Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Nucleic Acids Res ; 52(D1): D1694-D1698, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-37953359

RESUMEN

Vesiclepedia (http://www.microvesicles.org) is a free web-based compendium of DNA, RNA, proteins, lipids and metabolites that are detected or associated with extracellular vesicles (EVs) and extracellular particles (EPs). EVs are membranous vesicles that are secreted ubiquitously by cells from all domains of life from archaea to eukaryotes. In addition to EVs, it was reported recently that EPs like exomeres and supermeres are secreted by some mammalian cells. Both EVs and EPs contain proteins, nucleic acids, lipids and metabolites and has been proposed to be implicated in several key biological functions. Vesiclepedia catalogues proteins, DNA, RNA, lipids and metabolites from both published and unpublished studies. Currently, Vesiclepedia contains data obtained from 3533 EV studies, 50 550 RNA entries, 566 911 protein entries, 3839 lipid entries, 192 metabolite and 167 DNA entries. Quantitative data for 62 822 entries from 47 EV studies is available in Vesiclepedia. The datasets available in Vesiclepedia can be downloaded as tab-delimited files or accessible through the FunRich-based Vesiclepedia plugin.


Asunto(s)
Vesículas Extracelulares , Animales , Vesículas Extracelulares/metabolismo , Proteínas/metabolismo , ARN/metabolismo , ADN/metabolismo , Lípidos , Mamíferos
2.
Cell Rep ; 42(8): 112837, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37471225

RESUMEN

Mechanical forces are thought to activate mechanosensitive PIEZO channels by changing the conformation of a large transmembrane blade domain. Yet, whether different stimuli induce identical conformational changes in this domain remains unclear. Here, we repurpose a cyclic permuted green fluorescent protein as a conformation-sensitive probe to track local rearrangements along the PIEZO1 blade. Two independent probes, one inserted in an extracellular site distal to the pore and the other in a distant intracellular proximal position, elicit sizable fluorescence signals when the tagged channels activate in response to fluid shear stress of low intensity. Neither cellular indentations nor osmotic swelling of the cell elicit detectable fluorescence signals from either probe, despite the ability of these stimuli to activate the tagged channels. High-intensity flow stimuli are ineffective at eliciting fluorescence signals from either probe. Together, these findings suggest that low-intensity fluid shear stress causes a distinct form of mechanical stress to the cell.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Canales Iónicos/metabolismo , Dominios Proteicos , Movimiento (Física) , Estrés Mecánico , Fluorometría , Mecanotransducción Celular/fisiología
3.
Ultrasonics ; 134: 107052, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37295220

RESUMEN

The use of ultrasonic energy has mostly been investigated for the flotation process in mineral processing, but its application to flocculation with collectors is extremely limited. Therefore, in this study, the effect of ultrasound in the shear flocculation technique, was intended to be revealed by using a celestite sample. The initial studies carried out for this purpose showed that in the absence of any reagent, the ultrasonication decreased the surface charge of the mineral, which caused the coagulation of the celestite suspension. In this scope, the short application of ultrasound at high power (i.e., 2 min batch regime and 150 W) provided a more positive effect. In the flocculation process carried out with collectors, the use of ultrasonic energy as a pre-phase for the suspension enhanced the aggregation of celestite particles. This result also fits well with the rise in the contact angle and the decrease in the zeta potential of the mineral due to the ultrasound. However, when the ultrasound was applied directly to the flocculation phase (ultrasound-induced flocculation only), the aggregation of celestite particles was affected adversely. Consequently, it can be said that in the shear flocculation process, the ultrasonic treatment should be used as a pre-phase for mineral suspensions. In this case, the flocculation of fine mineral particles in suspensions with surfactants can be improved by ultrasonic processing.

4.
J Gen Physiol ; 155(5)2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36715688

RESUMEN

Mechanosensitive PIEZO1 ion channels open in response to membrane stretch. Yet, the underlying microscopic mechanism of this activation remains unknown. To probe this mechanism, we used cell-attached pressure-clamp recordings to measure single channel currents at different steady-state negative pipette pressures, spanning the full range of the channel's pressure sensitivity. Pressure-dependent activation occurs through a sharp reduction of the mean shut duration and through a moderate increase of the mean open duration. Across all tested pressures, the distribution of open and shut dwell times best follows sums of two and three exponential components, respectively. As the magnitude of the pressure stimulus increases, the time constants of most of these exponential components gradually change, in opposite directions for open and shut dwell times, and to a similar extent. In addition, while the relative amplitudes of fast and slow components remain unchanged for open intervals, they fully reverse for shut intervals, further reducing the mean shut duration. Using two-dimensional dwell time analysis, Markov-chain modeling, and simulations, we identified a minimal five-states model which recapitulates essential characteristics of single channel data, including microscopic reversibility, correlations between adjacent open and shut intervals, and asymmetric modulation of dwell times by pressure. This study identifies a microscopic mechanism for the activation of PIEZO1 channels by pressure-induced membrane stretch and deepens our fundamental understanding of mechanotransduction by a vertebrate member of the PIEZO channel family.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Cinética , Canales Iónicos/metabolismo
5.
Proc Natl Acad Sci U S A ; 119(29): e2202269119, 2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35858335

RESUMEN

Piezo1 channels are essential mechanically activated ion channels in vertebrates. Their selective activation by the synthetic chemical activator Yoda1 opened new avenues to probe their gating mechanisms and develop novel pharmaceuticals. Yet, the nature and extent of Piezo1 functions modulated by this small molecule remain unclear. Here we close this gap by conducting a comprehensive biophysical investigation of the effects of Yoda1 on mouse Piezo1 in mammalian cells. Using calcium imaging, we first show that cysteine bridges known to inhibit mechanically evoked Piezo1 currents also inhibit activation by Yoda1, suggesting Yoda1 acts by energetically modulating mechanosensory domains. The presence of Yoda1 alters single-channel dwell times and macroscopic kinetics consistent with a dual and reciprocal energetic modulation of open and shut states. Critically, we further discovered that the electrophysiological effects of Yoda1 depend on membrane potential and temperature, two other Piezo1 modulators. This work illuminates a complex interplay between physical and chemical modulators of Piezo1 channels.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Pirazinas , Tiadiazoles , Animales , Canales Iónicos/agonistas , Canales Iónicos/metabolismo , Mecanotransducción Celular/fisiología , Potenciales de la Membrana , Ratones , Pirazinas/farmacología , Temperatura , Tiadiazoles/farmacología
6.
J Cell Sci ; 134(16)2021 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-34322699

RESUMEN

G-protein-coupled receptor (GPCR) 68 (GPR68, or OGR1) couples extracellular acidifications and mechanical stimuli to G-protein signaling and plays important roles in vascular physiology, neuroplasticity and cancer progression. Inspired by previous GPCR-based reporters, here, we inserted a cyclic permuted fluorescent protein into the third intracellular loop of GPR68 to create a genetically encoded fluorescent reporter of GPR68 activation we call 'iGlow'. iGlow responds to known physiological GPR68 activators such as fluid shear stress and extracellular acidifications. In addition, iGlow responds to Ogerin, a synthetic GPR68-selective agonist, but not to a non-active Ogerin analog, showing the specificity of iGlow-mediated fluorescence signals. Flow-induced iGlow activation is not eliminated by pharmacological modulation of downstream G-protein signaling, disruption of actin filaments or application of GsMTx4, an inhibitor of certain mechanosensitive ion channels activated by membrane stretch. Deletion of the conserved helix 8, proposed to mediate mechanosensitivity in certain GPCRs, does not eliminate flow-induced iGlow activation. iGlow could be useful to investigate the contribution of GPR68-dependent signaling in health and disease.


Asunto(s)
Receptores Acoplados a Proteínas G , Transducción de Señal , Receptores Acoplados a Proteínas G/genética , Estrés Mecánico
7.
RSC Adv ; 11(26): 15519-15527, 2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35481205

RESUMEN

Radiation therapy is widely used as a treatment tool for malignancies. However, radiation-related complications are still unavoidable risks for off-target cells. Little is known about radiation therapy's possible effects on mechanical features of the off-target cells such as human red blood cells (RBCs). RBCs are nucleus-free circulating cells that can deform without losing functionality in healthy conditions. Thus, to evaluate in vitro effects of radiation therapy on the healthy plasma membrane of cells, RBCs were selected as a primary test model. RBCs were exposed to clinically prescribed radiotherapy doses of 2 Gy, 12 Gy and, 25 Gy, and each radiotherapy dose group was compared to a non-irradiated group. Cells were characterized by stretching using dual-beam optical tweezers and compared using the resulting deformability index. The group receiving the highest radiation dose was found statistically distinguishable from the control group (DI0Gy = 0.33 ± 0.08), and revealed the highest deformability index (DI25Gy = 0.38 ± 0.11, p = 0.0068), while no significant differences were found for 2 Gy (DI2Gy = 0.33 ± 0.08, p = 0.9) and 12 Gy (DI12Gy = 0.31 ± 0.09, p = 0.2) dose groups. Based on these findings, we conclude that radiotherapy exposure may alter the deformability of red blood cells depending on the dose amount, and measurement of deformability index by dual-beam optical tweezers can serve as a sensitive biomarker to probe responses of cells to the radiotherapy.

8.
J Nutr Educ Behav ; 52(11): 1058-1065, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33168205

RESUMEN

OBJECTIVE: This study aimed to evaluate the usability of the virtual cafeteria (VC) and determine its suitability for further studies in portion size education and rehabilitation of nutrition. METHODS: The study was conducted with 73 participants (aged 18-40 years). The VC, where the participants performed the task of assembling a meal, was created as a virtual reality simulation of a buffet-style cafeteria (94 food and 10 beverage items). The participants were asked to complete the System Usability Scale, which regards ≥70 points as acceptable, and to give comments about the VC. RESULTS: The mean System Usability Scale score was 79.4 ± 12.71 (range, 22.2-97.2). Approximately 68% of the participants described positive qualities for the VC. The participants with technical background reported the VC as more usable (96%) than the others (74%) (χ2 = 5,378; df = 1, P = 0.025). CONCLUSIONS AND IMPLICATIONS: Offered as a novel tool for education and rehabilitation of nutrition, the VC was confirmed to feature good usability.


Asunto(s)
Promoción de la Salud/métodos , Tamaño de la Porción , Realidad Virtual , Adolescente , Adulto , Dieta Saludable , Conducta Alimentaria , Femenino , Humanos , Masculino , Adulto Joven
9.
Radiol Med ; 125(10): 981-989, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32277333

RESUMEN

OBJECTIVE: The prognostic effect of human papilloma virus (HPV) on early radioresponse before brachytherapy was evaluated in locally advanced cervix uteri carcinoma patients. METHODS: Between 2015 and 2018, 150 patients with locally advanced carcinoma of the cervix uteri from University of Health Sciences Okmeydani Training and Research Hospital and Istanbul Oncology Hospital underwent chemotherapy concomitant with external radiotherapy and brachytherapy after performing fluorodeoxyglucose positron emission tomography (FDG PET) and magnetic resonance imaging (MRI) for purposes of staging and treatment planning. The treatment results of patients analyzed retrospectively. RESULTS: The median age of 57 patients was 53 years, and the initial tumor volume was 27 cm3. The median follow-up period was 22 months. The median tumor volume after external radiotherapy was significantly higher in patients without local control than those who responded to external radiotherapy (p = 0.031). The mean tumor diameter and volume in all HPV-negative patients after external radiotherapy were significantly higher than those of HPV-positive patients (p = 0.011 and p = 0.046, respectively). In a group of patients with poor early responses, local disease control could not be achieved despite the use of recommended higher doses of brachytherapy. CONCLUSION: We could not determine the correlation between HPV contamination and patients who had early response intervention. But residual tumor of more than 2 cm in diameter after external radiotherapy may be a predictor of failed local control and development of metastasis within a short time.


Asunto(s)
Braquiterapia , Quimioradioterapia/métodos , Papillomaviridae , Neoplasias del Cuello Uterino/terapia , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Pronóstico , Radiofármacos , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Carga Tumoral , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/virología
10.
Nat Commun ; 10(1): 4503, 2019 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-31582801

RESUMEN

Mechanosensitive Piezo1 and Piezo2 channels transduce various forms of mechanical forces into cellular signals that play vital roles in many important biological processes in vertebrate organisms. Besides mechanical forces, Piezo1 is selectively activated by micromolar concentrations of the small molecule Yoda1 through an unknown mechanism. Here, using a combination of all-atom molecular dynamics simulations, calcium imaging and electrophysiology, we identify an allosteric Yoda1 binding pocket located in the putative mechanosensory domain, approximately 40 Å away from the central pore. Our simulations further indicate that the presence of the agonist correlates with increased tension-induced motions of the Yoda1-bound subunit. Our results suggest a model wherein Yoda1 acts as a molecular wedge, facilitating force-induced conformational changes, effectively lowering the channel's mechanical threshold for activation. The identification of an allosteric agonist binding site in Piezo1 channels will pave the way for the rational design of future Piezo modulators with clinical value.


Asunto(s)
Activación del Canal Iónico/efectos de los fármacos , Canales Iónicos/metabolismo , Pirazinas/farmacología , Tiadiazoles/farmacología , Sitios de Unión , Células HEK293 , Humanos , Microscopía Intravital/métodos , Canales Iónicos/agonistas , Canales Iónicos/genética , Ligandos , Simulación de Dinámica Molecular , Mutación , Imagen Óptica/métodos , Técnicas de Placa-Clamp , Unión Proteica , Dominios Proteicos
11.
J Vis Exp ; (143)2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30663695

RESUMEN

By focusing low-intensity ultrasound pulses that penetrate soft tissues, LIPUS represents a promising biomedical technology to remotely and safely manipulate neural firing, hormonal secretion and genetically-reprogrammed cells. However, the translation of this technology for medical applications is currently hampered by a lack of biophysical mechanisms by which targeted tissues sense and respond to LIPUS. A suitable approach to identify these mechanisms would be to use optical biosensors in combination with LIPUS to determine underlying signaling pathways. However, implementing LIPUS to a fluorescence microscope may introduce undesired mechanical artefacts due to the presence of physical interfaces that reflect, absorb and refract acoustic waves. This article presents a step-by-step procedure to incorporate LIPUS to commercially-available upright epi-fluorescence microscopes while minimizing the influence of physical interfaces along the acoustic path. A simple procedure is described to operate a single-element ultrasound transducer and to bring the focal zone of the transducer into the objective focal point. The use of LIPUS is illustrated with an example of LIPUS-induced calcium transients in cultured human glioblastoma cells measured using calcium imaging.


Asunto(s)
Microscopía Fluorescente/métodos , Ondas Ultrasónicas , Acústica , Animales , Señalización del Calcio , Línea Celular Tumoral , Humanos , Poliésteres/química , Transducción de Señal/fisiología
12.
Nanotechnology ; 29(28): 285701, 2018 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-29664418

RESUMEN

Biological feedback mechanisms exert precise control over the initiation and termination of molecular self-assembly in response to environmental stimuli, while minimizing the formation and propagation of defects through self-repair processes. Peptide amphiphile (PA) molecules can self-assemble at physiological conditions to form supramolecular nanostructures that structurally and functionally resemble the nanofibrous proteins of the extracellular matrix, and their ability to reconfigure themselves in response to external stimuli is crucial for the design of intelligent biomaterials systems. Here, we investigated real-time self-assembly, deformation, and recovery of PA nanofibers in aqueous solution by using a force-stabilizing double-pass scanning atomic force microscopy imaging method to disrupt the self-assembled peptide nanofibers in a force-dependent manner. We demonstrate that nanofiber damage occurs at tip-sample interaction forces exceeding 1 nN, and the damaged fibers subsequently recover when the tip pressure is reduced. Nanofiber ends occasionally fail to reconnect following breakage and continue to grow as two individual nanofibers. Energy minimization calculations of nanofibers with increasing cross-sectional ellipticity (corresponding to varying levels of tip-induced fiber deformation) support our observations, with high-ellipticity nanofibers exhibiting lower stability compared to their non-deformed counterparts. Consequently, tip-mediated mechanical forces can provide an effective means of altering nanofiber integrity and visualizing the self-recovery of PA assemblies.

13.
Semin Cell Dev Biol ; 73: 153-164, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28811262

RESUMEN

Atomic force microscopy is an emerging tool for investigating the biomolecular aspects of cellular interactions; however, cell and tissue analyses must frequently be performed in aqueous environment, over rough surfaces, and on complex adhesive samples that complicate the imaging process and readily facilitate the blunting or fouling of the AFM probe. In addition, the shape and surface chemistry of the probe determine the quality and types of data that can be acquired from biological materials, with certain information becoming available only within a specific range of tip lengths or diameters, or through the assistance of specific chemical or biological functionalization procedures. Consequently, a broad range of probe modification techniques has been developed to extend the capabilities and overcome the limitations of biological AFM measurements, including the fabrication of AFM tips with specialized morphologies, surface coating with biologically affine molecules, and the attachment of proteins, nucleic acids and cells to AFM probes. In this review, we underline the importance of probe choice and modification for the AFM analysis of biomaterials, discuss the recent literature on the use of non-standard AFM tips in life sciences research, and consider the future utility of tip functionalization methods for the investigation of fundamental cell and tissue interactions.


Asunto(s)
Materiales Biocompatibles/análisis , Materiales Biocompatibles/química , Microscopía de Fuerza Atómica , Animales , Humanos
14.
Biomacromolecules ; 18(10): 3114-3130, 2017 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-28840715

RESUMEN

Chirality and morphology are essential factors for protein function and interactions with other biomacromolecules. Extracellular matrix (ECM) proteins are also similar to other proteins in this sense; however, the complexity of the natural ECM makes it difficult to study these factors at the cellular level. The synthetic peptide nanomaterials harbor great promise in mimicking specific ECM molecules as model systems. In this work, we demonstrate that mechanosensory responses of stem cells are directly regulated by the chirality and morphology of ECM-mimetic peptide nanofibers with strictly controlled characteristics. Structural signals presented on l-amino acid containing cylindrical nanofibers (l-VV) favored the formation of integrin ß1-based focal adhesion complexes, which increased the osteogenic potential of stem cells through the activation of nuclear YAP. On the other hand, twisted ribbon-like nanofibers (l-FF and d-FF) guided the cells into round shapes and decreased the formation of focal adhesion complexes, which resulted in the confinement of YAP proteins in the cytosol and a corresponding decrease in osteogenic potential. Interestingly, the d-form of twisted-ribbon like nanofibers (d-FF) increased the chondrogenic potential of stem cells more than their l-form (l-FF). Our results provide new insights into the importance and relevance of morphology and chirality of nanomaterials in their interactions with cells and reveal that precise control over the chemical and physical properties of nanostructures can affect stem cell fate even without the incorporation of specific epitopes.


Asunto(s)
Mecanotransducción Celular , Células Madre Mesenquimatosas/efectos de los fármacos , Nanofibras/química , Fragmentos de Péptidos/química , Animales , Línea Celular , Células Cultivadas , Proteínas de la Matriz Extracelular/química , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Humanos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/metabolismo , Nanofibras/efectos adversos , Osteogénesis , Ratas
15.
Biomater Sci ; 5(7): 1293-1303, 2017 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-28561086

RESUMEN

There is an urgent need for more efficient treatment of chronic wounds in diabetic patients especially with a high risk of leg amputation. Biomaterials capable of presenting extracellular matrix-mimetic signals may assist in the recovery of diabetic wounds by creating a more conducive environment for blood vessel formation and modulating the immune system. In a previous study, we showed that glycosaminoglycan-mimetic peptide nanofibers are able to increase the rate of closure in STZ-induced diabetic rats by induction of angiogenesis. The present study investigates the effect of a heparin-mimetic peptide amphiphile (PA) nanofiber gel on full-thickness excisional wounds in a db/db diabetic mouse model, with emphasis on the ability of the PA nanofiber network to regulate angiogenesis and the expression of pro-inflammatory cytokines. Here, we showed that the heparin-mimetic PA gel can support tissue neovascularization, enhance the deposition of collagen and expression of alpha-smooth muscle actin (α-SMA), and eliminate the sustained presence of interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α) in the diabetic wound site. As the absence of neovascularization and overexpression of pro-inflammatory markers are a hallmark of diabetes and interfere with wound recovery by preventing the healing process, the heparin-mimetic PA treatment is a promising candidate for acceleration of diabetic wound healing by modulating angiogenesis and local immune response.


Asunto(s)
Diabetes Mellitus Experimental/fisiopatología , Heparina/química , Interacciones Hidrofóbicas e Hidrofílicas , Oligopéptidos/química , Oligopéptidos/farmacología , Cicatrización de Heridas/efectos de los fármacos , Actinas/metabolismo , Animales , Materiales Biomiméticos/química , Materiales Biomiméticos/farmacología , Colágeno/metabolismo , Geles , Regulación de la Expresión Génica/efectos de los fármacos , Ratones , Nanofibras , Factor A de Crecimiento Endotelial Vascular/metabolismo
16.
Biomaterials ; 134: 117-127, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28458029

RESUMEN

Burn injuries are one of the most common types of trauma worldwide, and their unique physiology requires the development of specialized therapeutic materials for their treatment. Here, we report the use of synthetic, functional and biodegradable peptide nanofiber gels for the improved healing of burn wounds to alleviate the progressive loss of tissue function at the post-burn wound site. These bioactive nanofiber gels form scaffolds that recapitulate the structure and function of the native extracellular matrix through signaling peptide epitopes, which can trigger angiogenesis through their affinity to basic growth factors. In this study, the angiogenesis-promoting properties of the bioactive scaffolds were utilized for the treatment of a thermal burn model. Following the excision of necrotic tissue, bioactive gels and control solutions were applied topically onto the wound area. The wound healing process was evaluated at 7, 14 and 21 days following injury through histological observations, immunostaining and marker RNA/protein analysis. Bioactive peptide nanofiber-treated burn wounds formed well-organized and collagen-rich granulation tissue layers, produced a greater density of newly formed blood vessels, and exhibited increased re-epithelialization and skin appendage development with minimal crust formation, while non-bioactive peptide nanofibers and the commercial wound dressing 3M™ Tegaderm™ did not exhibit significant efficiency over sucrose controls. Overall, the heparin-mimetic peptide nanofiber gels increased the rate of repair of burn injuries and can be used as an effective means of facilitating wound healing.


Asunto(s)
Quemaduras/terapia , Geles/química , Heparina/química , Nanofibras/química , Péptidos/química , Andamios del Tejido/química , Animales , Dicroismo Circular , Inmunohistoquímica , Masculino , Ratones , Ratones Endogámicos BALB C , Microscopía Electrónica de Rastreo , Cicatrización de Heridas/fisiología
17.
Micron ; 89: 60-76, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27507194

RESUMEN

The present review details the methods used for the measurement of cells and their exudates using atomic force microscopy (AFM) and outlines the general conclusions drawn by the mechanical characterization of biological materials through this method. AFM is a material characterization technique that can be operated in liquid conditions, allowing its use for the investigation of the mechanical properties of biological materials in their native environments. AFM has been used for the mechanical investigation of proteins, nucleic acids, biofilms, secretions, membrane bilayers, tissues and bacterial or eukaryotic cells; however, comparison between studies is difficult due to variances between tip sizes and morphologies, sample fixation and immobilization strategies, conditions of measurement and the mechanical parameters used for the quantification of biomaterial response. Although standard protocols for the AFM investigation of biological materials are limited and minor differences in measurement conditions may create large discrepancies, the method is nonetheless highly effective for comparatively evaluating the mechanical integrity of biomaterials and can be used for the real-time acquisition of elasticity data following the introduction of a chemical or mechanical stimulus. While it is currently of limited diagnostic value, the technique is also useful for basic research in cancer biology and the characterization of disease progression and wound healing processes.


Asunto(s)
Bacterias/ultraestructura , Fenómenos Fisiológicos Celulares , Microscopía de Fuerza Atómica/métodos , Fenómenos Fisiológicos Bacterianos , Materiales Biocompatibles , Biopelículas , Elasticidad , Humanos , Proteínas/ultraestructura
18.
Curr Pharm Des ; 22(11): 1521-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26654438

RESUMEN

Certain bacteria selectively attack tumor tissues and trigger tumor shrinkage by producing toxins and modulating the local immune system, but their clinical utility is limited because of the dangers posed by systemic infection. Genetic engineering can be used to minimize the risks associated with tumor-targeting pathogens, as well as to increase their efficiency in killing tumor cells. Advances in genetic circuit design have led to the development of bacterial strains with enhanced tumor-targeting capacities and the ability to secrete therapeutics, cytotoxic proteins and prodrug-cleaving enzymes, which allows their safe and effective use for cancer treatment. The present review details the recent advances in the design and application of these modified bacterial strains.


Asunto(s)
Bacterias/metabolismo , Terapia Biológica , Neoplasias/terapia , Células Procariotas/citología , Animales , Bacterias/genética , Humanos , Neoplasias/microbiología , Neoplasias/fisiopatología
19.
Int J Phytoremediation ; 18(8): 785-93, 2016 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-26709546

RESUMEN

Following the rapid uptake of contaminants in the first few hours of exposure, plants typically attempt to cope with the toxic burden by releasing part of the sorbed material back into the environment. The present study investigates the general trends in the release profiles of different metal(loid)s in the aquatic macrophyte Lemna minor and details the correlations that exist between the release of metal(loid) species. Water samples with distinct contamination profiles were taken from Nilüfer River (Bursa, Turkey), Yeniçaga Lake (Bolu, Turkey), and Beysehir Lake (Konya, Turkey) and used for release studies; 36 samples were tested in total. Accumulation and release profiles were monitored over five days for 11 metals and a metalloid ((208)Pb, (111)Cd, (52)Cr,(53)Cr,(60)Ni,(63)Cu,(65)Cu,(75)As,(55)Mn, (137)Ba, (27)Al, (57)Fe, (66)Zn,(68)Zn) and correlation, cluster and principal component analyses were employed to determine the factors that affect the release of these elements. Release profiles of the tested metal(loid)s were largely observed to be distinct; however, strong correlations have been observed between certain metal pairs (Cr/Ni, Cr/Cu, Zn/Ni) and principal component analysis was able to separate the metal(loid)s into three well-resolved groups based on their release.


Asunto(s)
Araceae/metabolismo , Metales/metabolismo , Contaminantes del Agua/metabolismo , Biodegradación Ambiental , Agua Dulce , Turquía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA