Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cureus ; 16(2): e53701, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38455812

RESUMEN

Ankyloglossia can be related to a number of complications, such as breastfeeding difficulties or alterations in craniofacial development. Treatment can involve surgery to correct the altered lingual frenulum and can be performed by various techniques. The purpose of this paper is to present two case reports of ankyloglossia in pediatric patients of different ages, the diagnostic criteria, and the treatment decision rationale, which led to a lingual frenotomy performed with a diode laser.

2.
Environ Toxicol Chem ; 42(5): 1075-1084, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36848320

RESUMEN

Bioconcentration factors (BCFs) are determined by fish flow-through tests performed according to Organisation for Economic Co-operation and Development test guideline 305. These are time-consuming and expensive and use a large number of animals. An alternative test design using the freshwater amphipod Hyalella azteca for bioconcentration studies has been recently developed and demonstrated a high potential. For bioconcentration studies using H. azteca, male amphipods are preferred compared with female organisms. Manual sexing of male adult amphipods is, however, time-consuming and requires care and skill. A new fully automatic sorting and dispensing machine for H. azteca based on image analysis has recently been developed by the company Life Science Methods. Nevertheless, an anesthesia step is necessary prior to the automatic selection. In the present study, we show that a single-pulse of 90 min of tricaine at the concentration of 1 g/L can be used and is recommended to select H. azteca males manually or automatically using the sorting machine. In the second part, we demonstrate that the machine has the ability to select, sort, and disperse the males of a culture batch of H. azteca as efficiently as manual procedures. In the last part of the study, BCFs of two organic substances were evaluated using the H. azteca bioconcentration test (HYBIT) protocol, with an anesthetizing step and robotic selection compared with manual selection without an anesthetizing step. The different BCF values obtained were in accordance with those indicated in the literature and showed that an anesthetizing step had no effect on the BCF values. Therefore, these data validated the interest in this sorting machine for selecting males to perform bioconcentrations studies with H. azteca. Environ Toxicol Chem 2023;42:1075-1084. © 2023 SETAC.


Asunto(s)
Anfípodos , Análisis para Determinación del Sexo , Animales , Femenino , Masculino , Bioacumulación , Agua Dulce , Análisis para Determinación del Sexo/instrumentación , Análisis para Determinación del Sexo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...