Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Struct Dyn ; 10(6): 064501, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37941994

RESUMEN

The evolution of charge carriers in photoexcited room temperature ZnO nanoparticles in solution is investigated using ultrafast ultraviolet photoluminescence spectroscopy, ultrafast Zn K-edge absorption spectroscopy, and ab initio molecular dynamics (MD) simulations. The photoluminescence is excited at 4.66 eV, well above the band edge, and shows that electron cooling in the conduction band and exciton formation occur in <500 fs, in excellent agreement with theoretical predictions. The x-ray absorption measurements, obtained upon excitation close to the band edge at 3.49 eV, are sensitive to the migration and trapping of holes. They reveal that the 2 ps transient largely reproduces the previously reported transient obtained at 100 ps time delay in synchrotron studies. In addition, the x-ray absorption signal is found to rise in ∼1.4 ps, which we attribute to the diffusion of holes through the lattice prior to their trapping at singly charged oxygen vacancies. Indeed, the MD simulations show that impulsive trapping of holes induces an ultrafast expansion of the cage of Zn atoms in <200 fs, followed by an oscillatory response at a frequency of ∼100 cm-1, which corresponds to a phonon mode of the system involving the Zn sub-lattice.

2.
Sci Rep ; 6: 33292, 2016 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-27620067

RESUMEN

X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Herein we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state.

3.
Biol Trace Elem Res ; 158(1): 22-8, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24573405

RESUMEN

The chemotherapy and photon radiotherapy are the most often applied methods in treatment of the cancer diseases because of their effectiveness and high cure rates. Apart from eligible destruction of the tumour, one of the side effects of these treatment methods is possible modification of main and trace element concentration in different human tissues and fluids. In this paper, the copper (Cu) level in human serum was determined by total reflection X-ray fluorescence method in 142 chemotherapy patients and in 44 healthy persons being a control group. The Cu concentration in the chemotherapy group was found to be on the level 1.78 ± 0.909 mg/L, while in the control group, it was 1.08 ± 0.551 mg/L. Performed measurements allowed for calculation of the parameters of copper concentration distribution (mean value, standard deviation, median) for both analysed groups. The theoretical nature of the concentration distribution was tested and found as a log-normal distribution (control group) and a log-stable distribution (chemotherapy group). The copper concentration distributions for both studied group were statistically compared using Kolmogorov-Smirnov test, and the conclusion was that the distributions are statistically different. Serum Cu levels were significantly higher in the chemotherapy group than in the control group. Taking into account the results for the control group, the copper concentration reference quantile ranges in human serum were obtained. The values of the mean, median and other quantiles determined in this case can be applied in two-group comparison studies. The obtained results can be used as a diagnostic tool for chemotherapy patients.


Asunto(s)
Cobre/sangre , Neoplasias/sangre , Neoplasias/tratamiento farmacológico , Espectrometría por Rayos X/métodos , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...