Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Endourol ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225163

RESUMEN

Objective: To evaluate the ablation speed (AS), laser efficiency and direct thermal lesions during urinary stone lithotripsy with the current available laser technologies: Holmium:YAG (Ho:YAG), pulsed-Thulium:YAG (p-Tm:YAG) and Thulium Fiber Laser (TFL) in-vitro using different laser settings. Materials and methods: Ho:YAG, p-Tm:YAG and TFL laser system were used in an in vitro ureteral model with a volume of 125 mm3 Begostone. The following parameters were tested across all laser devices: 0.6 J/10 Hz (6 W), 0.6 J/20 Hz (12 W), 1.5 J/10 Hz (15 W), and 1.5 J/20 Hz (30 W), employing short pulse width for all lasers and long pulse width for Ho:YAG and p-Tm:YAG. Ten participants conducted the experimental setup during 3-minutes laser on time, combining the laser technology, settings, and pulse widths, with a total of 20 different combinations. The efficiency, AS and ureteral damage resulting from each intervention were analyzed. Results: p-Tm:YAG and TFL demonstrated significantly higher efficiency compared to Ho:YAG (0.049 ± 0.02 ∆gr/KJ and 0.042 ± 0.01 ∆gr/KJ vs 0.029 ± 0.01 ∆gr/KJ; p < 0.05). In all laser sources, as the power increases, the AS also increases (p<0.05). Furthermore, only at high-energy settings (1.5J) higher frequency led to increase AS (p<0.05). Both, p-Tm:YAG and TFL exhibited higher AS compared to Ho:YAG (0.64 ± 0.33 ∆gr/s and 0.62 ± 0.31 ∆gr/s vs 0.44 ± 0.22 ∆gr/s; p < 0.05). Regarding ureteral injuries, as the power increases, there is a higher chance of ureteral damage (p=0.031). No differences were observed between laser technologies (p=0.828). Conclusions: Both, p-Tm:YAG and TFL exhibited superior performances during laser lithotripsy compared to Ho:YAG, as they demonstrated higher efficiency and ablation speed. Thermal damage did not appear to be associated with specific laser equipment, but higher grades of lesions are described by increasing power.

2.
J Endourol ; 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39283822

RESUMEN

OBJECTIVE: To characterize the pulse characteristics and risk of fiber fracture(ROF) of the pulsed-Thulium:YAG(p-Tm:YAG) Laser , and to compare its ablation volumes(AVs) against Holmium:YAG(Ho:YAG) and Thulium Fiber Lasers(TFL). MATERIALS AND METHODS: p-Tm:YAG(100W-Thulio,DornierMedtech©,Germany) was characterized using single-use 272µm core-diameter-fibers(CDF). p-Tm:YAG characterization included pulse shape, duration and Peak Power (PP) studies. ROF was assessed after 5min continuous laser activation(CLA) at five decreasing fiber bend radii(1, 0.9, 0.75, 0.6, and 0.45cm). p-Tm:YAG, Ho:YAG (120W-Cyber-Ho,Quanta®,USA) and TFL (60W-TFLDrive(Coloplast®, Denmark)) AVs were compared using a 20mm linear CLA at 2mm/sec velocity in contact with 20mm cubic hard and soft stone phantoms(HSP and SSP, 15:3 and 15:5 water to powder ratio) fully submerged in saline solution at 0.5J-20Hz or 1J-10Hz. After CLA, phantoms underwent three-dimensional(3D) micro-scanning(computed tomography) and subsequent 3D segmentation to estimate the AVs, using 3DSlicer©. Each experiment was performed in triplicate. RESULTS: p-Tm:YAG presents a uniform pulse profile in all of the available pre-set modes. Peak Power(PP) ranged from 564 to 2199W depending on pulse mode. No Laser fiber(LF) fracture occurred at any bend radius. p-Tm:YAG achieved similar mean AVs to TFL and Ho:YAG for HSP(8.96±3.1 vs 9.78±1.1 vs 8.8±2.8mm3, p=0.67) but TFL was associated with higher AVs compared to p-Tm:YAG and Ho:YAG(12.86±1.85 vs 10.12±1.89 vs 7.56±2.21mm3, p=0.002) against SSP. AVs for HSP increased with pulse energy for p-Tm:YAG and Ho:YAG and (11.56±1.8 vs 6.36±0.84 mm3 and 11.27±1.98 vs 6.34±0.55mm3,p=0,03 and p=0,02), while AVs for SSP were similar across laser settings for all laser sources. AVs with TFL were similar across laser settings for both phantom types. CONCLUSION: p-Tm:YAG combines intermediate Peak Power between Ho:YAG and TFL, a uniform pulse profile, no risk of fiber fracture with increasing deflection and effective ablation rates. Further clinical studies are needed to confirm these in vitro results.

3.
World J Urol ; 42(1): 487, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39158747

RESUMEN

OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.


Asunto(s)
Litotripsia por Láser , Tulio , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Uréter/cirugía , Cálculos Ureterales/cirugía , Técnicas In Vitro , Láseres de Estado Sólido/uso terapéutico
4.
J Clin Med ; 13(14)2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39064308

RESUMEN

This review addresses the management of urolithiasis in renal transplant recipients, a notably vulnerable group due to the unique anatomical and physiological alterations of the transplanted organ. The prevalence of nephrolithiasis in these patients varies between 0.1% and 6.3%, with a significant impact on graft longevity and function. Surgical access complications due to the renal graft's position on the iliac vessels and the variety of urinary anastomoses complicate the treatment approaches. This study evaluates the effectiveness and outcomes of percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), two primary minimally invasive strategies for managing graft stones. Through a narrative review using the PubMed and EMBASE databases, it was found that PCNL offers high stone-free rates especially beneficial for large stones, whereas URS provides a less invasive option with a lower risk of complications for small stones. Both techniques require tailored approaches based on stone composition-mostly calcium oxalate-and specific patient anatomical factors. This review underscores the importance of early diagnosis, appropriate treatment selection, and continuous post-treatment monitoring to mitigate risks and promote long-term renal function in transplant recipients.

5.
World J Urol ; 42(1): 453, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073430

RESUMEN

PURPOSE: To examine temporal-spatial distribution of heat generated upon laser activation in a bench model of renal calyx. To establish reference values for a safety distance between the laser fiber and healthy tissue during laser lithotripsy. METHODS: We developed an in-vitro experimental setup employing a glass pipette and laser activation under various intra-operative parameters, such as power and presence of irrigation. A thermal camera was used to monitor both temporal and spatial temperature changes during uninterrupted 60-second laser activation. We computed the thermal dose according to Sapareto and Dewey's formula at different distances from the laser fiber tip, in order to determine a safety distance. RESULTS: A positive correlation was observed between average power and the highest recorded temperature (Spearman's coefficient 0.94, p < 0.001). Irrigation was found to reduce the highest recorded temperature, with a maximum average reduction of 9.4 °C at 40 W (p = 0.002). A positive correlation existed between average power and safety distance values (Spearman's coefficient 0.86, p = 0.001). A thermal dose indicative of tissue damage was observed at 20 W without irrigation (safety distance 0.93±0.11 mm). While at 40 W, irrigation led to slight reduction in mean safety distance (4.47±0.85 vs. 5.22±0.09 mm, p = 0.08). CONCLUSIONS: Laser settings with an average power greater than 10 W deliver a thermal dose indicative of tissue damage, which increases with higher average power values. According to safety distance values from this study, a maximum of 10 W should be used in the ureter, and a maximum of 20 W should be used in kidney in presence of irrigation.


Asunto(s)
Litotripsia por Láser , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Calor , Cálices Renales , Irrigación Terapéutica/métodos
6.
BJU Int ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38994628

RESUMEN

OBJECTIVES: To assess laser-tissue interactions through ablation, coagulation, and carbonisation characteristics in a non-perfused porcine kidney model between three pulsed lasers: holmium (Ho): yttrium-aluminium-garnet (YAG), thulium fiber laser (TFL), and pulsed thulium (p-Tm):YAG. MATERIALS AND METHODS: A 150-W Ho:YAG, a 60-W TFL, and a 100-W p-Tm:YAG lasers were compared. The laser settings that can be set identically between the three lasers and be clinically relevant for prostate laser enucleation were identified and used on fresh, unfrozen porcine kidneys. Laser incisions were performed using stripped laser fibers of 365 and 550 µm, set at distances of 0 and 1 mm from the tissue surface at a constant speed of 2 mm/s. Histological analysis evaluated shape, depth, width of the incision, axial coagulation depth, and presence of carbonisation. RESULTS: Incision depths, widths, and coagulation zones were greater with Ho:YAG and p-Tm:YAG lasers than TFL. Although no carbonisation was found with the Ho:YAG and p-Tm:YAG lasers, it was common with TFL, especially at high frequencies. The shapes of the incisions and coagulation zones were more regular and homogeneous with the p-Tm:YAG laser and TFL than with Ho:YAG laser. Regardless of the laser used, short pulse durations resulted in deeper incisions than long pulse durations. Concerning the distance, we found that to be effective, TFL had to be used in contact with the tissue. Finally, 365-µm fibers resulted in deeper incisions, while 550-µm fibers led to wider incisions and larger coagulation zones. CONCLUSION: Histological analysis revealed greater tissue penetration with the p-Tm:YAG laser compared to the TFL, while remaining less than with Ho:YAG. Its coagulation properties seem interesting insofar as it provides homogeneous coagulation without carbonisation, while incisions remained uniform without tissue laceration. Thus, the p-Tm:YAG laser appears to be an effective alternative to Ho:YAG and TFL lasers in prostate surgery.

7.
Eur Urol ; 86(3): 198-199, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38890068

RESUMEN

There is a lack of consensus on definitions for the success of endourological stone treatments. The zero-fragment rate (residual fragments [RFs] <1 mm) is now considered more accurate than the stone-free rate (RFs ≤4 mm). As stone volume may be adopted as the recommended method for preoperative estimation of the stone burden, the volumetric stone-free rate may be superior to standard linear RF measurements in defining success.


Asunto(s)
Ureteroscopía , Humanos , Resultado del Tratamiento , Cálculos Renales/cirugía , Urología , Litotricia/métodos
8.
Eur Urol Oncol ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38937207

RESUMEN

BACKGROUND AND OBJECTIVE: A hilar location for a renal tumour is sometimes viewed as a limiting factor for safe partial nephrectomy. Our aim was to evaluate perioperative, oncological, and functional outcomes of robot-assisted partial nephrectomy (RAPN) for hilar tumours (RAPN-H) in comparison to RAPN for nonhilar tumours (RAPN-NH). METHODS: We conducted an observational, multicentre cohort study using prospectively collected data from the French Research Network on Kidney Cancer (UroCCR). The registry includes data for 3551 patients who underwent RAPN for localised or locally advanced renal masses between 2010 and 2023 in 29 hospitals in France. We studied the impact of a hilar location on surgery, postoperative renal function, tumour characteristics, and survival. We also compared rates of trifecta achievement (warm ischaemia time [WIT] <25 min, negative surgical margins, and no perioperative complications) between the groups. Finally, we performed a subgroup analysis of RAPN without vascular clamping. Variables were compared in univariable analysis and using multivariable linear, logistic, and Cox proportional-hazards models adjusted for relevant patient and tumour covariates. KEY FINDINGS AND LIMITATIONS: The analytical population included 3451 patients, of whom 2773 underwent RAPN-NH and 678 underwent RAPN-H. Longer WIT (ß = 2.4 min; p < 0.01), longer operative time (ß = 11.4 min; p < 0.01) and a higher risk of postoperative complications (odds ratio 1.33; p = 0.05) were observed in the hilar group. Blood loss, the perioperative transfusion rate, postoperative changes in the estimated glomerular filtration rate, and trifecta achievement rates were comparable between the groups (p > 0.05). At mean follow-up of 31.9 mo, there was no significant difference in recurrence-free survival (hazard ratio [HR] 0.82, 95% confidence interval [CI] 0.58-1.2; p = 0.3), cancer-specific survival (HR 1.1, 95% CI 0.48-2.6; p = 0.79), or overall survival (HR 0.89, 95% CI 0.52-1.53; p = 0.69). CONCLUSIONS AND CLINICAL IMPLICATIONS: Patient and tumour characteristics rather than just hilar location should be the main determinants of the optimal surgical strategy for hilar tumours. PATIENT SUMMARY: We found that kidney tumours located close to major kidney blood vessels led to a longer operation and a higher risk of complications during robot-assisted surgery to remove the tumour. However, tumours in these locations were not related to a higher risk of kidney function loss, cancer recurrence, or death.

9.
Fr J Urol ; 34(7-8): 102644, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759842

RESUMEN

OBJECTIVES: To characterize and compare in vitro the surfaces of ureteral stents (STENTS) before utilization. METHODS: Our in vitro experiment included six unused STENTS models: three double-pigtail with side orifices (ImaJin and Stenostent [Coloplast©,France], TriaSoft [BostonScientific©,USA]), two double-pigtail without side orifice (Vortek-TumorStent [Coloplast©,France], Urosoft-TumorStent [Bard-Angiomed©,Germany]) and one single-pigtail (J-Fil [Rocamed©,Monaco]). STENTS were made of polyurethane except for ImaJin (silicone). For all STENTS, four parts of the stent were specifically analyzed under high-resolution scanning electron microscopy (HR-SEM,FEI-XL40 [Philips©,France]): surface core, lateral orifice, ureteral loop, and black marking surface. Each experiment was repeated with three different samples from three different stents. STENTS analysis included multiple imperfection searches, defined as irregularities>10µm. RESULTS: All STENTS presented imperfections with no discernible differences. Imperfections were mainly located on the stent loop and on the lateral orifice. For STENTS without side orifice (J-Fil, Urosoft) imperfections were also reported, on the beveled cut as well as the distal loop orifice. Marking surfaces examinations found defects in the Urosoft and imperfections in the ImaJin and Stenostent. The Triasoft presented a better smoothness on marking surfaces compared to other STENTS. Additional matter was reported on the loop distal orifice for J-Fil and ImaJin but all STENTS presented irregular cross-sectional aeras. CONCLUSION: All ureteral stents are not perfectly smooth even before utilization. Imperfections were noticed regardless to stent composition or shape, and could play a role in the incrustation phenomenon, is association with inner irregularities, infection, and urine composition. Both manufacturing and material could have an impact on the stent external surface's smoothness.


Asunto(s)
Microscopía Electrónica de Rastreo , Stents , Uréter , Técnicas In Vitro , Ensayo de Materiales , Poliuretanos/química , Diseño de Prótesis , Stents/efectos adversos , Propiedades de Superficie , Uréter/cirugía
10.
World J Urol ; 42(1): 355, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38796790

RESUMEN

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Asunto(s)
Diseño de Equipo , Iluminación , Ureteroscopios , Ureteroscopía , Luz , Humanos , Solución Salina , Color
11.
World J Urol ; 42(1): 362, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38814457

RESUMEN

OBJECTIVE: To evaluate long-term surgical and functional outcomes of cystinuric patients exclusively treated with Ureteroscopy (URS). METHODS: Data from patients treated for cystine stones at a single academic center were retrospectively analyzed. The management protocol consisted of (i) treating symptomatic or > 7 mm stones, (ii) multi-staged URS for voluminous stones, (iii) referring patients to a dedicated nephrological clinic. The eGFR was calculated according to the MDRD formula. CKD category was assessed according to the NKF classification. Relevant CKD was defined as CKD category ≥ 3a. Descriptive statistics were used to analyze the cohort data. RESULTS: Data from 46 cystinuric patients treated with 332 URS were available. Median age at diagnosis and at first URS in our center were 18 and 32 years, respectively. Median follow-up was 101 months. Median number of URS and recurrences per patient were 6 and 2, respectively. The median interval between the first and the last available creatinine level was 64 months. Median first and last eGFR were 72 and 74 mL/min, respectively. Overall, 83% of patients had stable or improved renal function within the study period. Ureteral stricture occurred in 3 (6.5%) patients. CONCLUSIONS: Cystinuria requires intensive endoscopic management. Most patients treated with URS have stable or improved renal function within a long-term follow-up. CKD is a not neglectable event that potentially occurs at an early stage of life. Current findings should be considered for the surgical management of cystinuric patients.


Asunto(s)
Cistinuria , Centros de Atención Terciaria , Ureteroscopía , Humanos , Masculino , Estudios Retrospectivos , Adulto , Femenino , Adolescente , Cistinuria/complicaciones , Adulto Joven , Resultado del Tratamiento , Factores de Tiempo , Cálculos Renales/cirugía , Persona de Mediana Edad , Niño
12.
World J Urol ; 42(1): 294, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704777

RESUMEN

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Asunto(s)
Ureteroscopios , Ureteroscopía , Humanos , Diseño de Equipo , Iluminación , Docilidad , Cálices Renales
13.
World J Urol ; 42(1): 292, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704492

RESUMEN

PURPOSE: During endoscopic stone surgery, Holmium:YAG (Ho:YAG) and Thulium Fiber Laser (TFL) technologies allow to pulverize urinary stones into fine particles, ie DUST. Yet, currently there is no consensus on the exact definition of DUST. This review aimed to define stone DUST and Clinically Insignificant Residual Fragments (CIRF). METHODS: Embase, MEDLINE (PubMed) and Cochrane databases were searched for both in vitro and in vivo articles relating to DUST and CIRF definitions, in November 2023, using keyword combinations: "dust", "stones", "urinary calculi", "urolithiasis", "residual fragments", "dusting", "fragments", "lasers" and "clinical insignificant residual fragments". RESULTS: DUST relates to the fine pulverization of urinary stones, defined in vitro as particles spontaneously floating with a sedimentation duration ≥ 2 sec and suited for aspiration through a 3.6Fr-working channel (WC) of a flexible ureteroscope (FURS). Generally, an upper size limit of 250 µm seems to agree with the definition of DUST. Ho:YAG with and without "Moses Technology", TFL and the recent pulsed-Thulium:YAG (pTm:YAG) can produce DUST, but no perioperative technology can currently measure DUST size. The TFL and pTm:YAG achieve better dusting compared to Ho:YAG. CIRF relates to residual fragments (RF) that are not associated with imminent stone-related events: loin pain, acute renal colic, medical or interventional retreatment. CIRF size definition has decreased from older studies based on Shock Wave Lithotripsy (SWL) (≤ 4 mm) to more recent studies based on FURS (≤ 2 mm) and Percutaneous Nephrolithotomy(PCNL) (≤ 4 mm). RF ≤ 2 mm are associated with lower stone recurrence, regrowth and clinical events rates. While CIRF should be evaluated postoperatively using Non-Contrast Computed Tomography(NCCT), there is no consensus on the best diagnostic modality to assess the presence and quantity of DUST. CONCLUSION: DUST and CIRF refer to independent entities. DUST is defined in vitro by a stone particle size criteria of 250 µm, translating clinically as particles able to be fully aspirated through a 3.6Fr-WC without blockage. CIRF relates to ≤ 2 RF on postoperative NCCT.


Asunto(s)
Ureteroscopía , Cálculos Urinarios , Humanos , Cálculos Urinarios/terapia , Litotripsia por Láser/métodos , Polvo , Tamaño de la Partícula
14.
World J Urol ; 42(1): 298, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709327

RESUMEN

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Asunto(s)
Diseño de Equipo , Riñón , Iluminación , Ureteroscopios , Modelos Anatómicos , Humanos
15.
J Endourol ; 38(8): 725-740, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38666692

RESUMEN

Objectives: To perform a systematic review on artificial intelligence (AI) performances to detect urinary stones. Methods: A PROSPERO-registered (CRD473152) systematic search of Scopus, Web of Science, Embase, and PubMed databases was performed to identify original research articles pertaining to AI stone detection or measurement, using search terms ("automatic" OR "machine learning" OR "convolutional neural network" OR "artificial intelligence" OR "detection" AND "stone volume"). Risk-of-bias (RoB) assessment was performed according to the Cochrane RoB tool, the Joanna Briggs Institute Checklist for nonrandomized studies, and the Checklist for Artificial Intelligence in Medical Imaging (CLAIM). Results: Twelve studies were selected for the final review, including three multicenter and nine single-center retrospective studies. Eleven studies completed at least 50% of the CLAIM checkpoints and only one presented a high RoB. All included studies aimed to detect kidney (5/12, 42%), ureter (2/12, 16%), or urinary (5/12, 42%) stones on noncontrast computed tomography (NCCT), but 42% intended to automate measurement. Stone distinction from vascular calcification interested two studies. All studies used AI machine learning network training and internal validation, but a single one provided an external validation. Trained networks achieved stone detection, with sensitivity, specificity, and accuracy rates ranging from 58.7% to 100%, 68.5% to 100%, and 63% to 99.95%, respectively. Detection Dice score ranged from 83% to 97%. A high correlation between manual and automated stone volume (r = 0.95) was noted. Differentiate distal ureteral stones and phleboliths seemed feasible. Conclusions: AI processes can achieve automated urinary stone detection from NCCT. Further studies should provide urinary stone detection coupled with phlebolith distinction and an external validation, and include anatomical abnormalities and urologic foreign bodies (ureteral stent and nephrostomy tubes) cases.


Asunto(s)
Inteligencia Artificial , Cálculos Urinarios , Humanos , Cálculos Urinarios/diagnóstico por imagen , Aprendizaje Automático , Tomografía Computarizada por Rayos X
16.
Eur Urol Open Sci ; 63: 89-95, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38585592

RESUMEN

Background and objective: Data regarding open conversion (OC) during minimally invasive surgery (MIS) for renal tumors are reported from big databases, without precise description of the reason and management of OC. The objective of this study was to describe the rate, reasons, and perioperative outcomes of OC in a cohort of patients who underwent MIS for renal tumor initially. The secondary objective was to find the factors associated with OC. Methods: Between 2008 and 2022, of the 8566 patients included in the UroCCR project prospective database (NCT03293563), who underwent laparoscopic or robot-assisted minimally invasive partial (MIPN) or radical (MIRN) nephrectomy, 163 experienced OC. Each center was contacted to enlighten the context of OC: "emergency OC" implied an immediate life-threatening situation not reasonably manageable with MIS, otherwise "elective OC". To evaluate the predictive factors of OC, a 2:1 paired cohort on the UroCCR database was used. Key findings and limitations: The incidence rate of OC was 1.9% for all cases of MIS, 2.9% for MIRN, and 1.4% for MIPN. OC procedures were mostly elective (82.2%). The main reason for OC was a failure to progress due to anatomical difficulties (42.9%). Five patients (3.1%) died within 90 d after surgery. Increased body mass index (BMI; odds ratio [OR]: 1.05, 95% confidence interval [CI]: 1.01-1.09, p = 0.009) and cT stage (OR: 2.22, 95% CI: 1.24-4.25, p = 0.008) were independent predictive factors of OC. Conclusions and clinical implications: In MIS for renal tumors, OC was a rare event (1.9%), caused by various situations, leading to impaired perioperative outcomes. Emergency OC occurred once every 300 procedures. Increased BMI and cT stage were independent predictive factors of OC. Patient summary: The incidence rate of open conversion (OC) in minimally invasive surgery for renal tumors is low. Only 20% of OC procedures occur in case of emergency, and others are caused by various situations. Increased body mass index and cT stage were independent predictive factors of OC.

17.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613608

RESUMEN

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Holmio , Tulio , Ureteroscopía , Estudios Prospectivos , Cálculos Renales/cirugía , Rayos Láser
19.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
20.
Fr J Urol ; 34(4): 102609, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38460936

RESUMEN

Angiosarcoma is a rare malignancy derived from endothelial cells, which behaves aggressively. Primary angiosarcoma of the kidney is even rarer, and its clinical and radiological presentations do not differ from clear cells renal cell carcinoma (ccRCC). Management protocols are not standardized, although nephrectomy is usually performed. Subsequent treatments (chemotherapy, radiotherapy, and lately, targeted therapies) vary considerably. Herein, we report the case of a middle-aged patient harboring primary angiosarcoma of the left kidney and discuss its presentation and management in light of current guidelines. The case is described for its rarity and masquerading nature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA