Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(4): 1173-1184, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38049657

RESUMEN

PURPOSE: The automatic segmentation and detection of prostate cancer (PC) lesions throughout the body are extremely challenging due to the lesions' complexity and variability in appearance, shape, and location. In this study, we investigated the performance of a three-dimensional (3D) convolutional neural network (CNN) to automatically characterize metastatic lesions throughout the body in a dataset of PC patients with recurrence after radical prostatectomy. METHODS: We retrospectively collected [68 Ga]Ga-PSMA-11 PET/CT images from 116 patients with metastatic PC at two centers: center 1 provided the data for fivefold cross validation (n = 78) and internal testing (n = 19), and center 2 provided the data for external testing (n = 19). PET and CT data were jointly input into a 3D U-Net to achieve whole-body segmentation and detection of PC lesions. The performance in both the segmentation and the detection of lesions throughout the body was evaluated using established metrics, including the Dice similarity coefficient (DSC) for segmentation and the recall, precision, and F1-score for detection. The correlation and consistency between tumor burdens (PSMA-TV and TL-PSMA) calculated from automatic segmentation and artificial ground truth were assessed by linear regression and Bland‒Altman plots. RESULTS: On the internal test set, the DSC, precision, recall, and F1-score values were 0.631, 0.961, 0.721, and 0.824, respectively. On the external test set, the corresponding values were 0.596, 0.888, 0.792, and 0.837, respectively. Our approach outperformed previous studies in segmenting and detecting metastatic lesions throughout the body. Tumor burden indicators derived from deep learning and ground truth showed strong correlation (R2 ≥ 0.991, all P < 0.05) and consistency. CONCLUSION: Our 3D CNN accurately characterizes whole-body tumors in relapsed PC patients; its results are highly consistent with those of manual contouring. This automatic method is expected to improve work efficiency and to aid in the assessment of tumor burden.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Masculino , Humanos , Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Isótopos de Galio , Estudios Retrospectivos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Prostatectomía , Ácido Edético
2.
Eur Radiol ; 33(4): 2699-2709, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36434397

RESUMEN

OBJECTIVES: To compare the diagnostic performance of a novel deep learning (DL) method based on T2-weighted imaging with the vesical imaging-reporting and data system (VI-RADS) in predicting muscle invasion in bladder cancer (MIBC). METHODS: A total of 215 tumours (129 for training and 31 for internal validation, centre 1; 55 for external validation, centre 2) were included. MIBC was confirmed by pathological examination. VI-RADS scores were provided by two groups of radiologists (readers 1 and readers 2) independently. A deep convolutional neural network was constructed in the training set, and validation was conducted on the internal and external validation sets. ROC analysis was performed to evaluate the performance for MIBC diagnosis. RESULTS: The AUCs of the DL model, readers 1, and readers 2 were as follows: in the internal validation set, 0.963, 0.843, and 0.852, respectively; in the external validation set, 0.861, 0.808, and 0.876, respectively. The accuracy of the DL model in the tumours scored VI-RADS 2 or 3 was higher than that of radiologists in the external validation set: for readers 1, 0.886 vs. 0.600, p = 0.006; for readers 2, 0.879 vs. 0.636, p = 0.021. The average processing time (38 s and 43 s in two validation sets) of the DL method was much shorter than the readers, with a reduction of over 100 s in both validation sets. CONCLUSIONS: Compared to radiologists using VI-RADS, the DL method had a better diagnostic performance, shorter processing time, and robust generalisability, indicating good potential for diagnosing MIBC. KEY POINTS: • The DL model shows robust performance for MIBC diagnosis in both internal and external validation. • The diagnostic performance of the DL model in the tumours scored VI-RADS 2 or 3 is better than that obtained by radiologists using VI-RADS. • The DL method shows potential in the preoperative assessment of MIBC.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Vejiga Urinaria , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patología , Vejiga Urinaria/patología , Músculos/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...