Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
Echocardiography ; 41(5): e15821, 2024 May.
Article En | MEDLINE | ID: mdl-38706373

INTRODUCTION: Doppler-derived pulmonary pulse transit time (pPTT) is an auspicious hemodynamic marker in chronic pulmonary diseases. The aim is to compare four distinct pPTT measurements and its relation to right cardiac and pulmonary function. METHODS: Prospectively, 25 chronic obstructive pulmonary disease (COPD) patients (four patients excluded) and 32 healthy subjects underwent repeated distinct pPTT measurements, standard echocardiography, and pulmonary function testing on the same day. pPTT was defined as the interval from the R or Q-wave in the electrocardiogram to the corresponding pulse wave Doppler peak late systolic (S) 2 or diastolic (D) pulmonary vein flow velocity (pPTT R-S, Q-S, R-D, Q-D). Reproducibility was assessed using Bland-Altman analysis, coefficient of variation (COV), intraclass correlation coefficient (ICC), and power calculations. Associations with right ventricular RV tissue and pulse wave Doppler velocities (RV E', RV S', RV A', RV E, RV A, RV E/E', RV E/A), TAPSE, right ventricular fractional area change, left ventricular systolic and diastolic function (LV ejection fraction, E, A, E/A, E/E', septal E', lateral E'), LA diameters, as well as forced expiratory volume in 1 s, forced vital capacity (FVC) predicted (%), and in liters were analyzed. RESULTS: There was no significant difference and no bias between pPTT measures (p range: .1-.9). COV was in COPD 1.2%-2.3%, in healthy subjects 1.0%-3.1%. ICC ranged from .92 (COPD) to .96 (healthy subjects). In COPD significant correlations were found for pPTT R-S, Q-S and R-D with RV E`, (all > ρ: .49, < p = .0364), pPTT R-S, Q-S with RV E/E` (both > ρ: .49, < p = .0291), pPTT Q-S with RV S´ (ρ: .58, p = .0134), RV A (ρ: .59, p = .0339) and heart rate > ρ: -.39, < p = .0297). pPTT R-S, R-D showed significant correlations with FVC predicted (%) (ρ: .48 p = .0224) and FVC (l) (ρ:.47 p = .0347). CONCLUSIONS: All pPTT measures exhibited high reproducibility. In COPD patients pPTT measures correlate with diastolic right ventricular function. Defining Q as starting point seems clinically advantageous considering electromechanical desynchrony in patients with conduction disorders.


Echocardiography, Doppler , Pulmonary Disease, Chronic Obstructive , Pulse Wave Analysis , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Male , Female , Reproducibility of Results , Pulse Wave Analysis/methods , Prospective Studies , Echocardiography, Doppler/methods , Aged , Middle Aged , Respiratory Function Tests/methods , Blood Flow Velocity/physiology
2.
Clin Exp Med ; 24(1): 37, 2024 Feb 17.
Article En | MEDLINE | ID: mdl-38367089

Melanoma differentiation-associated protein 5 (MDA5) antibody positive amyopathic dermatomyositis (DM) is a rare inflammatory disease. So far, there is no official treatment guideline in MDA5 amyopathic dermatomyositis, but early and aggressive immunosuppressive combination treatment can induce a stable remission. We retrospectively analyzed a cohort of eight patients (male n = 5) that were diagnosed with MDA5-positive amyopathic DM. Patient data comprised demographics, CT-guided diagnosis of pulmonary involvement, pulmonary function testing including forced vital capacity (FVC) and diffusing capacity for carbon monoxide (DLCO) data on baseline and mean long-term follow-up of 51 months (24-92 months) to evaluate treatment strategies. Depending on severity of organ involvement treatments were individualized including cyclophosphamide, immunoglobulins and plasmapheresis. Simultaneously, oral treatment with tacrolimus was commenced in four of the eight patients. Most patients received remission maintenance therapy with a combination of tacrolimus, rituximab and low dose steroids. In all patients, improvement in FVC was recorded and five patients achieved an improvement in DLCO. An improvement in the CT imaging morphological findings was observed in four patients. Awareness for the entirety of all clinical and disease-related findings of amyopathic DM is crucial, and remission maintenance is often achieved with a combination of tacrolimus and rituximab.


Dermatomyositis , Lung Diseases, Interstitial , Tacrolimus , Humans , Male , Female , Retrospective Studies , Tacrolimus/therapeutic use , Rituximab , Interferon-Induced Helicase, IFIH1 , Autoantibodies
3.
PLoS One ; 18(4): e0278850, 2023.
Article En | MEDLINE | ID: mdl-37014837

BACKGROUND: While postoperative malrotation in the subtrochanteric region is a well-known problem, malrotation after osteosynthesis in proximal femoral fractures has not been extensively studied. In this context, many methods for perioperatively assessment of femoral torsion have been described, but none of them is applicable in the basicervical region of the proximal femur. As an important difference in femoral neck fractures, the discontinuous neck fails to serve as a significant "pointer" for measurements and malfunctions to be placed in relation to the condylar plane. Considering postoperative maltorsion at any location as a substantial negative effect on patients' outcome and functional expectations, precise and patient-friendly rotation measurement standards in femoral neck fractures are desired in clinical practice. Recently, a novel computed tomography (CT) based geometric technique was described named "direct measurement" with promising results covering this diagnostic disparity, but still requires validation. Thus, we aimed to validate the previously described technique using a controlled range of displacement in a femoral neck fracture Sawbone® model. METHODS AND FINDINGS: A goniometer was designed to set retro- and anteversion of the proximal femur in a reproducible manner. Prospectively, all femurs underwent a CT scan and were measured 3D for displacement. The interclass correlation between the CT measurements and the goniometer measurements was calculated and was found to be very high (1.00, 95% confidence interval: 0.99-1.00; p < 0.001). For the mean of all measurements, the Pearson's correlation was 1.00 (p < 0.001). No significant differences in the measurements of both investigators were observed, with 20° of retroversion not significant (-1.20 ± 1.71; 95% confidence interval: -2.43-0.03; p = 0.054). CONCLUSION: This CT-based 3D measurement technique may allow for perioperative malrotation assessment in basicervical femoral neck fractures and appears to be feasible in femoral neck fractures when it comes to rare cases of osteosynthesis. Further investigations are still needed to define the thresholds of malrotation provoking functional impairment after osteosynthesis in basicervical femoral neck fractures.


Femoral Fractures , Femoral Neck Fractures , Humans , Femur/surgery , Tomography, X-Ray Computed/methods , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Fracture Fixation, Internal
4.
Magn Reson Med ; 85(2): 912-925, 2021 02.
Article En | MEDLINE | ID: mdl-32926451

PURPOSE: To test the feasibility of 3D phase-resolved functional lung (PREFUL) MRI in healthy volunteers and patients with chronic pulmonary disease, to compare 3D to 2D PREFUL, and to investigate the required temporal resolution to obtain stable 3D PREFUL measurement. METHODS: Sixteen participants underwent MRI using 2D and 3D PREFUL. Retrospectively, the spatial resolution of 3D PREFUL (4 × 4 × 4 mm3 ) was decreased to match the spatial resolution of 2D PREFUL (4 × 4 × 15 mm3 ), abbreviated as 3Dlowres . In addition to regional ventilation (RVent), flow-volume loops were computed and rated by a cross-correlation (CC). Ventilation defect percentage (VDP) maps were obtained. RVent, CC, VDPRVent , and VDPCC were compared for systematic differences between 2D, 3Dlowres , and 3D PREFUL. Dividing the 3D PREFUL data into 4- (≈ 20 phases), 8- (≈ 40 phases), and 12-min (≈ 60 phases) acquisition pieces, the ventilation parameter maps, including the heterogeneity of ventilation time to peak, were tested regarding the required temporal resolution. RESULTS: RVent, CC, VDPRVent , and VDPCC  presented significant correlations between 2D and 3D PREFUL (r = 0.64-0.94). CC and VDPCC  of 2D and 3Dlowres  PREFUL were significantly different (P < .0113). Comparing 3Dlowres  and 3D PREFUL, all parameters were found to be statistically different (P < .0045). CONCLUSION: 3D PREFUL MRI depicts the whole lung volume and breathing cycle with superior image resolution and with likely more precision compared to 2D PREFUL. Furthermore, 3D PREFUL is more sensitive to detect regions of hypoventilation and ventilation heterogeneity compared to 3Dlowres  PREFUL, which is important for early detection and improved monitoring of patients with chronic lung disease.


Lung , Magnetic Resonance Imaging , Healthy Volunteers , Humans , Lung/diagnostic imaging , Pulmonary Ventilation , Respiration , Retrospective Studies
...