Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.018
Filtrar
1.
Rev Clin Esp (Barc) ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032915

RESUMEN

BACKGROUND AND OBJECTIVES: Cardiac amyloidosis (CA) is a common pathology in elderly patients that usually presents as heart failure (HF). However, it is not clear whether CA associated with HF has a worse prognosis compared with HF due to other etiologies. MATERIAL AND METHODS: Prospective, observational cohort study that recruited patients ≥65 years of age with HF in 30 Spanish centers. The cohort was divided according to whether the patients had AC or not. Patients were followed for 1 year. RESULTS: A total of 484 patients were included in the analysis. The population was elderly (median 86 years) and 49% were women CA was present in 23.8 % of the included patients. In the CA group, there was a lower prevalence of diabetes mellitus and valvular disease. At one year of follow-up, mortality was significantly more frequent in patients with CA compared to those without (33.0 vs.14.9%, p < 0.001). However, there were no differences between both groups in visits to the emergency room or readmissions. In the multivariate analysis, the variables that were shown to predict all-cause mortality at one year of follow-up were chronic kidney disease (HR 1.75 (1.01-3.05) p 0.045), NT-proBNP levels (HR 2.51 (1.46-4.30) p < 0.001), confusion (HR 2.05 (1.01-4.17), p 0.048), and the presence of CA (HR 1.77 (1.11-2.84), p 0.017). CONCLUSION: The presence of CA in elderly patients with HF is related to a worse prognosis at one year of follow-up. Early diagnosis of the pathology and multidisciplinary management can help improve patient outcomes.

2.
Sci Rep ; 14(1): 12857, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834720

RESUMEN

Magneto-optical measurements are fundamental research tools that allow for studying the hitherto unexplored optical transitions and the related applications of topological two-dimensional (2D) transition metal dichalcogenides (TMDs). A theoretical model is developed for the first-order magneto-resonant Raman scattering in a monolayer of TMD. A significant number of avoided crossing points involving optical phonons in the magneto-polaron (MP) spectrum, a superposition of the electron and hole states in the excitation branches, and their manifestations in optical transitions at various light scattering configurations are unique features for these 2D structures. The Raman intensity reveals three resonant splittings of double avoided-crossing levels. The three excitation branches are present in the MP spectrum provoked by the coupling of the Landau levels in the conduction and valence bands via an out-of-plane A 1 -optical phonon mode. The energy gaps at the anticrossing points in the MP scattering spectrum are revealed as a function of the electron and hole optical deformation potential constants. The resonant MP Raman scattering efficiency profile allows for quantifying the relative contribution of the conduction and valence bands in the formation of MPs. The results obtained are a guideline for controlling MP effects on the magneto-optical properties of TMD semiconductors, which open pathways to novel optoelectronic devices based on 2D TMDs.

3.
Pediatr Allergy Immunol ; 35(6): e14179, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38923448

RESUMEN

LRBA is a cytoplasmic protein that is ubiquitously distributed. Almost all LRBA domains have a scaffolding function. In 2012, it was reported that homozygous variants in LRBA are associated with early-onset hypogammaglobulinemia. Since its discovery, more than 100 pathogenic variants have been reported. This review focuses on the variants reported in LRBA and their possible associations with clinical phenotypes. In this work LRBA deficiency cases reported more than 11 years ago have been revised. A database was constructed to analyze the type of variants, age at onset, clinical diagnosis, infections, autoimmune diseases, and cellular and immunoglobulin levels. The review of cases from 2012 to 2023 showed that LRBA deficiency was commonly diagnosed in patients with a clinical diagnosis of Common Variable Immunodeficiency, followed by enteropathy, neonatal diabetes mellitus, ALPS, and X-linked-like syndrome. Most cases show early onset of presentation at <6 years of age. Most cases lack protein expression, whereas hypogammaglobulinemia is observed in half of the cases, and IgG and IgA levels are isotypes reported at low levels. Patients with elevated IgG levels exhibited more than one autoimmune manifestation. Patients carrying pathogenic variants leading to a premature stop codon show a severe phenotype as they have an earlier onset of disease presentation, severe autoimmune manifestations, premature death, and low B cells and regulatory T cell levels. Missense variants were more common in patients with low IgG levels and cytopenia. This work lead to the conclusion that the type of variant in LRBA has association with disease severity, which leads to a premature stop codon being the ones that correlates with severe disease.


Asunto(s)
Dominios Proteicos , Humanos , Dominios Proteicos/genética , Fenotipo , Agammaglobulinemia/genética , Agammaglobulinemia/inmunología , Agammaglobulinemia/diagnóstico , Niño , Edad de Inicio , Mutación , Inmunodeficiencia Variable Común/genética , Inmunodeficiencia Variable Común/diagnóstico , Inmunodeficiencia Variable Común/inmunología , Proteínas Adaptadoras Transductoras de Señales
5.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38851565

RESUMEN

INTRODUCTION: The incidence of hip fracture in the elderly is on the rise, occasionally accompanied by concurrent upper limb fractures. Our investigation aims to determine whether these patients experience poorer functional outcomes, prolonged hospitalization, or higher mortality rates when compared to those with isolated hip fracture. MATERIAL AND METHODS: We retrospectively reviewed 1,088 elderly patients admitted to our centre with hip fracture between January 2017 and March 2020. We recorded the presence of concomitant fractures and their treatment. We analyzed the duration of hospital stay, in-hospital mortality and function. RESULTS: We identified 63 patients with concomitant upper limb fracture (5.6%). Among them, 93.7% were women, and the average age was 86.4 years. 80.9% of the upper limb fractures were distal radius or proximal humerus. Patients with concomitant fracture had increased length of stay (mean, 19.6 vs, 12.8, p=0.002), decreased proportion of patients returning to their own home at discharge (23.6% vs, 26.3%, p=0.042) and increased in-hospital mortality rate (9.5% vs, 5.9%, p=0.003). CONCLUSIONS: Patients with concomitant upper limb fracture require a longer length of stay and exhibit an elevated in-hospital mortality rate. Furthermore, this condition is associated with a reduced short-term functional recovery, thereby decreasing the chances of the patient returning home upon hospital discharge.

6.
Acta Ortop Mex ; 38(2): 113-118, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38782478

RESUMEN

INTRODUCTION: conventional parosteal osteosarcoma is an uncommon malignant bone tumor, comprising 4% of all osteosarcomas. Although rare, parosteal osteosarcoma is the most common type of osteosarcoma of the bone surface. We present the clinical, histological and imaging characteristics of a rare histologic variant of a parosteal osteosarcoma, review the literature and emphasize the importance of radio-pathological correlation as well as the interpretation of a representative biopsy in order to obtain the correct diagnosis. CASE REPORT: a 36-year old woman began her condition one year prior to admission to the hospital with increased volume in the left knee and pain. Image studies showed a juxtacortical heterogeneous tumor localized on the posterior surface of the distal femoral metaphysis. An incisional biopsy was performed, with the diagnosis of a Parosteal Osteosarcoma and a wide surgical resection was undertaken. According to the findings of the surgical specimen, the diagnosis of a Parosteal Osteosarcoma with low grade chondrosarcoma and liposarcoma components was made. The knowledge of this rare parosteal osteosarcoma variant can lead the orthopedic oncologists to avoid overlooking the adipose component and provide adequate surgical margins. CONCLUSION: we present the clinical, histological and imaging characteristics of a Parosteal Osteosarcoma with low grade liposarcoma and chondrosarcoma components.


INTRODUCCIÓN: el osteosarcoma parosteal convencional es un tumor óseo maligno poco común, que comprende el 4% de todos los osteosarcomas. Aunque es poco común, el osteosarcoma parosteal es el tipo más común de osteosarcoma de la superficie ósea. Presentamos las características clínicas, histológicas y de imagen de una variante histológica rara de un osteosarcoma parosteal, revisamos la literatura y enfatizamos la importancia de la correlación radio-patológica, así como la interpretación de una biopsia representativa para obtener el diagnóstico correcto. REPORTE DE CASO: mujer de 36 años inició su cuadro un año antes de su ingreso al hospital con aumento de volumen en rodilla izquierda y dolor. Los estudios de imagen mostraron una tumoración heterogénea yuxtacortical localizada en la superficie posterior de la metáfisis femoral distal. Se realizó biopsia incisional, con diagnóstico de osteosarcoma parosteal y se realizó resección quirúrgica amplia. De acuerdo con los hallazgos de la pieza quirúrgica se realizó el diagnóstico de osteosarcoma parosteal con componentes de condrosarcoma y liposarcoma de bajo grado. El conocimiento de esta rara variante de osteosarcoma parosteal puede llevar a los ortopedistas oncólogos a considerar otros componentes y proporcionar márgenes quirúrgicos adecuados. CONCLUSIÓN: presentamos las características clínicas, histológicas y de imagen de un osteosarcoma parosteal con componentes de liposarcoma y condrosarcoma de bajo grado.


Asunto(s)
Condrosarcoma , Liposarcoma , Osteosarcoma Yuxtacortical , Humanos , Femenino , Adulto , Liposarcoma/patología , Liposarcoma/cirugía , Liposarcoma/diagnóstico , Condrosarcoma/patología , Condrosarcoma/cirugía , Condrosarcoma/diagnóstico , Osteosarcoma Yuxtacortical/patología , Osteosarcoma Yuxtacortical/diagnóstico , Osteosarcoma Yuxtacortical/cirugía , Neoplasias Femorales/patología , Neoplasias Femorales/cirugía , Neoplasias Femorales/diagnóstico por imagen , Neoplasias Femorales/diagnóstico , Neoplasias Óseas/patología , Neoplasias Óseas/cirugía , Neoplasias Óseas/diagnóstico
7.
Br J Surg ; 111(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38747328

RESUMEN

BACKGROUND: Team diversity is recognized not only as an equity issue but also a catalyst for improved performance through diversity in knowledge and practices. However, team diversity data in healthcare are limited and it is not known whether it may affect outcomes in surgery. This study examined the association between anaesthesia-surgery team sex diversity and postoperative outcomes. METHODS: This was a population-based retrospective cohort study of adults undergoing major inpatient procedures between 2009 and 2019. The exposure was the hospital percentage of female anaesthetists and surgeons in the year of surgery. The outcome was 90-day major morbidity. Restricted cubic splines were used to identify a clinically meaningful dichotomization of team sex diversity, with over 35% female anaesthetists and surgeons representing higher diversity. The association with outcomes was examined using multivariable logistic regression. RESULTS: Of 709 899 index operations performed at 88 hospitals, 90-day major morbidity occurred in 14.4%. The median proportion of female anaesthetists and surgeons was 28 (interquartile range 25-31)% per hospital per year. Care in hospitals with higher sex diversity (over 35% female) was associated with reduced odds of 90-day major morbidity (OR 0.97, 95% c.i. 0.95 to 0.99; P = 0.02) after adjustment. The magnitude of this association was greater for patients treated by female anaesthetists (OR 0.92, 0.88 to 0.97; P = 0.002) and female surgeons (OR 0.83, 0.76 to 0.90; P < 0.001). CONCLUSION: Care in hospitals with greater anaesthesia-surgery team sex diversity was associated with better postoperative outcomes. Care in a hospital reaching a critical mass with over 35% female anaesthetists and surgeons, representing higher team sex-diversity, was associated with a 3% lower odds of 90-day major morbidity.


Asunto(s)
Grupo de Atención al Paciente , Complicaciones Posoperatorias , Humanos , Femenino , Estudios Retrospectivos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Adulto , Cirujanos/estadística & datos numéricos , Procedimientos Quirúrgicos Operativos/estadística & datos numéricos , Médicos Mujeres/estadística & datos numéricos
8.
Front Genet ; 15: 1278201, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38645486

RESUMEN

The high prevalence of obesity in Mexico starting from the early stages of life is concerning and represents a major public health problem. Genetic association studies have reported that single nucleotide variants (SNVs) in SIRT1, an NAD+-dependent deacetylase that plays an important role in the regulation of metabolic cellular functions, are associated with multiple metabolic disorders and the risk of obesity. In the present study, we analyzed the effect that the SNVs rs1467568 and rs7895833 of the SIRT1 gene may have on cardiometabolic risk factors in a young adult population from Mexico. A cross-sectional study was carried out with young adults between the ages of 18 and 25 who had a body mass index (BMI) greater than 18.5 kg/m2. This study included 1122 young adults who were classified into the normal weight (n = 731), overweight group (n = 277), and obesity group (n = 114) according to BMI of whom 405 and 404 volunteers were genotyped for rs1467568 and rs7895833 respectively using TaqMan probes through allelic discrimination assays. We found that the male sex carrying the G allele of rs7895833 had slightly lower BMI levels (p = 0.009). Furthermore, subjects carrying rs1467568 (G allele) showed a 34% lower probability of presenting with hyperbetalipoproteinemia where female carrying rs1467568 had lower levels of total cholesterol (p = 0.030), triglycerides (p = 0.026) and LDL cholesterol (p = 0.013). In conclusion, these findings suggest that the presence of both SNVs could have a non-risk effect against dyslipidemia in the Mexican population.

9.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 108-120, Mar-Abr. 2024. ilus, tab
Artículo en Español | IBECS | ID: ibc-231887

RESUMEN

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Fracturas de Cadera , Cadera/cirugía , España , Epidemiología Descriptiva , Estudios Prospectivos , Procedimientos Ortopédicos , Traumatología
10.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T108-T120, Mar-Abr. 2024. ilus, tab
Artículo en Inglés | IBECS | ID: ibc-231888

RESUMEN

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Fracturas de Cadera , Cadera/cirugía , España , Epidemiología Descriptiva , Estudios Prospectivos , Procedimientos Ortopédicos , Traumatología
11.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T121-T127, Mar-Abr. 2024. ilus, tab
Artículo en Inglés | IBECS | ID: ibc-231890

RESUMEN

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Asunto(s)
Humanos , Masculino , Femenino , Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Fracturas de Cadera , Cadera/cirugía , España , Epidemiología Descriptiva , Estudios Prospectivos , Procedimientos Ortopédicos , Traumatología
12.
Arch. Soc. Esp. Oftalmol ; 99(4): 165-168, abr. 2024. ilus
Artículo en Español | IBECS | ID: ibc-232137

RESUMEN

La cavitación intracoroidea es un hallazgo identificado con OCT descrito inicialmente en pacientes miopes, pero también aparece en pacientes no miopes. Puede presentarse tanto en el área peripapilar como en el polo posterior. El coloboma macular es un defecto del desarrollo embrionario del polo posterior, y en la OCT estructural es imprescindible la ausencia del epitelio pigmentario de la retina y de los vasos coroideos para su diagnóstico. Este caso presenta la cavitación intracoroidea circunscribiendo el coloboma macular, en ausencia de membrana intercalar. La imagen en face permite valorar la relación entre ambas estructuras, así como la magnitud de las mismas. (AU)


Intrachoroidal cavitation is a finding identified with OCT initially described in myopic patients, it also appears in non-myopic patients. It can occur in both the peripapillary area and the posterior pole. Macular coloboma is a defect of embryonic development of the posterior pole, in structural OCT the absence of the retinal pigment epithelium and choroidal vessels is essential. In this case, intrachoroidal cavitation circumscribes the macular coloboma, in the absence of an intercalary membrane. The face image allows us to assess the relationship between the two structures as well as their magnitude. (AU)


Asunto(s)
Humanos , Coloboma , Tomografía , Miopía Degenerativa , Cavitación , Oftalmología
13.
Appl Opt ; 63(4): 990-998, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38437396

RESUMEN

The dewetting of an azopolymer droplet, followed by the photostructuration of the evaporated droplet, is employed to create an amplitude mask. This straightforward process yields a large area featuring periodic micro- and nanostructures. The resulting pattern is utilized to generate a nondiffracting beam. Starting with a Gaussian beam illuminating the amplitude mask, the critical aspect is the production of a bright, ring-shaped beam with a high radius-to-width ratio and symmetric central laser spots, each with the same intensity. This alternative approach to shaping a laser beam is demonstrated as a rapid and cost-effective fabrication technique.

14.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(4): 165-168, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38309662

RESUMEN

Intrachoroidal cavitation is a finding identified with OCT initially described in myopic patients, it also appears in non-myopic patients. It can occur in both the peripapillary area and the posterior pole. Macular coloboma is a defect of embryonic development of the posterior pole, in structural OCT the absence of the retinal pigment epithelium and choroidal vessels is essential. In this case, intrachoroidal cavitation circumscribes the macular coloboma, in the absence of an intercalary membrane. The en face image allows us to assess the relationship between the two structures as well as their magnitude.


Asunto(s)
Enfermedades de la Coroides , Coloboma , Mácula Lútea/anomalías , Miopía , Humanos , Coroides/diagnóstico por imagen , Coloboma/diagnóstico por imagen , Enfermedades de la Coroides/diagnóstico por imagen
15.
16.
Rev Esp Cir Ortop Traumatol ; 68(2): 108-120, 2024.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37245634

RESUMEN

OBJECTIVES: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. MATERIAL AND METHODS: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. RESULTS: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min -12, max 3) to 1.29mm (SD: 1.96) after surgery registered with Mako®, with an increase of an average hip length of 5.64mm (SD: 3.35). Rx simple study results show a postoperative difference between both hips of 0.5±3.08mm, which is consistent with Mako® results. Native femoral offset was stable after surgery with a showing difference both pre and post operative of the intervened hip of 0.1mm (SD: 3.7), registered with Mako®. Preoperatory modified Harris punctuation was 41.6±13.3, improving to postoperative values of 74.6±9.7 after four months since the surgery. No complications were registered in immediate postoperative (4month). CONCLUSIONS: Total hip arthroplasty robot-assisted achieves an adequate precision and repeatability of the implant positioning and the postoperative hip dysmetry without showing an increase of associated complications to the technique applied. Surgery time, complications and functional results in a short-time period are similar to conventional techniques applied to great series previously published.

17.
Rev Esp Cir Ortop Traumatol ; 68(2): T108-T120, 2024.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37992860

RESUMEN

OBJECTIVES: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. MATERIAL AND METHODS: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4 months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. RESULTS: Average age was 67.2 years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative haemoglobin decrease of 3.08±1.08g/dl, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min -12, max 3) to 1.29mm (SD: 1.96) after surgery registered with Mako®, with an increase of an average hip length of 5.64mm (SD: 3.35). Rx simple study results show a postoperative difference between both hips of 0.5±3.08mm, which is consistent with Mako® results. Native femoral offset was stable after surgery with a showing difference both pre and post operative of the intervened hip of 0.1mm (SD: 3.7), registered with Mako®. Preoperatory modified Harris punctuation was 41.6±13.3, improving to postoperative values of 74.6±9.7 after four months since the surgery. No complications were registered in immediate postoperative (4 months). CONCLUSIONS: Total hip arthroplasty robot-assisted achieves an adequate precision and repeatability of the implant positioning and the postoperative hip dysmetry without showing an increase of associated complications to the technique applied. Surgery time, complications and functional results in a short-time period are similar to conventional techniques applied to great series previously published.

18.
Ann Oncol ; 35(3): 267-275, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38145866

RESUMEN

Current evaluation of treatment response in solid tumors depends on dynamic changes in tumor diameters as measured by imaging. However, these changes can only be detected when there are enough macroscopic changes in tumor volume, which limits the usability of radiological response criteria in evaluating earlier stages of disease response and necessitates much time to lapse for gross changes to be notable. One promising approach is to incorporate dynamic changes in circulating tumor DNA (ctDNA), which occur early in the course of therapy and can predict tumor responses weeks before gross size changes manifest. However, several issues need to be addressed before recommending the implementation of ctDNA response criteria in daily clinical practice such as clinical, biological, and regulatory challenges and, most importantly, the need to standardize/harmonize detection methods and ways to define ctDNA response and/or progression for precision oncology. Herein, we review the use of liquid biopsy (LB) to evaluate response in solid tumors and propose a plan toward standardization of LB-RECIST.


Asunto(s)
ADN Tumoral Circulante , Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/genética , Criterios de Evaluación de Respuesta en Tumores Sólidos , Medicina de Precisión , Biopsia Líquida , ADN Tumoral Circulante/genética , Biomarcadores de Tumor/genética
19.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(6): 458-462, Nov-Dic. 2023. ilus
Artículo en Español | IBECS | ID: ibc-227609

RESUMEN

Introducción: Las metástasis vertebrales son un problema muy frecuente y asocian un deterioro importante de la calidad de vida en los pacientes oncológicos. El objetivo de esta revisión es determinar el encaje de las técnicas quirúrgicas mínimamente invasivas dentro del manejo de esta entidad. Métodos: Se realizó una revisión bibliográfica en las bases de datos Google Scholar, PubMed, Scopus y Cochrane. Se revisaron los artículos publicados en los últimos 10 años que fueran de una relevancia y calidad adecuadas. Resultados: Tras el cribado de los 2.184 trabajos identificados inicialmente en las distintas bases de datos, se incluyeron un total de 24 artículos en esta revisión. Conclusión: La cirugía mínimamente invasiva de columna es especialmente útil en pacientes oncológicos frágiles con metástasis vertebrales por la reducida comorbilidad que presentan las técnicas que se engloban en ella en comparación con la de la cirugía abierta convencional. Los avances en tecnología aplicada a la cirugía, como la navegación y la robótica, mejoran la precisión y reducen las complicaciones de esta técnica.(AU)


Background: Spinal metastases are a very common problem which dramatically affects the quality of life of cancer patients. The objective of this review is to address the issue of how minimally invasive surgery can play an important role in treating this pathology. Methods: A literature review was performed, searching in the Google Scholar, PubMed, Scopus and Cochrane databases. Relevant and quality papers published within the last 10 years were included in the review. Results: After screening the 2184 initially identified registers, a total of 24 articles were included for review. Conclusion: Minimally invasive spine surgery is specially convenient for fragile cancer patients with spinal metastases, because of its reduced comorbidity compared to conventional open surgery. Technological advances in surgery, such as navigation and robotics, improve accuracy and safety in this technique.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Columna Vertebral/cirugía , Metástasis de la Neoplasia/tratamiento farmacológico , Neoplasias de la Columna Vertebral/cirugía , Procedimientos Ortopédicos , Ortopedia , Traumatología
20.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(6): S458-S462, Nov-Dic. 2023. ilus
Artículo en Inglés | IBECS | ID: ibc-227610

RESUMEN

Introducción: Las metástasis vertebrales son un problema muy frecuente y asocian un deterioro importante de la calidad de vida en los pacientes oncológicos. El objetivo de esta revisión es determinar el encaje de las técnicas quirúrgicas mínimamente invasivas dentro del manejo de esta entidad. Métodos: Se realizó una revisión bibliográfica en las bases de datos Google Scholar, PubMed, Scopus y Cochrane. Se revisaron los artículos publicados en los últimos 10 años que fueran de una relevancia y calidad adecuadas. Resultados: Tras el cribado de los 2.184 trabajos identificados inicialmente en las distintas bases de datos, se incluyeron un total de 24 artículos en esta revisión. Conclusión: La cirugía mínimamente invasiva de columna es especialmente útil en pacientes oncológicos frágiles con metástasis vertebrales por la reducida comorbilidad que presentan las técnicas que se engloban en ella en comparación con la de la cirugía abierta convencional. Los avances en tecnología aplicada a la cirugía, como la navegación y la robótica, mejoran la precisión y reducen las complicaciones de esta técnica.(AU)


Background: Spinal metastases are a very common problem which dramatically affects the quality of life of cancer patients. The objective of this review is to address the issue of how minimally invasive surgery can play an important role in treating this pathology. Methods: A literature review was performed, searching in the Google Scholar, PubMed, Scopus and Cochrane databases. Relevant and quality papers published within the last 10 years were included in the review. Results: After screening the 2184 initially identified registers, a total of 24 articles were included for review. Conclusion: Minimally invasive spine surgery is specially convenient for fragile cancer patients with spinal metastases, because of its reduced comorbidity compared to conventional open surgery. Technological advances in surgery, such as navigation and robotics, improve accuracy and safety in this technique.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Columna Vertebral/cirugía , Metástasis de la Neoplasia/tratamiento farmacológico , Neoplasias de la Columna Vertebral/cirugía , Procedimientos Ortopédicos , Ortopedia , Traumatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA