrations and a complete biochemical cure of PA over the observation period.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Ablación por Catéter , Hiperaldosteronismo , Humanos , Aldosterona , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/cirugía , Glándulas Suprarrenales/irrigación sanguínea , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/cirugía , Catéteres/efectos adversos , Ablación por Catéter/métodos , Hiperaldosteronismo/etiología , Hiperaldosteronismo/cirugía , Hiperaldosteronismo/diagnóstico
12.
BJR Case Rep ; 9(6): 20220116, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37928699

RESUMEN

Postoperative portal vein obstruction could occur as a complication of portal vein reconstruction during hepatic lobectomy or pancreaticoduodenectomy. We report a case of patient with postoperative portal vein obstruction treated with percutaneous transhepatic portal vein stenting without using iodinated contrast media owing to a history of severe allergic reactions. Under ultrasound guidance, carbon dioxide angiography, and appropriate device selection, successful stenting was achieved without serious adverse events. After the operation, portal vein blood flow and clinical symptoms improved, enabling adjuvant chemotherapy. To the best of our knowledge, this is the first case report wherein percutaneous transhepatic portal vein stenting was successfully performed in a patient with an iodine allergy.

14.
Neurol Med Chir (Tokyo) ; 63(10): 473-481, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37648539

RESUMEN

Closed spinal dysraphism (CSD) encompasses a heterogeneous group of spinal cord deformities, which can be accompanied by several types of skin stigmata. These skin stigmata may include inconspicuous features, such as sacral dimples and deformed gluteal clefts, but the association between such mild skin stigmata and CSD is uncertain. This study aimed to reevaluate the indication for magnetic resonance imaging (MRI) in patients with skin stigmata while considering the indication for surgery. A retrospective analysis was conducted on magnetic resonance images of 1255 asymptomatic children with skin stigmata between 2003 and 2015. Skin stigmata classification was based on medical chart data. All subtypes of CSDs except for filum terminale lipomas (FTL), FTL thicker than 2 mm or with low conus medullaris, were considered to meet the surgical indication. CSD prevalence was estimated while considering the surgical indications and assessed after excluding all FTL cases. Skin stigmata were classified into seven types, dimple, deformed gluteal cleft, hair, subcutaneous mass, appendage, discoloration, and protruding bone, and included 1056 isolated and 199 complex ones. The prevalence of CSD was 19.5%, 6.8%, and 0.5% among patients with isolated dimples (n = 881) and 13.9%, 5.8%, and 0.7% among those with isolated deformed gluteal clefts (n = 136) for all cases, surgical indications, and patients without FTL, respectively. Dimples and deformed gluteal clefts had a low prevalence of CSD requiring surgical intervention, and cases without FTL were rare. Asymptomatic patients with mild skin stigmata may not require immediate MRI.


Asunto(s)
Lipoma , Defectos del Tubo Neural , Anomalías Cutáneas , Disrafia Espinal , Niño , Humanos , Estudios Retrospectivos , Anomalías Cutáneas/complicaciones , Defectos del Tubo Neural/diagnóstico por imagen , Defectos del Tubo Neural/cirugía , Defectos del Tubo Neural/complicaciones , Lipoma/diagnóstico por imagen , Lipoma/cirugía , Lipoma/complicaciones , Imagen por Resonancia Magnética/métodos , Disrafia Espinal/diagnóstico por imagen , Disrafia Espinal/complicaciones , Disrafia Espinal/patología , Médula Espinal/patología
15.
J Vasc Interv Radiol ; 34(11): 1963-1969, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37532095

RESUMEN

PURPOSE: To assess the diagnostic performance of carbon dioxide (CO2) and intraprocedural unenhanced computed tomography (CT) for adrenal venous sampling (AVS) (CO2-intraprocedural unenhanced CT-AVS) in patients with primary aldosteronism (PA) and a history of iodine contrast medium allergy. MATERIALS AND METHODS: CO2-intraprocedural unenhanced CT-AVS was performed in 18 patients with iodine contrast media allergies at the authors' hospital between December 2015 and January 2021. CT and noncontrast magnetic resonance angiography were used to evaluate the preoperative adrenal vein anatomy. CO2 venography was performed to confirm adrenal vein catheterization. Additionally, intraprocedural unenhanced CT was also performed to confirm catheter position in the right adrenal gland. RESULTS: In all cases in which CO2-intraprocedural unenhanced CT-AVS was performed, the right and left adrenal veins were catheterized appropriately, leading to a localized diagnosis. Catheterization of the left adrenal vein was confirmed using CO2 venography in all cases. In 7 of the 18 cases, CO2 venography demonstrated selection of the right adrenal vein. In 15 of 18 cases, intraprocedural unenhanced CT demonstrated selection of the right adrenal vein. CONCLUSIONS: CO2-intraprocedural unenhanced CT-AVS demonstrated the same diagnostic ability for PA localization as conventional AVS with iodine contrast media. The proposed method is clinically feasible for AVS, in which iodine contrast media use is restricted.


Asunto(s)
Hiperaldosteronismo , Hipersensibilidad , Yodo , Humanos , Flebografía/métodos , Medios de Contraste/efectos adversos , Dióxido de Carbono/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/irrigación sanguínea , Yodo/efectos adversos , Hiperaldosteronismo/diagnóstico por imagen , Estudios Retrospectivos , Aldosterona
16.
J Radiat Res ; 64(4): 702-710, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37308130

RESUMEN

This prospective study aimed to evaluate whether radiation (RT)-induced myocardial damage by cardiac magnetic resonance (CMR) imaging could be a predictor of cardiac events after chemoradiotherapy (CRT) for esophageal cancer and determine the dose-volume histogram (DVH) parameters of the left ventricle (LV) in predicting cardiac events. CMR imaging was performed before and 6 months after CRT in patients receiving definitive CRT. RT-induced myocardial damage was defined as abnormal CMR findings indicating myocardial fibrosis corresponding to an isodose line of ≥30 Gy. The cutoff values of the LV DVH parameters were calculated using the receiver operating characteristic curve based on the presence of RT-induced myocardial damage. The prognostic factors related to cardiac events of Grade 3 or higher were examined. Twenty-three patients were enrolled in the study. RT-induced myocardial damage by late gadolinium enhancement and/or an increase of 100 ms or higher in native T1 post-CRT was detected in 10 of the 23 patients. LV V45 was the best predictive factor for RT-induced myocardial damage with a cutoff value of 2.1% and an area under the curve of 0.75. The median follow-up period was 82.1 months. The 5- and 7-year cumulative incidences of cardiac events of Grade 3 or higher were 14.7 and 22.4%, respectively. RT-induced myocardial damage and LV V45 were significant risk factors (P = 0.015 and P = 0.013, respectively). RT-induced myocardial damage is a significant predictor of cardiac events. LV V45 is associated with RT-induced myocardial damage and subsequent cardiac events.


Asunto(s)
Enfermedades Cardiovasculares , Neoplasias Esofágicas , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Medios de Contraste , Estudios Prospectivos , Pronóstico , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Imagen por Resonancia Magnética , Neoplasias Esofágicas/radioterapia , Quimioradioterapia/efectos adversos , Valor Predictivo de las Pruebas
18.
Pediatr Radiol ; 53(10): 2120-2133, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37202498

RESUMEN

Anomalous pulmonary venous connections represent a heterogeneous group of congenital heart diseases in which a part or all pulmonary venous flow drains directly or indirectly into the right atrium. Clinically, anomalous pulmonary venous connections may be silent or have variable consequences, including neonatal cyanosis, volume overload and pulmonary arterial hypertension due to the left-to-right shunt. Anomalous pulmonary venous connections are frequently associated with other congenital cardiac defects and their accurate diagnosis is crucial for treatment planning. Therefore, multimodality diagnostic imaging, comprising a combination (but not all) of echocardiography, cardiac catheterization, cardiothoracic computed tomography and cardiac magnetic resonance imaging, helps identify potential blind spots relevant to each imaging modality before treatment and achieve optimal management and monitoring. For the same reasons, diagnostic imaging evaluation using a multimodality fashion should be used after treatment. Finally, those interpreting the images should be familiar with the various surgical approaches used to repair anomalous pulmonary venous connections and the common postoperative complications.


Asunto(s)
Cardiopatías Congénitas , Venas Pulmonares , Síndrome de Cimitarra , Recién Nacido , Humanos , Síndrome de Cimitarra/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Corazón , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/anomalías , Tomografía Computarizada por Rayos X
19.
J Orthop Sci ; 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37105788

RESUMEN

BACKGROUND: Several reports exist on syndromic cervical kyphosis in the elderly, including dropped head syndrome, degenerative spondylosis, and neurological diseases; however, it is rarely reported in young patients especially with complications. CASE PRESENTATION: We describe a case of a 25-year-old man who presented severe cervical kyphosis with dropped head syndrome, horizontal-gaze disorder, dysphagia, and myelopathy. The etiology of this cervical kyphosis was suspected to be as a result of a combination of an underlying developmental disorder and habitual, long-term cervical flexion postures while engaging in smartphone games. Combined anterior and posterior surgeries resulted in good outcomes and improved the patient's quality of life remarkably. CONCLUSION: Cervical kyphosis awareness in young patients is crucial. Moreover, combined anterior and posterior approach provides secure, good results, and with less sequelae.

20.
Radiol Case Rep ; 18(5): 1973-1977, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36970241

RESUMEN

Endovascular therapy is an important method of treating high-flow arteriovenous malformations (AVMs). The nidus of AVMs can be treated by transarterial or percutaneous approaches with the use of ethanol as a strong embolic agent; however, treatment outcomes are not always satisfactory and complications including skin necrosis often occur, particularly following the treatment of superficial lesions. Herein, we describe successful transvenous sclerotherapy of high-flow AVMs in the finger of a 47-year-old female patient that were causing erythema and spontaneous pain using ethanolamine oleate (EO) as a safe sclerosant. Dynamic contrast-enhanced computed tomography and angiography revealed a high-flow type Ⅲb AVM according to Yakes classification. Using the transvenous approach, 5% EO with idoxanol was injected into the nidus of the AVM 3 times over 2 sessions. An arterial tourniquet was used to achieve stasis of blood flow at the nidus and microballoon occlusion of the outflow vein was used to ensure the sclerosant effectively reached the nidus. Near-total occlusion of the nidus was achieved leading to improved symptoms. Mild edema lasting 2 weeks occurred as a minor reaction after each session. Finger amputation may have been avoided by using this treatment. Transvenous EO sclerotherapy using an arterial tourniquet and balloon occlusion may have utility in treating AVMs in the extremities.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA