1.
Cancer Lett ; 381(2): 323-30, 2016 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-27502168

RESUMEN

Antibody-drug conjugates (ADCs) combine the potency of cytotoxic drugs with the specificity of monoclonal antibodies (mAbs). Most ADCs are currently generated by the nonspecific conjugation of drug-linker reagents to certain amino acid residues in mAbs, resulting in a heterogeneous product. To overcome this limitation and prepare ADCs with a defined stoichiometry, we use SNAP-tag technology as an alternative conjugation strategy. This allows the site-specific conjugation of O(6)-benzylguanine (BG)-modified small molecules to SNAP-tag fusion proteins. To demonstrate the suitability of this system for the preparation of novel recombinant ADCs, here we conjugated SNAP-tagged single chain antibody fragments (scFvs) to a BG-modified version of auristatin F (AURIF). We used two scFv-SNAP fusion proteins targeting members of the epidermal growth factor receptor (EGFR) family that are frequently overexpressed in breast cancer. The conjugation of BG-AURIF to EGFR-specific 425(scFv)-SNAP and HER2-specific αHER2(scFv)-SNAP resulted in two potent recombinant ADCs that specifically killed breast cancer cell lines by inducing apoptosis when applied at nanomolar concentrations. These data confirm that SNAP-tag technology is a promising tool for the generation of novel recombinant ADCs.


Asunto(s)
Antineoplásicos/farmacología , Neoplasias de la Mama/tratamiento farmacológico , Receptores ErbB/inmunología , Guanina/análogos & derivados , Inmunoterapia/métodos , Inmunotoxinas/farmacología , Oligopéptidos/farmacología , Proteínas Q-SNARE/farmacología , Receptor ErbB-2/inmunología , Anticuerpos de Cadena Única/farmacología , Animales , Apoptosis/efectos de los fármacos , Neoplasias de la Mama/inmunología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Puntos de Control del Ciclo Celular/efectos de los fármacos , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Estabilidad de Medicamentos , Receptores ErbB/metabolismo , Guanina/farmacología , Humanos , Inmunotoxinas/inmunología , Concentración 50 Inhibidora , Ratones , Proteínas Q-SNARE/inmunología , Receptor ErbB-2/metabolismo , Proteínas Recombinantes de Fusión/farmacología , Transducción de Señal/efectos de los fármacos , Anticuerpos de Cadena Única/inmunología
2.
Monoclon Antib Immunodiagn Immunother ; 35(3): 141-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27187007

RESUMEN

SNAP-tag technology allows recombinant proteins to be covalently labeled to O(6)-benzylguanine (BG)-modified substrates with 1:1 stoichiometry. By attaching according fluorophores, this method is ideally suited for in vitro and in vivo imaging, as well as protein interaction analyses. Fluorophores modified with BG react with the SNAP-tag, whereas those modified with O(2)-benzylcytosine (BC) conjugate to a more recent derivative known as the CLIP-tag. The orthogonal substrate specificity of the SNAP- and CLIP-tags extends the range of applications by allowing double labeling. We previously developed a monoclonal antibody (mAb) that recognizes both tags. In this study, we describe a new mAb, which is specific for the SNAP-tag alone. Therefore, this mAb allows discrimination between SNAP- and CLIP-tags within a broad range of immunological methods, including enzyme-linked immunosorbent assays, western blotting, flow cytometry, and immunohistochemistry.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Guanina/análogos & derivados , Proteínas Recombinantes de Fusión/aislamiento & purificación , Anticuerpos Monoclonales/química , Ensayo de Inmunoadsorción Enzimática , Citometría de Flujo , Colorantes Fluorescentes/química , Guanina/química , Proteínas Recombinantes de Fusión/genética , Proteínas Recombinantes de Fusión/inmunología
3.
Langmuir ; 31(6): 2043-50, 2015 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-25654744

RESUMEN

Previous work has indicated that surface imprinted polymers (SIPs) allow for highly specific cell detection through macromolecular cell imprints. The combination of SIPs with a heat-transfer-based read-out technique has led to the development of a selective, label-free, low-cost, and user-friendly cell detection assay. In this study, the breast cancer cell line ZR-75-1 is used to assess the potential of the platform for monitoring the quality of a cell culture in time. For this purpose, we show that the proposed methodology is able to discriminate between the original cell line (adherent growth, ZR-75-1a) and a descendant cell line (suspension growth, ZR-75-1s). Moreover, ZR-75-1a cells were cultured for a prolonged period of time and analyzed using the heat-transfer method (HTM) at regular time intervals. The results of these experiments demonstrate that the thermal resistance (Rth) signal decays after a certain number of cell culture passages. This can likely be attributed to a compromised quality of the cell culture due to cross-contamination with the ZR-75-1s cell line, a finding that was confirmed by classical STR DNA profiling. The cells do not express the same functional groups on their membrane, resulting in a weaker bond between cell and imprint, enabling cell removal by mechanical friction, provided by flushing the measuring chamber with buffer solution. These findings were further confirmed by HTM and illustrate that the biomimetic sensor platform can be used as an assay for monitoring the quality of cell cultures in time.


Asunto(s)
Biomimética/métodos , Calor , Impresión Molecular , Sondas Moleculares/síntesis química , Polímeros/síntesis química , Técnicas de Cultivo de Célula , Línea Celular Tumoral , Humanos , Repeticiones de Microsatélite , Sondas Moleculares/metabolismo , Polímeros/metabolismo , Control de Calidad , Propiedades de Superficie
4.
Monoclon Antib Immunodiagn Immunother ; 33(6): 369-77, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25545205

RESUMEN

Monoclonal antibodies are produced in cultured hybridoma cell lines, but these cells tend to be unstable; it is therefore necessary to rescue the corresponding genetic information. Here we describe an improved method for the amplification of antibody variable gene (V-gene) information from murine hybridoma cells using a panel of specific, non-degenerate primers. This primer set allows sequences to be rescued from all murine V-genes, except the lambda light chain genes, which rarely contribute to murine immune diversity. We tested the primers against a range of antibodies and recovered specific amplification products in all cases. The heavy and light chain variable regions were subsequently joined by a two-step cloning strategy or by splice overlap extension PCR.


Asunto(s)
Anticuerpos Monoclonales de Origen Murino/genética , Cartilla de ADN/genética , Hibridomas/inmunología , Región Variable de Inmunoglobulina/genética , Proteínas Recombinantes/genética , Animales , Anticuerpos Monoclonales de Origen Murino/inmunología , Secuencia de Bases , Western Blotting , Línea Celular , Clonación Molecular/métodos , ADN Complementario/biosíntesis , Electroforesis en Gel de Poliacrilamida , Ensayo de Inmunoadsorción Enzimática , Citometría de Flujo , Vectores Genéticos/genética , Células HEK293 , Humanos , Ratones , Datos de Secuencia Molecular , Reacción en Cadena de la Polimerasa , Proteínas Recombinantes/inmunología , Análisis de Secuencia de ADN
5.
Langmuir ; 30(12): 3631-9, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24606112

RESUMEN

Surface-imprinted polymers allow for specific cell detection based on simultaneous recognition of the cell shape, cell size, and cell membrane functionalities by macromolecular cell imprints. In this study, the specificity of detection and the detection sensitivity for target cells within a pool of non-target cells were analyzed for a cell-specific surface-imprinted polymer combined with a heat-transfer-based read-out technique (HTM). A modified Chinese hamster ovarian cell line (CHO-ldlD) was used as a model system on which the transmembrane protein mucin-1 (MUC1) could be excessively expressed and for which the occurrence of MUC1 glycosylation could be controlled. In specific cancer cells, the overexpressed MUC1 protein typically shows an aberrant apical distribution and glycosylation. We show that surface-imprinted polymers discriminate between cell types that (1) only differ in the expression of a specific membrane protein (MUC1) or (2) only differ in the membrane protein being glycosylated or not. Moreover, surface-imprinted polymers of cells carrying different glycoforms of the same membrane protein do target both types of cells. These findings illustrate the high specificity of cell detection that can be reached by the structural imprinting of cells in polymer layers. Competitiveness between target and non-target cells was proven to negatively affect the detection sensitivity of target cells. Furthermore, we show that the detection sensitivity can be increased significantly by repetitively exposing the surface to the sample and eliminating non-specifically bound cells by flushing between consecutive cell exposures.


Asunto(s)
Calor , Impresión Molecular , Poliuretanos/química , Animales , Células CHO , Células Cultivadas , Cricetulus , Glicosilación , Microscopía Fluorescente , Mucina-1/biosíntesis , Mucina-1/química , Mucina-1/metabolismo , Poliuretanos/metabolismo , Propiedades de Superficie
6.
Biosens Bioelectron ; 26(5): 1895-901, 2011 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-20400289

RESUMEN

The importance of early diagnosis devices increased continuously in the last two decades and plays an important role in medical care. Early stage diagnosis of e.g. ovarian cancer, HCV-infection or HIV-infection increased the survival rate of patients significantly. In parallel there is a trend leaving centralized diagnostic laboratories in order to get closer to the patient to perform analysis of even complex parameters in the field. This often saves time, increases the prognosis of the patient significantly and is cheaper in many cases. In this study we employ a rapid and cost-effective detection system based on electrical biochip technology for decentralized detection of anti-HCV Core immunoglobulins (HCV antibodies). In this system the qualitative and quantitative detection of virus-specific antibodies is done by an ELISA directly on a gold electrode array utilizing HCV Core as capture antigen. The biochip allows antibody detection within 20 min. Signal amplification was done by enzyme labelling and by "Single Electrode Redox Cycling". This method enhances current signals up to 40-fold in comparison to simple oxidation. The sensitivity of this approach is therefore comparable to a standard microtiter plate based ELISA with a 9-fold saving of assay time. This biochip system allows serum or whole blood analysis with no signal loss or increasing background caused by the red blood cells. Fields of application can be hospital emergency units where only single detections have to be conducted in a quick manner or by the general practitioner.


Asunto(s)
Técnicas Biosensibles/instrumentación , Conductometría/instrumentación , Ensayo de Inmunoadsorción Enzimática/instrumentación , Anticuerpos contra la Hepatitis C/sangre , Inmunoensayo/instrumentación , Inmunoglobulinas/sangre , Diseño de Equipo , Análisis de Falla de Equipo , Anticuerpos contra la Hepatitis C/inmunología , Humanos , Inmunoglobulinas/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA