Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Ultrasound Med Biol ; 50(11): 1716-1723, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39174376

RESUMEN

OBJECTIVE: A deep neural network (DNN) was trained to generate a multiparametric ultrasound (mpUS) volume from four input ultrasound-based modalities (acoustic radiation force impulse [ARFI] imaging, shear wave elasticity imaging [SWEI], quantitative ultrasound-midband fit [QUS-MF], and B-mode) for the detection of prostate cancer. METHODS: A DNN was trained using co-registered ARFI, SWEI, MF, and B-mode data obtained in men with biopsy-confirmed prostate cancer prior to radical prostatectomy (15 subjects, comprising 980,620 voxels). Data were obtained using a commercial scanner that was modified to allow user control of the acoustic beam sequences and provide access to the raw image data. For each subject, the index lesion and a non-cancerous region were manually segmented using visual confirmation based on whole-mount histopathology data. RESULTS: In a prostate phantom, the DNN increased lesion contrast-to-noise ratio (CNR) compared to a previous approach that used a linear support vector machine (SVM). In the in vivo test datasets (n = 15), the DNN-based mpUS volumes clearly portrayed histopathology-confirmed prostate cancer and significantly improved CNR compared to the linear SVM (2.79 ± 0.88 vs. 1.98 ± 0.73, paired-sample t-test p < 0.001). In a sub-analysis in which the input modalities to the DNN were selectively omitted, the CNR decreased with fewer inputs; both stiffness- and echogenicity-based modalities were important contributors to the multiparametric model. CONCLUSION: The findings from this study indicate that a DNN can be optimized to generate mpUS prostate volumes with high CNR from ARFI, SWEI, MF, and B-mode and that this approach outperforms a linear SVM approach.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Redes Neurales de la Computación , Neoplasias de la Próstata , Ultrasonografía , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Próstata/diagnóstico por imagen , Persona de Mediana Edad , Fantasmas de Imagen , Anciano , Aprendizaje Profundo
2.
Ultrasound Med Biol ; 50(6): 788-796, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38461036

RESUMEN

OBJECTIVE: Spontaneous echo contrast (SEC) is a vascular ultrasound finding associated with increased thromboembolism risk. However, identification requires expert determination and clinician time to report. We developed a deep learning model that can automatically identify SEC. Our model can be applied retrospectively without deviating from routine clinical practice. The retrospective nature of our model means future works could scan archival data to opportunistically correlate SEC findings with documented clinical outcomes. METHODS: We curated a data set of 801 archival acquisitions along the femoral vein from 201 patients. We used a multisequence convolutional neural network (CNN) with ResNetv2 backbone and visualized keyframe importance using soft attention. We evaluated SEC prediction performance using an 80/20 train/test split. We report receiver operating characteristic area under the curve (ROC-AUC), along with the Youden threshold-associated sensitivity, specificity, F1 score, true negative, false negative, false positive and true positive. RESULTS: Using soft attention, we can identify SEC with an AUC of 0.74, sensitivity of 0.73 and specificity of 0.68. Without soft attention, our model achieves an AUC of 0.69, sensitivity of 0.71 and specificity of 0.60. Additionally, we provide attention visualizations and note that our model assigns higher attention score to ultrasound frames containing more vessel lumen. CONCLUSION: Our multisequence CNN model can identify the presence of SEC from ultrasound keyframes with an AUC of 0.74, which could enable screening applications and enable more SEC data discovery. The model does not require the expert intervention or additional clinician reporting time that are currently significant barriers to SEC adoption. Model and processed data sets are publicly available at https://github.com/Ouwen/automatic-spontaneous-echo-contrast.


Asunto(s)
Redes Neurales de la Computación , Ultrasonografía , Humanos , Ultrasonografía/métodos , Estudios Retrospectivos , Vena Femoral/diagnóstico por imagen , Aprendizaje Profundo , Femenino , Sensibilidad y Especificidad , Masculino
3.
J Mech Behav Biomed Mater ; 150: 106302, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38160641

RESUMEN

Skeletal muscle is a complex tissue, exhibiting not only direction-dependent material properties (commonly modeled as a transversely isotropic material), but also changes in observed material properties due to factors such as contraction and passive stretch. In this work, we evaluated the effect of muscle passive stretch on shear wave propagation along and across the muscle fibers using a rotational 3D shear wave elasticity imaging system and automatic analysis methods. We imaged the vastus lateralis of 10 healthy volunteers, modulating passive stretch by imaging at 8 different knee flexion angles (controlled by a BioDex system). In addition to demonstrating the ability of this acquisition and automatic processing system to estimate muscle shear moduli over a range of values, we evaluated potential higher order biomarkers for muscle health that capture the change in muscle stiffness along and across the fibers with changing knee flexion. The median within-subject variability of these biomarkers is found to be <16%, suggesting promise as a repeatable clinical metric. Additionally, we report an unexpected observation: that shear wave signal amplitude along the fibers increases with increasing flexion and muscle stiffness, which is not predicted by transversely isotropic (TI) material simulations. This observation may point to an additional potential biomarker for muscle health or inform other material modeling choices for muscle.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Músculo Cuádriceps , Humanos , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/fisiología , Músculo Esquelético/fisiología , Elasticidad , Fibras Musculares Esqueléticas , Biomarcadores , Diagnóstico por Imagen de Elasticidad/métodos
4.
Ear Hear ; 44(5): 1262-1270, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37318215

RESUMEN

OBJECTIVE: Childhood hearing loss has well-known, lifelong consequences. Infection-related hearing loss disproportionately affects underserved communities yet can be prevented with early identification and treatment. This study evaluates the utility of machine learning in automating tympanogram classifications of the middle ear to facilitate layperson-guided tympanometry in resource-constrained communities. DESIGN: Diagnostic performance of a hybrid deep learning model for classifying narrow-band tympanometry tracings was evaluated. Using 10-fold cross-validation, a machine learning model was trained and evaluated on 4810 pairs of tympanometry tracings acquired by an audiologist and layperson. The model was trained to classify tracings into types A (normal), B (effusion or perforation), and C (retraction), with the audiologist interpretation serving as reference standard. Tympanometry data were collected from 1635 children from October 10, 2017, to March 28, 2019, from two previous cluster-randomized hearing screening trials (NCT03309553, NCT03662256). Participants were school-aged children from an underserved population in rural Alaska with a high prevalence of infection-related hearing loss. Two-level classification performance statistics were calculated by treating type A as pass and types B and C as refer. RESULTS: For layperson-acquired data, the machine-learning model achieved a sensitivity of 95.2% (93.3, 97.1), specificity of 92.3% (91.5, 93.1), and area under curve of 0.968 (0.955, 0.978). The model's sensitivity was greater than that of the tympanometer's built-in classifier [79.2% (75.5, 82.8)] and a decision tree based on clinically recommended normative values [56.9% (52.4, 61.3)]. For audiologist-acquired data, the model achieved a higher AUC of 0.987 (0.980, 0.993), had an equivalent sensitivity of 95.2 (93.3, 97.1), and a higher specificity of 97.7 (97.3, 98.2). CONCLUSIONS: Machine learning can detect middle ear disease with comparable performance to an audiologist using tympanograms acquired either by an audiologist or a layperson. Automated classification enables the use of layperson-guided tympanometry in hearing screening programs in rural and underserved communities, where early detection of treatable pathology in children is crucial to prevent the lifelong adverse effects of childhood hearing loss.


Asunto(s)
Sordera , Aprendizaje Profundo , Pérdida Auditiva , Niño , Humanos , Pérdida Auditiva/diagnóstico , Pruebas de Impedancia Acústica , Oído Medio
5.
Ultrason Imaging ; 45(4): 175-186, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37129257

RESUMEN

This study demonstrates the implementation of a shear wave reconstruction algorithm that enables concurrent acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) of prostate cancer and zonal anatomy. The combined ARFI/SWEI sequence uses closely spaced push beams across the lateral field of view and simultaneously tracks both on-axis (within the region of excitation) and off-axis (laterally offset from the excitation) after each push beam. Using a large number of push beams across the lateral field of view enables the collection of higher signal-to-noise ratio (SNR) shear wave data to reconstruct the SWEI volume than is typically acquired. The shear wave arrival times were determined with cross-correlation of shear wave velocity signals in two dimensions after 3-D directional filtering to remove reflection artifacts. To combine data from serially interrogated lateral push locations, arrival times from different pushes were aligned by estimating the shear wave propagation time between push locations. Shear wave data acquired in an elasticity lesion phantom and reconstructed using this algorithm demonstrate benefits to contrast-to-noise ratio (CNR) with increased push beam density and 3-D directional filtering. Increasing the push beam spacing from 0.3 to 11.6 mm (typical for commercial SWEI systems) resulted in a 53% decrease in CNR. In human in vivo data, this imaging approach enabled high CNR (1.61-1.86) imaging of histologically-confirmed prostate cancer. The in vivo images had improved spatial resolution and CNR and fewer reflection artifacts as a result of the high push beam density, the high shear wave SNR, the use of multidimensional directional filtering, and the combination of shear wave data from different push beams.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Fantasmas de Imagen , Relación Señal-Ruido , Diagnóstico por Imagen de Elasticidad/métodos , Algoritmos
6.
Ultrasound Med Biol ; 49(3): 750-760, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36543617

RESUMEN

Shear wave elasticity imaging (SWEI) usually assumes an isotropic material; however, skeletal muscle is typically modeled as a transversely isotropic material with independent shear wave speeds in the directions along and across the muscle fibers. To capture these direction-dependent properties, we implemented a rotational 3-D SWEI system that measures the shear wave speed both along and across the fibers in a single 3-D acquisition, with automatic detection of the muscle fiber orientation. We tested and examined the repeatability of this system's measurements in the vastus lateralis of 10 healthy volunteers. The average coefficient of variation of the measurements from this 3-D SWEI system was 5.3% along the fibers and 8.1% across the fibers. When compared with estimated respective 2-D SWEI values of 16.0% and 83.4%, these results suggest using 3-D SWEI has the potential to improve the precision of SWEI measurements in muscle. Additionally, we observed no significant difference in shear wave speed between the dominant and non-dominant legs along (p = 0.26) or across (p = 0.65) the muscle fibers.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Músculo Esquelético/diagnóstico por imagen , Imagenología Tridimensional , Músculo Cuádriceps , Elasticidad
7.
IEEE Trans Ultrason Ferroelectr Freq Control ; 69(11): 3145-3154, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36054392

RESUMEN

Ultrasonic rotational 3-D shear wave elasticity imaging (SWEI) has been used to induce and evaluate multiple shear wave modes, including both the shear horizontal (SH) and shear vertical (SV) modes in in vivo muscle. Observations of both the SH and SV modes allow the muscle to be characterized as an elastic, incompressible, transversely isotropic (ITI) material with three parameters: the longitudinal shear modulus µL , the transverse shear modulus µT , and the tensile anisotropy χE . Measurement of the SV wave is necessary to characterize χE , but the factors that influence SV mode generation and characterization with ultrasonic SWEI are complicated. This work uses Green's function (GF) simulations to perform a parametric analysis to determine the optimal interrogation parameters to facilitate visualization and quantification of SV mode shear waves in muscle. We evaluate the impact of five factors: µL , µT , χE , fiber tilt angle [Formula: see text], and F-number of the push geometry on SV mode speed, amplitude, and rotational distribution. These analyses demonstrate that the following hold: 1) as µL increases, SV waves decrease in amplitude so are more difficult to measure in SWEI imaging; 2) as µT increases, the SV wave speeds increase; 3) as χE increases, the SV waves increase in speed and separate from the SH waves; 4) as fiber tilt angle [Formula: see text] increases, the measurable SV waves remain approximately the same speed, but change in strength and in rotational distribution; and 5) as the push beam geometry changes with F-number, the measurable SV waves remain approximately the same speed, but change in strength and rotational distribution. While specific SV mode speeds depend on the combinations of all parameters considered, measurable SV waves can be generated and characterized across the range of parameters considered. To maximize measurable SV waves separate from the SH waves, it is recommended to use an F/1 push geometry and [Formula: see text].


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonido , Elasticidad , Anisotropía , Ultrasonografía
8.
IEEE Trans Med Imaging ; 41(1): 133-144, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34415833

RESUMEN

Using a 3D rotational shear wave elasticity imaging (SWEI) setup, 3D shear wave data were acquired in the vastus lateralis of a healthy volunteer. The innate tilt between the transducer face and the muscle fibers results in the excitation of multiple shear wave modes, allowing for more complete characterization of muscle as an elastic, incompressible, transversely isotropic (ITI) material. The ability to measure both the shear vertical (SV) and shear horizontal (SH) wave speed allows for measurement of three independent parameters needed for full ITI material characterization: the longitudinal shear modulus µL , the transverse shear modulus µT , and the tensile anisotropy χE . Herein we develop and validate methodology to estimate these parameters and measure them in vivo, with µL = 5.77±1.00 kPa, µT = 1.93±0.41 kPa (giving shear anisotropy χµ = 2.11±0.92 ), and χE = 4.67±1.40 in a relaxed vastus lateralis muscle. We also demonstrate that 3D SWEI can be used to more accurately characterize muscle mechanical properties as compared to 2D SWEI.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ultrasonido , Anisotropía , Módulo de Elasticidad , Elasticidad , Humanos , Músculos
9.
Front Phys ; 82021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34178971

RESUMEN

Shear wave dispersion (variation of phase velocity with frequency) occurs in tissues with layered and anisotropic microstructure and viscous components, such as the uterine cervix. This phenomenon, mostly overlooked in previous applications of cervical Shear Wave Elasticity Imaging (SWEI) for preterm birth risk assessment, is expected to change drastically during pregnancy due to cervical remodeling. Here we demonstrate the potential of SWEI-based descriptors of dispersion as potential biomarkers for cervical remodeling during pregnancy. First, we performed a simulation-based pre-selection of two SWEI-based dispersion descriptors: the ratio R of group velocities computed with particle-velocity and particle-displacement, and the slope S of the phase velocity vs. frequency. The pre-selection consisted of comparing the contrast-to-noise ratio (CNR) of dispersion descriptors in materials with different degrees of dispersion with respect to a low-dispersive medium. Shear waves induced in these media by SWEI were simulated with a finite-element model of Zener viscoelastic solids. The pre-selection also considered two denoising strategies to improve CNR: a low-pass filter with automatic frequency cutoff determination, and singular value decomposition of shear wave displacements. After pre-selection, the descriptor-denoising combination that produced the largest CNR was applied to SWEI cervix data from 18 pregnant Rhesus macaques acquired at weeks 10 (mid-pregnancy stage) and 23 (late pregnancy stage) of the 24.5-week full pregnancy. A maximum likelihood linear mixed-effects model (LME) was used to evaluate the dependence of the dispersion descriptor on pregnancy stage, maternal age, parity and other experimental factors. The pre-selection study showed that descriptor S combined with singular value decomposition produced a CNR 11.6 times larger than the other descriptor and denoising strategy combinations. In the Non-Human Primates (NHP) study, the LME model showed that descriptor S significantly decreased from mid to late pregnancy (-0.37 ± 0.07 m/s-kHz per week, p <0.00001) with respect to the base value of 15.5 ± 1.9 m/s-kHz. This change was more significant than changes in other SWEI features such as the group velocity previously reported. Also, S varied significantly between the anterior and posterior portions of the cervix (p =0.02) and with maternal age (p =0.008). Given the potential of shear wave dispersion to track cervical remodeling, we will extend its application to ongoing longitudinal human studies.

10.
Ultrason Imaging ; 43(4): 167-174, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33971769

RESUMEN

Correctly calculating skin stiffness with ultrasound shear wave elastography techniques requires an accurate measurement of skin thickness. We developed and compared two algorithms, a thresholding method and a deep learning method, to measure skin thickness on ultrasound images. Here, we also present a framework for weakly annotating an unlabeled dataset in a time-effective manner to train the deep neural network. Segmentation labels for training were proposed using the thresholding method and validated with visual inspection by a human expert reader. We reduced decision ambiguity by only inspecting segmentations at the center A-line. This weak annotation approach facilitated validation of over 1000 segmentation labels in 2 hours. A lightweight deep neural network that segments entire 2D images was designed and trained on this weakly-labeled dataset. Averaged over six folds of cross-validation, segmentation accuracy was 57% for the thresholding method and 78% for the neural network. In particular, the network was better at finding the distal skin margin, which is the primary challenge for skin segmentation. Both algorithms have been made publicly available to aid future applications in skin characterization and elastography.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Algoritmos , Humanos , Ultrasonografía
11.
Ultrasound Med Biol ; 47(7): 1670-1680, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33832823

RESUMEN

Transrectal ultrasound (TRUS) B-mode imaging provides insufficient sensitivity and specificity for prostate cancer (PCa) targeting when used for biopsy guidance. Shear wave elasticity imaging (SWEI) is an elasticity imaging technique that has been commercially implemented and is sensitive and specific for PCa. We have developed a SWEI system capable of 3-D data acquisition using a dense acoustic radiation force (ARF) push approach that leads to enhanced shear wave signal-to-noise ratio compared with that of the commercially available SWEI systems and facilitates screening of the entire gland before biopsy. Additionally, we imaged and assessed 36 patients undergoing radical prostatectomy using 3-D SWEI and determined a shear wave speed threshold separating PCa from healthy prostate tissue with sensitivities and specificities akin to those for multiparametric magnetic resonance imaging fusion biopsy. The approach measured the mean shear wave speed in each prostate region to be 4.8 m/s (Young's modulus E = 69.1 kPa) in the peripheral zone, 5.3 m/s (E = 84.3 kPa) in the central gland and 6.0 m/s (E = 108.0 kPa) for PCa with statistically significant (p < 0.0001) differences among all regions. Three-dimensional SWEI receiver operating characteristic analyses identified a threshold of 5.6 m/s (E = 94.1 kPa) to separate PCa from healthy tissue with a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the curve (AUC) of 81%, 82%, 69%, 89% and 0.84, respectively. Additionally, a shear wave speed ratio was assessed to normalize for tissue compression and patient variability, which yielded a threshold of 1.11 to separate PCa from healthy prostate tissue and was accompanied by a substantial increase in specificity, PPV and AUC, where the sensitivity, specificity, PPV, NPV and AUC were 75%, 90%, 79%, 88% and 0.90, respectively. This work illustrates the feasibility of using 3-D SWEI data to detect and localize PCa and demonstrates the benefits of normalizing for applied compression during data acquisition for use in biopsy targeting studies.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Imagenología Tridimensional , Neoplasias de la Próstata/diagnóstico por imagen , Humanos , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad
12.
Artículo en Inglés | MEDLINE | ID: mdl-33760733

RESUMEN

Ultrasound elasticity imaging in soft tissue with acoustic radiation force requires the estimation of displacements, typically on the order of several microns, from serially acquired raw data A-lines. In this work, we implement a fully convolutional neural network (CNN) for ultrasound displacement estimation. We present a novel method for generating ultrasound training data, in which synthetic 3-D displacement volumes with a combination of randomly seeded ellipsoids are created and used to displace scatterers, from which simulated ultrasonic imaging is performed using Field II. Network performance was tested on these virtual displacement volumes, as well as an experimental ARFI phantom data set and a human in vivo prostate ARFI data set. In the simulated data, the proposed neural network performed comparably to Loupas's algorithm, a conventional phase-based displacement estimation algorithm; the rms error was [Formula: see text] for the CNN and 0.73 [Formula: see text] for Loupas. Similarly, in the phantom data, the contrast-to-noise ratio (CNR) of a stiff inclusion was 2.27 for the CNN-estimated image and 2.21 for the Loupas-estimated image. Applying the trained network to in vivo data enabled the visualization of prostate cancer and prostate anatomy. The proposed training method provided 26 000 training cases, which allowed robust network training. The CNN had a computation time that was comparable to Loupas's algorithm; further refinements to the network architecture may provide an improvement in the computation time. We conclude that deep neural network-based displacement estimation from ultrasonic data is feasible, providing comparable performance with respect to both accuracy and speed compared to current standard time-delay estimation approaches.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Algoritmos , Humanos , Masculino , Redes Neurales de la Computación , Fantasmas de Imagen , Ultrasonografía
13.
J Ultrasound Med ; 40(3): 569-581, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33410183

RESUMEN

OBJECTIVES: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Biomarcadores , Elasticidad , Humanos , América del Norte , Fantasmas de Imagen
15.
Ultrasound Med Biol ; 46(12): 3426-3439, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32988673

RESUMEN

Diagnosing prostate cancer through standard transrectal ultrasound (TRUS)-guided biopsy is challenging because of the sensitivity and specificity limitations of B-mode imaging. We used a linear support vector machine (SVM) to combine standard TRUS imaging data with acoustic radiation force impulse (ARFI) imaging data, shear wave elasticity imaging (SWEI) data and quantitative ultrasound (QUS) midband fit data to enhance lesion contrast into a synthesized multiparametric ultrasound volume. This SVM was trained and validated using a subset of 20 patients and tested on a second subset of 10 patients. Multiparametric US led to a statistically significant improvements in contrast, contrast-to-noise ratio (CNR) and generalized CNR (gCNR) when compared with standard TRUS B-mode and SWEI; in contrast and CNR when compared with MF; and in CNR when compared with ARFI. ARFI, MF and SWEI also outperformed TRUS B-mode in contrast, with MF outperforming B-mode in CNR and gCNR as well. ARFI, although only yielding statistically significant differences in contrast compared with TRUS B-mode, captured critical qualitative features for lesion identification. Multiparametric US enhanced lesion visibility metrics and is a promising technique for targeted TRUS-guided prostate biopsy in the future.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Ultrasonografía Intervencional , Humanos , Aumento de la Imagen , Masculino , Estudios Retrospectivos , Máquina de Vectores de Soporte , Ultrasonografía/métodos
16.
IEEE Trans Med Imaging ; 39(6): 2277-2286, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32012003

RESUMEN

Image post-processing is used in clinical-grade ultrasound scanners to improve image quality (e.g., reduce speckle noise and enhance contrast). These post-processing techniques vary across manufacturers and are generally kept proprietary, which presents a challenge for researchers looking to match current clinical-grade workflows. We introduce a deep learning framework, MimickNet, that transforms conventional delay-and-summed (DAS) beams into the approximate Dynamic Tissue Contrast Enhanced (DTCE™) post-processed images found on Siemens clinical-grade scanners. Training MimickNet only requires post-processed image samples from a scanner of interest without the need for explicit pairing to DAS data. This flexibility allows MimickNet to hypothetically approximate any manufacturer's post-processing without access to the pre-processed data. MimickNet post-processing achieves a 0.940 ± 0.018 structural similarity index measurement (SSIM) compared to clinical-grade post-processing on a 400 cine-loop test set, 0.937 ± 0.025 SSIM on a prospectively acquired dataset, and 0.928 ± 0.003 SSIM on an out-of-distribution cardiac cine-loop after gain adjustment. To our knowledge, this is the first work to establish deep learning models that closely approximate ultrasound post-processing found in current medical practice. MimickNet serves as a clinical post-processing baseline for future works in ultrasound image formation to compare against. Additionally, it can be used as a pretrained model for fine-tuning towards different post-processing techniques. To this end, we have made the MimickNet software, phantom data, and permitted in vivo data open-source at https://github.com/ouwen/MimickNet.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Ultrasonografía
17.
Phys Med Biol ; 65(1): 015014, 2020 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-31775132

RESUMEN

Assessing material properties from observations of shear wave propagation following an acoustic radiation force impulse (ARFI) excitation is difficult in anisotropic materials because of the complex relations among the propagation direction, shear wave polarizations, and material symmetries. In this paper, we describe a method to calculate shear wave signals using Green's tensor methods in an incompressible, transversely isotropic (TI) material characterized by three material parameters. The Green's tensor is written as the sum of an analytic expression for the SH propagation mode, and an integral expression for the SV propagation mode that can be evaluated by interpolation within precomputed integral functions with an efficiency comparable to the evaluation of a closed-form expression. By using parametrized integral functions, the number of required numerical integrations is reduced by a factor of 102-109 depending on the specific problem under consideration. Results are presented for the case of a point source positioned at the origin and a tall Gaussian source similar to an ARFI excitation. For an experimental configuration with a tilted material symmetry axis, results show that shear wave signals exhibit structures that are sufficiently complex to allow measurement of all three material parameters that characterize an incompressible, TI material.


Asunto(s)
Algoritmos , Anisotropía , Diagnóstico por Imagen de Elasticidad/métodos , Ondas de Choque de Alta Energía , Resistencia al Corte , Fenómenos Electromagnéticos , Análisis de Elementos Finitos
18.
Artículo en Inglés | MEDLINE | ID: mdl-31562083

RESUMEN

While ultrasound shear wave elastography originally focused on tissue stiffness under the assumption of elasticity, recent work has investigated the higher order, viscoelastic properties of the tissue. This article presents a method to use group shear wave speeds (gSWSs) at a series of derivative orders to characterize viscoelastic materials. This method uses a least squares fitting algorithm to match the experimental data to the calculated gSWS data, using an assumed material model and excitation geometry matched to the experimental imaging configuration. Building on a previous study that used particle displacement, velocity, and acceleration signals, this study extends the analysis to a continuous range of fractional derivative orders between 0 and 2. The method can be applied to any material model. Herein, material characterization was performed for three different two-parameter models and three different three-parameter models. This group speed-based method was applied to both shear wave simulations with ultrasonic tracking and experimental acquisitions in viscoelastic phantoms [similar to the Phase II Quantitative Imaging Biomarkers Alliance (QIBA) phantoms]. In both the cases, the group speed method produced more repeatable characterization overall than fitting the phase velocity results from the peak of the 2-D Fourier transform. Results suggest that the linear attenuation model is a better fit than the Voigt model for the viscoelastic QIBA phantoms.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Diagnóstico por Imagen de Elasticidad/métodos , Elasticidad/fisiología , Fantasmas de Imagen , Simulación por Computador , Análisis de los Mínimos Cuadrados , Procesamiento de Señales Asistido por Computador , Viscosidad
19.
Artículo en Inglés | MEDLINE | ID: mdl-30507501

RESUMEN

In the original publication of this paper [1], equation (3) contained sign errors for the amplitude of the third and fourth Heaviside functions. The corrected equation is shown in the following: [Formula: see text].

20.
Artículo en Inglés | MEDLINE | ID: mdl-29733281

RESUMEN

Recent investigations of viscoelastic properties of materials have been performed by observing shear wave propagation following localized, impulsive excitations, and Fourier decomposing the shear wave signal to parameterize the frequency-dependent phase velocity using a material model. This paper describes a new method to characterize viscoelastic materials using group shear wave speeds , , and determined from the shear wave displacement, velocity, and acceleration signals, respectively. Materials are modeled using a two-parameter linear attenuation model with phase velocity and dispersion slope at a reference frequency of 200 Hz. Analytically calculated lookup tables are used to determine the two material parameters from pairs of measured group shear wave speeds. Green's function calculations are used to validate the analytic model. Results are reported for measurements in viscoelastic and approximately elastic phantoms and demonstrate good agreement with phase velocities measured using Fourier analysis of the measured shear wave signals. The calculated lookup tables are relatively insensitive to the excitation configuration. While many commercial shear wave elasticity imaging systems report group shear wave speeds as the measures of material stiffness, this paper demonstrates that differences , , and of group speeds are first-order measures of the viscous properties of materials.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Algoritmos , Elasticidad/fisiología , Análisis de Fourier , Fantasmas de Imagen , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA